EDENTEC A Naieor Company HOME USE GUIDE. NELLCOR N-200 Pulse Oximeter. Your local NELLCOR Home Care Provider is: for the Nellcor Incorporated

Similar documents
WARNINGS AND CAUTIONS WARNING. Federal law restricts this device to sale by or on the order of a physician or other licensed practitioner.

OPERATOR S MANUAL. NELLCOR N-200 Pulse Oximeter

(Place Logo from Lab here)

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Track the truth. Give no false assurance. Do no harm. Nellcor SpO 2. Module for use with Philips IntelliVue * Patient Monitors

OGCF2002A User Manual

MXD3G User Manual Revision 0 July 29, 2013

HUG.ai 1/24/06 9:33:34 AM HUG.ai 1/24/06 9:33:34 AM C M Y CM MY CY CMY K

EXTERNAL CARDIAC AMBULATORY TELEMETRY

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

signal extraction pulse oximeter OPERATOR S MANUAL

Clofield Limited. Product Data Sheets. Paging System. Care Call. Preventative monitoring for homecare... Wireless alerting system for Carers

Achieva. Ve nt i l at or with Flow Acceleration Limit and Apnea Backup. User s Manual

GoodKnight H 2 O. User's Manual. Heated Humidifier. Ref. : M-146DFU00-20 Revision D

Model 900. Pulse Oximeter User s Manual

Guide, Quick Start, Short, X-100 System

SPECIFICATION FOR MULTIPARAMETER MONITOR

Operating manual Reusable Pulse Oximetry Sensors

ALLERGEN MIXING ASSISTANT

Operator s Manual. Models 8600FO and 8600FOM Pulse Oximeters. English

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

Patient/Family Education Teaching Protocol HeartMate II Left Ventricular Assist System

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Design Manual Installation Operation Maintenance

Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

BeneVision TM80 Telemetry Monitor

901-M / 901-ML. Pulse Oximetry System. Technical Information and Service Manual

SimplyGo Mini. User Manual REF R05 JH 08/01/2016 EN-INTL

QA16 Addressable System

MODEL 3X Series User s Manual

Patient Monitoring System YM5500. Service Manual

User Guide & Instructions

Blood Pressure Monitor

DR. CLARK FAR INFRARED HEATING PAD

Protect anything, anywhere, anytime.

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

Propaq LT Outline Train the Trainer

Operator s Manual. LifeSense LS1-9R. Vital Signs Monitor. Capnography/Pulse Oximeter

Sunbeam Tower Fan with Night Mode

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

National Broadband Network. User Guide. Includes important information about your NBN equipment

IDM4 CARAVAN ALARM. Operating instructions

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Getting Started. Genesis Touch System

AR280P Clockradio manual

Pioneer-R16 Gas Monitor Operator s Manual

with color display signal extraction pulse co-oximeter with Rainbow Technology OPERATOR S MANUAL

About this Manual. Statement. Release Date: January, 2014

OVHM80 Max Air Purifier

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

FUTURE CALL. Loud Ringer Light Box FC OWNER S MANUAL AND OPERATING INSTRUCTIONS

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

N-600. Pulse Oximeter Home Use Guide

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Operator s Manual. Avant Digital Pulse Oximeter. English

ANGELUS (Ver 2.03) Patient Monitoring System

MyGel Mini. Operating Manual Version 1.0. a division of. Electrophoresis System

TidalGuard HD. Handheld CO 2 / SpO 2 and CO 2 monitors. Operating Manual Rev. H (8/15)

HANDHELD PULSE OXIMETER

CORAL MANTA User Guide

TruSat Pulse Oximeter

Alarm System SECURE AS 302

Atlas Monitor Outline Train the Trainer

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Quick Reference Guide STAN S31 fetal heart monitor. Power ON/OFF. ST Analysis (Fetal ECG analysis)

SHARPER IMAGE. Professional Electrostatic Air Purifier with Permanent Stainless Steel Filter Model: and USE AND CARE GUIDE

Sidekick II Receiver Model # SK2-SS 418MHz

OctiveTech 300AH HANDHELD OXIMETER OPERATING INSTRUCTIONS

ARGUS VCM Vital Compact Monitor

About this Manual. Statement. P/N: Release Date: August 2010 Copyright EDAN INSTRUMENTS, INC All rights reserved.

