Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Similar documents
PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

Product Data PA13NA PA13PA FEATURES AND BENEFITS

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

697C (60 HZ) Sizes 018 thru 060

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

N4A6. Product Specifications

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

R4H4. Product Specifications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data INDUSTRY LEADING FEATURES / BENEFITS

R4H4. Product Specifications

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. Efficiency. S S Reliability

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Advance Product Data

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Efficiency

2 shp 13 lc 1 36 t - 1 a

Advance Product Data

R 410A Ducted Horizontal Air Conditioner

N4H4. Product Specifications

TECHNICAL SPECIFICATIONS

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Advance Product Data

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

A 14 SEER Heat Pump with R---410A Refrigerant Series

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

WCH5**4. Product Specifications

PRODUCT SPECIFICATIONS

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Whirlpool Split System 13 SEER Air Conditioner W2C3. Features

SPLIT-SYSTEM CONDENSING UNITS. "HRC" Series SEER. Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Product Data. Efficiency

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

Ruud Standard Efficiency Air Handler

AIR HANDLERS AIR HANDLERS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Commercial High-Efficiency Condensing Units

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Installation Instructions

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Ruud Standard Efficiency Air Handler

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Transcription:

AVAILABLE SIZES: 18,000 to 60,000 Btu CERTIFICATION: U.L., c-ul, ARI and CEC Listed ELECTRICAL RANGE: 208 230v, 60 Hertz, 1 Phase COMPRESSOR PROTECTION: Each compressor is protected with internal temperature- and current-sensitive overloads. An internal pressure relief valve provides high-pressure protection to the refrigerant system. FAN MOTOR: A totally enclosed fan motor means greater reliability under rain conditions and dependable performance for many years. Permanentsplit-capacitor-type motors provide more economical operation. COIL DESIGN: The copper tube, enhanced sine wave, aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan for easy removal of water, dirt and leaves. FEATURES Model AA1B SERVICE VALVES: Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. SERVICEABILITY: CABINET: Unit has easy serviceability with one access panel providing access to electrical controls. Removal of top gives access to fan motor, compressor, and condenser coil. Weather-protective cabinet has steel protected with a galvanized coating and treated with a layer of zinc phosphate. A coat of modified polyester powder coating is then applied and baked-on, providing each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a longlasting, rust-resistant, quality appearance. 10.0 SEER AIR CONDITIONER This document was created with FrameMaker 4.0.4 SS-AA1B-02

