HEPA Filtration. HEPA Series. Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Similar documents
KHP Models. KHP Series. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

IAQ VENTILATION SOLUTIONS

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

IAQ VENTILATION SOLUTIONS

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

SHR & VHR Models. SHR & VHR Series. Installation Manual. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

Light commercial models

SER150. Installation Manual. Energy Recovery Ventilators

Light Commercial Heat/Energy Recovery Ventilator

KHP 6000 KHP MODEL FOR LIGHT COMMERCIAL

CVS Model Inline Multi-Port Ventilators

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Ventilation Solutions IAQ Canada

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Ventilation Solutions IAQ Canada

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Heat Recovery Ventilators (HRVs) Flexibility. in Perfect Form. Improving indoor air quality through better ventilation

VHR SERIES VHR 704. Installation Manual. Heat Recovery Ventilator INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Cleanshield HEPA 550 Owner's Manual

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

DBF 4XL Dryer Booster Fans

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

HEALTHY CLIMATE PureAir Air Purification System

DUST FREE CARBON Whole House Air Purifier

Desiccant Dehumidifier

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions

SAFETY AND INSTALLATION MANUAL MODEL 8100

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

Safety and Installation Instructions Model 1700

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Energy Recovery Ventilators

Outside Air Requirements... SOLVED!

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

Model 8120 and 8126 Safety & Installation Instructions

Installation Instructions

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Air Bear Accu-Fit TM. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Installation Instructions

Installation, Operation and Maintenance Instructions

M1200 Series Limited Warranty Dependability Promise

F114 and F115 Ceiling Surface Mounted Media Air Cleaners

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Residential Duct Mount Builder s Box Media Air Cleaner

IMPROPER USE OF THIS HEATER COULD RESULT IN FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Supplement A- Improving Forced Air Heating Systems

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

Owners Manual Model: XXL

USER S INFORMATION MANUAL

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Heat or Energy Recovery Ventilation System

Installation Instructions Preference Wall Mount Range Hood

Owner and Maintenance Guide Models Equipped with K250 Blower

INSTALLATION INSTRUCTION & OWNER S GUIDE

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

Integrated Ventilation System

Bathroom Exhaust Fan

12 Pogo Pole Hose Adapter

Quest Power Electric Heat EHS 31 Pro

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

Clean Air Solutions. A Complete Family of Indoor Air Quality Products, for the Protection of your Home and your Family.

HEAT RECOVERY VENTILATOR

Owner s Manual Phoenix FireBird

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

Air in Motion. Fan Guide Book February 2004 FB-0204

M Series Fan Filter Units

Installation and Operation Manual

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

IMPORTANT SAFETY INFORMATION:

owner s manual Air filtration system 99 % For models : EP1625 / EP2020 / EP2532

2015 MECHANICAL CODE REQUIREMENTS

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

IMPORTANT SAFETY INFORMATION:

PROOF. our story. insert pictures of things or people that tell the story. about your company

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

F25F Media Air Cleaner

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

HEAT STORM PORTABLE QUARTZ INFRARED HEATER USER MANUAL TABLE OF CONTENTS

Model 1750A/ 1770A Dehumidifier Installation Instructions

INSTALLATION INSTRUCTIONS &USE & CARE GUIDE AL-T7200 Versa BBQ Hood Series

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Zoning System Design Manual

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Transcription:

HEPA Series Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected to any other piece of mechanical equipment, i.e. a forced air furnace or air handler, operating at a higher static pressure. CC R US Your Fantech HEPA Filtration system should be installed in conformance with the appropriate local, provincial or state requirements or in the absence of such requirements with the current edition of the National Building Code, and / or ASHRAE s Good Engineering Practices. HEPA Filtration CM 3000 CM 3000 I INSTALLATION, OPERATION AND MAINTENANCE MANUAL

