FOT-100. Fiber Optic Temperature Sensor User s Manual P/N: I3A-110

Similar documents
MAJOR CONCERN on your GENERATORS?

T3/E3 Fiber Optic Line Drivers

OPERATION MANUAL MODEL & ACCELEROMETER

OPERATION MANUAL MODEL 805 ACCELEROMETER

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

For use with models: BP , BP , BP

BlueHeat AirTop 2000 Heater

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

TB4000 Temperature Controller

QMF MAINFRAME Installation Manual

Flame Rod Manual. Publication Rev A

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Greentrol Automation, Inc.

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Analog Melting Point Apparatus

Installation Instructions

OPERATION MANUAL MODEL 4610 ACCELEROMETER

Analog Room Pressure Monitor RPC Series

FSW300 Series Flow Switch

Installation Manual February Opticom Infrared System. Model 575 Confirmation Light Kit

KM300 Carbon Monoxide Detection System Installation Manual

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

OPERATION MANUAL Model 8011 & mA

LIGHTING CAUTION NEW LISMORE 9 ARM CHANDELIER W 110V

SEALING FIBER SEALING COMPOUND

4-Channel Contact Closure Fiber Link Card System

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

SIKA VK300 OR VK325 SERIES FLOW SWITCH Operating Manual

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

TS0 Series Portable Bulb and Capillary

TOUCHDOWN 48 CEILING FAN

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

6502B RF Distribution

Replacing a Gun Thermostat

ELSTON 52 CEILING FAN

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

SUTTON 52 CEILING FAN

Square D Clipsal Outdoor Light-Level Sensor

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Installation Instructions Part No , Part No Part No

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Model 5190-F Temperature/Humidity Probe

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Model 5190-E Temperature/Humidity Probe

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Model/Sprinkler Identification Numbers

C-Bus Four Channel General Input Unit Installation Instructions

Lifetime Limited Warranty

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Power Supply Display Module PSDM. Installation and Operation Manual

A measured step forward

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

30-YEAR LIMITED WARRANTY

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Heating and ventilation system,

Environmental Monitoring SmartSlot Card

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

LED IMPORTANT SAFETY INSTRUCTIONS

INTELLILEVEL AUTOMATIC WATER LEVELING SYSTEM FOR POOL AND SPA

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Installation Instructions

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

OPERATION MANUAL MODEL 8102 ACCELEROMETER

Prizmatix UV Torch. User Manual

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

ST. KITTS CEILING FAN

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

IR Intelligent Speed Dome Installation Manual

PolySprint. Operation Manual PSM-NIT-13004E. Follow this manual when using Nitta PolySprint Heat Press.

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

GAS MONITOR Model Model

PORTABLE DEW POINT MONITOR

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Duct Mount. Installation Instructions

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

STEAM WALLPAPER STRIPPER MODEL HTW5

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

MARTIN Insertable Dust Collector

MBCE-110/230UV Flame Sensor Module

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

VENTILATION FAN / LED LIGHT

Consignes d installation

Transcription:

FOT-100 Fiber Optic Temperature Sensor User s Manual P/N: 9411-25I3A-110

Safety Information The following manual contains information and warnings. They must be followed in order to keep the instrument in a working condition and ensure safe operation. Safety Symbols Warning - Danger - Identifies conditions or practices that could cause physical harm or death. Caution - Identifies conditions or practices that could result in a permanent loss of data or damage the measuring chain and/or other equipment to which it is connected. Important Information - Identifies important information, hints, and tips that must be read and applied. GND or earth ground Safety Precautions Warning - Danger Caution To use the described product correctly and safely, read and follow all safety instructions or warnings that appear throughout this manual. This product is intended to be used by qualified operators and maintenance personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and maintenance information before using this product. Install and use this product only as specified in this manual or the protection provided by this product might be impaired. When in doubt that safety protection has been impaired, make this product inoperative and secure it against any unintended operation. Exercise caution when working with voltage levels above 30 VAC RMS or 42 VDC. These voltage levels are potential shock hazards. Follow all generally accepted safety practices and procedures when working with or around electricity. Do not use this product in wet environments. NOTICE: Trademarks referenced herein are trademarks and registered trademarks of VibroSystM Inc. or third parties, and are the property of their respective owners. Third party trademarks are used for identification purposes only and shall not be construed as indicative of any relationship or endorsement between VibroSystM Inc. and the third parties. This manual is provided solely for guidance. VibrosystM Inc. takes no responsibility or liability for any damage caused by accidents, improper installation or misuse. Liability is limited to the repair and/or replacement of defective products. VibroSystM Inc. 2727 Jacques-Cartier E. Blvd, Longueuil, QC, Canada J4N 1L7 Phone: 450 646-2157 U.S. Toll-free Line: 800 663-8379 Email: techsupp@vibrosystm.com www.vibrosystm.com 2 FOT-100 - User s Manual 2016 VibroSystM Inc. All rights reserved

TABLE OF CONTENTS 1. FOT-100 FIBER OPTIC TEMPERATURE SENSOR OVERVIEW... 5 1.1 Description... 5 1.2 Main Unit Interventions... 5 2. FOT-100 SENSOR OPERATION... 6 2.1 Connecting the FOT-100 Sensor... 6 3. SENSOR INSTALLATION OVERVIEW... 7 3.1 Preliminary Considerations... 7 3.2 Installation Guidelines... 7 3.2.1 FOT-100 Sensor Head Installation... 7 3.2.2 FOT-100 Fiber Optic Cable Installation... 8 3.2.3 FOT-100 Signal Conditioner Installation... 8 FOT-100 - User s Manual 3