NOTES: 1. Allow 30 in. clearance to service side of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 F max 125 F. 3. Series designation is the 14th position of the unit model number. 4. Center of gravity. A 3/ 8 IN. DIA TIEDOWN KNOCKOUTS (2) PLACES AIR IN AIR IN AIR DISCHARGE AIR IN AIR DISCHARGE AIR DISCHARGE FIELD POWER SUPPLY CONN 7/ 8 IN. DIA HOLE WITH 1 1 / 8 IN. DIA KNOCKOUT AND 1 3 / 8 IN. DIA KNOCKOUT FIELD CONTROL SUPPLY CONN 7 / 8 IN. DIA HOLE B AIR DISCHARGE AIR IN E M F G H L K J N P D DIA LIQUID LINE CONN 1 1 / 4 2 7 / 8 3 / 8 IN. DIA LIQUID LINE CONN C A93003 UNIT SIZE SERIES DIMENSIONS OPER. WT. A B C D E F J M N P Lb. In. In. In. In. In. In. In. In. In. In. 018 A 112 22-1/2 21-15/16 3-3/16 5/8 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 9-3/4 024 A 121 22-1/2 23-15/16 3-3/16 5/8 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 10-3/4 030 A 127 22-1/2 25-15/16 3-3/16 3/4 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 11-1/4 036 A 142 22-1/2 29-15/16 3-3/16 3/4 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 11-3/4 042 A 169 30 23-15/16 3-1/4 7/8 23-1/2 6-1/2 10 15-1/4 16 11 018 B 103 22-1/2 21-15/16 3-3/16 5/8 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 9-3/4 024 B 115 22-1/2 23-15/16 3-3/16 5/8 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 10-3/4 030 B 125 22-1/2 27-15/16 3-3/16 3/4 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 11-1/2 036 B 152 22-1/2 29-15/16 3-3/16 3/4 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 11-3/4 042 B 175 30 23-15/16 3-1/4 7/8 23-1/2 6-1/2 10 15-1/4 16 11 048 A 177 30 27-15/16 3-1/4 7/8 23-1/2 6-1/2 10 14-1/2 16 16 060 A 215 30 39-15/16 3-1/4 7/8 23-1/2 6-1/2 10 14-1/2 16 17 036 C 125 22-1/2 25-15/16 3-3/16 3/4 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 11-1/4 042 C 133 22-1/2 29-15/16 3-1/4 7/8 18-1/2 4-1/16 8-3/16 12-1/8 12-1/4 11-3/4 048 B 172 30 27-15/16 3-1/4 7/8 23-1/2 6-1/2 10 14-1/2 16 16 060 B 199 30 39-15/16 3-1/4 7/8 23-1/2 6-1/2 10 14-1/2 16 17 The data in this publication is displayed for all series, however, every series may not be available from manufacturer. AN INDEPENDENT LABORATORY UNITARY AIR CONDITIONING SOUND RATING OF OUTDOOR TESTING FOR PUBLIC SAFETY MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI UNITARY EQUIPMENT STANDARD 270 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. 2

METERING DEVICE CHART UNIT SIZE PISTON* IDENTIFICATION NO. 018-A, B 52 024-A, B 59 030-A, B 67 036-A, B, C 73 042-A, B, C 78 048-A 82 048-B 84 060-A 96 060-B 93 * Piston listed is for any approved coil non-capillary tube combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. See notes on page 5. SPECIFICATIONS UNIT SIZE 018 024 030 SERIES A/B A/B A/B ELECTRICAL Unit Volts Hertz Phase 208-230 60 1 Operating Voltage Range* 197 253 Compressor Rated Load Amps 9.6 10.9 15.3 Locked Rotor Amps 49.0 61.0 75.0 Condenser Fan Motor Full Load Amps 0.5 0.5 0.8 Min Unit Ampacity for Wire Sizing 12.5 14.1 19.9 Min Wire Size (60 /75 Copper) AWG** 14/14 14/14 14/14 Max Wire Length (60 /75 ) (Ft) 69/66 54/51 42/40 Max Branch Circuit Fuse Size 15 20 25 COMPRESSOR & REFRIGERANT Compressor Manufacturer Copeland/Tecumseh Type Reciprocating Temperature and Current Protection Internal Line Break Refrigerant Type and Amount R-22 3.88 R-22 4.38 R-22 4.82 Refrigerant Tubes In. OD Vapor and Liquid (up to 50 Ft) 5/8 and 3/8 3/4 and 3/8 CONDENSER COIL & FAN Coil Face Area (Sq Ft) 6.5 7.2 7.9 Fan Motor HP, Type, and RPM 1/12 PSC and 1125 1/10 PSC and 1125 Volts Hertz Phase 208/230 60 1 Condenser Airflow (Cfm) 1900 2100 OPTIONAL EQUIPMENT Short Cycle Protector KSACY0101AAA Start Assist PTC Type KAACS0201PTC Start Assist Capacitor/Relay Type KSAHS0601AAA/KSAHS0301AAA Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Sound Hood N/A Time-Delay Relay KAATD0101TDR Low-Ambient Controller P251-0083 (RCD) Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Crankcase Heater KAACH1001AAA Liquid Line Solenoid Valve KAALS0101LLS Coastal Filter KAACF0401SML TXV Kit (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB TXV (Hard Shut-off) KAATX0901HSO KAATX1001HSO KAATX1101HSO Non-Programmable, F/ C, TSTATPPNAC01 7-Day Programmable, F/ C, TSTATPPPAC01 Thermostat, Manual Changeover, Non-Programmable, F, HH07AT212 Outdoor Sensor TSTATBBSEN01 3