Personal Assistance System Owner s Manual

Watchguard WGAP864 User Manual

User manual. Epi-Care mobile. Danish Care Technology ApS Energivej 3, DK-4180 Sorø version 1.15 Phone: Page 1 of 17

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

Victoreen Primalert 35 Area Radiation Monitor

User Guide. Fibre Connection. For installations after July 1st 2013 Includes information about your NBN equipment

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Frequently Asked Questions About Carbon Monoxide Detectors

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Simon XTi Quick Operation Guide

SERVICE MANUAL. Patient Monitor M30. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

Rad-87. Pulse CO-Oximeter OPERATOR S MANUAL

MiniAlarm Plus. Model MA-5000

Supervised Security System Owner's Guide

600 Series Owner s Guide

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

Using Your. Security System With LED Keypad S5030, S5031, S5032

Vitalmax 4000 CL Product Specifications

AMBIENCE Low Air Loss Mattress Replacement System

User Manual Watt Drop-In Induction Range. Model: DC /2017. Please read and keep these instructions. Indoor use only.

1.1 Setup Installation

600 Series Owner s Guide

PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL

X64 Wireless Training

Transcription:

HOME USE GUIDE for the NELLCOR N-200 Pulse Oximeter Your local NELLCOR Home Care Provider is: 24-hour hotline: J EDENTEC A Naieor Company Edentec Corporation 10252 Valley View Road Eden Prairie, MN 55344 U.S.A. 0 To contact Edentec's representative: in the United States, call 612 941-3006; outside the United States, call Edentec's local representative. Caution: Federal law (U.S.) restricts this device to sale by or on the order of a physician. 1992 Nellcor Incorporated 023466A-0492

EMERGENCY PHONE NUMBERS Post this list near your telephone. Ambulance 911 Police 911 Fire Department 911 Doctor Other Telephone Numbers Caregiver/Home Care Provider u

Table of Contents IMPORTANT 1 Intended Use 1 Your Home Care Provider 2 Definitions 2 What You Need to Know About the N-200 4 How the N-200 Works 6 Setting Up 10 Unpacking and Inspection 10 Where Not to Place Your Monitor 10 Pulse Sensors 11 Using a Pulse Sensor 11 Cleaning Your Pulse Sensor 11 The Parts of the Monitor 12 The Front of the Monitor 13 The Back of the Monitor 15 Using the Monitor 17 Alarms 21 Changing Settings 21 Changing from Adult to Neonatal Alarm Limits 21 Changing Alarm Limits 21 Turning the Audio Alarm Off Temporarily 22 Changing the Alarm Volume 23 Changing the Temporary Silence Period 23 Changing the Pulse Tone Volume 24 Changing Operating Mode 24 Using C-LOCK ECG Synchronization 26 If Using a Bedside ECG Monitor 26 If Using a Three-Lead ECG Cable 27 ni

Table of Contents (continued) If the ECG Signalis Lost 28 UsingTrend Memory 29 To Determine if the Memory is ON 29 To Turn the Memory ON 29 To Print Data Using a NELLCOR P200 Printer 29 ToSetor Change the Dateand Time 30 Using the Battery 31 To Connect the Interface/Powerbase 31 To Use the Battery 31 Care and Cleaning of the Monitor 32 Routine Care of the Monitor 32 Cleaning the Monitor 32 Troubleshooting 33 Troubleshooting 33 Status Messages 37 Appendix A: Standard Alarm Settings 38 IV

IMPORTANT It is essential thatyou, the Home User of this monitor, read and understand this Home Use Guide completely before using the monitor. This Home Use Guide provides you with basic reference information for proper use of the monitor. This manual is not a replacement for the N-200 Operator's Manual or for the training your home care provider or home provider company will provide for you. Read this manual carefully BEFORE using the monitor. Read all warnings and cautions (in boldface type). If you do not understand any part of the manual or the warnings and cautions, ask your home care provider or home provider company before using the monitor. Intended Use This monitor can be used for patients of all ages. It measures blood oxygen saturation levels and pulserate continuously. It sounds an alarm and an alarm light blinks when detected oxygen levels or pulse rate are above or below the alarm settings. The N-200 monitor may be used with or without ECG synchronization. This monitor does not distinguish between normal hemoglobin and abnormal hemoglobin. Therefore, this monitor should not be used in cases of carbon monoxide poisoning or any other situation that may decrease the hemoglobin's capability to carry oxygen. The N-200 monitor is not intended for use as an infant apnea (stopped breathing) monitor. If required, your patient's doctor will prescribe special equipment for detecting apnea. Federal law restricts this device to sale by or on the order of a physician.

