DPR MM DIGITAL STRIP CHART RECORDER

Similar documents
DPR MM DIGITAL STRIP CHART RECORDER

STT 3000 Series STT250 /150 Surge Protection Device Specifications

DPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS

MVX 2000 Multivariable Pressure Transducer. Specifications 34-SM March Introduction. Proven Sensor Technology. Flow Computer Benefits

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

OneWireless Gauge Reader WGR400 Series Specifications 34-XY July 2009

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

UDC100 Universal Digital Controller Specifications

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Nov 08 PRODUCT SPECIFICATION SHEET

E + M III. Suitable for interfaces. up to CATEGORY 4 per EN E197638

DCP200 Digital Controller Programmer Specification

UDC 700 Universal Digital Controllers and Indicator Specifications

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

DCP200 Digital Controller Programmer Specification

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

CD3000S-2PH. up to 100A

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

04973 Series Conductivity Cells Installation and Maintenance Manual

Beckhoff short profile

Accuracy counts! Sensors with analog output

4905 Style Conductivity Cells Installation and Maintenance Manual

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

OneWireless Gauge Reader Application Gateway User's Manual

FF-SG Series. Safety light curtain Compact and low-cost unit

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Specification , July 2015

Installation Instructions

Controllers, Indicators & Set Point Programmers

Muting function The muting sensors must be able to recognise the passing material (pallets, vehicles, etc.) according to the material's length and spe

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

I/A Series 716C 1/16 DIN Temperature Controller

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Process & TeMPerATUre UniversAl input DigiTAl MeTers

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Toroidal Conductivity Transmitters Series APT4000 Specifications

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

Advanced Test Equipment Rentals ATEC (2832)

MICROJET RECORDER (24-CHANNEL 180mm)

Temperature Controllers

Figure 1 DirectLine DL423 Sensor. Description, continued

MEAS CAL ALARM WASH CONF APT4000 TC

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

Model 1062 Environment Monitor

MICROJET RECORDER (180mm)

MICROJET RECORDER (180mm)

DirectLine DL424/425 Sensor Module for DL 5000 Dissolved Oxygen Probes User Manual

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Installation Manual Tracker 221

Operation Manual Part-No

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

Return loss measurement of fiber optic components

Model 144H. Product Data Sheet , Rev DB February Content

RMA 3000 Remote Meter Assemblies Specifications

Labeling and Identification Products

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Figure 1 DirectLine DL423 Sensor. Description, continued

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

PTG, SWT Series. Heat Recovery Systems

ST 3000 Smart Transmitter Series 900 Flush Mount Models Specifications

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

Hydrazine Analyzer Series 2171 Specifications

Isolated Thermocouple Module

STT 3000 Series STT250 SMART TEMPERATURE TRANSMITTER Models STT25H, STT25M, STT25D

Point recorder KS 3660

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

RAYCHEM NGC-30 COMPONENTS

/8 DIN Level Indicator

PSE-368. AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Mark 25 Ultrapure Water Conductivity Analyzer

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Model 144H. Product Data Sheet , Rev DB February Content

User Guide IM/SM3000 EN Rev. L. SM3000 Multipoint Videographic Recorder

Series Multipoint Recorder. Features. The future in Data Recording Technology is available today

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Advantages of automatic boiler bottom blowdown

Gas Detection. Touchpoint Plus. A whole new control experience

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications

Potential Applications

Transcription:

DPR 180 180 MM DIGITAL STRIP CHART RECORDER 43-DR-03-11 March 2010 PRODUCT SPECIFICATION SHEET OVERVIEW The recorder offers the best price/performance in the market today of any 180mm (7 inch) wide chart recorder. The recorder is able to monitor up to 24 analogue inputs and up to 36 digital inputs. It produces clear, fully documented charts at any speed, and in different formats, providing the best, most flexible presentation of the process data. The large, bright display, with fluorescent chart illumination, provides easy viewing of the data and chart. The flexible product configuration in 5 languages makes it easy to set up and use. The is especially suited to match the needs of chemical, pharmaceutical, power generation, metals processing, environmental monitoring, and other applications where the best chart resolution is required. MAIN FEATURES 180 mm (7 inch) chart width. 0.05% accuracy full scale. Applicable on a wide choice of actuations and ranges. Each input span is adjustable within the selected range, with up to 2 ranges per input. Universal (T/C, RTD, mv, ma, V), or linear input (mv, ma, V). Fast input scanning (20/sec.) Fluorescent display of 2 row of 16 digits, with adjustable brightness. Roll or fan fold chart with same cassette. Fully documented chart with trace color assign, thin/thick trace, alarm in red tagging, zooming, zoning, trend, tabular, messages. Channel groups available. I/O capability : up to 24 analogue inputs, up to 36 output relays, up to 36 digital inputs, up to 8 retransmitted signals. Advanced math package Fully configurable through the front keys, front PC jack or communication link. 2 chart speeds configurable from 1 to 5000 mm/h (0.04 to 200 inch/hr). Up to 48 customer messages of 50 characters each. Firmware upgradable by PC (Flash memory). Input calibration traceable per channel, or channel group. Up to 2 custom-input characterizations available. Up to 48 alarm set points freely assignable on analogue inputs, maths, communication. Up to 36 internal output relays assignable on analogue inputs, maths, events, logic inputs. Configurable Periodic chart documentation. Periodic report. Universal power supply : 100 to 240 Vac/dc. Up to 8 retransmitting outputs (4 to 20 ma). Universal comm. output: ASCII in RS232, 422/485. MODBUS RTU in RS422/485. ETHERNET/MODBUS RTU Interface, Metal door/case, IP55 rated Page 1

