VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

Similar documents
VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

High efficiency, cast-iron gas boiler

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Peerless Boilers. Series MI. Residential Gas Boilers

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

Replacement parts EG/PEG

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Columbia Boiler Company

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Intelligent ways to save fuel heating your Commercial building. Caravan Modular Boiler System. CHS Multiple Boiler System

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Product Data BW9 WATER BOILER SERIES B

SLANT/FIN BOILERS TRADE PRICE BOOK

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

G124X - G234X - G334X Atmospheric Gas Boilers

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Peerless Boilers. Peerless Pinnacle. High Efficiency Stainless Steel Boilers

SECTION HEATING BOILERS

TECHNICAL SPECIFICATIONS

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

Warmth, efficiency, and total peace of mind.

User s Information Manual

ES2 Boiler 85% AFUE. Limited Lifetime Warranty! boiler control. option. option card. control system GREATER ENERGY SAVINGS. Cast Iron Water Boiler

G6RC Series TECHNICAL SPECIFICATIONS

Raypak Residential Products

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

95% SERIES 2 HEAT ONLY AND COMBINATION GAS WALL MOUNT BOILERS. Bringing. heat and hot water into perfect Balance

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

Revitalize Building Mechanical Systems (4619)

User s Information Manual

TABLE OF CONTENTS BRADFORD WHITE BOILERS

STEAM / GAS APPLICATION GUIDE

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Intelligent Heating for Your Home

TECHNICAL SPECIFICATIONS

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

G215 G315 Cast Iron Residential Boilers

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

U n i t H e at e r s

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

User s Information Manual

Suggested Specifications Prestige Excellence 110

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

TECHNICAL SPECIFICATIONS

FSB Series Gas-Fired Hot Water

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

LAARS PENNANT. Economical efficiency for greater savings

KN2/4 SERIES MASTER SPECIFICATION

LGB. Control Supplement. Gas fired boiler. Universal Control System. Series 2 Propane gas. Contents

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)

Boiler & Water Heater

Date: Project #: Engineer: Prepared By: Bid Date:

G34M Bulletin #69/ August 2003

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

GARAGE / WORKSHOP INFRARED HEATERS

Unmatched high efficiency product selection

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

Forced draught natural gas/propane burner

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS GAS BOILER

DIVISION FINNED WATER-TUBE WATER HEATERS

Contents. Hazard definitions

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

DIVISION FINNED WATER-TUBE WATER HEATERS

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

SLANT/FIN AUTOMATIC VENT DAMPER For Galaxy, Sentinel and Sentry Series Boilers INSTALLATION INSTRUCTION MANUAL AND TROUBLESHOOTING GUIDE

8+* Bulletin No November 1997

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GB Condensing Gas Boiler

MASCOT II. Gas-Fired Wall-Mounted Combination Boiler & Water Heater

PVE SERIES POWER VENTER SYSTEM MANUAL

Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

ECLIPSE INFORMATION GUIDE

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

DOM-5. Domestic Hot Water Heaters & Boilers

Transcription:

VICTORYII Cast-iron, power vent gas boiler VHS SERIES are available in a sealed combustion model VSPH VICTORY BOILERS AN IDEAL REPLACEMENT BOILER FOR OLDER HOMES. A PERFECT BOILER FOR NEW CONSTRUCTION.

VICTORYII High efficiency, cast-iron, power vent gas boiler Canada s best-built power vent gas boiler The VHS series: Economical home heating Versatile chimneyless design Near zero CO emissions Contractor-friendly Engineered for long, reliable life Domestic hot water with optional indirect-fired water heater 7,600 W to 52,800 W (60,000 to 80,000) Btuh CGA input Victory II offers new features for better performance, faster installation and easier service We have re-engineered the Victory power vent boiler with new features that improve its performance and make it exceptionally easy to install and service. Built with the highly successful Victory heat exchanger, burners and combustion chamber, the new Victory II boiler incorporates these substantial improvements: Horizontal flue outlet with 76 mm (3-inch) connector for better performance. Contractor-friendly features for faster installation, easier service. Near zero carbon monoxide emissions. World class performance, reliability and safety Advanced computer-aided design has assisted Slant/Fin engineers in designing the Victory II boiler to provide you with superior operating performance and long life. Boiler water heats rapidly, sending warmth through your home when you want it. High quality parts and components provide years of reliable heating comfort. Contractor-friendly features speed set-up and routine service. Built-in safety devices constantly verify proper operation and will shut down the boiler should they detect a malfunction. Clean combustion with near zero carbon monoxide emissions, under a broad range of operating conditions, makes the Victory II boiler particularly safe and ideal for closet or alcove installations. More new home builders are choosing hydronic heating and Slant/Fin high efficiency boilers.