Your Home Care Provider A qualified health care professional (called ahome care provider) is essential for providing adequate care for your patient. Your homecare provider will: Provide you with a monitor, pulse sensors, and accessories Train you how to use your monitor,sensors, and accessories Teach you how to respond to alarms If you have any questions, ask your home care provider. Alarm Battery Charger ECG Monitor Hemoglobin Home Care Provider Interface/Powerbase Monitor Oxygen Saturation Oxygen Transducers Definitions The tone you hear from the monitor and the indicatorthat flashes when an abnormal condition is detected. A device built inside your monitor that allows you to plug the monitor into a standard wall socket (3 prong) and recharge the monitor's internal battery. A monitor that displays electrical signals from the heart, through electrocardiogram (ECG), as heartrate (not pulse rate). The part of the red blood cell that carries oxygen. Health care professional who supplies the monitor, provides training on its use, and does follow-up and maintenance checks. The section of the monitor that allows AC electrical power to be used to run the monitor. The part of the pulse oximetry system that receives signals from the detector on the pulse sensor. The system then measures, displays, and compares the readings to the alarm settings. The monitor sounds an alarm when the oxygen saturation level or pulse rate are outside the alarm settings. A measure of the amount of oxygen actually carriedin the blood, compared to the amountit could carry. See pulse sensor.

Patient Module Perfusion Pulse Oximetry Pulse Sensor Synchronization Standby The connecting cable between the pulse sensor and the monitor. If using ECG equipment, the patient module may also be used to synchronize the saturation measurement with the ECG signal. The amount of blood in a particular area, such as the arm or leg. Poor perfusion indicates that very little blood flow occurs in the area. A method of determining oxygen saturation levels. The part of the pulse oximetry system that actually sends and receives the light. Using signals from more than one source and using them to synchronize the pulse oximeter's oxygen measurement. This enhances oxygen measurement, especially when the patient has poor perfusion or is moving around. A condition controlled by the ON/STDBY switch that turns off monitor functions, but allows battery charging and retains data stored in memory.

What You Need to Know About the N-200 (Safety Information) Read this manual carefully BEFORE using the monitor. Read all warnings and cautions (in boldface type). NEVER USE A MONITOR THAT YOU SUSPECT IS NOT WORKING CORRECTLY. Contact your home care providerimmediately to have the monitor tested or replaced. The N-200 should be plugged into awall outletat all times. The battery is only for backup in case of power failure. The battery provides operation for up to 90 minutes if fully charged. After the batteryhas discharged, the monitor turns itself off automatically. Always use NELLCOR pulse sensors. Using any other pulse sensor may cause the monitor not to work correctly. Incorrect application or use of the pulse sensors may cause tissue damage or false readings. Do NOT wrap the pulse sensors too tightly orapply extra tape. Check the sensor site every 4 hours for redness or swelling. Do not place the sensor somewhere it is not intended to be used. Excessive light (such as fluorescent lamps or directsunlight) may cause the monitor not to work correctly. If this happens, cover the sensor area with a piece of dark cloth to block the extra light. DO NOT reuse disposable pulse sensors. Dispose of them as instructed. DO NOT get pulse sensors wet or they may not work correctly. DO NOT change the alarm settings that your home care provider has directed you to use. Check the settings at least once a day or whenever you turn the monitor on. When the monitor is turned off and then back on, all alarm settings return to their standard values (see Appendix A). If necessary, return settings to the values directed by your home care provider. Never turn the audio alarm off when you are not in the room with the patient. If you do so you may not know when an alarm condition occurs.if you disable the alarm, be sure to turn it back on before leaving the room. Be sure you can hear the alarm from wherever you are in the house. For continued protection from fire, replace fuses only with those of the same type and rating. Shock hazard. DO NOT remove the cover of the monitor.

