Similar documents
Perspective on transition to Air-conditioners with Natural Refrigerants The Godrej Experience

Development and Handling of Hydrocarbon Air-conditioners The Godrej Experience

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

FACT SHEET 9 Large Air-Conditioning (air-to-air)

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Possibilities of the RAC sector transformation a technical perspective

Bringing Hydrocarbon to the Market Training & Certification

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

FACT SHEET 9 Large Air-Conditioning (air-to-air)

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

CHAPTER 1 INTRODUCTION

International Journal of Advance Engineering and Research Development

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Energy Saving & Eco-Friendly Refrigerant

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Low GWP Refrigerants for Air Conditioning Applications

Making equipment decisions

Reducing Refrigerant Leakage

Product Brochure 2018 NEW. Flexis. High-Wall Split Systems

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Global Solutions for Ammonia Industrial Refrigeration

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Refrigerant Dryers DRY with PDP Indicator

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

CHAPTER 1 INTRODUCTION

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

Ammonia. Background on ammonia as a refrigerant

Transitioning to Alternatives and Challenges in Japan

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

FACT SHEET 6 Transport Refrigeration

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Overview of refrigerant alternatives in the air conditioning sector *

Evaluation and Development of Air-conditioners using Low GWP Refrigerant

Low GWP alternative refrigerants to R404A

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

AMENDMENT NO. 1 TO IS 2878:2004 FIRE EXTINGUISHER, CARBON DIOXIDE TYPE (PORTABLE AND TROLLEY MOUNTED) - SPECIFICATION

The Industry s Most Complete Refrigeration Source

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

Actions to Control Emission of HFCs in Japan

Scroll Chillers Transition from HCFC-22 to HFCs

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Legislation & Standards

Current status of Japan s legislation on F-gases and RACHP using Low-GWP Refrigerants

Study of R161 Refrigerant for Residential Airconditioning

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

Ductable Range of Air Conditioners

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

Evaluation of HCFC Alternative Refrigerants

ARE YOU AN AUTHORISED REFRIGERATION GAS PRACTITIONER?

Natural refrigerant trends in EU, Japan & North America

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

Effectively Managing the Transition to Lower GWP Refrigerants

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

United Nations Environment Programme

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Policies and Measures for HCFCs in Japan

Contents TERI. Part I Background. Part II Introduction of Research on Flammability of Lower GWP Refrigerantds by TERI.

Guidance for Stationary Refrigeration & Air-Conditioning

Member Briefing JAPAN

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Cooling Only & Heat Pump

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

Natural refrigerants - naturally efficient

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

The Current Path of Refrigerants

Hall 7A. Chillventa Specialist Forums 2018 Chillventa Fachforen NürnbergMesse, Arbeitstitel, Datum 1

Brazed Plate Heat Exchanger for CO Applications

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Challenges and responses in refrigerant conversion

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

March 2014 AHRI Presents Research Findings at Low-GWP AREP Conference

Introduction of Panasonic New CO2 refrigeration system (Technical Part)

Executive Summary. Direct Investigation into the Safety Regulation of Eco-friendly Refrigerants

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

The natural solution for domestic refrigeration

An Efficient Cold Store Facility

Refrigerant Rule Update

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

ISHRAE. Guideline document to ISO Version 1 Feb Indian Society of Heating, Refrigerating and Air Conditioning Engineers

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Air to Water Heat Pump Utilising Natural Refrigerant C02

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

A study on retrofit methodologies for legacy air-conditioning systems to reduce their impact on global warming and ozone depletion

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

Transcription:

Energy Efficiency & Climate Change Benefits from Room Air Conditioners Godrej Perspective Mr.B.J.Wadia Executive Vice-President (Innovation and Technology)

Introduction Who we are Godrej & Boyce Mfg. Co. Ltd -The Flagship Company of the Godrej Group Into Business since 1897 One of the largest privately held Industrial Corporations Annual Turnover of Rs. 68 Billion for FY 2012-13 All India presence with 20 Branches & 51 Showrooms Family of 11000 + employees

