QUALITY CONTROL Passive House Checklist

Similar documents
Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

BEST PRACTICE RECOMMENDATIONS

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Passivhaus. sally godber MEng CEng MIMechE WARM: Low Energy Building Practice. The first 3 in the UK.

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Museum of Bavarian History Regensburg, Germany

Indoor climate systems in passive houses

SUNDRY ASPECTS OF HEAT RECOVERY VENTILATION. In my earlier articles I have described the basics of a Heat Recovery Ventilation system:

Indoor Environmental Quality

CMHC HOME MAINTENANCE CHECKLIST

the STABLES Passive House Certifi cation Pending 3 bedrooms + offi ce / 4th bedroom 3 full bathrooms /- sq ft of living space

The Corbioli House is a single-family house situated

Zehnder Comfosystems. ComfoAir 180 Datasheet

EARTH ADVANTAGE HVAC REQUIREMENTS

Passive House Northwest AIA CEU Provider. Aubrey Gewehr March 27, 2015

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Zehnder ComfoAir flat 150

EXCELSIOR SINHGAD COLLEGE OF ENGINEERING, PUNE PAPER PRESENTATION

Consumer Features & Benefits of Energy Efficient Products

Overview. Case Study 2008 Building America Prototype ICI Showcase House. Daytona Beach, Florida. Project Team: ICI Homes, Building Science Corporation

Are you Getting Your Fan Flows Right?

Equipment Specifications and Required Information Quantity Rebate

Simplified Space-Heating Distribution using Radiators in Super-Insulated Apartment Buildings

Home Maintenance Schedule

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

Address Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances

BUILDER S PRE-INSPECTION CHECKLIST

Clearing the Air: Ventilation. RESNET Building Performance Conference San Diego, CA February 17 th, 2015

MECHANICAL DESIGN. Full service Mechanical Design Professionals that can provide the full package!

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Home Set-up and Maintenance. Maintenance

Certified Passive House Component For cool, temperate climates, valid until 31 December 2017

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

VERSO Air Handling Units

Chifley Passive House: Two years of performance data Harley Truong 1 and Andrew Garvie 2 November 2016

WHY IS BUILDING SCIENCE IMPORTANT?

Building Division WSEC & IRC Ventilation (Effective July 1, 2016) Residential Buildings Prescriptive Compliance Form

Getting in the Zone with Zonal Pressure Diagnostics

HIGH performance exchanger

A highly efficient Enclosure is Key. The Building is always the sum of ALL it s parts

nzeb office building

HeATING. VENTILATION. COOLING. in ONE SYSTEM.

BUILDER S PRE-INSPECTION CHECKLIST

The V in HVAC: Mechanical Ventilation in ENERGY STAR Certified Homes

8 5.11: Finned-Tube Coils and Heat Exchangers : Humidifiers and Water Spray Systems : Access for Inspection, Cleaning, and Maintenance

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

CHAPTER 5: EXHAUST SYSTEMS

research highlight Assessment of Suite Compartmentalization and Depressurization in New High-Rise Residential Buildings

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Effects of Kitchen Ventilation on Residential Dwellings

HVAC Equipment Access Equipment Location

The Art of Building Science

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

Passivhaus. Thompson Road and Carbis Close, Whitleigh, Plymouth. Your handy guide

WHAT S CHANGED WITH ANSI/RESNET/ICC STANDARD 380. Iain Walker, Residential Building Systems Group

707 North Western Avenue, Chicago

Energy Efficient Measures That Add Little or no. Program Lights & Appliances: How To Benefit from the Low-Hanging Fruit

Charter Township of Flushing Construction Permit Fee Schedule.Construction and Development Services Department

VERSO Air Handling Units

Energy Options for Residential Heating. Juergen Korn, P.Eng.

Energy-Efficiency Measures List

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Energy problems in small apartment buildings

Better Buildings By Design What are the best HVAC solutions for low-load, high performance homes? February 6-7, 2013

The Ultimate Home Inspection Checklist

1.1 This section applies to air handling units for HVAC Systems.

Layout. Guidelines11. Chapter 11: Layout Introduction

Put the V back in HVAC

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

101 EASY WAYS TO SAVE ENERGY AND MONEY TOGETHERWESAVE.COM

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

Heat loss via internal drainage vent pipes

SOLAR PASSIVE DESIGN CASE STUDY K & D S HOME

Air Handling Units. T F E.

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Home Performance Science

Low-Impact Remodeling

What Works Lessons in German American Collaboration

Dee Fly Cube 300 and 370. Heat Recovery ventilation

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

REQUIREMENTS FOR HOOD PLANS

Division 11 - Equipment

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

Home Energy Audit. 170 Security Circle Suite 104 Athens, GA

Heat Recovery Units. Heat Recovery 1

ACCA Manual J Load Calculations

COMcheck Software Version Mechanical Compliance Certificate

Ventilation for New Low-Rise Residential Buildings July 20, 2015

FLORIDA HOUSING COALITION 24 th Annual Conference September 27, 2011

WHITE PAPER.

