Lamp Circuit Power Test Report

Similar documents
Product Compliance Andy Guest

Product Testing. Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013

In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

In Situ Temperature Measurement

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

Design and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology

LED Panel Light E830J

LED Outdoor Wall Light Series

NVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China.


Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C

10.6 Schedule of Accreditation

HEP Tech Co., Ltd. Company Profile

Technical Application Guide for UP-SHINE LED wall lamp UP-WL08-8W

Test Report issued under the responsibility of:

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

Cooper Lighting & Safety Limited Wheatley Hall Road, Doncaster, DN2 4NB, United Kingdom

T.Y.C. BROTHER IND. CO., LTD.

A low energy alternative to halogen which provide energy savings of around 90%

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Test Report No.: Page 2 of 14

CHINA DESK INNOVATING GREEN SOLUTION. CLEAN Inge Lehmanns Gade Århus C Denmark CLEAN. CLEAN Alsion Sønderborg Denmark

Safety Evaluation of Luminaires and Self Ballasted Lamps. 1

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

Technical Application Guide for UP-SHINE LED Panel Light

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Installation instructions

Reflector T2 and GU10 6,000 hours

GL BAL GLEDAL 150W B L A Z E AISL E L IGHT SPECIFICATION SHE ET OPTICAL SPECS ELECTRICAL SPECS CERTIFICATIONS OTHER DETAILS DIMENSIONS BEAM ANGLES

Dialight. DuroSite LED Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

diode led VOLANTE LED Flood Light 120V IP65 DI-VL-FL75W DI-VL-FL150W DI-VL-FL225W SPECIFICATION SHEET Item # Project

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

ADVANCED HIGH CEILING Tetriss Series

DISPLAY CHINA Shanghai New International Exhibition Center. In conjunction with

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER)

LMM-H04 Mass Air FLow Sensor

Technical Application Guide for UP-SHINE LED Panel Light

A flexible and affordable retail toolbox

Heat Pipe Heat Sink for Inverter Shanghai WTL Heatpipe Technology Co., Ltd All rights reserved WTL Heat pipe

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

Joint CELMA / ELC Guide on LED related standards

Issued to: Videl S.r.l. Località Ponti di Pievescola Casole d Elsa (SI)

2018 Midstream Lighting Product Catalog

Kitchen. A Revolution in Kitchen Light

TG-Light Optoelectronic Ltd.

LMM-H03 Mass Air FLow Sensor

OLUX LED IN-GROUND OSRAM. Datasheet

Light Walls HB-T001Q3 HB-T001R3

Technical Application Guide for UP-SHINE LED Panel Light

High Efficiency LED Panel Lights

MING ORDERING INFORMATION SAFETY WARNINGS T01-A INSTALLATION INSTRUCTIONS. 896mm CABINET 896mm K-77127T

Copy of marking plate:

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-AN

GB Translated English of Chinese Standard: GB

Technologies POWER SAVED IS POWER GENERATED LED STREET LIGHTS OUR PRODUCT

Zhengzhou Dingsheng Engineering Technology Co.,Ltd

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

LED-Track Spotlight. RIGGIANO Series

German Of ce. New Construction Plan

Technical Application Guide for UP-SHINE LED Panel Light

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

XI'AN KOSUN MACHINERY CO.,LTD.

RP SERIES THERMAL PROTECTORS

P5500 LED Architectural Downlighting

FOR PROFESSIONALS BY PROFESSIONALS *Suitable for hours daily, usage of the product. for 24 hours a day would void warranty

IECEx Certificate of Conformity

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

including the locations according to annex

CoreLine Recessed Spot the clear choice for LED

Lumination LED Luminaires

LUMILEDS LEDS - LIFETIME WARRANTY LIGHT DIRECTIONS - UP / DOWN / BOTH

lightengine generalluminairetm Light Engine Is The Very Core Of General Luminaire

Surface Mount Series Luminaires

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

1830., 1831., 1832., 1833., 1834., 1835., 1838., 1839.

Your Key to achieving C.E Marking Compliance

Technical Application Guide for UP-SHINE LED Frameless Panel Light

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

StoreFlux powerful LED accent lighting that blends perfectly in the store architecture

Service Manual. Pharmacy Refrigerator(2~8 ) Model:HYC-68/68A/118/118A. Picture:

I NTERIOR/OFFICE L IGHTING

Air-Quality Detection Module. User s Manual

TSEV01S01C10 SPECIFICATIONS

Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

Kasia lighting and design AOK. Series New LED Parking Lot & Area Light.