See notes on page 5. SPECIFICATIONS Continued UNIT SIZE 036 042 SERIES A/B C A/B C ELECTRICAL Unit Volts Hertz Phase 208-230 60 1 Operating Voltage Range* 197 253 Compressor Rated Load Amps 16.1 16.7 19.0 20.5 Locked Rotor Amps 82.0 95.0 105.0 115.0 Condenser Fan Motor Full Load Amps 1.4 1.4 1.4 1.4 Min Unit Ampacity for Wire Sizing 21.5 22.3 25.2 27.0 Min Wire Size (60 /75 Copper) AWG** 14/14 14/14 12/12 12/12 Max Wire Length (60 /75 ) (Ft) 39/37 39/37 51/49 51/49 Max Branch Circuit Fuse Size 30 30 40 40 COMPRESSOR & REFRIGERANT Compressor Manufacturer Copeland/Tecumseh Millennium Copeland/Tecumseh Millennium Type Reciprocating Scroll Reciprocating Scroll Temperature and Current Protection Internal Line Break Refrigerant Type and Amount R-22 5.38 R-22 4.32 R-22 5.81 R-22 5.50 Refrigerant Tubes In. OD Vapor and Liquid (up to 50 Ft) 3/4 and 3/8 3/4 and 3/8 7/8 and 3/8 7/8 and 3/8 CONDENSER COIL & FAN Coil Face Area (Sq Ft) 7.9 7.9 9.4 9.4 Fan Motor HP, Type, and RPM 1/4 PSC and 1125 Volts Hertz Phase 208/230 60 1 Condenser Airflow (Cfm) 2600 2500 3300 2500 OPTIONAL EQUIPMENT Short Cycle Protector KSACY0101AAA Standard KSACY0101AAA Standard Start Assist PTC Type KAACS0201PTC KAAC60201PTC KAACS0201PTC KAACS0201PTC Start Assist Capacitor/Relay Type KSAHS0601AAA/ KSAHS0301AAA KSAHS0401AAA KSAHS0701AAA/ KSAHS0301AAA KSAHS0401AAA Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Sound Hood N/A Time-Delay Relay KAATD0101TDR Low-Ambient Controller P251-0083 (RCD) Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Crankcase Heater KAACH1001AAA KAACH1201AAA KAACH1001AAA KAACH1201AAA Liquid Line Solenoid Valve KAALS0101LLS Coastal Filter KAACF0401SML KAACF0501LRG TXV Kit (RPB) KAATX0501RPB KAATX0501RPB TXV (Hard Shut-off) KAATX1201HSO KAATX1201HSO Non-Programmable, F/ C, TSTATPPNAC01 7-Day Programmable, F/ C, TSTATPPPAC01 Thermostat, Manual Changeover, Non-Programmable, F, HH07AT212 Outdoor Sensor TSTATBBSEN01 4

