Single Station Remote Alarm

Similar documents
Protocol Station Remote Alarm

Advantium 16 System Monitor

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

CryoWiz Liquid Nitrogen Cryogenic Switchover

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

ion Genesis Pump Controller

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

SSC-1D installation guide

OmniDry 2.9 Amp Centrifugal Air Mover

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

ALL-WEATHER LANDSCAPE BURIAL SUBWOOFERS Burial Subwoofers: 10 & 12 (250mm & 300mm)

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

FW-RA-LED Remote Multiplex Annunciator Panels

Incutrol/2 Regulator

MBCE-110/230FR Flame Sensor Module

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

INSTALLER S & OWNER S MANUAL

Model NT20e Installation Guide

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

CD6102 / CD6102 OC / CD6102-2

Panel Mounted Heat Exchangers by Dantherm, Inc.

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

TFD-1 Installation & User s Guide

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

MBCE-110/230UV Flame Sensor Module

AG Series Electric Heaters

Intelligent Lighting Controller

FOR EASY, FAST INSTALLATION AND FOR RESULTS

CPL Series Pedestal Convection Heater

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

20 High velocity Air

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Installation & Operation Manual

Figure 1. Figure 2. See notes 1 and 2 below.

INSTALLER S & OWNER S MANUAL

EQUIPMENT Operation Manual

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Thermo-Flo Flow Switches FT10 and GT10 Series Owner s Manual

Automatic Phone-Out Home Monitoring Systems

Beacon 800 Gas Monitor Operator s Manual

Installation, Operation & Service Manual

Air Pump Up to 800 gallons

DRC12FR DRC12FR347. Dynalite. Install Guide

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB

RAM3 Remote Alarm Module

Quest Power Electric Heat EHS 31 Pro

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Installation & Operation Manual

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

ERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)

HotPoly Tote Tank / IBC Heaters (TTH Series)

Owner s Manual Phoenix FireBird

TOUCHDOWN 48 CEILING FAN

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

OPERATING INSTRUCTIONS

SEALING FIBER SEALING COMPOUND

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Quest Power Electric Heat EHS 62 Pro

FLCH4R Garage and Utility Electric Heater

OPERATION, SERVICE & PARTS MANUAL

(HSTAT Series) Instruction Manual

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

6502B RF Distribution

SUTTON 52 CEILING FAN

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

QMF MAINFRAME Installation Manual

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

FUME HOOD MONITOR ALNOR AIRGARD 200

ELSTON 52 CEILING FAN

Comfort Series Instant Hot Water System

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Operating Instructions & Parts Manual Models 99533, 99532

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Retro-DWS Internal Heating Cable System for Non-Pressurized Sewer and Waste Drain Pipes

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Proliphix Thermostat Installation Guide. Release 2.0

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

Lubi Submersible Condensate Removal Pumps

Drink Mixer Operation Manual

OPERATION AND INSTALLATION MANUAL

16" and 20" Economy Incandescent Full Hoods Owner s Manual

Digital Non-Programmable

IW-25-2 Dehumidifier Installation & Operations. Manual

GETZ MANUFACTURING PART # CYLINDER DRYER

Transcription:

ADI 5106C Certified ISO 9001 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation of America 1501 Harpers Road Virginia Beach, VA 23454 To Order Call 1-800-225-0473 or 757-422-8330 Fax 757-422-3125 www.concoa.com May 2003 Supercedes January 2003

THIS PAGE INTENTIONALLY LEFT BLANK -2-

DESCRIPTION OF PRODUCT The Single Station Remote Alarm is capable of operating at either 120VAC or 220VAC depending on which wall mount power supply it was ordered with. It is capable of providing operating status for the left and right banks of one CONCOA Autoswitch/Switchover system. The Single Station Remote Alarm provides power to the Autoswitch/Switchover to operate the status indicator lights and the pressure switches. An Autoswitch product that is configured with the alarm option is equipped with two pressure switch gauges, two sets of status indicators, and a power status indicator. A pressure switch gauge and one set of status indicators are used to monitor and report the state of the pressure for each side of the Autoswitch. A Switchover system has only the pressure switch gauges. The front panel of the Remote Alarm consists of four (4) status indicator lights, an Alarm Silence button, and an audible Alarm. See Figure 1. In addition to the front panel, the left side of the Remote Alarm has a power jack connector where the power supply cable is connected. At the bottom of the Alarm are two (2) connectors where the Autoswtich/Switchover and Output Devices are connected. The Single Station Remote Alarm controls one (1) set of relay contacts that are brought to the Output Connector so they may be used to control an external device. The status indicator lights are organized into paris representing the Left Bank and Right Bank of an Autoswitch/ Switchover System. When a system is operating normally the status indicator light will be green. If the pressure should drop below the preset value of the Autoswitch/Switchover, the audible alarm will sound and the light corresponding to the specific Bank will turn from green to red. When this happens, the output relays will activate. It is sometimes desirable to silence the audible alarm prior to the alarm condition being fixed. Pressing the Silence button will accomplish this. The status indicator lights and the relays will remain activated until the alarm condition is corrected. If the second bank on the same Autoswitch/Switchover generates an alarm while the first Bank is still in an alarm condition the other status indicator light in that system will turn from green to red and the audible alarm that was previously silenced will sound again. Correcting the low pressure condition will return the status lights back to green, and deactivate the relay. Audible Alarm Silence Red Alarm Indicators Green Normal Indicators Power Jack Audible Alarm Figure 1-3- Autoswitch/Switchover connector Relay Contact Output