Contractor-friendly features speed installation and reduce service time. Design innovations developed with the installer in mind make the Victory II easier to install and service. Boilers are fully packaged and ready to install. We even include additional flue system components, assembled with the boiler at the factory, saving field purchase cost and installation time. Horizontal flue discharge components are factory installed to save field assembly. 76 mm (3 ) flue connector with integral adapter for easy connection to stainless steel venting. Condensate drain is built into the flue discharge assembly. The drain design and location maximize its effectiveness in protecting boiler components from condensate. Drain tube for condensate is factory installed and pre-configured with water trap. Intermittent pilot spark ignition saves energy. Ignition control, Aquastat and gas valve are all Honeywell models with proven reliability. Junction box for line voltage facilitates placement and wiring of shut-off switch. Pressure switch is the same for all boiler sizes and all altitudes. Controls, circulator and other trim are top quality brand names that are widely available to heating professionals and easy to service. Flexibility in venting. A wide variety of options permit you to select the most practical and economical venting method. Consult the Victory II boiler installation instructions for complete details and restrictions on these venting options: For side wall or through the roof power (pressure) venting -- Easy, economical horizontal or vertical power venting with 76 mm (3") diameter AL29-4C stainless steel pipe. Some restrictions apply. Chimney vent -- with type B vent to the chinmey. VHS-90 through 80 boilers. Power vents horizontally through the wall or vertically through the roof. Also vents into a chimney (models VHS-90, VHS-20, VHS-50 and VHS-80 only).

Slant/Fin builds each Victory II boiler to the highest quality standards. Advanced design cast-iron heat exchanger extends boiler life. Every Victory II boiler is built with the highest quality components and is factory tested to help ensure many years of trouble-free operation. Cast-iron boiler sections are produced on state-of-the-art computerized machining centers to extremely critical tolerances with high repeatability to ensure a perfect leak free fit of one heat exchanger section to the next. Superior heat transfer properties of the castiron permit use of smaller, compact heat exchanger sections. The flue passage design, thermal pin pattern and consistent wall thickness ensure uniform heat transfer with less thermal strain and metal fatigue. Avoid leaks with durable metal push nipples. Only metal push nipples are used to join the cast-iron boiler sections. These push nipples expand and contract uniformly with the cast-iron sections. In many ordinary boilers, cheaper rubber or plastic gaskets are substituted for metal push nipples and could deteriorate and leak. Increased efficiency with insulated base assembly. The Victory II base assembly is constructed of heavy gauge aluminized steel. Thick refractory insulation surrounds the combustion chamber, minimizing standby losses and increasing efficiency. One piece stainless steel burners with special port construction prevent flame lift and flashback.

VICTORYII Engineered for excellence Horizontal flue discharge Power vent blower Insulated jacket Brand name controls Cast-iron heat exchanger Thermal pins Junction box Metal push nipples Gas valve Insulated base Long life stainless steel burners Rollout safety switch

Make your house a more comfortable home With a Victory II boiler at the heart of your heating system, you can enjoy deluxe heating comfort all around your home. A Victory II boiler can be installed to provide heating energy for any or all of these hydronic heating systems: 2 3 4 5 Zone heating with Slant/Fin hot water baseboard and individual room temperature controls. Slant/Fin hot water fan-convection heaters under cabinets or stairs. Hot water with a high volume Slant/Fin indirect-fired water heater. Pool or spa water heating with a Slant/Fin boiler and external heat exchanger. Warm, safe heating for bathrooms with Harmony Series towel warmers. 4 3 4 2 2 5 5 Zone your heating system for even greater fuel savings. By dividing your home into separate heating zones, you can save energy by heating only those areas you re using. Depending on your existing piping arrangement, it may be quite simple to zone your system.