SPECIFICATIONS Continued UNIT SIZE 048 060 SERIES A B A B ELECTRICAL Unit Volts Hertz Phase 208-230 60 1 Operating Voltage Range* 197 253 Compressor Rated Load Amps 26.4 24.4 32.1 28.9 Locked Rotor Amps 129.0 140.0 169.0 165.0 Condenser Fan Motor Full Load Amps 1.4 1.4 1.4 1.4 Min Unit Ampacity for Wire Sizing 34.4 31.9 41.5 37.5 Min Wire Size (60 /75 Copper) AWG** 8/10 8/10 8/8 8/8 Max Wire Length (60 /75 ) (Ft) 100/61 100/61 83/79 83/79 Max Branch Circuit Fuse Size 50 50 60 60 COMPRESSOR & REFRIGERANT Compressor Manufacturer Copeland Millennium Copeland Millennium Type Scroll Temperature and Current Protection Internal Line Break Refrigerant Type and Amount R-22 7.10 R-22 6.38 R-22 7.88 R-22 7.88 Refrigerant Tubes IN. OD Vapor and Liquid (up to 50 Ft) 7/8 and 3/8 7/8 and 3/8 1-1/8 and 3/8 7/8 and 3/8 CONDENSER COIL & FAN Coil Face Area (Sq Ft) 12.8 12.8 19.3 19.9 Fan Motor HP, Type, and RPM 1/4 PSC and 1125 Volts Hertz Phase 208/230 60 1 Condenser Airflow (Cfm) 3300 OPTIONAL EQUIPMENT Short Cycle Protector Standard Start Assist PTC Type KAACS0201PTC Start Assist Capacitor/Relay Type KSAHS0401AAA Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Sound Hood N/A Time-Delay Relay KAATD0101TDR Low-Ambient Controller P251-0083 (RCD) Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Crankcase Heater KAACH1201AAA Liquid Line Solenoid Valve KAALS0101LLS Coastal Filter KAACF0501LRG TXV Kit (RPB) KAATX0601RPB KAATX0601RPB KAATX0701RPB KAATX0701RPB TXV (Hard Shut-off) KAATX1301HSO KAATX1301HSO KAATX1401HSO KAATX1401HSO Non-Programmable, F/ C, TSTATPPNAC01 7-Day Programmable, F/ C, TSTATPPPAC01 Thermostat, Manual Changeover, Non-Programmable, F, HH07AT212 Outdoor Sensor TSTATBBSEN01 N/A Not applicable in this application. * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. ** If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-36. Time-delay fuse. Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. Start assist capacitor and relay required when using liquid solenoid valve or hard shut-off TXV (except 048 and 060 Sizes). Do not use hard shut-off TXV with liquid solenoid valve. NOTE: Control circuit is 24v on all units and requires external power source. All motors/compressors contain internal overload protection. Copper wire must be used from service disconnect to unit. 5