Clear and fully documented chart Trend printing mode _ 22.00 15 SEP 97 GROUP A 100 mm / h # 05 WATCH OIL PRESSURE _ 21.46 AL02 (04) SP 230.0 ^ ON -100 0 100 (04) Pressure Psi 200 300 400 14 21.15 DI02 = ON 1 Heater 8 Motor B 0 (08) MOTOR K Rpm 2000 DI 01= OFF CH11 30.23 Rpm CH06 150.8 m3 / h CH01 70.20 C 21.00 15 SEP 97 DI 02 = ON CH12 15.24 BAR CH07 2.350 C CH02 45.89 mv _ 20.55 AL01 ( AN01) SP 100.0 ^ OFF CH13 50.36 L/mn CH08 560.8 Rpm CH 03 12.66 Ohm 0.000 400.0 800.0 1200 1600 2000 (03) Furnace DEG C ADJUST OIL TEMPERATURE _ 20.35 AL01 (AN01) SP 100.0 ^ ON 2 Transmit _ 20.30 15 SEP 97 100 mm / h # 05 The trend printing mode offers a highly flexible documentation which includes : Date and Time, Alarm reporting with : Time, Alarm SP, Channel #, Set Point value, Alarm, Chart certification, Chart Speed with engineering unit, User defined message, Range subdivision, Recorder identification, Red on alarm, Chart range, Channel reference with tag name (Configurable), Thick channel trace, Process value, Channel tag name, Zone format, Channel reference, Engineering Unit, Tabular print out. Tabular printing mode DI01= OFF DI02 = ON CH07 2350 C BURNER CH08 560.0 Rpm MOTOR B CH09 127.3 Wh POWER CH04 258.1 PSI PRESSURE CH05 2358 K FURNACE CH06 150.8 M3 / h FLOW CH01 70.20 C HEATER CH02 45.90 mv TRANSMIT CH03 12.70 OHM COIL 23.50 15 SEP 97 DI01= OFF DI02 = OFF CH07 2350 C BURNER CH08 560.0 Rpm MOTOR B CH09 127.3 Wh POWER CH04 258.1 PSI PRESSURE CH05 2358 K FURNACE CH06 150.8 M3 / h FLOW CH01 70.20 C HEATER CH02 45.90 mv TRANSMIT CH03 12.70 OHM COIL 23.40 15 SEP 97 DI01= OFF DI02 = ON CH07 2350 C BURNER CH08 560.0 Rpm MOTOR B CH09 127.3 Wh POWER CH04 258.1 PSI PRESSURE CH05 2358 K FURNACE CH06 150.8 M3 / h FLOW CH01 70.20 C HEATER CH02 45.90 mv TRANSMIT CH03 12.70 OHM COIL 23.30 15 SEP 97 Page 2

Rugged, Simple and Modular Construction Easy to install... easy to use... easy to maintain : The with its modular design and rugged construction, simplifies maintenance. Many of the electronic assemblies and mechanical parts are common with the DPR250 thus reducing spare parts inventory. Its operator - friendly configuration keys, the sophisticated display, easy product configuration and customized charts insure accurate monitoring and recording of the process. Easy access : the access to the chart, and the ink cartridge is very easy. The simple, modular construction of plug-in modules, along with the low cost and extra long life of consumables, further reduces the maintenance cost. Universal power supply module : the universal switching mode power supply simplifies installation of the recorder by accepting voltages from 100 to 230 V ac/dc, 50/60 Hz. Local configuration : A user friendly program with local language prompts (English, French, German, Italian or Spanish) permits full configuration of the recorder using the front keys. A multilevel password protects against unauthorized changes of product configuration. Digital Display : The Vacuum fluorescent dot matrix display, is 2 lines of 16 digits, 8.5 mm (0.33 ) high. This allows for display flexibility and provides clear operator information. Display illumination is configurable to allow for improved viewing based on customer requirements. Chart illumination : The chart illumination makes traces and current printed values immediately visible, even from a distance and in any ambient light condition. Two paper types : Either chart roll or fan fold paper can be installed into the common chart cassette. The large capacity cassette holds 35 meters (115ft) of chart paper, reducing the maintenance time required between chart changes. Uses the same ink cartridge as the DPR250, thus providing for common consumables. Case Jack Ink Cartridge Door Power supply Mother Board MMI Alarm/digital boards Chassis Input boards Cassette for roll or fan fold chart Configuration keys PC Configuration Terminals PC configuration : By using the front communication jack, the recorder can be configured from a personal computer, using an optional PC interface module. In addition to configuration, the PC interface provides the ability to upload, download, modify, store the recorder configuration and initiate service diagnostics as well as being able to upgrade the recorder s product firmware. The PC Configuration software allows the creation of a custom characterization of up to 50 points for special ranges. Page 3