INTENDED USE OF PRODUCT The Single Station Remote Alarm is used to monitor and report the status of inlet pressure on Switchover Systems and Autoswitch Systems. The Alarm can be configured to operate with either normally open or normally closed pressure switch contacts. The Alarm contains a set of relay contacts that can be used to control any device that can be activated using a normally open or normally closed switch. One example of such a device would be the CONCOA telephone dialer (PN 5295306). Connections to the Alarm are made through input and output connectors. Customer supplied cables are easily soldered to the connectors prior to plugging the connectors into the Alarm. For connector pin assignments please refer to the CONNECTING THE ALARM section of this manual. USER RESPONSIBILITY Service to this product should only be performed by CONCOA or an authorized CONCOA agent. Requests for service may be made through CONCOA CUSTOMER SERVICE at 1-800-225-0473. Written requests may be made using CONCOA s FAX number at 1-757-422-3125 or CONCOA s E-MAIL at e-mail@concoa.com. CONCOA accepts no responsibility for damage or injury if this product is modified in any way. CONCOA assumes/accepts no liability or responsibility for damage to individuals or equipment that may occur when using this product. GENERAL SAFETY PRACTICES Basic safety precautions must be followed to reduce the risk of fire, electrical shock or injury. a. Connect the Alarm to the correct line voltage. The product is supplied with either a 120 VAC or 220VAC wall mount power supply. b. While the Alarm is dust and moisture resistant, it should be installed in a location where it will not be subjected to rain or high concentrations of dust. Never pour or spray liquids directly onto the product. c. Install the Alarm where the ambient temperature range while operating is between 0 F and 140 F. d. Do not install the product in hazardous locations. e. If product appears damaged in any way, do not use and request service from CONCOA. f. Do not attempt to operate the Alarm with the cover off. CONNECTING THE ALARM To connect the Single Station Remote Alarm to a Switchover or Autoswitch system, an interface cable must be made. The Autoswitch/Switchover systems are shipped with a connector that is used for this cable. Two connectors are provided with the alarm. One is used to connect to the Autoswitch/Switchover and the other is to connect to the output relay contacts. To perform the assembly task you will need a soldering station or pencil, rosin core solder, and a wire stripper. It would also be helpful to have a vise to hold a connector while soldering the wires to it. OPTION 1: For Switchover Systems that have a 4 pin circular connector. It will be necessary to obtain a 4 conductor cable. The length of the cable is determined by the application but should be limited to no longer than 1500 feet. It is recommended that 22 AWG stranded wire be used. (Alpha #5004C or Belden #8444 are acceptable types.) -4-

OPTION 1 (continued) Cut the 4 conductor cable to length. Remove the outer jacket of the cable to expose approximately 11 2 inches of the internal conductors. Strip away 1 4 inch of the insulation on each of the 4 conductors. Tin the leads of the conductors. Slide the protective cover, cable retainer, and locking nut for the circular connector over one end of the cable as shown in Figure 2. Cable Retainer Tabs Cable Cover Cable Retainer Locking Nut Plug Figure 2 notch notch Figure 3 Figure 4 Table 1 SYSTEM LEFT BANK RIGHT BANK Switchover Connector Pin # Remote Alarm Connector Pin # Function 2 1 LBSW status --- --- alarm 3 4 RBSW status --- --- alarm 1 3 +12 4 6 Gnd Using the pin assignments shown in Table 1 and the connector views in Figure 3 and Figure 4, solder the wires to the appropriate pins. After soldering is complete attach the cable cover, cable retainer, and locking nut to each of the circular connector plugs. Plug the Input Connector side of the cable (6 pin connector) into the Remote Alarm and secure it by turning the locking nut until it locks. Plug the 4 pin circular connector into the Switchover securing it by turning the locking nut until it locks. OPTION 2: For Autoswitch Systems that have a 6 pin circular connector. It will be necessary to obtain a 6 conductor cable. The length of the cable is etermined by the application, but should be limited to no longer than 1500 feet. It is recommended that 22 AWG stranded wire be used. (Alpha #5006C or Belden #8446 are acceptable types.) -5-