UNIT SIZE-SERIES 018-A,B 024-A,B 030-A,B 036-A,B,C See notes on page 7. INDOOR MODEL RATINGS AND PERFORMANCE TOT. CAP. BTUH FACTORY SUPPLIED ENHANCE- MENT 6 STANDARD RATING FIELD-SUPPLIED ACCESSORY TDR TXV CC5A/CD5A/CD5BA018* 17,400 NONE 10.10 10.30 10.30 CD3(A,B)A018 17,000 NONE 10.00 10.20 10.20 CC5A/CD5A/CD5BA024 17,600 NONE 10.00 10.50 10.50 CC5A/CD5A/CD5BW024 17,600 NONE 10.00 10.50 10.50 CD3(A,B)A024 17,600 NONE 10.00 10.50 10.50 CD3CA024 17,800 NONE 10.00 10.50 10.50 CE3AA024 17,800 NONE 10.00 10.50 10.50 CF5AA024 17,800 NONE 10.00 10.50 10.50 CG5AA024 17,800 TXV 10.00 F(A,B)4ANF018 16,800 TDR 10.00 F(A,B)4ANF024 17,600 TDR 10.50 FC4BNF024 17,600 TDR & TXV 10.50 FC4BNF033 18,000 TDR & TXV 11.00 FD3ANA018 17,100 NONE 10.00 10.20 10.20 FD3ANA024 17,600 NONE 10.00 10.50 10.50 FF1(A,B)NA018 17,200 TDR 10.50 10.50 FF1(A,B)NA024 17,600 TDR 10.50 10.50 FG3AAA024 17,500 NONE 10.00 10.20 10.20 FK4BNF001 17,500 TDR & TXV 12.00 FK4ANF002 17,500 TDR & TXV 12.00 FK4BNF004 17,500 TDR & TXV 12.00 CC5A/CD5A/CD5BA024* 22,200 NONE 10.00 10.30 10.30 CC5A/CDBA/CD5BW024 22,200 NONE 10.00 10.30 10.30 CD3(A,B)A024 22,200 NONE 10.00 10.20 10.20 CC5A/CD5A/CD5BA030 22,600 NONE 10.00 10.20 10.20 CC5A/CD5A/CD5BW030 22,600 NONE 10.00 10.20 10.20 CD3(A,B)A030 22,600 NONE 10.00 10.50 10.50 CD3CA024 22,200 NONE 10.00 10.20 10.20 CD3CA030 22,200 NONE 10.00 10.20 10.20 CE3AA024 22,400 NONE 10.00 10.50 10.50 CE3AA030 22,600 NONE 10.00 10.50 10.50 CF5AA024 22,200 NONE 10.00 10.20 10.20 CG5AA024 22,200 TXV 10.00 10.20 F(A,B)4ANF024 22,200 TDR 10.00 F(A,B)4ANF030 22,400 TDR 10.50 FC4BNF024 22,200 TDR & TXV 10.00 FC4BNF033 22,600 TDR & TXV 10.50 FC4BNF030 22,400 TDR & TXV 10.50 FD3ANA024 21,600 NONE 10.00 10.20 10.20 FD3ANA030 22,400 NONE 10.00 10.50 10.50 FF1(A,B)NA024 22,200 TDR 10.50 FF1(A,B)NA030 22,400 TDR 10.50 FG3AAA024 21,400 NONE 10.00 10.20 10.20 FK4BNF001 23,000 TDR & TXV 11.50 FK4ANF002 23,000 TDR & TXV 11.50 FK4BNF004 23,600 TDR & TXV 11.50 FK4BNF003 23,600 TDR & TXV 11.50 CC5A/CD5A/CD5BA030* 28,200 NONE 10.10 10.20 10.20 CC5A/CD5A/CD5BW030 28,000 NONE 10.00 10.10 10.10 CD3(A,B)A030 28,000 NONE 10.00 10.10 10.10 CC5A/CD5A/CD5BA036 29,000 NONE 10.00 10.10 10.10 CD5A/CD5BW036 29,000 NONE 10.00 10.10 10.10 CD3CA030 27,400 NONE 10.00 10.10 10.10 CD3CA036 28,000 NONE 10.00 10.10 10.10 CD3(A,B)A036 29,000 NONE 10.00 10.50 10.50 CE3AA030 27,800 NONE 10.00 10.50 10.50 CE3AA036 28,600 NONE 10.00 10.50 10.50 CF5AA036 28,800 NONE 10.00 10.10 10.10 CG5AA036 28,800 TXV 10.00 10.10 F(A,B)4ANF030 27,600 TDR 10.00 F(A,B)4ANF036 28,200 TDR 10.20 FC4BNF030 27,600 TDR & TXV 10.00 FC4BNF036 28,200 TDR & TXV 10.20 FC4BNF033 28,600 TDR & TXV 10.50 FD3ANA030 27,800 NONE 10.00 10.20 10.20 FF1(A,B)NA030 28,000 TDR 10.20 10.20 FG3AAA036 28,000 NONE 10.00 10.20 10.20 FK4BNF001 29,000 TDR & TXV 10.50 FK4BNF002 28,200 TDR & TXV 10.50 FK4BNF003 29,000 TDR & TXV 11.00 FK4BNF004 29,000 TDR & TXV 11.00 CC5A/CD5A/CD5BA036* 33,800 NONE 10.00 10.30 10.30 CD5A/CD5BW036 33,800 NONE 10.00 10.30 10.30 CD3(A,B)A036 33,800 NONE 10.00 10.30 10.30 CC5A/CD5A/CD5BA042 33,800 NONE 10.00 10.30 10.30 CD3(A,B)A042 33,800 NONE 10.00 10.30 10.30 CC5A/CD5A/CD5BW042 33,400 NONE 10.00 10.20 10.20 CD3CA036 32,400 NONE 10.00 10.00 CD3CA042 32,400 NONE 10.00 10.00 CE3AA036 33,400 NONE 10.00 10.20 10.20 CE3AA042 33,600 NONE 10.00 10.30 10.30 CF5AA036 33,600 NONE 10.00 10.20 10.20 CG5AA036 33,600 TXV 10.10 10.20 F(A,B)4ANF036 33,200 TDR 10.00 F(A,B)4AN(F,B)042 33,800 TDR 10.20 FC4BNF036 33,000 TDR & TXV 10.00 FC4BNF033 33,400 TDR & TXV 10.20 SOUND RATING (BELS) 7.8 8.0 8.0