DO NOT place the monitorin water or any otherliquid. Do NOT use abrasive or caustic cleaners on the monitor or pulse sensors. Remove the pulse sensor before bathing the patient.

How the N-200 Works Your patient's doctor has decided to place your patient on adevice called a pulse oximeter. This device uses a technique called pulse oximetry to measure the amount of oxygenin the blood continuously. Pulse oximetryrequires three parts: anoxygen transducer (called a pulse sensor in this manual), a patientmodule, and an oximeter (called a monitor in this manual). Refer to Figure 1. Pulse Sensor Monitor Patient Module I IH)^ a w SB US Figure 1: The pulse sensor, patient module, and monitor are the three parts of a pulse oximetry system. ECG equipment is optional. The plastic reusable sensor gently sandwiches an area of thebody thathasa lotof blood flow near the surface. Reusable plastic sensorsmay be used on a finger or an adulfs toe. Disposable adhesivesensors may be used on thebridge of the nose, a toe, or abab/s foot.

Pulse Sensor Tissue containing pulsatile biood Figure 2: The pulse sensor gently sandwiches an area of the body that has a lot of blood flow near the surface. A typical application of the reusable plastic sensor is shown above. Infrared light (which you cannot see) and red light are sent from one side of the pulse sensor to the other side through the skin. When this light passes through the blood, some light is absorbed by the hemoglobin (the part of the blood cell that carries oxygen). The light not absorbed is measured by a detector on the other side of the sensor (see Figure 3). Light source Pulse Sensor & Detector Tissue containing pulsatile blood Figure 3. Some of the light is absorbed when it passes through the blood. The remaining light reaches the detector on the other side of the sensor.

The pulse sensor then sendsinformation on the amount of lightnot absorbed through the patient module to the monitor (see Figure 4). Themonitor calculates the oxygen saturationlevel and the pulse rate, displays the readings, and compares them to the alarm settings. Pulse Sensor Monitor»S bnrabt Figure 4: The sensor sends information to the monitor through a patient module. The monitor then computes the amount of oxygen in the blood and compares it to the alarm settings. If either the oxygen saturationor the pulse rate goes above or below the alarm settings, an alarm sounds from a loudspeaker in the bottom of the monitor and a light flashes on the monitor's front panel, (see Figure 5). Your patient's doctor determines these alarm settings. If you turn the monitor off and backon, be surethat you checkthe alarm settings and adjust them if necessary. Monitor G\l fis Alarm tone sounds Figure 5: An alarm occurs when either the oxygen saturation In the blood or the pulse rate goes above or belowthe limits. The monitor may have problems making measurements if your patient has poor blood flow or is moving around a lot. Your home care provider will help to determine this and obtain the correct patient module for ECG synchronization (see Figure 6). 8

wajleoa " i plug ECG cable into patient module Figure 6: A three-lead ECG cable may be connected to the patient moduleto allow ECG and pulse sensor signals to be synchronized. If you are using an ECG monitor in addition to the N-200, it may be possible to use a synchronization signal from the ECG monitor to synchronize the N-200's measurements to the patient's heartbeat. Ask your home care provider to determine if this can be done. WARNING: This monitor acts as an early warning device. You must ACT when the alarm sounds. The monitor cannot act for you. The monitor cannot prevent your patient's oxygen saturation levels from falling below a safe level or your patient's heart from stopping. It will, however, warn you of situations that may be life-threatening. You must respond to alarms immediately.

Setting Up Unpacking and Inspection Caution: Notify the carrier if the monitor shipping carton is damaged. Do NOT use a damaged monitor. Carefully unpack the monitor and its accessories. The packages should contain: one N-200 monitor one interface/powerbase one hospital-grade power cord one patient module (N-200 mini patient module or N-200 patient module with ECG) pulse sensors (also called oxygen transducers) this home use guide If any of these items is missing, contact your home care provider immediately. Note: Always have an extra pulse sensor available. If you do not have an extra, contact your home care provider. Where Not to Place Your Monitor Follow these guidelines for placing your monitor: WARNINGS DO NOT place the monitor in the crib or bed with your patient. DO NOT place the monitor on a carpeted floor. The alarm may be muffled by the carpeting. DO NOT place the monitor on or near electrical equipment such as television sets, radios, microwave ovens, or electric heaters. These may affect the monitor and cause it to work improperly. DO NOT place containers of liquid on or near the monitor. Liquids spilled on the monitor may cause it to work improperly. DO NOT place the monitor on or near a vaporizer. Moisture in the air may condense on the monitor and cause it to work improperly. Place the monitor where the pulse sensor can reach your patient easily. Be sure that you can hear the monitor alarm from anywhere in the house. 10