OPTION 2 (continued) Cut the 6 conductor cable to length. Remove the outer jacket of the cable to expose approximately 11 2 inches of the internal conductors. Strip away 1 4 inch of the insulation on each of the 6 conductors. Tin the leads of the conductors. Slide the protective cover, cable retainer, and locking nut for the circular connector over one end of the cable as shown in Figure 5. Cable Retainer Tabs Cable Cover Cable Retainer Locking Nut Plug Figure 5 SYSTEM LEFT BANK RIGHT BANK AutoSwitch Connector Pin # Table 2 Remote Alarm Connector Pin # Function 1 1 LBSW status 2 2 alarm 4 4 RBSW status 5 5 alarm 3 3 +12 6 6 Gnd notch Figure 6 Using the pin assignments shown in Table 2 and the connector view in Figure 6, solder the wires to the appropriate pins. After soldering is complete attache the cable cover, cable retainer, and locking nut to each of the circular connector plugs. Plug the one side of the cable into the Remote Alarm and secure it by turning the locking nut until it locks. Plug the other circular connector into the Autoswith securing it by turning the locking nut until it locks. -6-

CONNECTING THE OUTPUT The Single Station Remote Alarm activates a set of relay contacts in response to an alarm condition. This set of relay contacts can be connected to any external device that is activated by the opening or closing of a switch. Examples would be CONCOA s telephone dialer, a Warning Light, an external buzzer, or another monitoring or alarm system. Whatever the connecting device, care must be taken not exceed the rating of the relay contacts (Table 3). Refer to Table 4 for the pin assignments for the Output Connector. Table 3 Relay Contact Rating 24 VDC 1 amp Resistive Load 115 VAC 0.5 amp Resistive Load Cable Retainer Tabs Cable Cover Cable Retainer Locking Nut Plug Figure 7 Table 4 Pin Number Function Contact 1 Common (C) 2 Relay Output Normally Closed (N.C.) 3 Normally Open (N.O.) 4 Unused notch Figure 8-7-

CONFIGURING THE REMOTE ALARM The Single Station Remote Alarm can be configured to allow connection to either Normally Open (N.O.) or Normally Closed (N.C.) pressure switches. Setting the Alarm for Normally Open or Normally Closed Pressure Switches The Single Station Remote Alarm is factory set to operate with Normally Closed (N.C.) pressure switches. To configure the alarm to operate with Normally Open (N.O.) pressure switches perform the following steps: 1. Unplug the power plug from the Remote Alarm power jack. 2. It is best to set the unit on a flat surface face down. Remove the four (4) screws that hold the back cover on and set the cover aside. 3. Locate the 4 position DIP switch array and then using a stylus or small screwdriver open and close the DIP switches according to Table 9A, 9B and Figure 9. 5. Place the back cover back onto the base and tighten the screws. 6. Reconnect the power plug into the power jack and plug the unit in. Table 9A Settings for Normally Open (N.O.) Operation DIP Switch Factory Default Settings 1 Open 2 Close 3 Close 4 Close 5 Open 6 Close 7 Close 8 Close *OFF = Open, ON = Closed Figure 9 Table 9B Settings for Normally Closed (N.C.) Operation DIP Switch Factory Default Settings 1 Close 2 Open 3 Open 4 Open 5 Close 6 Open 7 Open 8 Open *OFF = Open, ON = Closed -8-