UNIT SIZE-SERIES 036-A,B,C 042-A,B,C 048-A,B 060-A,B INDOOR MODEL RATINGS AND PERFORMANCE Continued TOT. CAP. BTUH FACTORY SUPPLIED ENHANCE- MENT STANDARD RATING FIELD-SUPPLIED ACCESSORY TDR TXV FC4BN(F,B)042 33,800 TDR & TXV 10.20 FC4BNF038 35,000 TDR & TXV 10.50 FC4BNB054 35,600 TDR & TXV 10.50 FG3AAA036 33,000 NONE 10.00 10.20 10.20 FK4BNF001 33,000 TDR & TXV 10.50 FK4BNF002 33,000 TDR & TXV 10.50 FK4BNF003 34,000 TDR & TXV 10.50 FK4BNF004 34,400 TDR & TXV 11.00 FK4BNB005 35,000 TDR & TXV 11.00 FK4BNB006 35,000 TDR & TXV 11.00 CC5A/CD5A/CD5BA042* 40,000 NONE 10.00 10.30 10.30 CD3(A,B)A042 40,000 NONE 10.00 10.30 10.30 CC5A/CD5A/CD5BW042 40,000 NONE 10.00 10.30 10.30 CD5A/CD5BA048 40,500 NONE 10.00 10.30 10.30 CD3(A,B)A048 40,500 NONE 10.00 10.30 10.30 CC5A/CD5A/CD5BC048 40,000 NONE 10.00 10.00 CC5A/CD5A/CD5BW048 40,500 NONE 10.00 10.30 10.30 CD3CA042 38,500 NONE 10.00 10.00 CD3CA048 39,000 NONE 10.00 10.00 CE3AA042 40,000 NONE 10.00 10.30 10.30 CE3AA048 40,500 NONE 10.00 10.50 10.50 CF5AA048 40,500 NONE 10.00 10.30 10.30 CG5AA048 40,500 TXV 10.00 10.30 F(A,B)4AN(F,B)042 40,000 TDR 10.00 F(A,B)4AN(F,B)048 41,000 TDR 10.50 FC4BN(F,B)042 40,000 TDR & TXV 10.00 FC4BNF038 40,500 TDR & TXV 10.50 FC4BNB054 41,500 TDR & TXV 10.50 FC4BN(F,B)048 41,000 TDR & TXV 10.30 FG3AAA048 40,000 NONE 10.00 10.20 10.20 FK4BNF003 40,000 TDR & TXV 11.00 FK4ANF005 41,000 TDR & TXV 11.00 FK4BNF006 42,000 TDR & TXV 11.50 CD5A/CD5BA048* 46,000 NONE 10.00 10.40 10.40 CD3(A,B)A048 46,000 NONE 10.00 10.40 10.40 CC5A/CD5A/CD5BC048 45,500 NONE 10.00 10.40 10.40 CC5A/CD5A/CD5BW048 46,000 NONE 10.00 10.40 10.40 CC5A/CD5A/CD5BA060 46,500 NONE 10.20 10.50 10.50 CD3(A,B)A060 46,500 NONE 10.20 10.50 10.50 CC5A/CD5A/CD5BW060 47,500 NONE 10.20 10.50 10.50 CD3CA048 45,000 NONE 10.00 10.20 10.20 CD3CA060 46,000 NONE 10.20 10.50 10.50 CE3AA048 46,500 NONE 10.20 10.50 10.50 CE3AA060 47,500 NONE 10.20 10.50 10.50 CF5AA048 46,500 NONE 10.20 10.50 10.50 CG5AA048 46,500 TXV 10.40 F(A,B)4AN(F,B)048 47,000 TDR 10.40 F(A,B)4AN(F,B)060 47,500 TDR 10.50 FB4ANB070 48,000 TDR 10.50 FC4BN(F,B)048 47,000 TDR & TXV 10.40 FC4BNB070 48,000 TDR & TXV 10.50 FC4BN(F,B)060 47,500 TDR & TXV 10.50 FC4BNB054 47,000 TDR & TXV 10.50 FG3AAA048 45,000 NONE 10.00 10.40 10.40 FG3AAA060 47,000 NONE 10.20 10.50 10.50 FK4ANF006 48,000 TDR & TXV 11.00 