Exhaust. a) For an arbitrary ambient temperature develop an expression for Q chiller in terms of M amb and M total.

Similar documents
MIT Architecture Fall 2008 L. Glicksman 4.42 FINAL Open Book

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

(Refer Slide Time: 00:00:40 min)

PLEASE READ AND FOLLOW THESE INSTRUCTIONS

A/C Cooling Load calculation and measurement

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Air Conditioning Clinic

Chapter 14, Problem 27.

Thermodynamics: Homework A Set 7 Jennifer West (2004)

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Mechanical Engineering Department Sheet (1)


REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

R07. Answer any FIVE Questions All Questions carry equal marks *****

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

AR/IA/UP 241 Lecture 5: Psychrometrics

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

Chapter 9. Refrigeration and Liquefaction

Partial Load Performance Of Refrigeration System

1 /35 2 /35 3 /30 Total /100

Pressure Enthalpy Charts

Homework #4 (group) Tuesday, 27 by 4:00 pm 5290 exercises (individual) Tuesday, 27 by 4:00 pm extra credit (individual) Tuesday, 27 by 4:00 pm

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Study on the Effect of Blade Angle on the Performance of a Small Cooling Tower

Chapter 8 Balances on Nonreactive Processes PSYCHROMETRIC CHART

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Homework Chapter2. Homework Chapter3

ENSC 388. Assignment #6

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

Introduction to Material and Energy Balance

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

UNIT 1 AIR CONDITIONING 1. Write the various psychometric processes? Explain any four processes with neat sketches?

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Technical Development Program

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Experimental Study of Two-phase Seperators for Vapor Compression Systems in Household Appliances

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Explanation of Cooling and Air Conditioning Terminology for IT Professionals

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

In the name of God. Jami Institute of Jami - Mehdi Rasti

Cold Storage Warehouse Dock Parametric Study

Energy Use in Refrigeration Systems

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Chapter 8. Production of Power from Heat

Department of Mechanical Engineering ME 322 Mechanical Engineering Thermodynamics

How Ground Source Heat Pumps Work

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 = 90 F. compressor. condenser. 5 evaporator 1. evap

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

Case 13 Food Storage & Processing Center

Comfort and health-indoor air quality

pdfmachine trial version

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Chapter 10. Refrigeration and Heat Pump Systems

Last exam / sista tent

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

HVAC Psychrometric Analysis to Avoid Moisture Problems

Psychrometrics: The Science of Moisture in Air. Presented by Tom Peterson, CEO and Founder. Climate by Design International

The Refrigeration Cycle

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Design of a Low capacity Evaporator of a Refrigeration Unit

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Evaporative-Cooled vs. Air-Cooled Chillers: Kirtland AFB Case Study

Desiccant Cooling with Solar Energy

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

The Refrigeration Cycle

Mechanical Engineering Laboratory

How about Savings in Time, Money, Energy and Longer Life?

Application Engineering

Performance Optimization of the Evaporative Condenser Design

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Modeling and Testing of an R-23/R-134a Mixed Refrigerant System for Low Temperature Refrigeration

ENGINEERING. Edition No. 13 October 2002

SERVICE ASSISTANT OVERVIEW FDSI Online Training

Transcription:

1. State 2 75 o F Exhaust M amb T amb State 3 Room Q chiller State 1 60 o F M total A room at steady state has a supply air stream of cool air entering at 60 o F. The lights, office appliances and people transfer heat to the air so that it leaves at 75 o F. Consider only sensible heat transfer for this problem, with all temperatures given as dry bulb temperatures. After the air leaves the room some is exhausted from the building. The remainder mixes with ambient air. The mixture is cooled by the chiller down to 60 o F. For ventilation requirements M amb must be at least 20 percent of the total flow rate. The total air flow rate to the room and the entering temperature, state 1, are held constant. The amount of ambient air can be varied from 20 percent up to 100 % of M total (with corresponding increases in the exhaust flow to keep the total flow constant). The temperature changes are small so C p can be considered constant. a) For an arbitrary ambient temperature develop an expression for Q chiller in terms of M amb and M total. b) As the ambient temperature varies between 50 o F and 85 o F what should M amb and M total be to minimize Q chiller? Show a diagram of the optimum M amb and M total versus T AMB. At different ambient temperature levels, e.g., 60, 75 o F, the strategy to minimize the chiller cooling requirement may change. This is known as an economizer cycle. Page 1 of 5