Pulse Sensors WARNINGS Always use NELLCOR pulse sensors. Using any other pulse sensor may cause the monitor not to work correctly. Incorrect application or use of the pulse sensors may cause tissue damage or false readings. DO NOT wrap the pulse sensors too tightly or apply extra tape. Check the sensor site every 4 hours for redness or swelling. DO NOT place the sensor somewhere it is not intended to be used. Excessive light (such as fluorescent lamps or direct sunlight) may cause the monitor not to work correctly. If this happens, cover the sensor area with a piece of dark cloth to block the extra light. Remove the pulse sensor before bathing the patient DO NOT allow the pulse sensor to get wet. Using a Pulse Sensor Nellcor provides several types of pulse sensors (also called oxygen transducers). Some pulse sensors are disposable and others can be reused. Your home care provider has determined which is the best type of pulse sensor for your patient. Follow your home care provider's instructions on how to use the pulse sensor. Cleaning Your Pulse Sensor Ifyou are using a reusable pulse sensor: Clean the pulse sensor with a disinfectant, such as 70% isopropyl alcohol. Gently wipe the sensor with a damp cloth. Ifyou are using disposable pulse sensors: DO NOT clean disposable pulse sensors. DO NOT get disposable sensors or the tape wet. Dispose of pulse sensors as directed by your home care provider. 11

The Parts of the Monitor The N-200 monitor can be used with any model NELLCOR pulse sensor. The monitor should be run only on AC electrical powerby plugging the hospital-grade power cord into a standard, grounded wall outlet (3 slots). In caseof power failure, the monitormay be run on its internal battery for up to 90 minutes. The internal batteryis recharged when the monitor is connected to AC power. It takes 14hours to recharge fully after operatingon battery power. The N-200 monitor must be used with one of the following patient modules: N-200 patient module with ECG N-200 mini patient module The momtor will not work with any other kind of patient module or without one. Do not attempt to connect a pulse sensor to any connector on the monitor's rear panel. The N-200 patient module with ECG may be connected to ECG leads connected to the patient; N-200 mini patient module cannot. (If you wish to use an ECG signal with the N-200 mini patient module, an ECG lead from a bedside ECG monitor must be connected to the ECG IN/OUT connector on the backof the N-200 monitor.) No matter which patient moduleis used, themonitor will sound anaudible alarm and flash a light when the oxygen levels (detected by light absorption) fall below or go above the alarm settings. The monitor will also alarm if the pulse rate goes above or falls below the alarm settings. Besides the alarm functions, the N-200 monitor saves 12 hours of trend information. This information can be printed on a printer having a serial input. 12

Technical Update Number 2 Battery Capacity Testing for NELLCOR Pulse Oximetry Products Nellcor Technical Updates are intended to inform Biomedi cal and Clinical Engineers oftimely service and maintenance issues regarding Nellcor products. These updates are distrib uted to customers who own the identified products. Addi tional copies mayberequestedbycontacting NellcorTechni cal Services at 1-800-NELLCOR(inside theu.s.a.), ornellcor corporate offices at 510 887-5858. Instruments: Description: Battery Capacity Test, N-200: NELLCOR N-100, N-200, and N-250 pulse oximeters and N-1000 multi function monitor. NELLCOR monitors are equipped with sealed lead-acid batteries. Electrical specifications for each monitor can be found in the operator's manuals. Battery capacity decreases over time due to several factors such as tempera ture, depth of discharge and number of charge/discharge cycles. Replacing the battery periodically ensures battery operation when needed. A periodic battery capacity check is also recommended. The time interval for this check is left to the discretion of the customer. Depending on how the unit is used, the customer may wish to perform a battery check as often as every 6 months. This check should also include inspection of the batteries' physical condi tion. Any batteries with signs of leakage or corrosion should be replaced. Refer to the applicable "Battery Capacity Test" below for instructions on testing batterycapacity. Regardless of periodic test results, Nellcor recom mends replacement of lead-acid batteries every 2 years. Replacement batteries can be purchased through Nellcor Technical Services. This test requires that the unit be fully charged for 14 hours. Use the following procedure: 1. Place the N-200 in either ON or STDBY mode, ensuring that the instrument is plugged into an operational, properly grounded AC outlet. (Ifan N-200 220-240 V monitor is being tested, the MAINS switch on the powerbase rear panel must be on.) 2. Charge the battery for a minimum of 14 hours. 3. Test the N-200 for operation in the battery mode (unplugged from AC power). The operating time in battery mode must be a minimum of 45 minutes.