Introduction The Appliance Division The largest business unit of Godrej & Boyce Mfg. Co. Ltd Established in 1958 Annual Turnover Rs. 17 Billion (FY 2012-13) Products Refrigerators Washing Machines Air-conditioners Chotukool(Thermo-electric refrigerator) Introduced 100% CFC free refrigerators in 2000, using hydrocarbon technology the first Indian company to do so

Introduction Commitment to the Environment Land area in Vikhroli -3200 acres of which 1750 acres is reserved for conservation of Mangrove Forests the lungs of Mumbai

COMMITTED TO ENVIRONMENT PROTECTION & SERVICE TO MANKIND Godrej Vikhroli Campus Udayachal School Godrej Memorial Hospital Mangroves

GODREJ : COMMITTED TO GREEN Phase-out- a must for environment protection. Country s plan to phase-out has to be achieved. Godrej will support the Government and would look for a one time changeover avoiding a 2nd changeover or an intermittent solution. Godrej appreciated and participated in the ECOFRIG project (September 1992 -a trilateral agreement between the Swiss, German & Indian governments, to assist the Indian Industry in adaptive research and development to commercialize ozone-friendly, climatefriendly and energy-efficient refrigeration technologies.).

GODREJ : COMMITTED TO BE GREEN Godrej is committed to providing totally GREEN and energy efficient green products. - Energy efficient during use of the product. Thus giving lower life-cycle cost. - Energy efficient for manufacture. Thus giving lower 1st time cost.

GODREJ : Refrigerator Experience FoamProject(Phase1): Pilot Foaming Plant at Godrej commissioned and TuV certified in June 1996. Godrej s Proposal for Foam Project approved by Ex Comm of Multilateral Fund(MLF) in 1997. New machinery ordered from Italy in August 1998. Conversion to 100% ozone-friendly foaming in September 1999. Refrigerant& Compressor Project(Phase 2): Compressors & Refrigerators tested at various places like FKW, Foron, Liebherr, for assessment. Pilot Refrigerant Charging Plant at Godrej commissioned in February 1999. Godrej s Proposal for Refrigerant & Compressor Project approved by ExComm of Multilateral Fund(MLF) in 2000. GODREJ CONVERTS TO ENVIRONMENT FRIENDLY REFRIGERATORS IN 2000

GODREJ : Refrigerator Experience Godrej has a complete range of Hydrocarbon based environment friendly Refrigerators Direct cool and Frostfree type. Godrej is continually working on providing energy efficient products to its family of customers. The Edge range of refrigerators is the first complete 5 Star energy efficient product range for the masses where theimpactofenergysavingwillbehighforthecountry. Godrej Appliances Division has received numerous recognitions of its contribution towards Energy Efficiency.

Agenda Background Product Development Manufacturing Set-up Service Training & Network Further Research

Background The trigger Decision of the 19 th MOP to the Montreal Protocol - Accelerated phase out of HCFCs German Ministry of Environment under it s International Climate Initiative through GIZ invited Indian air-conditioner manufacturers to participate in a project on HC-290 to reduce greenhouse gas emissions Godrej responded to the call.

Background Majority of the Split AC products still use HCFC-22 Due to phase out, suppliers must soon switch to non-ods Industry view is there is no suitable alternative R-410A, R-407C, similar blends have high GWP, likely to be restricted in near future and (for R-410A) poor performance at high ambient HFC-32 has high GWP, high ambient performance is much worse than HCFC-22, system concepts for higher efficiencies bounded by a large number of patents HCs viewed as unsuitable inhibitions from flammability, lack of experience At least two enterprises have development of ACs using HC-290 AC market in India 2012 annual AC production about 10.5 million Demand of 3.4 million Annual growth rate ~10% 1/5 th for window units, remainder for split ACs 95% of the market is for 1TR (~3.5 kw) and more so 1.5TR (~5.0 kw) models Indicates main products to target

Product Development

Lab Modifications Safety Protection Multi-point sensing gas detectors to cover all parts of test chamber, with alarm levels and appropriate actions initiated at each level Auto Exhaust System Ventilation dimensioned to bring gas concentration below low alarm level within 10 min Electrical Equipment Ex-proof lighting, blowers, switches Static Electricity Prevention Proper equipment earthing, rubber seals for doors Fire Emergency Devices Auto water spray (mist head device), CO2 fire extinguishers Security Identification Warning markings, Safety procedures on lab doors

Product Research Test methodology Published data on performance of HC-290 vis-à-vis HCFC-22 Drop-in performance* 3~15% drop in cooling capacity 2~8% improvement in COP Charge quantity 45~50% by weight The strategy Drop-in testing Use standard HCFC-22 compressor with 5~10% higher rated capacity Depending on results, work on other elements of refrigeration system *DevottaS, PadalkarAS, Sane NK. 2005, Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner, Int. J. of Refrig. 28: 594-604.