A UTO D EALERSHIP L IGHTING

Annex to declaration of accreditation (scope of accreditation) Normative document: EN ISO/IEC 17065:2012 Registration number: C 001

This annex is valid from: to Replaces annex dated: Imposed suspension for the crossed out activities as of

Specifications. Dimension (mm) Color Temperature Warm White Natural White Day White Pure White

Efficient curing processes with innovative UV-LED technology The Heraeus Noblelight UV-LED portfolio

Transcription:

Report : 3192007.50P Lamp Circuit Power Report To : GE (Lighting) Co., Ltd. Tel : -- Building E, Longcheer Park,.29, Jinye 1 st Fax : -- Road, 710065, Xi an, China Attn : James Guo Supplier : Sichuan Hongrui Electric Co., Ltd. Supplier address : Mianyang Export Processing Zone, High-tech Park, Mianyang, Sichuan Province, China Product type : ERR2P40C0LSGA ERR2P40C0LSGA4 ERR2P40C0LSGB ERR2P40C0LSGB4 Applicable standards : -- Samples picked by : Manufacture/Supplier Samples received in DEKRA Laboratory on : 2016-07 Amount of samples : 10 samples on : -- Clauses checked : Refer to the following Items s performed : LCP on each sample This Document includes : 6 pages Date of ing : 2016-07-18 DEKRA ing and Certification (Shanghai) Ltd 10/F, #250, Jiangchangsan Road building 16 Headquater Economy Park Shibei Hi-Tech Park, Zhabei District Shanghai, 200233, P.R. China Tel: +86 21 60567666 Fax: F + 86 21 6056 7555 Page 1 of 9

Report : 3192007.50P PRODUCT DATA Product description : LED street luminaire -- Type : ERR2P40C0LSGA -- ERR2P40C0LSGA4 ERR2P40C0LSGB ERR2P40C0LSGB4 Lamp Cap : -- -- Rated Wattage : 20 W -- Rated Luminousflux -- -- Rated : 220-240 V~ -- Rated CCT : -- -- Remarks te. All models have the same mechanical and electrical construction except different CCT or beam angle. Page 2 of 9 DEKRA ing and Certification (Shanghai) Ltd.

Report : 3192007.50P SAMPLE PICTURE Over view Overview Page 3 of 9 DEKRA ing and Certification (Shanghai) Ltd.

Report : 3192007.50P SAMPLE PICTURE LED module Page 4 of 9 DEKRA ing and Certification (Shanghai) Ltd.

Report : 3192007.50P TEST ITEMS NO CONTENTS 1 Electrical characteristics Measurements Page 5 of 9 DEKRA ing and Certification (Shanghai) Ltd.

Report : 3192007.50P TEST RESULTS DESCRIPTION Electrical characteristics Measurements Sample 1 Current LCP Power Buring on time 1 240.0 0,092 20,3 0,920 5 minutes 2 240.0 0,092 20,2 0,919 15 minutes 3 240.0 0,092 20,3 0,918 30 minutes Sample 2 Current LCP Power Buring on time 1 240.0 0,092 20,3 0,923 5 minutes 2 240.0 0,091 20,2 0,924 15 minutes 3 240.0 0,091 20,2 0,924 30 minutes Sample 3 Current LCP Power Buring on time 1 240.0 0,093 20,5 0,921 5 minutes 2 240.0 0,092 20,4 0,921 15 minutes 3 240.0 0,092 20,3 0,921 30 minutes Sample 4 Current LCP Power Buring on time 1 240.0 0,092 20,6 0,931 5 minutes 2 240.0 0,092 20,5 0,931 15 minutes 3 240.0 0,092 20,5 0,931 30 minutes Page 6 of 9 DEKRA ing and Certification (Shanghai) Ltd.

Report : 3192007.50P Sample 5 Current LCP Power Buring on time 1 240.0 0,092 20,3 0,922 5 minutes 2 240.0 0,091 20,3 0,921 15 minutes 3 240.0 0,091 20,3 0,921 30 minutes Sample 6 Current LCP Power Buring on time 1 240.0 0,091 20,2 0,924 5 minutes 2 240.0 0,091 20,2 0,924 15 minutes 3 240.0 0,091 20,2 0,924 30 minutes Sample 7 Current LCP Power Buring on time 1 240.0 0,093 20,5 0,923 5 minutes 2 240.0 0,093 20,5 0,923 15 minutes 3 240.0 0,092 20,4 0,922 30 minutes Sample 8 Current LCP Power Buring on time 1 240.0 0,092 20,4 0,919 5 minutes 2 240.0 0,092 20,3 0,919 15 minutes 3 240.0 0,092 20,3 0,919 30 minutes Page 7 of 9 DEKRA ing and Certification (Shanghai) Ltd.

Report : 3192007.50P Sample 9 Current LCP Power Buring on time 1 240.0 0,092 20,3 0,924 5 minutes 2 240.0 0,092 20,3 0,924 15 minutes 3 240.0 0,091 20,3 0,924 30 minutes Sample 10 Current LCP Power Buring on time 1 240.0 0,093 20,5 0,921 5 minutes 2 240.0 0,093 20,5 0,920 15 minutes 3 240.0 0,093 20,5 0,921 30 minutes te. The test samples were connected to the clean power source and supplied with voltage as listed in above test result description. The test samples were operated until the conditions of overall temperature equilibrium were established or at least 4 hours in stabilized operation with the supplied sources. Then the total power consumption measurements have been taken by power meter. Page 8 of 9 DEKRA ing and Certification (Shanghai) Ltd.

Report : 3192007.50P Please note that every statement made in this report is only valid for the samples tested and reported herein, Trusting to have informed you sufficiently, we remain, With best regards DEKRA ing and Certification (Shanghai) Ltd. Engineer name : Lihua Dai Engineer signature : Reviewed by : Wesley Xu Reviewer signature : ---------------------------------------------------the end--------------------------------------------------- Page 9 of 9 DEKRA ing and Certification (Shanghai) Ltd.