Battery Capacity Test, N-250: This test requires that the unit be fully charged for 14 hours. Use the following procedure: 1. Place the N-250in either ON or STDBY mode, ensuring that the N-50interface/ECG momtor is plugged into an operational, properly grounded AC outlet and the mains switch on the N-50 rear panel is in the ON position. 2. Charge the battery for a minimum of 14hours. 3. Test the N-250 for operation in the battery mode (unplugged from AC power). The operating time in battery mode mustbe a minimum of 45 minutes. Battery Capacity Test, N-100: This test requires that the unitbe fully charged for 8 hours. Use the following procedure: 1. Place the N-100 in either the ON or STDBY mode, ensuring that the instrument is plugged into an operational, properly grounded AC outlet. (If an N-100 220-240 V unit is being tested, the MAINS switch on the rear panel must be on.) 2. Charge the battery for a rninimum of 8 hours. 3. Test the N-100 for operation in battery mode (unplugged from AC power). The operating time in battery mode must be a minimum of 60 minutes. Battery Capacity Test, N-1000: This test requires that the unit be fully charged for 14 hours. Use the following procedure: 1. Place the N-1000 in either ON or STDBY mode, ensuring that the instru ment is plugged into an operational, properly grounded AC outlet. 2. Turn on the N-1000 MAINS switch and verify that the rear-panel AC power indicator illuminates. 3. Charge the battery for a minimum of 14 hours. 4. Test the N-1000 for operation in battery mode (unplugged from AC power). The operating time in battery mode must be a minimum of 15 minutes before the monitor powers down. Note: The message "WARNING: POWER DOWN IS IMMINENT DUE TO LOW BATTERY VOLTAGE" appears before actual power-down; the 10-minute battery test period applies to monitor power-down, not appearance of message. If any unit does not meet the specified battery operatingtime,further testing or repair may be necessary. Only qualified service personnel or Nellcor repair facilities are recommended for testing or repair. If you encounter problems or have questions regarding this update, contact Nellcor Technical Services at 1-800-NELLCOR. NELLCOR isatrademark of Nellcor Incorporated. 1992 Nellcor Incorporated. Allrights reserved. 027016B-0194 Nellcor Incorporated Pleasanton, CA 94588 U.S.A. Toll free 1-800-NELLCOR Fax 510 463-4420

Technical Update Number 2 Battery Capacity Testing for NELLCOR9 Pulse Oximetry Products Nellcor Technical Updates are intended to inform Biomedi cal and Clinical Engineers oftimely service and maintenance issues regarding Nellcor products. These updates are distrib uted to customers who own the identified products. Addi tional copiesmaybe requestedbycontacting NellcorTechni cal Services at1-800-nellcor(inside theu.s.a.),ornellcor corporate offices at 510 887-5858. Instruments: Description: Battery Capacity Test, N-200: NELLCOR N-100, N-200, and N-250 pulse oximeters and N-1000 multi function monitor. NELLCOR monitors are equipped with sealed lead-acid batteries. Electrical specifications for each monitor can be found in the operator's manuals. Battery capacity decreases over time due to several factors such as tempera ture, depth of discharge and number of charge/discharge cycles. Replacing the battery periodically ensures battery operation when needed. A periodic battery capacity check is also recommended. The time interval for this check is left to the discretion of the customer. Depending on how the unit is used, the customer may wish to perform a battery check as often as every 6 months. This check should also include inspection of the batteries' physical condi tion. Any batteries with signs of leakage or corrosion should be replaced. Refer to the applicable "Battery Capacity Test" below for instructions on testing battery capacity. Regardless of periodic test results, Nellcor recom mends replacement of lead-acid batteries every 2 years. Replacement batteries can be purchased through Nellcor Technical Services. This test requires that the unit be fully charged for 14 hours. Use the following procedure: 1. Place the N-200in either ON or STDBY mode, ensuring that the instrument is plugged into an operational, properlygrounded AC outlet. (Ifan N-200 220-240 V monitor is being tested, the MAINS switch on the powerbase rear panel must be on.) 2. Charge the battery for a minimum of 14 hours. 3. Test the N-200 for operation in the battery mode (unplugged from AC power). The operating time in battery mode must be a minimum of 45 minutes.