TABLE OF CONTENTS WARRANTY / GARANTIE INSTALLATION Types of installation Installation of CM 3000...4 Installation of CM 3000 I......6 Installation with an HRV/ERV......8 MAINTENANCE... 9 MAINTENANCE REPORT...10 The Best Limited Warranty in the Business The maintenance free motors are permanently lubricated and are guaranteed for 7 years.they are factory balanced to prevent vibrations and promote silent operation. All other components have a 5 year limited warranty. (filters not included) The limited warranty covers normal use. It does not apply to any defects, malfunctions or failures as a result of improper installation, abuse, mishandling or misapplication, fortuitous occurrence or any other circumstances outside manufacturer's control. The warranty is in effect for 5 years on parts and 7 years on the motor after the date of purchase, including parts replaced during this time period. If there is no proof of purchase available, the date associated with the serial number will be used for the beginning of the warranty period. Parts are a 1 year warranty when replaced after the initial warranty has expired. This warranty is the exclusive and only warranty in effect and all other warranties either expressed or implied are invalid. Warranty from the manufacturer is for parts only and does not include labor or shipping to service or repair them. INTRODUCTION HEPA AIR FILTRATION SYSTEMS Congratulations! You have purchased a very effective air cleaning and treatment system incorporating HEPA (High Efficiency Particulate Arrestance) filter technology.this is the type of air cleaning equipment that respiratory specialists recommend most. To optimize the performance of your HEPA Filtration System, it should be installed by a professional contractor who is familiar with your indoor air quality situation and the operation of other heating, ventilation and air conditioning equipment that you may have. TWO UNITS TO CHOOSE FROM The Fantech HEPA Filtration system is available in two different models, depending on your choice of installation.typically the CM 3000 is used in geographical locations where the HEPA unit can be installed in a conditioned space such as a basement, closet or heated crawl space, (Example on page 4 & 5).The CM 3000 I (Insulated version) is normally installed in the southern U.S. states where it's common to locate the HVAC equipment in an unconditioned space such as a garage or attic (Example on pages 6 & 7).

INTRODUCTION SPECIFICATION Model CM 3000 (Uninsulated) * Insulated skin can be purchase seperately and installed in the field if required. Kit (Included): - two pcs. of uninsulated 8 flex (UL Listed) - four 8 round port collars - hanging chains and hardware - installation manual Clearance required for servicing Volts: 115V/1/60 Amps: 1Amps Delivers 240 cfm Airflow SPECIFICATION Model CM 3000 I (Insulated) Unit includes: - two 8 round port collars (attached) - hanging chains and hardware - installation manual Clearance required for servicing Volts: 115V/1/60 Amps: 1Amps Delivers 240 cfm Airflow

OPERATION Your Fantech HEPA filtration system incorporates three stages of filtration. Air is drawn from the house via one of the installation examples, found in this manual, by a powerful efficient EBM fan.the air is cleaned as it passes through the filters, where it is then reintroduced back into the home, cleaned of the majority of harmful particles. Note: A semi-annual service schedule must be followed to ensure the HEPA unit is operating at its full potential. INSTALLATION CM 3000 - Uninsulated model The return side of the furnace is the recommended location for the HEPA to connect to.the supply side is normally avoided due to the higher static pressure. Option A * Furnace fan should operate continuous or when HEPA unit is on and running. (Options A & B) Option B * Diagrams are examples only. Actual installation may vary. 4

INSTALLATION CM 3000 - Uninsulated model (continued) Option C - Duct work can be concealed in walls or closets. If the floor is the only choice, special care should be taken to avoid noise or drafts. Option C Option D - Unit can be installed in a closet. Air drawn from a hallway or living area is cleaned by the HEPA unit and reintroduced back into a bedroom or other room. * Diagrams are examples only. Actual installation may vary. Option D 5

INSTALLATION CM 3000 I - Insulated model In options A & B, the air handler should operate continuously or when HEPA unit is on and operating. Warning - Special care and attention must be given to ensure that all openings in unit, and its duct connections, are sealed, to prevent vehicle exhaust from entering the unit. Always follow local and state building codes as well as good engineering practices. Option A - Garage installation Option B - Attic installation connected to return of air handler * Diagrams are examples only. Actual installation may vary. 6

