Installation and Maintenance Instructions. Model Saf-T Pipe. Heavy Duty Black Stove Pipe. (Also known as a Connector Pipe)

Similar documents
INSTALLATION INSTRUCTIONS

Installation & Maintenance Instructions

INSTALLATION INSTRUCTIONS

DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

Installation and Maintenance Instructions

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

Installation Instructions

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

Vertical Vent Kit for Bosch AquaStar Models GWH-1600H and GWH-1600P only. INSTALLATION INSTRUCTIONS for H/P VVT vent kit 5" GALVANIZED TYPE B GAS VENT

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

DuraTech. Installation Instructions. Combustion Air System

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Pellet Vent INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING MANUAL

MODEL CF CEILING SUPPORTED CHIMNEY

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

M1200 Series Limited Warranty Dependability Promise

USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

INSTALLATION INSTRUCTIONS

October 2016 Humidex GVS-SD Rev. 1.2En. Owner s Manual. Manufactured by: Clairitech Innovations Inc Ohio Rd. Boudreau-West, NB Canada E4P 6N4

Mighty Venter Power Vent System

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Pellet Vent INSTALLATION INSTRUCTIONS

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

VP Pellet Pipe. For pellet burning stoves. FEATURES

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

MaxLite LED MICRO-T PANEL

FIREPLACE INSERT, MODEL VOLCANO PLUS OWNER S MANUAL - INSTALLATION - OPERATION. Save These Instructions for Future Reference.

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

INSTRUCTION MANUAL HS-229G

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

DUST FREE CARBON Whole House Air Purifier

Compact Equipment Warranty Policy

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

LDVPV58 Linear Power Vent System

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

Installation and service must be provided by a qualified installer, service agency or the gas supplier.

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

OWNERS MANUAL LIBERATOR ROCKET HEATER Model: RMH-1

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Pellet Stove. Flex Pipe. Appliance Connector

TrueClean ToteCleaner

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

ASSEMBLY INSTRUCTIONS

MaxLite LED High Bay Fixtures

LIMITED LIFETIME WARRANTY

Installation and Maintenance Instructions

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

OPERATION, SERVICE & PARTS MANUAL

CHAPTER 8 CHIMNEYS AND VENTS

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

NorthlineExpress.com Toll-Free


Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

Bathroom Exhaust Fan/Fluorescent Light Combination

A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS

READ AND SAVE THESE INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

Corn Flame Energy Corn Stove Model 3000

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

Torrena 42 Ceiling Fan

Design Criteria. Installation

Camarillo 52 Ceiling Fan

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

September 2016 Humidex GVS-H Rev. 2.2En. Owner s Manual. Manufactured by: Clairitech Innovations Inc Ohio Rd. Boudreau-West, NB Canada E4P 6N4

IMPORTANT. World-wide Patents. VIGIA is a trademark of Col-Ven S.A.

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

TrueClean ToteCleaner

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

First Year Limited Warranty for Residential Use Condensing Water Boilers (Includes Heat Exchanger and Component Parts)

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Bathroom Exhaust Fan/Fluorescent Light Combination

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

YOUR AROMATHERAPY DIFFUSER

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

INSTALLATION AND OPERATION INSTRUCTIONS

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

SF180 Installation Instructions

CHAPTER 8 CHIMNEYS AND VENTS

Transcription:

Installation and Maintenance Instructions Model Saf-T Pipe Heavy Duty Black Stove Pipe (Also known as a Connector Pipe) Single Wall Stove Pipe used to connect a Wood Burning Stove to a Listed Factory-Built Chimney System IMPORTANT: A major cause of vent related fires is failure to maintain required clearances (air spaces) to combustible materials. It is of the utmost importance this Saf-T Pipe be installed only in accordance with these instructions. Do not install this product until you have read and fully understand these installation instructions. Failure to install as described in these instructions may result in an injury or property damage, and may have an effect on your homeowner s insurance. An improper installation will void any stated warranty. Keep these instructions in a safe place for future reference. Heavy-Duty Construction - gauge Laser Welded Seams Beaded for Furnace Cement High-Temperature Low-Luster Finish Saf-T Pipe is not a UL Listed Product! WARNING Failure to follow the installation instructions could cause FIRE, CARBON MONOXIDE POISONING, OR DEATH. If you are unsure of installation requirements, call the phone number listed on the instructions,.800.433.634 or visit www.selkirkcorp.com. 5030 Corporate Exchange Blvd Grand Rapids, MI 495 Call 800-433-634 www.heatfab.com