DPR 180 FUNCTIONAL SPECIFICATIONS Technical data Technology Microprocessor-based (32 bits), with non volatile memory. Flash memory for product software upgrade, or specials, via the front jack. Analogue inputs No. of inputs From 4 up to 24 in groups of 4. Input boards 2 types : 4 linear inputs per board : mv, V, ma 4 universal inputs per board : mv, V, ma, T/C, RTD, Ohms Signal source Thermocouple with cold junction compensation, or with remote compensation temperature configurable between 0 to 80ºC (32 to 176ºF) Line resistance up to 1000 Ohms for T/C, mv, ma, V RTD Pt100 Ohms, 3 wire connections, 40 Ohms balanced max. Basic math Square root extraction or channel differential are standard. functions Filter Digital filter configurable per input from 0 to 99 sec. Field calibration Channel calibration 0 to 100% span (or calibration of a group of identical channels) can be made to certify sensor loop. Burnout T/C, mv, V (except following ranges) configurable to upscale, downscale or none Volt : -500, 0, 500 mv ; -1, 0, 1V ; -2, 0, 2V; -5, 0, 5V ; 0, 10V ; -10, 0, 10V : Inherent to Zero volt. RTD : inherent upscale ; ma : inherent downscale. Scanning time 2 channels = 105 msec, 4 ch = 210 msec, 8 ch = 420 msec, 12 ch = 630 msec, 16 ch = 840 msec, 20 ch = 1 sec, 24 ch = 1.2 sec Input impedance 10 MOhms for T/C and mv inputs; > 1 MOhm for V input Stray rejection Series mode > 60 db. Common mode at 120 Vac > 130 db Display Page 4 Fluorescent display 2 rows of 16 digits, 8.5 mm (.33 inch) high, matrix display. Can display 1 or 2 PV values (5 digits) per line, engineering units (5 digits), alarm status, tag name, math, speed, event messages etc. Brightness The display brightness is configurable Record Chart 180 mm (7.09 ) width Traces Up to 24 traces, configurable in 6 colors, thin or thick traces, plus digital traces Trace Traces are configurable on analogue inputs, math, communication or digital inputs assignment Scaling Per input, up to 2 analogue scales can be configured to be printed on the chart, with engineering units, channel reference and tag name. Each input can be configured independently. The scale can be linear, with up to 10 sub-divisions Chart length Chart speed Product configuration Print mode Trend : Up to 24 traces, with periodic chart documentation configurable in time, from 1 minute to 24 hours with date, time, scales, digital PV print-out over traces or on blank paper, with channel reference, digital traces, alarm messages and customer message. Tabular : Tabular print-out configurable in time from 1 to 1440 minutes with channel number, tag name, digital PV value, engineering unit, alarm status. Zoning Each input can be scaled between 0 to 100% of the chart (minimum zone = 20%). Printing group Up to 2 groups of channels can be defined, with printing selection by : Alarm, logic inputs or keypad Pen carriage 1.4 second full scale speed Roll or fan fold chart 35 meters (115 ft) 1 or 2 chart speed, fully configurable, selected by : Logic input, alarm communication, front key. Speed setting Speeds 1 and 2 are configurable from 1 up to 5000 mm/hr (0.04 to 200 in/hr) Resolution Chart resolution is 0.19 mm (0.0075 ) Access The configuration can be accessed using front keys, PC configurator, or ASCII communication with LPCS software. Protection 2 password levels protect the unit configuration from unauthorized access. Level 1 Front keyboard = limited access, Level 2 = full protection. Configurable and alphanumeric keys allow the operator to change the recorder operation PC configuration Through the front jack, the unit can be configured from a PC using a Honeywell PC interface. This provides the facility to copy the product configuration, modify, store, download or upload the configuration, access service diagnostics, and also to upgrade the recorder firmware.

Technical data (continued) Logic inputs (optional) Number of inputs Up to 36 input contacts, organized in groups of 6 contacts per card Dry contacts (5 ma - 5 Vdc) Actions Change speed 1 to speed 2, tab interval 1 to 2, digital print-out, print message, print inhibit, event traces, print math calculations. Change range, start/stop math operations Change print group, actuate a relay output Up to 20 event traces are configurable in color and position from 0 to 100% of the chart Alarms Set points Up to 48 set points, freely assignable to analogue inputs, math or communication. Alarm type High, low, change rate low, change rate high, change rate high-low or deviation with configurable alarm occurrence. Actions Can trigger a message, print channel in red in alarm, print in alarm, change the range, change the speed/tabular, print digital PV's Start/stop the math, select the print group, actuate a relay output Relay output (optional) Up to 36 internal relays : 2 A, 250 Vac on resistive load. 1 SPST contact output, normally closed contact (NC), configurable to normally open (NO). Configurable alarm relay acknowledgement. Alarm event The recorder can be configured to display events such as : 1 alarm, 1 channel in Alphanumeric documentation User-Defined Actuations Mathematic package (optional) Communication (optional) PCMCIA (optional) Retransmitting signals (optional) Messages Process Values Tag name Chart scales Periodic reports burnout, paper out, battery fail, communication interrupted Up to 48 freely assignable messages of 50 characters each Can be printed with or without date and time over the traces, by alarms, logic inputs, communication, when alarm is ON, OFF or ON/OFF. Periodic digital print-out at time intervals configurable from 1 minute to 24 hours or through alarms, digital inputs, communication. Each channel can have up to an 8 character name each can be configured from 0 to 9 subdivisions startup time and period configurable Min, Max, average of selected channels or (math computation) are printed in alphanumeric. Report size max. = 20 lines. Up to 50 breakpoints can be used to define a custom range/actuation. Up to 2 ranges can be defined using the PC Configurator. Polynomial characterization available as special. Many functions are available such as : Basic math, SqRt, Fo, mass flow totalization, energy consumption, averages, timers, min., max., carbon potential, alarm/logic pulse totalization, RH. The calculations are stored during power interruption. Actions The results can be recorded as a trace, a tabular print-out, a periodic report, sent to the communication link, or used to generate a current output signal Protocols ASCII in RS232, 422/485. MODBUS RTU in RS422/485. ETHERNET/MODBUS RTU Interface, Interface configured with standard IP address and is utilized with 3 rd party software that provides TCP/Modbus driver and OPC capability. Actions Archiving of PV traces, alarms and events with file names, file size is 24Mbytes max. Logging time selectable from 1 second up to 30 minutes. PC Analysis TrendManager Pro provides an easy and powerful way to analyze trend, alarm and event files as well as to export them in spreadsheet format (CSV). Current output Up to 8 signals, 4 to 20 ma dc, can be generated by the recorder (Organized in blocks of 4 output signals) Max. Line impedance = 800 Ohms These can be configured for : analogue traces, math calculations, PV's from the communication link. The zero and span are configurable. Page 5

