Effect of Temperature vs Base Sediment & Water in Waxy Crude Oil

Similar documents
SIGMA 3 ENGINEERING LIMITED

INCREASING PRODUCTION CAPACITY OF MATURE ASSETS THE CARDAMOM FIELD TIE-BACK TO AUGER TLP

DEHYDRATION AND DESALTING

Shale Oils Designing for Improved Crude Preheat Train Reliability and Performance

Gas Plant Training Module 4 TEG Dehydration Systems

Technical Discussion on

There are a number of factors in a process which may result in liquid entrainment. Some of the commonly observed causes are discussed below.

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

Installation of Downhole Heaters to Prevent Paraffin Blockages

System Solutions. Efficient energy use, effective flash steam utilisation, and tailor-made customer solutions CHEMICAL THE STEAM SPECIALIST.

DS Series. Ultraaqua Autoclean. Oil/Water Separators

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

Leading Innovation in Compressed Air Treatment CTS SERIES ELIMINATOR II OIL WATER SEPARATORS

SEPREMIUM 10 SEPREMIUM 20 SEPREMIUM 30 SEPREMIUM 10 SEPREMIUM 30

Jet Vacuum Systems. GEA Wiegand GmbH

Gas And Process Stories. Atlas Copco Gas and Process and Iran s Gas Development Program. CopcoCustomerNews. Volume 1 January 2004

EXPERIENCES OF REDUCING STEAM CONSUMPTION IN A SUGAR PLANT

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Landfill & Digester Gas Dryers. Features and Benefits

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Ashirwad Carbonics (India) Private Limited

Kube Engineering. Industry Guide. Power Industry

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

Construction and Installation Instructions For the A&A Splash Pad

FOR THE PETROLEUM AND RELATED INDUSTRIES

Evaporation Technology

Refrigeration and Boil Off Compression Systems for NGL Export Facilities

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

PERFORMANCE OF A MODEL IN-LINE VORTEX SEPARATOR. Keng-Choon Lee Geothermal Institute, The University of Auckland, Private Bag 92019, Auckland, New

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

SUNOCO Heat Transfer Fluids

Industrial Processing Solutions

Oil and Gas Heaters ZICOM EQUIPMENT PTE LTD

SCHEUCH ELECTROSTATIC PRECIPITATORS INNOVATIVE TECHNOLOGIES FOR DEDUSTING FLUE GASES

Optimizing Continuous Deodorization for Quality and Energy

What is a Secondary Pressure Drainer?

Welkom. Optimalisatie CO2 systemen m.b.v. ejecteur

WELL & RESERVOIR MONITORING

T F E

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

Figure 1. Ejector cross-sectional drawing. Figure 2. Precondenser to left of vacuum flasher. pressure.

Boiler Basics. Design and operation

ENGINEERING. Product Overview #AR-OV-11a

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE

ES-6. Encapsulated Rotary Screw Air Compressors. 4 7 kw 5 10 hp

The Experts in Vacuum Solutions

THE INITIATES PLC (TIP) Waste Management & Industrial Cleaning Services

Condensate Recovery and Return System SDR A

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

CO2 TRANSCRITICAL BOOSTER SYSTEMS

For inspection purposes only.

LIQUID RING PUMPS FOR THE POWER INDUSTRY

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

2007 KBC Advanced Technologies plc. All Rights Reserved.

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Water Fuel + Air for combustion Blowdown

SAFE TRANSPORTATION OF LIQUID SULPHUR

Deaerator. Specifications

S0300-BV-CAT-020 EQUIPMENT DECONTAMINATION SYSTEM. System - P Equipment Decontamination System P /18/2018 2:24:26 PM

TECHNICAL PUBLICATION

Understanding Process Vacuum for Process Improvement

TECHNOSKLO Ltd. Držkov

DTI Kenneth Bank Madsen Global Application Expert Food Retail

Conservation & Energy Efficiency Activities

What is a Safe NPSH Margin for a Centrifugal Pump? Can You Provide Too Much NPSH?