TROUBLESHOOTING Symptom Unit is plugged in but no lights are lighting on the Alarm Unit is plugged in, red alarm light(s) are ON but the gauge(s) on the Autoswitch/Switchover is above the alarm pressure. Audible Alarm begins to sound as soon as power is turned ON. Output does not appear to be functioning. Cause 1. Check to see that there is power at the source. 2. Check that cable to Autoswitch/Switchover is plugged in. 3. If the Alarm has been re-configured from the factory settings, check that the DIP switches were properly set. Refer to "Configuring the Remote Alarm" section of the manual. 1. Check to see that the cable running between the alarm and the Autoswitch/Switchover is properly wired. 1. Check that the Autoswitch/Switchover Connector is plugged in properly. 2. Check that the cable between the Autoswitch and Alarm is not cut or pinched somewhere. 3. Check to see that all the wires in the cable are properly soldered to the connectors. 1. Check the cable to the output device to be sure it is properly connected. 2. Check the Output Connector to be sure it is properly plugged into the Alarm. 3. Check the external output device to make sure it is functioning properly. SERVICE Service by a factory authorized facility should be done if an Alarm becomes inoperative and troubleshooting has not isolated the problem. Contact CONCOA Customer Service at 1-800-225-0473 for assistance. If advised to return the unit for service you should: 1. Package the Alarm to prevent damage in shipping. If possible, use the original shipping materials. 2. Ship the unit back pre-paid. 3. Make sure the RMA number appears on the packaging and inside the package. 4. Include an explanation of the problem you encountered. -9-

MOUNTING DETAIL Velcro Mounting Strips Figure 10 ELECTRICAL SPECIFICATIONS Protocol Station Remote Alarm: 120 Volt Version 120 Volts ±10%, 50-60 hz., 6VA 220 Volt Version 220 Volts ±10%, 50-60 hz., 6VA Fuses: Internal - Resettable Polyfuse -10-

Warranty Information This equipment is sold by CONTROLS CORPORATION OF AMERICA under the warranties set forth in the following paragraphs. Such warranties are extended only with respect to the purchase of this equipment directly from CONTROLS CORPORATION OF AMERICA or its Authorized Distributors as new merchandise and are extended to the first Buyer thereof other than for the purpose of resale. For a period of one (1) year from the date of original delivery (90 days in corrosive service) to Buyer or to Buyer s order, this equipment is warrantied to be free from functional defects in materials and workmanship and to conform to the description of this equipment contained in this manual and any accompanying labels and/or inserts, provided that the same is properly operated under conditions of normal use and that regular periodic maintenance and service is performed or replacements made in accordance with the instructions provided. The foregoing warranties shall not apply if the equipment has been repaired: other than by CONTROLS CORPORATION OF AMERICA or a designated service facility or in accordance with written instructions provided by CONTROLS CORPORATION OF AMERICA, or altered by anyone other than CONTROLS CORPORATION OF AMERICA, or if the equipment has been subject to abuse, misuse, negligence or accident. CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s sole and exclusive remedy under the above warranties is limited to repairing or replacing, free of charge, at CONTROLS COR- PORATION OF AMERICA s option, the equipment or part, which is reported to its Authorized Distributor from whom purchased, and which if so advised, is returned with a statement of the observed deficiency, and proof of purchase of equipment or part not later than seven (7) days after the expiration date of the applicable warranty, to the nearest designated service facility during normal business hours, transportation charges prepaid, and which upon examination, is found not to comply with the above warranties. Return trip transportation charges for the equipment or part shall be paid by Buyer. CONTROLS CORPORATION OF AMERICA SHALL NOT BE OTHERWISE LIABLE FOR ANY DAMAGES INCLUDING BUT NOT LIMITED TO: INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, OR SPECIAL DAMAGES, WHETHER SUCH DAMAGES RESULT FROM NEGLI- GENCE, BREACH OF WARRANTY OR OTHERWISE. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE WAR- RANTIES HEREINABOVE SET FORTH. CONTROLS CORPORATION OF AMERICA MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE EQUIPMENT OR PARTS THEREOF. -11-

ADI 5106C Certified ISO 9001 Product Serial Number: PACKING LIST Qty Part Number Description 1.... 5295106-01-120... 120 VAC SINGLE STATION REMOTE ALARM 1.... 5295106-01-220... 220 VAC SINGLE STATION REMOTE ALARM INCLUDES: 1.... 5295106......... SINGLE STATION REMOTE ALARM 1.... 8309210-3........ POWER SUPPLY, 120 VAC 1.... 8309210-2........ POWER SUPPLY, 220 VAC 1.... 8309170-22....... CONN, 4 PIN SOC FEMALE (OUTPUT) 1.... 8309170-17....... CONN, 6 PIN SOC FEMALE (INPUT) 1.... 99065106........ INSTRUCTION MANUAL, REMOTE ALARM Controls Corporation of America 1501 Harpers Road Virginia Beach, VA 23454 To Order Call 1-800-225-0473 or 757-422-8330 Fax 757-422-3125 www.concoa.com