Technical data (continued) Clock timer Format Year, month, hour, minute can be set Power interruption Battery backed (10 years time, 3 years power off) Accuracy 10-5 at reference conditions Power supply 100 to 230 Vac/dc, (24 Vac/dc on request). Consumption = 100 VA max Packaging Weight 18 Kg max. (38 lbs) Front bezel 310 x 317 mm (12.2 x 12.5 inches) Panel cutout 278 x 278 mm (10.9 x 10.9 inches) Depth 320 mm (12.6 inch) including the rear cover Front protection IP55 Lock Latch, optional key DIN 43832-N Door Die cast aluminum : Dark gray or black (optional), door opens to 180º Mounting Panel mounting ± 30º from the horizontal Wiring Screw terminals : Terminal blocks plug on to the boards at the back of the recorder Noise immunity Safety protection This product is in conformity with the protection requirements of the following European Council Directives: 73/23/EEC, the Low Voltage Directive and 89/336/EEC, the EMC Directive. Conformity of this product with any other CE Mark Directive(s) shall not be assumed. EMC Classification: EN 50081-2-1993 Electromagnetic Compatibility General Emission Standard, Part 2: Industrial Environment. EN 50082-2-1995 Electromagnetic Compatibility General Immunity Standard, Part 2:Industrial Environment. Complies with EN61010-1 and UL 3121 for process control instrumentation. Pollution Degree 2. Installation Category II Electrical insulation Input/input Input/logic/grd alarm relay/grd Input/line; Line/grd; Cur output/grd Continuous operation at 280 Vac or 400 Vdc (except for RTD) Test voltage 2.1 kv dc for 1 minute Test voltage 3,25kV dc for 1 minute Test voltage 3,25kV dc for 1 minute Test voltage 3,25kV dc for 1 minute Test voltage 3,25kV dc for 1 minute Test voltage 500 Vdc for 1 minute Temperature Ambient 0 to 50ºC (32 to 132ºF), 0 to 40ºC (32 to 104ºF) for fan fold paper Storage -40 to 70ºC (-40 to 160ºF) Humidity Roll chart 10 to 90% RH non-condensing Fan fold 15 to 80% RH non-condensing Vibrations Frequency 10 to 60 Hz, amplitude 0.07 mm, 60 to150 Hz acceleration1g Accuracy Reference conditions Temperature = 23ºC ± 2ºC (73ºF ± 3ºF) Humidity = 65% RH ± 5% Line voltage = Nominal ± 1% Source resistance = 0 Ohm Series mode and common mode = 0 V Frequency = Nominal ± 1% Accuracy Field calibration accuracy 0.05% of the selected range (IEC 873), Chart resolution : 0.18 mm (0.007 ). Cold junction accuracy : ± 0.5ºC (32.9ºF) Rated limits Parameters Rated limits Influence on accuracy and associated drifts Temperature 0 to 50ºC (32 to 120ºF) 0.15% per 10ºC (50ºF ) of change (note A) Cold junction 0.3ºC/10ºC (32.5ºF /50ºF) Supply voltage 85 to 250 V No influence Source resistance T/C, mv 6 μv per 400 Ohms of line resistance max. = 1000 Ohms. RTD 0.1ºC (33.8ºF ) per Ohm in each wire balanced leads. 40 Ohms max. (From 0 to 400 ºC (32 to 752ºF) Humidity 10 to 90% RH at 25ºC 0.1% max Long-term stability 0.1% per year Page 6