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Heat Exchanger Solutions For the oil and gas industry

OPTIMISE VACUUM TO IMPROVE PLANT PERFORMNCE

APPA Institute for Facilities Management. Energy & Utilities Cooling Production (316) Purpose of Today s Presentation. Agenda

Enviro International Corporation. WET SCRUBBER

Understanding of Surface Heat Tracing of Bulk Storage Tanks for Viscous and High Pour Point Fluids - By, H. R. Mullan

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

LEWA Plunger pumps. For high hydraulic power.

CPF PRODUCT DESCRIPTION

Use of Electric Downhole Heaters to Prevent Wax Build-up, Offshore, West Africa by Alistair Hill and Rick Newell, Pentair Thermal Management

Knock Out Drum Sizing Calculation

Falling-film evaporators.

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant


AE R1 March 1993 Reformatted November Compressor Overheating

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Summary of 60-Day Notice: Heating Efficiency

Pump Stroke Optimization: A Better Way

Amec Foster Wheeler- Fired Heater Division

STEAM ECONOMY EQUIPMENTS & SYSTEMS FOR SUGAR MILLS

CPC PRODUCT DESCRIPTION

PIPELINE LEAKAGE DETECTION

The leader in gas dehydration & filtration

Transcription:

P-064 Effect of Temperature vs Base Sediment & Water Bharani Raj*, Sayantan Bhattacharya, Cairn Energy Ltd. Introduction Block RJ-ON-90/1 is located in the state of Rajasthan in North-West India. Four discoveries have been declared commercial within the RJ-ON- 90/1 Development Area: Mangala, Aishwariya, Saraswati, and Raageshwari. Bhagyam (and Shakti) are subsequent discoveries and have separate development areas (reference approval from DGH 14th November 2006); the locations of the fields under development naturally fall into 2 geographical groups. The three largest fields are located in the North of the block and comprise Rajasthan Northern Area Development : Mangala, Aishwariya and Bhagyam. The significantly smaller fields located in the South of the block comprise the Rajasthan Southern Area Development, Saraswati and Raageshwari. The size and location of the fields dictates how the fields are to be developed. It is expected that plateau production rates from Mangala will be achieved shortly after start-up. This forms the core of a wider development and the development of the other Northern fields will take advantage of synergies with the Mangala development. The main power generation plant, oil storage and export point are to be located at the Mangala Process Terminal (MPT). Figure: 1 Rajasthan Block The Mangala field crude oil characteristics are as follows: 1. Waxy sweet crude oil 2. Volumetric average gravity of the oil is 27º API; with sulphur content less than 0.2% is estimated. 3. Low gas-oil ratio (GOR) of 82-203 scf/bbl (volume weighted average GOR 184 scf/bbl). 4. The live oil wax appearance temperature is only some 2 to 3oC lower than the average reservoir temperature of 65 o C. Cairn Energy India Ltd. India bharaniraj.g@cairnindia.com sayantan.bhattacharya@cairnindia.com