GENERAL Model Saf-T Pipe is a single wall connector pipe which may be used to vent safety certified wood or coal fired appliances with a flue gas temperature not exceeding 000 F. Saf-T Pipe is available in diameters of 5, 6, 7 and 8 and requires a overlap. The installation must conform to applicable National, Regional, State and local building codes and NFPA, the standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances. Contact the Authority Having Jurisdiction prior to beginning any work to obtain any required permits. Follow the appliance manufacturer s installation instructions carefully. SAFETY - Saf-T Pipe must be installed with a minimum of 8 clearance to any combustible surfaces or materials. - Saf-T Pipe must not be enclosed or pass through a floor, ceiling, attic space, roof space, wall, closet, or any concealed space. - To connect into an existing masonry chimney with a combustible wall, use the Listed Saf-T Thimble through-the-wall thimble/ wall pass assembly to reduce the minimum 8 inch clearance to combustibles required by NFPA Standard. (See separate instructions packaged with the Saf-T Thimble). - For mobile home installations follow the installation instructions supplied with the mobile home appliance. IMPORTANT Read all instructions carefully before starting the installation. Failure to install Saf-T Pipe in accordance with these instructions will void the manufacturer s warranty. Serious fire, health, or other safety hazards may result from any of the following: - Installation of any damaged Saf-T Pipe; - Unauthorized modification of any Saf-T Pipe components; - Installation of any component part not manufactured or approved by Selkirk; INSTALLATION GUIDELINES: - Plan the installation of your appliance and Saf-T Pipe in such a way that your connector run is as short and straight as possible. - Having an installation that is too long and / or with multiple bends, can reduce system draft which can affect the operation, and / or performance of your appliance and / or chimney system. Choose the proper diameter of connector pipe. It must be at least equivalent to the stove outlet diameter. - Each Saf-T Pipe component will have a overlap, take this into consideration when planning your installation. - All joints between sections of Saf-T Pipe must be secured with four (4) sheet metal screws per joint before firing (supplied). - Saf-T Pipe must be installed with the smallest diameter in the direction of the appliance, arranged so condensate will drain within the connector pipe and into the appliance (see Fig. ); - Saf-T Pipe must be sloped upward towards the chimney at least /4 inch per foot of horizontal run. AVAILABLE COMPONENTS: A variety of Saf-T Pipe components are available to complete a proper installation. These include: - LENGTHS:, 8, 4, 36 and 48 ; - ADJUSTABLE LENGTHS: to 6 and 38 to 70 ; - ELBOWS: 45, 90 fixed and 90 adjustable; - TEES; - TEE COVER; - CRIMPED TEE PLUG; - INCREASER; - REDUCER; - WALL TRIM COLLAR; - OVALIZED FLUE ADAPTERS FOR VERMONT CASTINGS STOVES FIG. NOTE: Upon installing Saf-T Pipe, the black paint may be touched-up, as required, with Thurmalox #70 black. When properly applied, this product is very effective in blending. Follow the instructions from the paint manufacturer for application. LENGTHS (, 8, 4, 36 and 48 ) : A variety of lengths are available to make the connection from the appliance to the chimney easier without having to cut a pipe length (Fig. ). These can be used vertically or horizontally. The crimped end (smaller diameter) is installed in the direction of the appliance. Smallest Diameter