2. An office space is to be kept at 73 o F. If cool air is constantly supplied to the space at 60 o F and the space can be assumed to be at a uniform temperature, what is the required air mass flow in lb/hr and volume flow in CFM? The same flow of air continually leaves the space. The heat transfer into the space from the outside through an exterior wall is 16,000 BTU/hr. Internal "heat gains" in the office space can be taken as 2.5 W/ft 2 for office equipment and computers and 250 BTU/hr per person. Assume the space ft 2 is occupied by 40 people. The heat given due to people assume is only sensible heating, i.e., it neglects any evaporation or changes in the moisture level in the air. Assume steady state conditions prevail. The floor area of the office is 1500 ft 2. 2b. If all the heat gains are doubled what options are available for the cool air supply to keep the office space at 73 o F? What other factors must be considered in choosing an option? 3. A water to air heat exchanger is used to heat the air of a home interior. The air flow rate is 2000 lbm/hr; the air enters in steady flow at 70 o F and leaves the heat exchanger at 100 o F. Heating water enters at 130 o F and leaves at 110 o F. a) If the heat exchanger is operating in steady state and there is negligible heat loss from the outside casing of the exchanger to its surroundings what is the required water flow rate? b) Do you think it's possible to design a heat exchanger with a water temperature drop from 130 o F to 110 o F while the air outlet temperature is raised to 125 o F (for suitable air and water flow rates)? c) Is it possible to have an air outlet temperature of 135 o F with these same water temperatures? 4. An air conditioning system uses R-12 (Freon-12) as a working fluid. The flow rate of refrigerant is 1,000 lbm/hr and it is steady. The refrigerant is condensed in the condenser to saturated liquid at 120 o F. From the condenser, it passes through an expansion valve where the pressure is lowered and the outlet temperature is 20 o F. The expansion valve is insulated and there is no shaft work. After the expansion valve the Freon enters the evaporator where it receives heat at constant pressure corresponding to the saturation pressure of 20 o F. The heat transferred to the Freon in the evaporation provides the cooling to the air passing over the evaporator. a) Find the cooling capacity of the unit in BTU/hr if the outlet of the evaporator is saturated vapor. Find the cooling capacity in tons. Hint: Define a control volume around the evaporator and write the steady flow energy equation. b) Repeat part (a) if the outlet of the evaporator is super heated by 15 o F; that is, the vapor is heated at constant pressure to 15 o F above the saturation temperature. Assume the Freon-12 vapor is a perfect gas with C p equal to 0.15 BTU/lbm o F. Page 2 of 5

5. An open plan office is to be cooled by natural ventilation. The long axis of the building is aligned in the East-West direction. The depth in the North-South direction is 30 m with operable windows on both the North and South sides. With open windows and negligible air flow resistance in the interior, when the wind is from the South, the air velocity at the Southern window open area can be approximately related to the wind velocity as, V open area = 0.35 V wind. Assume the North side windows have the same open area as the South windows and there is an equal air flow out of the North side windows. The interior height is 3 m and there is a combined heat input due to lights, people and office equipment of 40 W/m 2 of floor area. a) What is the air change rate per hour, ACH, of the building interior as a function of the percent of the South façade used for open window area? The wind velocity is 1.5 m/s. b) Plot the temperature rise of the interior air as a function of the percent of the South façade used for open windows. The wind velocity is still 1.5 m/s. c) How can the building be kept cool when the wind velocity is reduced? d) Compare the performance of natural ventilation between the upper and lower floors of a high rise building. Page 3 of 5

6. An air conditioning system uses HFC 134a as a working fluid, the refrigerant. The flow rate of refrigerant is 500 kg/hr and it is steady. The refrigerant is condensed in the condenser to saturated liquid at 45 C. From the condenser, it passes through an expansion valve, flow resistance, where the pressure is lowered and the outlet temperature is 10 C. The expansion valve is insulated and there is no shaft work. After the expansion valve the refrigerant enters the evaporator where it receives heat at constant pressure corresponding to the saturation pressure of 10 C. The heat transferred to the refrigerant in the evaporation provides the cooling to the air passing over the evaporator. What is the enthalpy change of the refrigerant as it flows through the expansion valve? Find the cooling capacity of the unit in W and BTU/hr if the outlet of the evaporator is saturated vapor. Hint: Define a control volume around the evaporator and write the steady flow energy equation. T= 45 C Saturated Liquid 500 kg/s flow rate Condensor Compressor Flow Resistance Evaporator T=10C T=10 C, saturated vapor Page 4 of 5

7. MIT has a large number of fume hoods used for wet chemistry experiments. When the hood sashes are open the air velocity, sometimes called the face velocity, must be maintained at a safe level to prevent any dangerous fumes from escaping. The air drawn into the hoods comes from the air supplied to the room. This air must be heated to acceptable temperature levels for the lab occupants. For safety reasons, all of the air flow in such a building must be exhausted and none can be recycled, a once-through system. Use the instruments from class to measure the air flow rate in a new and an older hood as the window is closed. a) Estimate for one full sized hood at MIT the energy required to heat the air use during one winter day if the hood is left fully open for 24 hours. b) Use the instruments from class to measure the air flow rate in a new and older hood as the sash is closed. b) Estimate the amount of energy required to heat the air for the entire heating season if the hood is always open. c) Compare this to the energy required to heat an average single family house in Boston for the heating season. d) What steps would you recommend to save energy with the fume hoods at MIT? 8. A single story shopping mall has a floor plan 50m X 100 m. All energy is supplied by electricity. It has been designed with some advanced efficiency features so that the yearly energy use is 100 kwh/m2 of floor area. The architect proposes to use a wind turbine on the top of the building to supply all of the electricity. The wind turbine has a horizontal axis and has an average efficiency of 35 percent. a) Use the average wind speed in Boston (Logan Airport) to estimate what the diameter of a single turbine to meet the buildings energy? b) What are the practical issues with such a system? Page 5 of 5

MIT OpenCourseWare http://ocw.mit.edu 4.42J / 1.044J / 2.45J Fundamentals of Energy in Buildings Fall 2010 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.