BUILDING VENTILATION GUIDE

Similar documents
BUILDING VENTILATION GUIDE FOR LG HVAC SYSTEM INSTALLATION

Safety, Installation, and Operation Manual

IAQ: Re-tuning Commercial Buildings

Designing Energy Efficient Outdoor Air Systems

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

Florida Department of Transportation

INDOOR UNIT PRODUCT OVERVIEW

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

TR Series - The Ultimate ERV

Mold/Moisture Control Case Study

b.) Technical Information:

Installation Instructions

Adding More Fan Power Can Be a Good Thing

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

8 5.11: Finned-Tube Coils and Heat Exchangers : Humidifiers and Water Spray Systems : Access for Inspection, Cleaning, and Maintenance

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

Union County Vocational - Technical Schools Scotch Plains, New Jersey

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Single zone Art Cool Premier

ASHRAE JOURNAL ON REHEAT

APC APPLICATION NOTE #109

7. MECHANICAL SYSTEM DESIGN

74 Humidity 66 % MultiSITE CRC1 Series Controllers INSTALLATION MANUAL. PREMTBVC0 MultiSITE CRC1 PREMTBVC1 MultiSITE CRC1+ Occ Auto Heat.

Desiccant Dehumidifier

Land Use and Environmental Service Agency (Code Enforcement) NC Mechanical Code. Table of Contents

The ultimate fresh air solution.


Installation and Operation Manual

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

LG Ventilation Kit INSTALLATION MANUAL. Model: PTVK410 / PTVK420. website

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Safety and Installation Instructions Model 1700

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Art Cool Premier Wall Mounted. Engineering Manual. 3/4 and 1 Ton

Digital Precise Air Control - DPAC

Air Distribution Fan and Outside Air Damper Recycling Control

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

CHAPTER 4. HVAC DELIVERY SYSTEMS

LG VRF Systems. Air Conditioning Technologies

Installation Instructions

Heat Recovery Ventilation

Submittal Data Performance Data Electrical Data

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Ceiling Mount Air Purification System

HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074)

Single zone extended pipe WALL MOUNTed

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

USEFUL RESOURCES: Applicability. Item o of section 150. Review-Definitions Section 101

Benefits Offered by Passive Dehumidification Wheel Speed Control

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

USER S INFORMATION MANUAL

High-Performance VAV Systems

Installation Instructions Remote Blowers

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

GARCIA GALUSKA DESOUSA Consulting Engineers

DADANCO Technical Paper

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

Dehumidifying with Dedicated Outdoor Air

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

AirCycler g2-k Installation & User s Guide

17 Interior Climate Control

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

2 Finding Information

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

ML180UH SERIES GAS FURNACE WARNING WARNING

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Residential Duct Mount Builder s Box Media Air Cleaner

Don t Turn Active Beams Into Expensive Diffusers

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

SECTION AIR OUTLETS AND INLETS

LEED for Homes Points

Do All DOAS Configurations Provide the Same Benefits?

PDH & Professional Training

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

EXHAUST FAN SCHEDULE

Model 8120 and 8126 Safety & Installation Instructions

SIngle zone Mega and Mega 115V Wall Mounted Owner s Manual

Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Residential Compliance June 2014

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

FEATURES AND BENEFITS

Engineering Manual. Art Cool Premier Wall Mounted 3/4 and 1 Ton

10-year industry best core warranty. 5-year warranty on balance of unit.

SECTION DUCTWORK

Ventilation for New Low-Rise Residential Buildings July 20, 2015

CHAPTER 7 ALTERATIONS LEVEL

TRIAD Boiler Systems, Inc Atlantic Drive, Unit 2 West Chicago, IL

Instruction Manual Item No.: V~, 60Hz

Transcription:

BUILDING VENTILATION GUIDE

PROPRIETARY DATA NOTICE This document, as well as all reports, illustrations, data, information, and other materials are the property of LG Electronics U.S.A., Inc., and are disclosed by LG Electronics U.S.A., Inc., only in confidence. This document is for design purposes only. Do not throw away, destroy, or lose this manual. Please read carefully and store in a safe place for future reference. Content familiarity is required for proper installation. The instructions included in this manual must be followed to prevent product malfunction, property damage, injury, or death to the user or other people. Incorrect operation due to ignoring any instructions will cause harm or damage. The level of seriousness is classified by the symbols described by the summary list of safety precautions below. TABLE OF SYMBOLS DANGER WARNING This symbol indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This symbol indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION This symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. This symbol indicates situations that may result in equipment or property damage accidents only. This symbol indicates an action that should not be performed. For more technical materials such as submittals, catalogs, engineering, owner s, best practices, and service manuals, visit www.lghvac.com. For continual product development, LG Electronics U.S.A., Inc. reserves the right to change specifications without notice. LG Electronics U.S.A., Inc.