Available Ranges) Linear RTD/Ohms Thermocouples mv Pt 100 at 0ºC J I S J -50, 0, 150ºC S 0, 1600ºC U -50, 0, 150ºC 0 to 10 mv -50, 0, 150ºC -50, 0, 150ºC J -58, 0, 302ºF S 32, 2912ºF U -58, 0, 302ºF -10, 0, +10 mv -58, 0, 302ºF -58, 0, 302ºF J 0, 400ºC S -20, 0, 1760ºC U 0, 150ºC 0, 20 mv 0, 100ºC** 0, 100ºC** J 32, 752ºF S -4, 0, 3200ºF U 32, 302ºF -20, 0, +20 mv 32, 212ºF** 32, 212ºF** J -200, 0, 870ºC U 50, 150ºC 0, 50 mv 0, 200ºC 0, 200ºC J -328, 0, 1598ºF N 0, 400ºC U 122, 302ºF -50, 0, +50mV 32, 392ºF 32, 392ºF N 32, 752ºF U -200, 0, 400ºC 10, 50 mv 0, 400ºC 0, 400ºC L -50, 0, 150ºC N 0, 800ºC U -328, 0, 752ºF 0, 100 mv 32, 752ºF 32, 752ºF L -58, 0, 302ºF N 32, 1472ºF -100, 0,+100mV -200, 0, 800ºC -200, 0, 500ºC L 0, 400ºC N 0, 1200ºC NiMo 0, 1400ºC 0, 500 mv -328, 0, 1472ºF -328, 0, 932ºF L 32, 752ºF N 32, 2192ºF NiMo 32, 2552ºF -500, 0, +500mV L -200, 0, 870ºC N -200, 0, 1300ºC MoCo 0, 1400ºC Ni 50 ohms Ref. range L -328, 0, 1598ºF N -328, 0, 2372ºF MoCo 32, 2552ºF Volt -80, 0, 320ºC 0, 320ºC 0, 1 V -112, 0, 608ºF 32, 608ºF K 0, 400ºC T -50, 0, 150ºC W-W26 Ref. range 0, 2 V K 32, 752ºF T -58, 0, 302ºF -20, 0, 2320ºC 400, 2300ºC -2, 0, +2V Ni 508 ohms K 0, 800ºC T 0, 150ºC -4, 0, 4208ºF 750, 4200ºF 0, 5 V -80, 0, 150ºC K 32, 1472ºF T 32, 302ºF -5, 0, +5 V -112, 0, 302ºF K 0, 1200ºC T 50, 150ºC W5-W26 Ref. range 1,5 V K 32, 2192ºF T 122, 302ºF -20, 0, 2320ºC 400, 2300ºC 0, 10 V Cu 10 Ohms K -200, 0, 1370ºC T -200, 0, 400ºC -4, 0, 4208ºF 750, 4200ºF -10, 0, +10 V -20, 0, 250ºC** K-328, 0, 2498ºF T -328, 0, 752ºF -4, 0, 482ºF PR 20-40 Ref. range ma R -20, 0, 1760ºC 0, 1800ºC 600, 1800ºC 0, 20 ma Ohms R -4, 0, 3200ºF 32, 3272ºF 1110, 3300ºF 4, 20 ma 0, 200 ohms Ref. range 0, 2000 ohms B 40, 1820ºC 400, 1820ºC B 104, 3308ºF 752, 3308ºF Notes : 1. Ranges with ** have an accuracy of 0.25%. 2. For non linear temperature transmitter, the transmitter range MUST be identical to the input range of the recorder. 3. The ma inputs has to be connected on a 250 Ohms input across the input terminals. 4. 0.5% per 10 C on Cu 10 ohms; 0.3% per 10ºC on Pt100< 200ºC 5. The Reference range is the same as the stated range unless noted. Minimum system requirements for PC software NOTE: Make sure you are an Administrator before installing the product. Windows 7 Professional, Ultimate or Enterprise OS 32-bit or 64-bit edition requires 1 GHz Processor, 2GB RAM and 15GB Hard Disk Space Windows XP SP1 professional requires a 233 Mhz CPU with 128 MB of RAM Windows 2000 SP4 professional requires a Pentium 133 Mhz CPU with 64 MB of RAM Windows NT Workstation 4.0 SP5 requires a 486 Mhz CPU with 32 MB of RAM Windows 98SE requires a Pentium 150MHz processor with 32 MB of RAM 10MB free on your hard disk for the PC Configuration software. Recommended video resolution: 800x600 or higher. Page 7

Dimensions 17.5 0.67 310 12.21 275x275 10.88x10.88 317 12.48 40 max 1.57 320 12.6 45 1.77 278 x 278 10.95 x 10.95 PANEL CUT OUT 75 min Millimeters/Inches 3 min Page 8

Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty work-manship. Contact your local sales office of warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair of replace without charge those items it finds defective. The foregoing is Buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Page 9