Product Research Charge limit as per EN 378 m max = 2.5 x LFL 5/4 x h 0 x A 1/2, where m max is the allowable maximum charge in a room in kg; A is the room area in m 2 ; LFL is the lower flammable limit in kg/m 3 ; h 0 is the installation height of the appliance in m. For a typical 5kW split AC unit, m max = 2.5 x 0.038 5/4 x 2.3 x 14 1/2 = 361 g.

Product Research Drop-in Test Results (vis-à-vis HCFC-22) Cooling capacity lower by 6% COP higher by 14% Power consumption lower by 17.8% Charge quantity 50% (by weight) average 575 g. Compressor of 10% higher capacity Cooling capacity higher by 4.3% COP higher by 7% Power consumption lower by 3.5% Charge quantity 51% (by weight) average 585 g. Charge quantity - a matter of concern

Product Research Smaller diameter condenser tubes Trials with 5mm diameter internally grooved Cu tubes (instead of 7mm) Cooling capacity lower by 0.5% COP higher by 21% Power consumption lower by 18% Charge quantity 50% (by weight) average 355g. Availability, an issue Only one manufacturer of 5mm diameter condensers Development shelved

R&D Methodology Micro-channel heat exchangers (brazed aluminium) the game changer Use of 50 channel condensers in conjunction with higher efficiency compressors Cooling capacity lower by 3% COP higher by 16.5% Power consumption lower by 20% Charge quantity 46% (by weight) average 360g. Charge quantity conforms to EN 378 requirements

R&D Methodology The way forward Use of micro-channel condensers with smaller channel sizes Explore availability of condensers with 5mm (or lower) diameter Cu tubes

The Manufacturing Project

The Manufacturing Project Tripartite agreement, Ozone Cell/GIZ/Godrej Dec 2010 to set up a pilot facility Equipment Specifications, Tendering June 2011 Equipment Delivery Dec 2011 Installation & Commissioning Jan ~ March 2012 TuVAudit of Manufacturing Line March 2012 Pilot Production - April 2012

The Manufacturing Project Safety Measures on Manufacturing Line Gas Sensors and Alarm Systems Refrigerant Storage Area Refrigerant Charging system Product Performance Test Chamber Product Repair Area Ex-proof electrical hardware in areas handling refrigerant Product Performance Test Chamber Ventilation System in areas handling refrigerant Refrigerant Charging system Product Performance Test Chamber Product Repair Area

The Manufacturing Project Gas charging station with ventilation ducting & gas alarms

The Manufacturing Project Repair area gas recovery system with ducting & gas alarm interlock Fire proof junction boxes in Refrigerant charging areas

The Manufacturing Project Ventilation system in HC 290 gas charging station and performance test chamber with two speed option & gas alarm mechanism and complete power cutoff interlock

The Manufacturing Project The Products AC Cooling Capacity : 3350W Compressor details : Rotary Power Supply :230/1/50 (V/Phase/Hz) Power Input : 943W EER : 3.55 Star Rating : 5 Star AC Cooling Capacity : 3375W Compressor details : Rotary Power Supply : 230/1/50 (V/Phase/Hz) Power Input : 912W EER : 3.7 Star Rating : 5 Star More than 80,000 units manufactured and sold to-date

The Manufacturing Project The Products AC Cooling Capacity : 4900W Compressor details : Rotary Power Supply :230/1/50 (V/Phase/Hz) Power Input : 1380W EER : 3.55 Star Rating : 5 Star AC Cooling Capacity :5000W Compressor details : Rotary Power Supply :230/1/50 (V/Phase/Hz) Power Input : 1350W EER : 3.7 Star Rating : 5 Star More than 80,000 units manufactured and sold to-date