CC5A/CD5A/CD5BA060* 56,500 NONE 10.00 10.50 10.50 CD3(A,B)A060 56,500 NONE 10.00 10.50 10.50 CC5A/CD5A/CD5BW060 57,000 NONE 10.20 10.70 10.70 CD3CA060 56,000 NONE 10.00 10.50 10.50 CE3AA060 57,000 NONE 10.20 10.70 10.70 F(A,B)4AN(F,B)060 57,500 TDR 10.50 FB4ANB070 58,000 TDR 10.50 FC4BNB070 58,000 TDR & TXV 10.50 FC4BN(F,B)060 57,500 TDR & TXV 10.50 FC4BNB054 58,000 TDR & TXV 10.50 FG3AAA060 57,000 NONE 10.20 10.50 10.50 FK4ANF006 58,000 TDR & TXV 11.00 SOUND RATING (BELS) * Tested Combination See TDR.90 TABLE. A 90-sec. time delay function can be met by use of external devices, or the time delay feature incorporated into specific furnaces, heaters and thermostats. NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual cfm values obtainable for your system by referring to fan performance data in fan-coil or furnace-coil literature. 4. Minimum outdoor operating ambient in cooling mode is 55 F (12.8 C), maximum 115 F (46.1 C). NOTE: The dashes ( ) appearing in the SEER WITH ACCESSORY TDR column indicate no improvement in efficiency due to time-delay function built into unit as manufactured (see table). 7

METHOD Indoor Fan Time-Delay Relay Furnaces Fan Coils TDR.90 TABLE KAATD0101TDR PART/MODEL NO. 58SX, 58DX, 58SXA, 58SXB, 58DXA, 58DXC, 58SSC, 58DHC, 58WAV, 58ZAV, 58PAV, 58PAP, 58RAP, 58RAV, 58EJA FB4, FB5, FK4, FC4, FA1, FA4 NOTE: In most cases, only 1 of the above should be used to achieve TDR function. More than 1 of the methods listed above in a system may cause degradation in performance. SYSTEM DESIGN 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55 F (12.8 C). 3. Maximum outdoor operating air temperature is 125 F (51.7 C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft. (See items 6 and 7 following.) 6. For interconnecting refrigerant tube lengths greater than 50 ft, consult Long-Line Application Guideline available from equipment distributor. 7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft. 8. Not more than 36 in. of refrigerant tube should be buried in the ground. If necessary to bury tubes under a sidewalk, provide a minimum 6-in. vertical rise to the valve connections at the unit. 9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: SS-AA1B-01 8 1995 CAC / BDP P.O. Box 70, Indianapolis, IN 46206 Catalog No. 92-32AA-1B2 PRINTED IN U.S.A. 2-95