Sales and Service For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one of the offices below. ASIA PACIFIC Control Products Asia Pacific Headquarters Phone: +(65) 6355-2828 Fax: +(65) 6445-3033 Asia Pacific Global Technical Support Field Instruments Phone: +65 6580 3156 Fax: +65 6445-3033 Process Instruments Phone: (603) 76950 4777 Fax: (603) 7958 8922 Australia Honeywell Limited Phone: +(61) 7-3846 1255 FAX: +(61) 7-3840 6481 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 China PRC - Beijing Honeywell China Inc. Phone: +(86-10) 8458-3280 Fax: +(86-10) 8458-4650 China PRC - Shanghai Honeywell China Inc. Phone: (86-21) 5257-4568 Fax: (86-21) 6237-2826 China PRC - Chengdu Honeywell China Inc. Phone: +(86-28) 8678-6348 Fax: +(86-28) 8678-7061 China PRC - Xi an Honeywell China Ltd - Xi an. Phone: +(86-29) 8833-7490 Fax: +(86-29) 8833-7489 China PRC - Shenzhen- Honeywell China Inc. Phone: +(86) 755-2518- 1226 Fax: +(86) 755-2518-1221 Indonesia PT Honeywell Indonesia Phone: +(62) 21-535-8833 FAX: +(62) 21-5367 1008 India Automation India Ltd. Honeywell Ltd. Phone:+(91) 5603-9400 Fax: +(91) 5603-9600 Japan Honeywell Inc. Phone: +(81) 3 6730 7150 Fax: +(81) 3 6730 7228 Malaysia Honeywell Engineering Sdn Bhd Phone: +(60-3) 7950-4776 Fax: +(60-3) 7958-8922 New Zealand Honeywell Limited Phone: +(64-9) 623-5052 Fax: +(64-9) 623-5060 Toll Free (0800) 202-088 Philippines Honeywell Systems (Philippines) Inc. Phone: +(63-2) 633-2830- 31/ 636 1661-62 Fax: +(63-2) 638-4013 Singapore Honeywell Pte Ltd. Phone: +(65) 6580 3278 Fax: +(65) 6445-3033 South Korea Honeywell Korea Co Ltd Phone: +(822) 799 6315 Fax: +(822) 792 9015 Thailand Honeywell Systems (Thailand) Ltd. Phone: +(662) 693-3099 FAX: +(662) 693-3089 Taiwan R.O.C. Honeywell Taiwan Ltd. Phone: +(886-2) 2245-1000 FAX: +(886-2) 2245-3241 SE Asia Countries see Honeywell Pte Ltd (Singapore) for: Pakistan, Cambodia, Guam, Laos, Myanmar, Vietnam, East Timor SE Asia Countries see Honeywell Automation India Ltd for: Bangladesh Nepal Sri Lanka EUROPE Austria Honeywell Austria GmbH Phone: +43 (316)400123 FAX: +43 (316)40017 Belgium Honeywell SA/NV Phone: +32 (0) 2 728 24 07 FAX: +32 (0) 2 728 22 45 Bulgaria Honeywell EOOD Phone: +(359) 2 40 20 900 FAX: +(359) 2 40 20 990 Czech Republic Honeywell spol. s.r.o. Phone: +420 242 442 232 FAX: +420 242 442 131 Denmark Honeywell A/S Phone: +(45) 39 55 55 55 FAX: +(45) 39 55 55 58 Finland Honeywell OY Phone: +358 (0)20752 2753 FAX: +358 (0) 20752 2751 France Honeywell SA Phone: +33 (0)1 60198075 FAX: +33 (0)1 60198201 Germany Honeywell AG Phone: +49 (69)8064-299 FAX: +49 (69)806497336 Hungary Honeywell Kft. Phone: +36-1-451 4300 FAX: +36-1-451 4343 Italy Honeywell S.p.A. Phone:+390292146307 FAX: +39 0292146377 The Netherlands Honeywell B.V. Phone: +31 (0) 20 5656200 FAX: +31 (0) 20 5656210 Norway Honeywell A/S Phone: (45) 39 55 55 55 Poland Honeywell Sp. zo.o Phone: +48-22-6060900 FAX: +48-22-6060901 Portugal Honeywell Portugal Lda Phone: +351 21 424 5000 FAX: +351 21 424 50 99 Romania Honeywell Bucharest Phone: +40 (0) 21 2316437 FAX: +40 (0) 21 2316439 Russian Federation (RF), ZAO "Honeywell" Phone: +7 (095) 796 98 00 FAX: +7 (495) 797 99 64 Slovak Republic Honeywell s.r.o. Phone: +421-2-58247 410 FAX: +421-2-58247 415 Spain Honeywell S.A. Phone: +34 (0)91313 61 00 FAX: +34 (0)91313 61 30 Sweden Honeywell AB Phone: +(46) 8 775 55 00 FAX: +(46) 8 775 56 00 Switzerland Honeywell AG Phone: +41 18552448 FAX: +(41) 1 855 24 45 Turkey Honeywell Turkey A.S. Phone: +90 216 578 71 00 FAX: +90 216 575 66 35 Ukraine Honeywell Tel: +380-44-201 44 74 Fax: +380-44-201-44-75 United Kingdom Honeywell Control Systems Ltd. Phone: +44 (0)1344 655251 FAX: +44 (0) 1344 655554 MIDDLE EAST Abu Dhabi U A E Middle East Headquarters Honeywell Middle East Ltd. Phone: +971 2 4041246 FAX: +971 2 4432536 Sultanate of Oman Honeywell & Co Oman LLC Phone: +968 24 701153/ Ext.33 FAX +968 24 787351 Saudia Arabia Honeywell Turki Arabia Ltd Jubail Office Phone: +966-3-341-0140 Fax: +966-3-341-0216 Honeywell - ATCO Dammam Office Phone: 0096638304584 Fax: 0096638338059 Kuwait Honeywell Kuwait KSC Phone: +965 242 1327 to 30 Fax: +965 242 8315 And Phone: +965 326 2934/1821Fax: +965 326 1714 AFRICA Mediterranean & African Distributors Honeywell SpA Phone: +39 (02) 250 10 604 FAX: +39 (02) 250 10 659 South Africa (Republic of) and sub saharan Honeywell Southern Africa Honeywell S.A. Pty. Ltd. Phone: +27 11 6958000 FAX +27 118051504 NORTH AMERICA Canada Honeywell LTD Phone: 1-800-737-3360 FAX: 1-800-565-4130 USA Honeywell Process Solutions, Phone: 1-800-423-9883 or 1-800-343-0228 Email: askssc@honeywell.com SOUTH AMERICA Argentina Honeywell S.A.I.C. Phone: +(54-11) 4383-3637 FAX: +(54-11) 4325-6470 Brazil Honeywell do Brasil & Cia Phone: +(55-11) 7266-1900 FAX: +(55-11) 7266-1905 Chile Honeywell Chile, S.A. Phone: +(56-2) 233-0688 FAX: +(56-2) 231-6679 Mexico Honeywell S.A. de C.V. Phone: +(52) 55 5259-1966 FAX: +(52) 55 5570-2985 Puerto Rico Honeywell Inc. Phone: +(809) 792-7075 FAX: +(809) 792-0053 Trinidad Honeywell Inc. Phone: +(868) 624-3964 FAX: +(868) 624-3969 Venezuela Honeywell CA Phone: +(58-2) 238-0211 FAX: +(58-2) 238-3391 Honeywell Process Solutions 1860 West Rose Garden Lane 43-DR-03-11 Phoenix, Arizona 85027 March 2010 Phone: 1-800-423-9883 or 1-800-343-0228 www.honeywell.com/ps 2009-10 Honeywell International Inc.