INTRO, METHOD 1 Introduction ASHRAE Standards 62.1 and 62.2 (depending on if the building is residential or commercial), and local codes specify the minimum volume of airflow that must be provided to an occupied space. Outdoor air is required to minimize adverse health effects, and it provides acceptable indoor air quality for building occupants. Indoor units located within the zone typically require less airflow to condition the space. During the design phase, refer to the airflow capabilities listed in the specification tables for each product. Choose the best method for the application out of the five (5) ventilation options available summarized here. Disclaimer Although we believe that these building ventilation methods have been portrayed accurately, none of the methods have been tested, verified, or evaluated by LG Electronics, U.S.A., Inc., In all cases, the designer, installer, and contractor should understand if the suggested method is used, it is used at their own risk. LG Electronics U.S.A., Inc., takes no responsibility and offers no warranty, expressed or implied, or statutory and the implied warranties of merchantability and fitness for a particular purpose are excluded should the building ventilation methods fail to perform as stated or intended. For a complete copy of Standard 62.1 and 62.2, refer to the American Standard of Heating and Air Conditioning Engineers (ASHRAE) website at www.ashrae.org. For more information on how to properly size a ventilation air pretreatment system, refer to the article, "Selecting DOAS Equipment with Reserve Capacity" by John Murphy, published in the ASHRAE Journal, April 2010. Method 1: Decoupled Dedicated Outdoor Air System (DDOAS) Provide a separate, dedicated outdoor-air system designed to filter, condition, and dehumidify ventilation air and deliver it directly to the conditioned space through a separate register or grille. This approach requires a separate independent ventilation duct system not associated with the Multi V VRF system. LG recommends using the DDOAS method in all installations. May be used with a full lineup of the indoor units. The outdoor air unit may supply neutral air to the occupant space even when the Multi V indoor unit fan changes speed or cycles on and off. DDOAS controls do not have to be interlocked with the Multi V system. In lieu of installing localized smaller outside air treatment equipment throughout the building, this method centralizes the ventilation air source making service and filter changes easier. Third-party demand control ventilation controls are more readily accommodated. Ceiling space is required to accommodate ductwork between the centralized outdoor air unit and ceiling diffusers. Ceiling Diffuser Multi V Ceiling-Cassette Indoor Unit Outdoor Air Outdoor Air Unit / ERV 3

METHOD 2 Method 2: Unconditioned Outdoor Air (Non-Ducted, Natural Ventilation) Natural ventilation devices, such as operable windows or louvers, may be used to ventilate the building when local code permits. The open area of a window or the free area of a louver must meet the minimum percentage of the net occupied floor area. Occupants control the volume of the ventilation air manually. Useful for historic buildings that have no ceiling space available for outdoor air ductwork. May be used with the full lineup of Multi V indoor units. In some locations, it may be difficult to control humidity levels when windows are open. Thermal comfort levels may be substandard when windows are open. Indoor units may have to be oversized to account for the added heating and cooling loads when windows are open. Provides outdoor air to perimeter spaces only. Additional mechanical ventilation system may be required to satisfy requirements for interior spaces. Outdoor air loads may be difficult to calculate since the quantity of outdoor air is not regulated. May affect indoor unit proper operation when open. 4