Battery Capacity Test, N-250: This test requires that the unit be fully charged for 14 hours. Use the following procedure: 1. Place the N-250 in either ON or STDBY mode, ensuring that the N-50interface/ECG monitor is plugged into an operational, properly grounded AC outlet and the mains switch on the N-50rear panel is in the ON position. 2. Charge the battery for a minirnum of 14 hours. 3. Test the N-250for operation in the battery mode (unplugged from AC power). The operating time in battery mode mustbe a minimum of 45 minutes. Battery Capacity Test, N-100: This test requires that the unit be fully charged for 8 hours. Use the following procedure: 1. Place the N-100 in either the ON or STDBY mode, ensuring that the instrument is plugged into an operational, properly grounded AC outlet. (Ifan N-100 220-240 V unit is being tested, the MAINS switch on the rear panel must be on.) 2. Charge the battery for a minimum of 8 hours. 3. Test the N-100 for operation in battery mode (unplugged from AC power). The operating time in battery mode must be a minimum of 60 minutes. Battery Capacity Test, N-1000: This test requires that the unit be fully charged for 14 hours. Use the following procedure: 1. Place the N-1000 in either ON or STDBY mode, ensuring that the instru ment is plugged into an operational, properly grounded AC outlet. 2. Turn on the N-1000 MAINS switch and verify that the rear-panel AC power indicator illuminates. 3. Charge the battery for a minimum of 14 hours. 4. Test the N-1000 for operation in battery mode (unplugged from AC power). The operating time in battery mode must be a minirnum of 15 minutes before the monitor powers down. Note: The message "WARNING: POWER DOWN IS IMMINENT DUE TO LOW BATTERY VOLTAGE" appears before actual power-down;the 10-minute battery test period applies to monitor power-down, not appearance of message. If any unit does not meet the specified battery operating time, further testing or repair may be necessary. Only qualified service personnel or Nellcor repair facilities are recommended for testing or repair. If you encounter problems or have questions regarding this update, contact Nellcor Technical Services at 1-800-NELLCOR. NELLCOR is a trademark of Nellcor Incorporated. 1992Nellcor Incorporated. All rights reserved. 027016B-0194 Nellcor Incorporated Pleasanton, CA 94588 U.S.A. Toll free 1-800-NELLCOR Fax 510 463-4420

LJLCOR June 1,1992 Dear N-200 User: Subject: Component update for the NELLCOR9 N-200 pulse oximeter. Nellcor Incorporated has elected to change the battery pack in the monitor portion of the N-200. Although the new battery pack has a lower charge capacity, it was chosen for its consistent performance. The effect of this lower capacity is a reduction in the instrument's battery operation from 120minutes to 90 minutes. The charge capacity of lead-acid batteries is highly variable. Testing has shown that the actual performance of a battery in good condition may exceed the new specification by as much as 45 minutes. Nellcor has specified 90 minutes as the typical battery operation period at the time of shipment. Storage may decrease battery capacity, and several com plete charge cycles may be required to restore the battery to its rated capacity. Nellcor monitors are equipped with sealed lead-acid batteries. Battery capacity decreases over time due to several factors such as temperature, depth of discharge, and number of charge/discharge cycles. Replacing the battery periodically ensures battery operation when needed. A periodic battery capacity check is also recommended. The time interval for this check is left to the discretion of the customer. Depending on how the unit is used, the customer may wish to perform a battery check as often as every 6 months. This check should also include inspection of the batteries' physical condition. Any batteries with signs of leakage or corrosion should be replaced. Regardless of periodic test results, Nellcor recommends replacement of lead-acid batteries every 2 years. Replace ment batteries can be purchased through Nellcor's Technical Services Department. This notification must be included with the information in the N-200 operator's manual. Attach it accordingly. If you have any questions or concerns regarding the N-200 pulse oximeter, contact Nellcor's Technical Services Department at 1-800-NELLCOR or 510 887-5858. In Europe, contact Nellcor B.V., +31.73.42.6565. Sincerely, Technical Services 026332A-0692