43-DR-16U-16 Issue 22 Page 1 of 5 Recorder 180mm Strip Chart Recorder Model Selection Guide Instructions Refer to Supplementary Ordering Data before order entry. Select the desired Key Number. The arrow to the right marks the selection available. Make selections from Tables I through VII using the column below the proper arrow. A dot ( ) denotes unrestricted availability. A letter denotes restricted availability. A complete Model Number must have the designated number of digits in each table. Key Number I II III IV D18 - - - - _ - V VI VII - - _ KEY NUMBER Selection Availability Description DPR 180 Strip Chart Recorder D18 TABLE I - Analog Inputs (Note 1) Input Card 1 0 _ (Slot A) 4 Linear Inputs (Channel 1 to 4) L _ 4 Universal Inputs (Channel 1 to 4) U _ Input Card 2 _ 0 (Slot B) 4 Linear Inputs (Channel 5 to 8) _ L 4 Universal Inputs (Channel 5 to 8) _ U Input Card 3 0 _ (Slot C) 4 Linear Inputs (Channel 9 to 12) L _ 4 Universal Inputs (Channel 9 to 12) U _ Input Card 4 _ 0 (Slot D) 4 Linear Inputs (Channel 13 to 16) _ L 4 Universal Inputs (Channel 13 to 16) _ U Input Card 5 0 _ (Slot E) 4 Linear Inputs (Channel 17 to 20) L _ 4 Universal Inputs (Channel 17 to 20) U _ Input Card 6 _ 0 (Slot F) 4 Linear Inputs (Channel 21 to 24) _ L 4 Universal Inputs (Channel 21 to 24) _ U

43-DR-16U-16 Issue 22 Page 2 of 5 Availability TABLE II - Digital Inputs/Alarms/Analog Outputs Selection D18 0 _ Slot J 6 Alarm Relay Outputs (Alarm 1 to 6) A _ 6 Digital Inputs (Digital 1 to 6) D 0 Slot K 6 Alarm Relay Outputs (Alarm 7 to 12) _ A 6 Digital Inputs (Digital 7 to 12) _ D 0 _ Slot L 6 Alarm Relay Outputs (Alarm 13 to 18) A _ 6 Digital Inputs (Digital 13 to 8) D 0 Slot M 6 Alarm Relay Outputs (Alarm 19 to24) _ A 6 Digital Inputs (Digital 19 to 24) _ D 0 _ Slot N 6 Alarm Relay Outputs (Alarm 25 to 30) A _ 6 Digital Inputs (Digital 25 to 30) D _ 4 Auxiliary Current Outputs (1 to 4) C 0 Slot P 6 Alarm Relay Outputs (Alarm 31 to 36) _ A 6 Digital Inputs (Digital 31 to 36) _ D 4 Auxiliary Current Outputs (5 to 8) _ C TABLE III - Options Communications 0 _ Universal Communication (ASCII - Modbus) 1 _ Ethernet Interface 2 _ d PCMCIA _ 0 PCMCIA Interface (Note 6) _ A Math 0 _ Math Package A _ Future _ 0 TABLE IV - Door and Case Grey Door, Glass Window, with Latch, Standard Case 0 Grey Door, Glass Window, with key Lock, Standard Case 1 Grey Door, Plastic Window, with Latch, Standard Case 2 Grey Door, Plastic Window, with key Lock, Standard Case 3 Black Door, Glass Window, with Latch, Black Case Black Door, Glass Window, with key Lock, Black Case E F