4 FOT-100 - User s Manual

1. FOT-100 FIBER OPTIC TEMPERATURE SENSOR OVERVIEW 1.1 Description The FOT-100 fiber optic temperature sensor is used to monitor temperature in generator end windings, isophase bus bars, exciter brushes, and knife switches in large motors or generators, These sensors are made of non-conductive materials and are immune to inductive effects and electromagnetic interference. FOT-100 sensors are suited for operation in hostile environments containing high voltage levels. These sensors detect temperature from their entire surface, front and back. They can be glued to solid objects and can also read ambient air temperature. FOT-100 Fiber Optic Temperature Sensor Sensor Head Sensing Face Sensing Zone PV041016B PV140715A Complete Measuring Chain Fiber Optic Integral Cable Conditioner Sensor Head PV041016A 1.2 Main Unit Interventions Sensors must be glued on the stator bars. Fiber optic cables must be routed inside the stator housing. Epoxy resins must be applied inside the generator. FOT-100 - User s Manual 5

2. FOT-100 SENSOR OPERATION 2.1 Connecting the FOT-100 Sensor The FOT-100 conditioner must first be connected to a 24VDC power supply and a receiving instrument with signal cable and M12 connector. It is important to confirm each component s functionality before proceeding with a permanent installation. The conditioner s outer shell must always be grounded. This is usually achieved by mounting the conditioner to an already grounded holder with a conductive surface. The cable shield must also be grounded. It is important to ground the shield on one end only to avoid creating a ground loop. If the M12 connector at the end of the cable is insulated from the shield, the shield must then be grounded on the acquisition unit side. However, if the M12 connector at the end of the cable is connected to the shield, attaching the cable to the already grounded FOT-100 conditioner will automatically ground the shield. In this case, the shield must not be grounded on the acquisition unit side. The illustration below shows the pinout for the M12 connector. FOT-100 Pinout Polarizing Key 2 5 3 4 1 PV300813A The signal cable provided by VibroSystM may be replaced by any cable having similar characteristics. The table below shows the color codes, designations and specifications for VibroSystM s signal cable. M12 Connector/Cable Pinout M12 Connector Pin # Color Designation Specification 1 Brown Power Supply +24 VDC 2 White Current Output 7.2-20 ma (proportional to sensor s full range) 3 Blue Common 0 V 4 Black Not Used 5 Not Used 6 FOT-100 - User s Manual

3. SENSOR INSTALLATION OVERVIEW Caution Since this product has a multitude of possible applications, only an installation overview is explained. In order to properly complete the installation, VibroSystM should be present during sensor installation and commissioning. Please contact VibroSystM for more information regarding specific applications. 3.1 Preliminary Considerations When choosing a location for the sensor head, cable and conditioner, the following considerations must be taken into consideration: The conditioner s case must be properly grounded (usually through its holder). The electric insulation rating between the sensor head and signal conditioner is up to 3KV/mm. The distance between the sensor head and conditioner: the fiber optic cable has a set length of 10 m [32.8 ft]. The M12 connector/cable s total length must not exceed 300 m [984 ft]. FOT-100 temperature sensors are designed and calibrated to operate strictly according to their respective specifications. The fiber optic cable between the sensor head and conditioner must not be cut or altered. 3.2 Installation Guidelines 3.2.1 FOT-100 Sensor Head Installation Caution Avoid applying mechanical stress (twisting, pressure) on the sensor head. This may damage the sensor and lead to erroneous readings Sensor performance depends on a proper installation. The closer the sensor head comes into contact with the monitored surface, the more accurate the readings will be. The use of a thermally conductive adhesive is recommended to maximize thermal transfer to the sensor head. It is also possible to encapsulate the sensor head in order to maximise transfer from only one direction. FOT-100 - User s Manual 7

3.2.2 FOT-100 Fiber Optic Cable Installation Caution The fiber optic cable must NEVER be bent below its minimum bending radius of 80 mm [3.15 ]. All bends must have smooth curves and follow the cable s natural curvature. While handling the cable, avoid twisting or pulling it against sharp edges. This may break the fiber optic strands inside. Mechanical stress on the fiber optic cable (crushing, kinking) can cause damage and cause false readings. All cables must be secured on their entire length. Ties should be used whenever possible. Excessive vibrations can cause irreversible damage to the sensor. 3.2.3 FOT-100 Signal Conditioner Installation The FOT-100 signal conditioners are typically mounted on a holder and their housing must be grounded. Proceed with the installation of each conditioner as shown in the following illustration. Detailed View of an FOT-100 Signal Conditioner Installation TOWARDS SENSOR HEAD Hex Nut* Jam Nut* *TIGHTENING TORQUE: 25 Nm [218 in-lb] M12 Socket M12 Connector / Signal Cable Holder with Conductive Surfaces PV021115B Important Information If it is not possible to mount the FOT-100 conditioner on a grounded holder, grounding must be provided by the M12 connector s shield. 8 FOT-100 - User s Manual