ELLCOR June 1,1992 Dear N-200 User: Subject: Component update for the NELLCOR9 N-200 pulse oximeter. Nellcor Incorporated has elected to change the battery pack in the monitor portion of the N-200. Although the new battery pack has a lower charge capacity, it was chosen for its consistent performance. The effect of this lower capacity is a reduction in the instrument's battery operation from 120 minutes to 90 minutes. The charge capacity of lead-acid batteries is highly variable. Testing has shown that the actual performance of a battery in good condition may exceed the new specification by as much as 45 minutes. Nellcor has specified 90 minutes as the typical battery operation period at the time of shipment. Storage may decrease battery capacity, and several com plete charge cycles may be required to restore the battery to its rated capacity. Nellcor monitors are equipped with sealed lead-acid batteries. Battery capacity decreases over time due to several factors such as temperature, depth of discharge, and number of charge/discharge cycles. Replacing the battery periodically ensures battery operation when needed. A periodic battery capacity check is also recommended. The time interval for this check is left to the discretion of the customer. Depending on how the unit is used, the customer may wish to perform a battery check as often as every 6 months. This check should also include inspection of the batteries' physical condition. Any batteries with signs of leakage or corrosion should be replaced. Regardless of periodic test results, Nellcor recommends replacement of lead-acid batteries every 2 years. Replace ment batteries can be purchased through Nellcor's Technical Services Department. This notification must be included with the information in the N-200 operator's manual. Attach it accordingly. If you have any questions or concerns regarding the N-200 pulse oximeter, contact Nellcor's Technical Services Department at 1-800-NELLCOR or 510 887-5858. In Europe, contact Nellcor B.V., +31.73.42.6565. Sincerely, Technical Services 026332A-0692

ELLCOR June 1,1992 Dear N-200 User: Subject: Component update for the NELLCOR9 N-200 pulseoximeter. Nellcor Incorporated has elected to change the battery pack in the monitor portion of the N-200. Although the new battery pack has a lower charge capacity, it was chosen for its consistent performance. The effect of this lower capacity is a reduction in the instrument's battery operation from 120 minutes to 90 minutes. The charge capacity of lead-acid batteries is highly variable. Testing has shown that the actual performance of a battery in good condition may exceed the new specification by as much as 45 minutes. Nellcor has specified 90 minutes as the typical battery operation period at the time of shipment. Storage may decrease battery capacity, and several com plete charge cycles may be required to restore the battery to its rated capacity. Nellcor monitors are equipped with sealed lead-acid batteries. Battery capacity decreases over time due to several factors such as temperature, depth of discharge, and number of charge/discharge cycles. Replacing the battery periodically ensures battery operation when needed. A periodic battery capacity check is also recommended. The time interval for this check is left to the discretion of the customer. Depending on how the unit is used, the customer may wish to perform a battery check as often as every 6 months. This check should also include inspection of the batteries' physical condition. Any batteries with signs of leakage or corrosion should be replaced. Regardless of periodic test results, Nellcor recommends replacement of lead-acid batteries every 2 years. Replace ment batteries can be purchased through Nellcor's Technical Services Department. This notification must be included with the information in the N-200 operator's manual. Attach it accordingly. If you have any questions or concerns regarding the N-200 pulse oximeter, contact Nellcor's Technical Services Department at 1-800-NELLCOR or 510 887-5858. In Europe, contact Nellcor B.V., +31.73.42.6565. Sincerely, Technical Services 026332A-0692