43-DR-16U-16 Issue 22 Page 3 of 5 Availability TABLE V - Miscellaneous Selection D18 0 0 Test Report (Calibration Certificate) (Note 5) _ A Certificate of Conformance _ B 0 _ Product Configuration (Note 3) A _ Product Configuration with User Defined Actuation (Note 3) B _ User Defined Actuation (Note 3) U _ (Future) _ 0 CSA Approval/NRTL/C (Note 4) _ C TABLE VI - Factory Specials 00 Special ST # (refer special list) XX TABLE VII - Language/Prompts/Manuals Product Information on CD 0 English Manual E French Manual F German Manual G Italian Prompts/English Manual I Spanish Manual S RESTRICTIONS Restriction Letter Available Only With Not Available With Table Selection Table Selection d II _ A, _ D, _ C Notes: 1 A 250 ohm resistor is required for ma input actuations. Order the required quantity using Part Number 46181080-503. See Parts Price Book for pricing. 2 Consult Fort Washington for pricing and availability. 3 Customer must complete "Configuration Worksheets" and attach to order or send to York Customer Service (Fax: 717-771-8236). 4 NRTL/C indicates product safety compliance approval by a Nationally Recognized Testing Laboratory of which UL and CSA are both OSHA accredited NRTL's. 5 Calibration Test Reports/Certificates require specific Range and Input Actuation data from the customer. Form F3399 Supplemental Data must be completed. This can be downloaded from the Honeywell SalesNet site or the Global Technical Services site: <http://content.honeywell.com/ipc/faq/> FAX to York Customer Service at 717-771-8236. 6 PCMCIA Compact Flash Adapter and Compact Flash Cards can be ordered separately. The stored data on the Compact Flash Card is accessible using TrendManager Pro V5 (TMPCON5).

43-DR-16U-16 Issue 22 Page 4 of 5 USER DEFINED ACTUATION DPR 180/250 Fax to York Customer Service 717-771-8236 CUSTOMER ORDER No. SALES ORDER No. TYPE OF ACTUATION - T/C LINEAR (mv) Ma V RTD (Check one) If thermocouple - complete table for Recorder Operating Temperature for Cold Junction Compensation Actuation Cold Junc. Eng. Unit Electrical Actuation Cold Junc. Eng. Unit Electrical 1 Value Deg. C Value (mv) 2 Value Deg. C Value (mv) Lowest Lowest Average Average Highest Highest USER DEFINED ACTUATION TABLE 1 Enter values for custom actuation (max 50 SEGMENTS) Segment ENG Electrica Segment ENG Electrical Segment ENG Electrical Number VALUE VALUE Number VALUE VALUE Number VALUE VALUE 1 18 35 2 19 36 3 20 37 4 21 38 5 22 39 6 23 40 7 24 41 8 25 42 9 26 43 10 27 44 11 28 45 12 29 46 13 30 47 14 31 48 15 32 49 16 33 50 17 34 51 USER DEFINED ACTUATION TABLE 2 Enter values for custom actuation (max 50 SEGMENTS) Segment ENG Electrica Segment ENG Electrical Segment ENG Electrical Number VALUE VALUE Number VALUE VALUE Number VALUE VALUE 1 18 35 2 19 36 3 20 37 4 21 38 5 22 39 6 23 40 7 24 41 8 25 42 9 26 43 10 27 44 11 28 45 12 29 46 13 30 47 14 31 48 15 32 49 16 33 50 17 34 51

43-DR-16U-16 Issue 22 Page 5 of 5 /250 Parts and Accessories Description Specify Chart Roll, 100 Divisions (35 meters) - 46190052-100 Fan Fold, 100 Divisions (35 meters) - 46190051-100 Chart Roll, 100 Divisions (35 meters) - DPR250 46182708-001 Fan Fold, 100 Divisions (35 meters) - DPR250 46182707-001 Ink Cartridge (6 color) 46182712-001 4 Resistor = 250 ohms each 46181080-503 Application Software for Product Configuration (PC Configurator) 46190407-001 Cable (jack) to PC Interface 46225600-001 Cable PC to PC Interface 46210040-001 Cable Communication Board to PC (2 meters) 46210098-501 Cable Clamp (8 cables) 46210075-501 PC Interface (interface + cables + diskette) 46187121-001 Communications Upgrade Kit 46190260-501 Rack Mounting Kit - DPR250 46182883-001 Grease Kit for Print Carriage 46210096-501 Compac Flash PCMCIA Adapter 50001014-501 Compac Flash Card - 32 MB 50001011-501 Compac Flash Card - 64 MB 50001011-502 Adapter Mounting Plate (16" x 15") - 46190415-501 Adapter Mounting Plate (18.25" x 16.25") - DPR250 30756326-001 Portable Case Assembly 46190112-501 DPR250 Portable Case Assembly 46190147-501 TrendManager Pro 50016133-501 6 Logic Input Board 46190311-501 6 Relay Output Board 46190308-501 4 Universal Input Board 46190305-501 4 Auxiliary Output Board 46190314-501 PCMCIA Upgrade Kit 46190163-501 Math Upgrade Kit 46190424-501 Consult Honeywell Order Entry Systems for current parts pricing. Listed Specials Table VI (ST#) Description ST# Molten Metal Application IPTS 90 Curve (Note 1) 02 Molten Metal Application IPTS 48 Curve (Note 1) 04 "E" T/C Range -200 to 900 o C (Note: NiMo Range Unavailable) 07 Note 1: For Molten Metal Application the recommended Model is D18-U00000-AD0000-00A0-E-0000-02 or 04-U Or D25-U0000000-AD000000-00A-E-0000-02 or 04-U