METHOD 3 Method 3: Unconditioned Outdoor Air Ducted to Indoor Units Untreated outdoor air is channeled through a duct system that is piped to the return air duct on Multi V ducted indoor units or to the frame of Multi V one-way and four-way cassettes. Outside air may flow backward through the return air-filter grille when the indoor unit fan speed slows or stops in response to changes in the space load. This may result in captured particulate on the filter media being blown back into the conditioned space. May require less ductwork if indoor units are placed near outdoor walls or a roof deck. Controls must be interlocked to shut off the outdoor air supply fan when the space is unoccupied. Third-party demand-control ventilation controls may be installed to regulate outdoor intake based on the CO 2 levels of the occupied space. Fan(s) will be required to push outdoor air to the indoor unit. Indoor units are engineered for low sound levels and are not designed to overcome the added static pressure caused by the outdoor air source ductwork. Ventilation air must be pre-filtered before mixing with the return air stream. LG indoor cassette models are configured to introduce the ventilation air downstream of the return air filter media. Ducted, one-way, and four-way cassette models are the only indoor units that accept the connection of an outdoor air duct to the unit case. Mixed air conditions must be between a minimum of 59 F DB while operating in heating and a maximum of 76 F WB while operating in cooling. Depending on the ventilation air volume requirement, the location choices are limited where untreated outside air may be introduced to the building using this method. Larger indoor units may be required to satisfy for additional outdoor air. Motorized dampers may be required to prevent outdoor air flow through the indoor unit when the indoor unit is not operating. An LG Dry Contact adapter may be necessary to interlock the motorized damper with the indoor unit. While operating in heating, the untreated outdoor air may delay the start of the indoor unit fan impacting building comfort. In most cases, in lieu of using the factory mounted return-air thermistor on indoor units, a remote wall temperature sensor or zone controller will be needed for each indoor unit to provide an accurate reading of the conditioned area temperature. OA Wall Cap Damper Inline Fan with Filter 5

METHOD 4 Method 4: Unconditioned Outdoor Air (Non-Ducted, Fan Assisted Ventilation) When approved by local codes, the fan assisted ventilation method uses exhaust fans to remove air from the building, and outdoor air is drawn into occupied spaces through a wall louver or gravity roof intake hood. Supply fans can also be used to push the outdoor air into the space and building positive pressure will vent the exhaust air through louvers or roof-mounted exhaust hoods. Outdoor air is neither cooled nor heated before entering the building. This may result in loss of building pressurization control, increasing infiltration loads with adverse effects. Outdoor air may be manually controlled by the occupant or automatic controls may be installed to open/close outdoor air dampers or to turn on/off ventilation fans. Useful for large open spaces like warehouses, garages, and workshops. Outdoor air volume is a known quantity. Air loads may be easier to calculate since fans will regulate the amount of outdoor air. May be used with a full lineup of Multi V indoor units. In some locations of the country, it may be difficult to control humidity levels while outdoor air louvers/hoods are opened. Thermal comfort levels may be substandard when louvers/hoods are opened. Indoor units may have to be oversized to account for the added heating/cooling loads when louvers/hoods are open. Hot, cold, and/or humid areas may be present if the outdoor air is not evenly distributed to the different spaces. Roof Fan OA Wall Louver Damper 6

METHOD 5 Method 5: Coupled Dedicated Outdoor Air (CDOA) A separate, dedicated outdoor air system delivers air directly to a Multi V indoor unit or to the return air duct system. After mixing with the return air stream, ventilation air passes through the indoor unit and into the conditioned space. The pretreatment system is capable of filtering, conditioning, and dehumidifying outdoor air to room neutral conditions. Outside air may flow backward through the return air-filter grille when the indoor unit fan speed is reduced or stops when the space load is satisfied. This may result in captured particulate on the filter media being blown back into the conditioned space. Separate ceiling registers or grilles for introduction of the outside air to the conditioned space may be avoided. Ducted, one-way, and four-way cassette indoor units are the only models designed for direct connection of an outside air duct. The building occupant may not notice the outdoor air pretreatment system has malfunctioned until the unconditioned outdoor air exceeds the indoor unit mixed air limits of 59 F DB for heating and 76 F WB for cooling. If the coil entering air condition limitation is exceeded, the indoor unit may malfunction and cease to operate. If the outdoor air unit cooling or heating system fails, the malfunction may be masked by the indoor unit ramping up operating parameters to compensate for the failure. Motorized dampers may be required to prevent outdoor air from entering the indoor unit while the indoor unit has cycled off. An LG Dry Contact adapter is necessary to interlock the motorized damper with the indoor unit fan operation. In lieu of using the factory mounted return-air thermistor, a remote wall temperature sensor or zone controller may be required to provide an accurate conditioned space temperature reading. Outdoor Air Unit 7

LG Electronics Commercial Products Support 1-888-865-3026 USA Follow the prompts for commercial A/C products. LG Electronics, U.S.A., Inc. Commercial Air Conditioning Division 4300 North Point Parkway Alpharetta, Georgia 30022 www.lghvac.com New Issue: EM_ MultiV_BuildingVentilationGuide _01_17