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

2012 International Mechanical Code Significant Changes. About the Significant Changes

ENERGY EFFICIENCY BRIEF REPORT

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

Transcription:

09.01 QUALITY CONTROL - PH Checklist 09.01_PH-SUMMER SCHOOL QUALITY CONTROL Passive House Checklist Composition: Passive House Institut, Darmstadt (DE), Date: 2007-07-03 This presentation is being used for non-commercial purposes. 1

09.01.01 QUALITY CONTROL - PH Checklist 1) Site Plan Proximity to public transportation. South orientation of the "main" side (± 30 ), and large south-facing window areas. Freedom from unwanted shade from building elements, to allow passive solar energy use. Planting that will not cause unwanted shade in the future. Is a compact form possible? Row and multi-story buildings are advantageous. 2

09.01.02.01 QUALITY CONTROL - PH Checklist 2) Concept Development Use a compact building shell, and take advantage of opportunities to combine buildings. Glazed surfaces facing south are optimal; keep east, north and west windows small. Minimize shaded areas (very little or no shade in winter from railings, parapets, building projections, balconies, roof overhangs, divider walls, etc.) Use a simple shell form (if possible, without dormers, returns, etc.) Legend : Quality control measures required. 3

09.01.02.02 QUALITY CONTROL - PH Checklist 2) Concept Development Use a building footprint that concentrates utility installation zones (e.g., bathrooms above or adjacent to kitchens and each other). Leave room for ventilation ducts. Separate basement (if any), airtight and free of heat bridges. Use the PHVP (passive house pre-planning package). Apply for passive house construction subsidies, if available.. Legend : Quality control measures required. 4

09.01.03 QUALITY CONTROL - PH Checklist 3) Building Permit Plans Determine insulation thickness of building envelope. Avoid heat bridges. Determine size of utility room(s). House footprint: short pipe runs (hot and cold water, sewage) und ventilation ducts. Cold air ducts outside; warm air ducts inside the insulated building envelope. 5

09.01.04 QUALITY CONTROL - PH Checklist 4) Detailed Design Drawings Construction standards for extra insulation. (Standard: U < 0.15 W/(m²K) (0.026 Btu/h/ft²/ F); Desired: U < 0.1 W/(m²K) (0.018 Btu/h/ft²/ F)) Heat bridges: Use bridge-free connection details or calculate losses at heat bridges. Airtight connection details. Optimized windows (glazing type, super insulating frames, glass type and coatings, shading) Calculate energy rating using the PHPP (Passive House Development Package). Legend : Quality control measures required. 6

09.01.05.01 QUALITY CONTROL - PH Checklist 5) Detailed Ventilation System Drawings Ductwork: Keep cold air ducts outside, and warm air ducts inside the insulated building envelope, unless they are well insulated and kept very short. Use short runs, smooth inside surfaces and airflow velocities < 3 m/s (9.8 ft/s). Include measurement and adjustment capability, sound attenuation, and fire protection measures. Air vents: Avoid air current short-circuiting, consider air current projection distances and provide adjustability. Do not remove stale air over radiators. Overflow openings: Dimension for Δp <1 Pa (0.0075 Torr) 7

09.01.05..02 QUALITY CONTROL - PH Checklist 5) Detailed Ventilation System Drawings Ventilation: Place central unit and air-to-air heat exchanger near the thermal envelope (good locations are in the envelope, or on the lower floor). Place the air heater inside the insulated envelope, and provide additional insulation of the central unit and air heater as appropriate. Heat recovery rate should be ³ 75%, system should be air tight (leakage < 3%), with electricity efficiency < 0.4 Wh/m³ (0.04 Btu/ft³), and should be adjustable, with a housing that is well insulated acoustically and thermally. 8

09.01.05.03 QUALITY CONTROL - PH Checklist 5) Detailed Ventilation System Drawings Ventilation controls: Provide user-operated settings for "low", "normal" and "high", and consider additional controls in kitchen and baths/toilets. Stove hoods: Use a unit with a high capture rate at low airflow rate and velocity. Unit must include an efficient grease filter. Underground earth-to-air heat exchanger (optional): System should be airtight, with colder parts away from the house, and a bypass (for periods when heating or cooling air to earth temperature is not desired). 9

09.01.06.01 QUALITY CONTROL - PH Checklist 6) Detailed Plumbing and Electrical Drawings Sewage and water lines should be short, and should be well insulated. Insulation must prevent sewer and cold water lines from sweating. Insulate water and heating system valves and other accessories. Use water-saving plumbing fixtures and provide hot water connections for washing machine and dishwasher. 10

09.01.06.02 QUALITY CONTROL - PH Checklist 6) Detailed Plumbing and Electrical Drawings Sewer system should preferably have only one stack, and be properly vented. Vent pipes must be insulated within the building envelope. Assure that electrical and plumbing penetrations of the airtight, insulated building envelope are well insulated and airtight. Use low energy household appliances (list of appliances and their ratings is part of the PHPP) Quality control check of all heating, plumbing and electrical systems. Legend : Quality control measures required. 11

09.01.07 QUALITY CONTROL - PH Checklist 7) Execution, Building Construction Supervision Schedule on-site quality control inspections to check for/assure freedom from heat bridges. Assure that insulation layers are continuous, and without air pockets. Check joint details for air tightness while they are accessible. Have a building shell pressure test performed. When: As soon as the airtight envelope is complete and while it is still accessible; that is, before the interior is finished (coordinate with all trades). How: Blower Door n50-test, including identification of leaks. Legend : Quality control measures required. 12

09.01.08 QUALITY CONTROL - PH Checklist 8) Execution, Ventilation Installation Supervision Assure airtight penetrations. Ducts neatly installed and carefully sealed. Check central unit acoustic insulation (where required), and assure easy accessibility for changing filters. Adjust ventilation in normal service; measure and balance supply and exhaust air volumes; balance supply and exhaust air distribution; and measure the system's electrical power consumption. Legend : Quality control measures required. 13

09.01.09 QUALITY CONTROL - PH Checklist 9) Execution, Plumbing and Electrical Building Installation Supervision Check for airtightness of envelope penetrations. Check for proper insulation of pipes. Legend : Quality control measures required. 14

09.01.10 QUALITY CONTROL - PH Checklist 10) Certification Application for Geprüftes Passivhaus (Tested Passive House) certificate from the PHI. 15