Ratings VICTORYII POWER VENT CAST-IRON GAS BOILER RATINGS FOR NATURAL AND L.P. GAS MODEL NO. RATINGS FOR WATER CSA INPUT W Btuh VHS-60 7 600 60,000 4 700 50,000 2 600 43,000 84 287 83.4 VHS-90 26 400 90,000 22 000 75,000 9 000 65,000 27 433 82.8 VHS-20 35 200 20,000 29 300 00,000 25 500 87,000 70 580 82.2 VHS-50 44 000 50,000 36 600 25,000 32 000 09,000 23 727 82. VHS-80 52 800 80,000 43 700 49,000 38 00 30,000 254 867 82.0 Models VHS-30 and VHS-60 not currently available GROSS OUTPUT W Btuh NET RATING WATER W Btuh WATER m 2 Sq. ft. EFFI- CIENCY (A.F.U.E.) EP9900653 CANADIAN ENERG PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE MAXIMUM EQUIVALENT FLUE LENGTH 2 m (40 ft.) for all models. May differ for certain vent system manufacturers and altitudes. See installation instructions, Pub. VHS-40. Ratings must be reduced by 0% over 60 m (2000 feet) elevation. Net ratings shown include allowance from normal piping loss and pick-up load. For installations having unusual piping and pick-up requirements, additional allowances should be made before selecting the size of boiler required. Ratings are based on a piping and pick-up factor.5. Equipment PACKAGED WATER BOILER includes pre-assembled cast-iron heat exchanger with built-in air eliminator, base, pre-assembled insulated flush jacket, gas burners, gas orifices and manifold assembly, gas valve, electronic intermittent pilot ignition system, 2-way combination control (hi-limit and circulator relay), pressure relief valve (ASME),drain cock, inducer assembly, air flow proving switch, built-in condensate drain, trap and stainless steel vent pipe adapter, rollout safety switch. For propane, specify when ordering. Based on heat emission rate of 473 W/m 2 (50 Btu per square foot). Note: All boilers are tested and rated for capacity to meet or surpass Canadian minimum A.F.U.E. requirements. OPTIONAL EQUIPMENT: Circulator. Combustible floor kit. AL 29-4C stainless steel venting material. Dimensions 9 mm (3/4 ) TO AIR ELIMINATING SYSTEM PRESS./TEMP GAUGE CONTROL BOX INSTALL MANUAL MAIN SHUTOFF VALVES 524 mm (5 ) ABOVE FLOOR WHEN REQUIRED BY LOCAL CODE PRESSURE RELIEF VALVE 76 mm (3 ) DIA. VENT CONNECTOR 38 mm (-/2 ) FPT SUPPLY 722 mm (28-7/6 ) (SEE NOTE) JUNCTION BOX 773 mm (30-7/6 ) (SEE NOTE) 38 mm (-/2 ) RETURN TAPPING, 32 mm (-/4 ) CIR. FLANGE 78 mm (28-/4 ) (SEE NOTE) 502 mm (9-3/4 ) 9 mm (3/4 ) DRAIN A (JACKET) WIDTH B FULL WIDTH GAS VALVE (GAS TAPPING 3mm) (/2 ) GROUND JOINT UNION SEDIMENT TRAP (REQUIRED) LEFT END VIEW FRONT VIEW RIGHT END VIEW NOTE: Height dimensions increase by 44 mm ( 3 4") and depth increases to 565 mm (22 4") when combustible floor kit is used. WIDTH VHS-60 mm in. VHS-90 mm in. VHS-20 mm in. VHS-50 mm in. VHS-80 mm in. A 283 -/8 359 4-/8 435 7-/8 5 20-/8 587 23-/8 B 448 7-5/8 524 20-5/8 600 23-5/8 676 26-5/8 752 29-5/8 Supply water tapping 38 mm ( 2") Circulator return flange* 32 mm ( 4") * When not equipped with circulator, boiler 38 mm (-/2 ) return tapping. Crate dimensions: 880 mm (34-5/8 ) length, 572 mm (22-/2 ) width, 85 mm (33-/2 ) height. Gas tapping, 3 mm ( 2") natural or propane AL 29-4C is a registered trademark of Allegheny Ludlum Corp.

VICTORY II Cast-iron power vent gas boiler VHS SERIES Millions of homes are equipped with Slant/Fin hydronic heating. SLANT/FIN LTD/TEE, 6450 Northham Drive, Mississauga, ON L4V H9 Phone: (905) 677-8400 Fax: (905) 677-829 Order Desk Fax: (905) 677-905 www.slantfin.ca E-mail: orderdesk@slantfin.ca info@slantfin.ca Slant/Fin Corp. 2006. Printed in Canada 03/0. Publication No. VHS-0