Technical Information Proportional Valve Group Modules PVSK powersolutions.danfoss.com

Similar documents
Proportional Valve Group Modules PVSK

PVSK Module with Integrated Diverter Valve and P-Disconnect Function. Tech Note

Fan Drive HICs Catalog Quick Reference

Vickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97

Service Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97

Service Data Vickers. Piston Pumps. PVH74/81 Variable Displacement Piston Pump - 11 Design M-2207-S. Revised 11/01/97

Series 45 Pumps Fan Drive Control (FDC)

, Temperature Sensor Product Electrical Installation

Installation plan PG 8581 PG 8582 PG en - US

Power Supply Display Module PSDM. Installation and Operation Manual

Installation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr

Installation plan: PG Mat. no Version 00 US

Mud Pump (Emsco Type) Diesel Engine

M/1700; 5/2 & 5/3 Solenoid and pilot actuated spool valves

SUBJECT: NO: Rev. B No Restart/Rough Idle After A Hot Soak GROUP: Vehicle Performance. DATE: Jun. 12, 1998

LFL Series Burner Flame Safeguard Control

Rinnai RH180 Hybrid Tank-Tankless Water Heaters

MODEL X-150D SUB-ASSEMBLY PARTS LIST REV. 02/27/04

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Procedure. for. Installation. of the P/N & P/N Voice Alert Systems. Procedure IP 1 Rev. 1. Date

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2010/52

ENERGYSAVER Direct Vent Wall Furnaces

North American Flame Detector Adapters 8832 through 8839 and Series R

Hoffman Specialty General Catalog

ACC RADIO CONTROL SYSTEM. Rev A 12/23/14

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

bc14g combi oven serial numbers with iw/ix/iz/jg/jo

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Caleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)

ELECTRONIC TEMPERATURE CONTROLLER FOR HYDRONIC HEATING SYSTEMS. SmartComfort LK 100 CT LK 110 LK 120 LK 130

Technical Assignment 3 11/15/04. Executive Summary

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

KIT IOM

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Components only, Unassembled, 4" Metal Control Box. (Order separately) 860T T T T158

Bench Mounted Crimping Tools

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

15B Cast Iron Gas Fired Boilers For Forced Hot Water

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

BA2702-P Linear Actuator

INVITATION TO TENDER ITT PS CONSTRUCTION OF STANLEY PARK MINI TRAIN STATION. AMENDMENT No. 4


SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

CENTRO-MATIC - 278B. Model Controller Series C JAN Section - C8. Form Page. Indicates change

FLAME AMPLIFIER MODULE 3001

55-Gallon Dispenser Package

PRE-INSTALLATION GUIDE

Modular standard power units

55-Gallon Dispenser Package

FLAME DETECTOR ADAPTERS 8832 through 8839 and Series R Bulletin 8832

Prime/Spray Valve Replacement Kit for Hand-Held Sprayers

AIR CURTAINS VCS DESCRIPTION. 2VV s.r.o., Podìbradská 289, PARDUBICE, CZECH REPUBLIC, TEL.: +420/40/ , FAX: +420/40/

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Page 1 of 18. Part# /5/2013

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Stainless steel beer fermenter,wine conical fermenter, fermentation tanks

Better Design, Better Control, Better Systems.

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

2704 Controller Melt Pressure Controller

Installation and Servicing Instructions. Alpha FlowSmart

NuGGeT 200 spool VALVes

Operating Guide Safe Torque Off

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Tri-Stack Smart System

Founder: John C. Cleaver

Turbimax CUE21 / CUE22

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034)

PRE-INSTALLATION GUIDE

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

ENGINEERING SPECIFICATIONS

High Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation

Room thermostat with 24-hour time switch and large LCD

POLY extinguishing systems. The high-performance, unique, and versatile extinguishing system for initial, effective fire fighting.

Installation and Operation Manual AEC9012 Series Programmable Wig-Wag Controller

INSTALLATION & OPERATION MANUAL

CLASSIC. CENTER ISLAND CABINET Installation Instructions

FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

SWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES SENSING BUMPERS INTERFACE CONTROLLERS LIGHT CURTAINS CUSTOM DESIGNS

Fire Control Fire Extinguisher (FC5)

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Suggested Schematics with Control and Power Wiring details

Rotary Screw Compressors R-Series 4-11 kw (5-15 hp) Fixed and Variable Speed Drives

Burner control unit BCU 370

"PV11R" SERIES Fixed Displacement- Single PV11R10/PV11R20

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

LEAP FORWARD WITH GROHFLEX

TUB AND SHOWER TOTAL MAINTENANCE SOLUTIONS TUB FILLERS AND DIVERTER SPOUTS

WOOD FREESTANDING STOVES

Edition 6, From serial no Publ. no Orwak 5030-CE. Operating manual

Transcription:

MAKING MODERN LIVING OSSIBLE echnical Information roportional Valve Group Modules VSK powersolutions.danfoss.com

Revision history able of revisions Date Changed Rev May 2014 Converted to Danfoss layout DIA CMS BC Dec 2010 New back cover BB Jan 2010 Drawings changed BA Jan 2010 Japan location AB Jun 2004 First edition AA 2 520L0556 Rev BC May 2014

Contents Introduction VSK function Dimensions Specifications Specification and code number for VSK modules... 4 Specification and code numbers for VSK spools... 5 VSK characteristics...7 Stay bolt set, VAS for VSK...9 520L0556 Rev BC May 2014 3

Introduction Danfoss introduces VSK-modules with integrated diverter valve and -disconnect function. he module is intended for cranes, telescope lifts and other applications that have special demands on functionality and safety. he VSK-module can be integrated in VG 32 valve groups for open- as well as closed-center systems. VSK VSK spool Functions of the VSK-module: When the diverter valve is in neutral position, there is no pressure (only tank pressure) in the - channel of the valve group. When the diverter valve spool is actuated in A-direction, it enables the basic modules in the VGgroup to receive pump flow supply. When the diverter valve spool is actuated in B-direction, it enables the (High ressure Carry Over) HCO-port in the VSK module and the -cannel in the valve group to receive pump flow supply. Specification and code number for VSK modules Specification and code number for VSK modules Symbol Description Code no. Open and closed center inlet with pilot supply for electrical actuation Max. pump pressure 350 bar [5076 psi] Max. pump flow 120 l/min [31.7 US gal/min] = ¾ ; HCO = ¾ 157B6961 4 520L0556 Rev BC May 2014

Introduction Specification and code numbers for VSK spools Specification and code number for VSK spools Symbol Description Code no. 4 way - 3 position spool for fixed displacement pump HCO flow 40 l/min [10.57 US gal/min] Open neutral position 157B9657 * 4 way - 3 position spool for fixed displacement pump HCO flow 40 l/min [10.57 US gal/min] Closed neutral position 157B9658* * VSK spool must be option mounted. 520L0556 Rev BC May 2014 5

VSK function VSK sectional view HCO HCO VB VB HCO HCO As the VSK-module is provided with pump () and HCO (High ressure Carry Over) connections, the standard pump connection in V, VV or VM must be sealed with a steel plug (see example on page 6). Note that the steel plug is not included upon delivery. In neutral position, the spool in the VSKmodule interrupts the connection from the pump to the -channel in the valve group. his not only ensures a low pressure (tank pressure) in the -channel, but also a low pressure-drop in flow circulating between pump and tank (see VSK characteristics on page 7). As the VSK-module replaces endplate VS/VSI, the code number field (field 11) in the specification sheet must be left open. In general, the diverter function must be specified as a working function VB, which means that VE, VSK spool and VM must be specified separately (see VG 32 specification sheet Specifications on page 10). o ensure an adequate supply to the VE pilot reduction valve, the tank channel of VSK includes a backpressure valve. In open-centre systems, the pump flow must be min. 40 l/min (10.57 US gal/min) to maintain a sufficient pressure-drop across the backpressure valve. V310135.A 6 520L0556 Rev BC May 2014

VSK function As the VSK-module has an integrated pilot oil supply, always use standard V 32 without pilot oil supply in VG 32 valve groups. VSK characteristics ressure drop ; VSK spool in neutral position ressure drop in V 520L0556 Rev BC May 2014 7

Dimensions 85.5[3.366] 23[0.91] [1.46] 48[1.89] L L 2 1 24[0.94] 23[0.91] 16.5[0.650] 12[0.47] 48[1.89] 24[0.94] 95[3.74] 69.5[2.736] 36.5[1.437] 36[1.41] A1 B1 A2 B2 A3 B3 A4 B4 35[1.38] 24[0.89] 62[2.44] 24[0.89] 27.5[1.083] HCO 22[0.87] V310126.A Because of limited space conditions, VE and VM on the work sections have to be mounted as shown on the above drawing. 8 520L0556 Rev BC May 2014

Dimensions Stay bolt set, VAS for VSK Qty, Basic modules L1 L2 Code no. Weight kg [lb] 1 95 165 157B8021 0.25 [0.55] 2 143 213 157B8022 0.30 [0.66] 3 191 262 157B8023 0.35 [0.77] 4 239 311 157B8024 0.45 [0.99] 5 287 360 157B8025 0.50 [1.10] 6 335 409 157B8026 0.55 [1.21] 7 383 458 157B8027 0.65 [1.43] 8 431 507 157B8028 0.70 [1.54] 9 479 551 157B8029 0.75 [1.65] 10 528 600 157B8030 0.85 [1.87] 520L0556 Rev BC May 2014 9

Specifications VG 32 specification sheet 10 520L0556 Rev BC May 2014