ADJUSTABLE LENGTHS ( to 6 and 38 to 70 ): An Adjustable Length can be used vertically or horizontally allowing ease of removal for an inspection, maintenance or for cleaning. Even if you have very carefully pre-planned, and pre-measured, very few installations work exactly using the fixed lengths of pipe available. Since the heavy gauge of Sat-T Pipe makes it difficult to cut (it is doable to cut off at the crimped end), we offer two () Adjustable Lengths, an 8 adjustable ( to 6 ) and a 38 to 70 Adjustable Length. Stand the two sections of adjustable pipes next to each other so that the top end of each pipe is the end with the pre-drilled screw holes (see Fig. ). Notice that the top of one pipe has the pre-drilled screw holes below the outward bead. This one will be Pipe #. The other pipe has the pre-drilled screw holes on the expanded portion of the pipe. This one will be Pipe #. See Fig.. Min. to Max. 6 Min. 36 to Max. 70 Pipe # will slip into the top of Pipe #. The end of Pipe # without the pre-drilled screw holes will slide down inside the top of Pipe #. See Fig. 3. When you have found the right installed length for your installation, use the pre-drilled screw holes in the top of Pipe # as a guide and drill through Pipe # using /8 drill bit. Secure the two lengths together by installing the 4 sheet metal screws provided. ELBOWS (45, 90 and 90 Adjustable) : Elbows allow a change in direction in the system or used as an offset when needed. Fixed elbows are available in a 45 or 90 and an adjustable elbow in a 90. The crimped end is installed in the direction of the appliance. See Fig. 4. FIG. FIG.3 CRIMPED TEE : Tees are used for a change in direction in the system and to facilitate the inspection and cleaning of the system. The crimped branch is installed in the direction of the appliance and a Tee Cover is used at the bottom of the Tee. See Fig. 5. FIG.4 FIG.5 OTHER COMPONENTS : Other Saf-T Pipe components are: Increasers and Reducers (even though reducing is not recommended), Wall Trim Collar (when connecting to a masonry chimney) and Oval to Round Adapters (concentric and offset) to connect to Vermont Casting appliances. See Fig. 6. FIG.6 3

COMMON INSTALLATIONS: The next 3 Figures show common installations, Saf-T Pipe connected in a flat ceiling application (Fig. 7), a vaulted ceiling application (Fig. 8) and an installation through an exterior wall (Fig. 9). FLAT CEILING - FIG.7 CATHEDRAL/SLOPED CEILING - FIG.8 EXTERIOR WALL - FIG.9 SAFE OPERATION AND MAINTENANCE : Do not use fuel materials corrosive to Saf-T Pipe such as driftwood, chemically treated wood or garbage or over fire your appliance. This could cause failure of the Saf-T Pipe and void any warranties. When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. Consult your local Extension Service or other authority to learn how to properly burn seasoned wood as a heat source. With a new installation, the system should be inspected frequently (every weeks if need be) to determine the rate of creosote formation. When familiar with the appliance and its venting system characteristics, the system should be inspected at least once every months during the heating season to determine if a creosote or soot build-up has occured. If you see deposits clean all connector pipe and the chimney system mechanically (with a properly sized plastic cleaning brush) to reduce the risk of a chimney fire. Inspect your Saf-T Pipe for any damage before the start of the season. Replace any damaged parts. KEEP YOUR CHIMNEY AND SAF-T PIPE CLEAN! Copyright 06 Selkirk Corp. Heatfab Saf-T Pipe is a registered trademark of Selkirk Corp. PI-SAF-T-PIPE 04//6 4