INSTALLATION CM 3000 I - Insulated model (continued) When unit is installed in an unconditioned space such as option C or option D, ductwork (not included) must be insulated and installed according to local and state codes. Unit should always be installed in a location that will allow the best possible access for service. Flexible ducting can be restrictive to airflow and should be kept to a minimum. Avoid excessive turns, cramped ductwork and pinching. * Proper airflow should be confirmed after installation Option C - Independently ducted 30 max recommended Note: 16.5" of clearance is needed from front of unit to access filter for service. Option D - Independently ducted installation in crawl space Unconditioned crawl space * Diagrams are examples only. Actual installation may vary. 7

INSTALLATION Whole House - Connecting a ventilation system (HRV/ERV) to a HEPA system. Installation may vary drastically from picture depending on location of all appliances. After installation, proper operation of all the appliances must be confirmed by a qualified contractor. Fresh air from outside Ventilation system (HRV/ERV) should be installed and balanced in accordance with its installation manual. Furnace fan must be on when either the ventilation system (HRV/ERV) or the HEPA filtration system is operating. A power damper is recommended to prevent backdrafting of some models of air to air changers, when in the off or standby position.this damper will be installed between the HRV/ERV and the HEPA unit. NOTE: Models SHR/SER 1505R, 2005R & 3005R have an automatic backdraft damper build in that activates when units are in standby position and do not need this additional damper. All units should be checked after installation for compatibility and proper operation. Controls Options A "Accessory Control Contacts" device, which switches the HEPA to its on position anytime the furnace blower is operating, is available through Fantech distributors. * Diagrams are examples only. Actual installation may vary. 8

SERVICE The useful service life of the filter media in the HEPA Filtration System is directly related to the volume of air passed through the system and the amount of contaminants in the air. In a typical residential application, Stage 1 and 2, filters should be replaced every three to six months or when needed.the Stage 3 HEPA filter should have a life span of two to five years, again, depending on the amount of particulate in the air and the maintenance of the Stage 1 pre-filter. PARTS LIST STAGE 1 - PRE-FILTER (470142) STAGE 2 - CARBON FILTER (104654) STAGE 3 - HEPA FILTER (470140) MOTOR - (500002) Stage 1 - Prefilter:Air passes through the prefilter where larger particles are taken out of the air. Stage 2 - Carbon:Air passes through the carbon filter where some gases and odors are removed. Stage 3 - HEPA:Air passes through the certified HEPA media where very small particles are removed. 99.97% of all particles 0.3 microns and larger that pass through this stage are removed. Particles smaller than 0.3 microns are also removed with less intensity. If the air flow through your unit is noticeably reduced, you can inspect the HEPA filter by removing it and seeing if the filter paper is darkened on the inlet or outer side. If it is, the filter cartridge should be replaced. Please contact your local Fantech dealer or call HEPA Customer Service at 1.800.747.1762 regarding replacement of filter media, warranty information or if you have any questions or concerns about the performance of your HEPA Filtration System. 9

MAINTENANCE Schedule Date Type of Service Performed Service Technician 10

11 NOTES

Technical support hotline 1.800.565.3548 United States 1712 Northgate Blvd. Sarasota, FL USA 34234 (T) 1.800.747.1762 (F) 1.800.487.9915 (T) 1.941.309.6000 (F) 1.941.309.6099 Ontario & Western Canada 10-6665 Tomken Road Mississauga, Ontario Canada L5T 2C4 (T) 1.800.407.6195 (F) 1.800.407.8965 (T) 1.905.696.9235 (F) 1.905.696.9236 Québec & Atlantic Provinces 50 Kanalflakt Way Bouctouche, NB, Canada E4S 3M5 (T) 1.800.565.3548 (F) 1.877.747.8116 (T) 1.506.743.9500 (F) 1.506.743.9600 www.fantech.net info@fantech.net Manufactured by: ISO 9001 Article #: 301020 Rev Date:A-0032-J