5. Gas contains a high level of carbon dioxide (between 20 and 30mol %) 6. High pour point of (>40oC), which has a great influence on all aspects of the project and the process design to ensure efficient flow assurance. The field development plan is based on implementation of a water flood from the start of production to maintain reservoir pressure and to sweep reserves. Hot water, at a temperature above the reservoir wax dissolution temperature, will be injected to ensure that injectivity and efficient oil sweep are maintained. The following sections provide an overview of the key elements of the Mangala Field Development Plan, with focus on the salient details in flow assurance and production enhancement techniques. There are a large number of factors that have to be considered in the design of the Mangala facilities. The main challenges relate to the flow assurance, production chemistry, to maintain optimum temperature which should be above Wax appearing temperature and to break emulsion to meet specification of BS&W. The focus for facilities design for the Mangala Development is to provide flexibility in the facilities design, at optimal cost, to allow for opportunities and uncertainties to be managed during the life of the field. Theory Crude from reservoir is mixed with circulating hot water that maintains temperature around 65-70 C slightly above Wax appearing temperature reaches processing terminal for separation of Gas, oil and water. The production fluid from the Mangala well-pads is received via eight permanent Pig Receivers Skids into a single common inlet manifold and routed to the Slug Catchers. The Slug Catchers are horizontal, overflow weirtype, three phase separators designed to separate free water, oil and associated gas from production fluids as well as dampening any slugging that may occur from the pipelines. Associated gas flows to the Fuel Gas system (consisting of fuel gas scrubber, fuel gas filters & fuel gas heaters) under pressure control for firing of boilers The oil/water emulsion stream from slug catcher flows to shell & tube type Production Heaters where the temperature is increased above the emulsion break point in order to accelerate oil and water separation in the Production Separators. The process fluid enters the Production Separators where further oil and water separation and degassing occurs. Each Production Separator is a horizontal, overflow weir-type; three-phase separator which separates associated gas, oil, and produced water. The gas flows to 2nd stage suction of the Vapour Recovery Unit Compressor under pressure control. A spill off pressure control valve to the HP Flare is also provided to accommodate any upset conditions. The Gun Barrel Setting Tanks are intended for stabilisation of oil and to allow time for gravity separation. The gun barrel section of the tank is designed to remove the remaining flash gas prior to entering the settling tank section to avoid interference with the oil/water separation in the tanks. Stabilized oil from the settling tank is pumped by stabilized oil pumps to dehydrator for final stabilization of oil. The Dehydrators are electrostatic Coalescer type units complete with inlet distributors, oil outlet collectors, electrodes and transformers for 2

Figure2: Layout of Mangala Processing knocking off any final traces of water in the oil, after knocking off final traces of water in dehydrator it is sent to export tanks for export. Advance Flow assurance and separation technique at MPT. a) Hot water is mixed with production fluid at surface. The objective is to heat the production fluid temperature by flowing it through annulus of the wells co-mingled with crude at the surface. The circulation water is of high pressure (2600 Psig) and temperature (85 Deg C) which provides motive fluid for the wells equipped with Jet pumps. The system also transfers heat to the production fluids to maintain the temperature above the WAT (Wax appearance temperature). b) The below Graph mention the temperature profile maintain at processing terminal c) Production fluid pipelines at Mangala Processing terminal are electrically heat traced to avoid congealing or pressure drop in pipelines due to wax formation. d) Demulsifer is being injected at Well pads is used to break the emulsion and for proper separation in the separators to meet BS&W as per sales requirement. Figure 3: Temperature Profile at Mangala Processing Terminal for train-2 3

Figure 4: Temperature Profile at Mangala Processing Terminal for train-3 Case Study Effect of reducing temperature Optimizing in operating temperature profile of oil train was carried for better separation of water from oil. Operating temperature profile of oil train is controlled by production heater which utilizes steam for heating the crude oil. Normal operating temperature of production heater is 80 Deg C. When operating temperature of production heater is optimized at 74 Deg C, minimum B.S & W of crude oil achieved is 0.05 % at outlet Settling tank. Conventially emulsion breaking temperature of this crude is 75C. The following figure indicate the drop in temperature profile in the oil train from Production separators to settling Tanks. There were several questions that were raised regarding effect of BSW in crude vis-a-vas lower temperature profile of oil train. This effect can be correlated to the theory of How temperature affects the H20 solubility in alkanes which is presented in Oil and Gas journal. This reveals that at higher temperature solubility of water in crude oil is more pronounced. This is proven during optimization of temperature profile in oil train which is shown below. Figure-5: Temperature Profile of production Separator and settling tank during temperature drop from 80C to 74C 4

Figure-6: BS&W profile with reducing temperature Figure-7: BS&W profile with reducing temperature in settling tank train-2 Figure-8: BS&W profile with reducing temperature in settling tank train-3 5

References Carl L.Yaws; Preetam M. Rane.: Oil & gas journal How temperature affects water solubility in alkanes. Cairn energy India ltd documents. 6