SMART CHOICE LIMITED LIFETIME WARRANTY Selkirk Corporation, ( Selkirk, we, us, our ) warrants our residential Chimney & Venting products (* defined below) to be free from defects in material and workmanship. For products installed after January, 009, for a period of Ten (0) years from original installation, we will provide replacement product with a similar or like quality of available Selkirk product, free of charge, excluding any installation costs. From the Eleventh () through Fifteenth (5) years, we will provide replacement product at a cost of 75% off the published Retail Price in effect on the date the claim is received, excluding any installation costs. At expiration of the Fifteen (5) year term, we will provide replacement product at a cost of 50% off the published Retail Price in effect on the date the claim is received excluding any installation costs. This warranty coverage is non-transferable and applies exclusively to the original consumer. PROFESSIONAL INSTALLATION: If installation is performed by Professional Installers certified in Canada by WETT or APC or in the USA by NFI or CSIA, we will provide replacement product with a similar or like quality of available product, free of charge (excluding any installation costs) for the full Fifteen (5) years from the date of original installation. To be eligible for this additional warranty the consumer must provide a proof of installation by a Professional Installer when submitting a claim. LIMITATIONS: BUYER S REMEDIES ARE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT AND DO NOT INCLUDE INSTALLATION COSTS. EXCEPT AS SET FORTH HEREIN, ALL OTHER WARRANTIES (EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) ARE HEREBY DISCLAIMED. IT IS AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF THE BUYER. IN NO EVENT SHALL WE BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL OR PUNITIVE DAMAGES ARISING DIRECTLY OR INDIRECTLY FROM THE USE OF THE PRODUCTS WHETHER BASED ON WARRANTY, CONTRACT NEGLIGENCE OR STRICT LIABILITY. ALL LENGTHS, TEES, ELBOWS, AND COMPONENTS SUPPLIED BY US ARE SUBJECT TO WARRANTY COVERAGE. PRODUCT SUPPLIED BY US AS REPLACEMENT FOR ORIGINAL MATERIAL WILL BE SUBJECT TO A ONE-YEAR WARRANTY COVERAGE WITH THE EXCEPTION OF SAF-T PIPE WHICH IS SUBJECTED TO A 5 YEAR LIMITED WARRANTY COVERAGE FROM DEFECTS IN MATERIAL OR WORKMANSHIP WHEN PROPERLY INSTALLED PURSUANT TO THE MANUFACTURER S INSTALLATION INSTRUC- TIONS AND APPROPRIATE CODES. WARNING: FAILURE TO INSTALL OR OPERATE PRODUCTS ACCORDING TO THE MANUFACTURER S INSTRUCTIONS, OR FAIL- URE TO USE PRODUCTS WITH RESIDENTIAL APPLIANCES THAT HAVE BEEN CERTIFIED AT AN ACCREDITED LABORATORY WILL VOID ALL APPLICABLE WARRANTIES. THIS WARRANTY DOES NOT COVER: (a) any non-stainless base tee unit mounted or connected to an Insulated Chimney system; (b) costs (labor or otherwise **) associated with either removing a previously installed product, installing a replacement product, transportation or return of a product, or transportation of replacement product; (c) damage to the finish of products caused by the use of improper solvents/chemicals or improper (or lack of) cleaning methods; (d) damage resulting from normal wear and tear or failure to reasonably clean, care for or maintain products in accordance with our installation instructions/ recommendations; (e) damage (to products, appliances or structure) based on or resulting from improper installation or repair, misuse or abuse (including, but not limited to, excessive or improper operating condition), or alteration or adjustment other than in conformity with our installation instructions and specifications, whether performed by a contractor, service company, technician, or yourself; (f) any products that have been moved from their original installation site; (g) damage caused by burning driftwood, garbage, or any other prohibitive material that has been burned in the appliance served by the chimney; (h) damage that results from accidents such as fire, flood, high winds, acts of God, or any other contingency beyond our control. ** Due to the wide variance in installation practices and other conditions beyond our control, except as stated above, we do not guaranty or in any way warrant the installation of Chimney and Venting products. CLAIM PROCEDURE: If you believe that a product is defective, notify us in writing at: SELKIRK CORPORATION 5030 Corporate Exchange Blvd., Grand Rapids, MI 495 ATTN: WARRANTY CLAIMS.800.433.634 www.selkirkcorp.com SELKIRK CANADA P. O. Box 56, Depot, Hamilton, Ontario, CANADA, L8L 7X6 ATTN: WARRANTY CLAIMS.888.735.5475 www.selkirkcorp.com Notification should include a description of the product, model and serial number (if applicable) and a description of the product defect. Upon receipt of a written claim under this limited warranty and evidence of the date of purchase or installation, at our option and in our sole discretion, we will provide replacement product with similar or like quality of available product excluding any installation costs. We reserve the right to inspect or investigate any warranty claims prior to determining whether to provide replacement product. If, as determined by us, that repair or replacement of the product is not commercially practicable or cannot be completed in a timely manner, we may refund the prorated purchase price paid for the product upon verification by providing a copy of your invoice or receipt of bill of sale. *Selkirk products covered under this warranty: AFCL, ALT, BV (SD, MD, LD), DFS, DSP, DT, DWC/SWC, E, FC (JSC), GT, GTL, PL, QC, R, RF, RV, SAF-T LINER, SAF-T PIPE, SC (JM), SFCL, SPR, ST, U, UPP, UT, UTL, VP, WV. 5