The Manufacturing Project Risk Analysis & Mitigation Leak simulation testing* Under a catastrophic, instantaneous leak situation, between 65% - 75% of the refrigerant exits the system In off-mode, when using a gas detector inside the IDU (set at 20% of LFL) to indicate a leak and initiate IDU airflow, the floor concentration did not exceed 70% of LFL (charge equivalent to 40% of LFL; 450 g in a 30 m 3 room) Use of solenoid shut-off valves in the liquid line (and where necessary, in the suction line) can further reduce the leakage to around 20% of the charge quantity. * Studies conducted by Dr. Daniel Colbourne and Rolf Huehren, GIZ consultants, and Godrej R&D - Test Report on Leak Simulation Tests From HC 290 Air Conditioner, 2012

The Manufacturing Project Leak Detection & Mitigation Refrigerant Leak Detection System Issues a visible and audible alarm under the simultaneous existence of the following condition: Machine current and sensed temperature are less than a determined value. The device must remain active after the initial activation till the device is reset. Upon issuing an alarm, the device must: Override the signal from the machine controller and switch OFF the compressor and Override the signal from the machine controller and operate the blower on the IDU and fan on the ODU at maximum speed.

The Manufacturing Project Leak Detection & Mitigation Refrigerant Leak Mitigation System Solenoid shut-off valves in the event of the start of a release, a shut off valve in the liquid or delivery line and where necessary in the suction line can close in order to prevent flow of refrigerant from the high side of the system to the leak hole; During off-mode the valve(s) could be normally-closed so that the refrigerant is automatically prevented from flowing towards the leak.

Service Training & Network

Service Training Godrej -the only Appliance company in the industry appointed by the Government of India to carry out Training for their projects like NCCOPP, HIDECOR. Godrej Vocational Training School imparts training in training institutes (ITI s) Godrej Refrigerators with HC refrigerants are produced since 2001, 13 years of manufacturing. More than 10 million units installed and serviced by Godrej trained field engineers successfully. Godrej Appliance Service has also trained field staff in Bangladesh.

Service Training All master technicians trained by a team of GIZ and Godrej experts Dissemination of this knowledge to all Godrej technicians Comprehensive training manual prepared Only certified technicians are permitted to install and service the HC 290 AC For Split ACs, flaring of connecting pipe ends not permitted in the field Only Factory flared connections used

Awards & Accolades R&D INDIA DESIGN MARK 2014-15 -for Range of Godrej Green balance Split AC India Design Mark is the highest design recognition from the Indian Government through India Design Council -a design standard, a symbol, which signifies design quality. This symbolizes excellence in form, function, quality, safety, sustainability and innovation. Adds trust and assurance to brand Marks credibility to quality and excellence Split AC awarded recognition due to:- - its remarkable & best energy efficiency value, - its classy aesthetics enhancing space quality of the room. - and its contribution to environment through zero ODP.

Awards & Accolades - Brand Most Trusted Brand Gold from Reader s Digest for 7 th time in 8 yrs Voice of Customer Award for Best Brand Direct Cool Refrigerators Silver Emviesfor the Best Media Strategy for its One Watt Project Consumer & Industry Super Brand 2013-14 Asia s Most Promising Brand in Consumer Durables by World Consulting & Research Corp (WCRC) & ibrand 360

Final remarks Alternatives to HCFC-22 in ACs Concern over suitable options for high ambient regions R-410A normally considered to be unsuitable Other alternatives include HC-290 Normally efficiency in ACs is particularly good and flammability risk is known to be negligible Data on performance at high ambient is very sparse Current work presents results of testing HC-290 and HCFC-22 split ACs at high ambient Variation in COP at high temperature for HC-290 same as with HCFC-22 Variation in capacity of HC-290 same as with HCFC-22 Consistent with the theoretical calculations, but marginally better results observed Evident that HC-290 is well suited to high ambient regions

Final remarks So far over 80,000 HC-290 split ACs introduced Service history, feedback, quality database and safety analysis implies high success General, use of HCs Impose new responsibilities on manufacturers for safe production practices Requires additions and changes to the existing production processes Products must be designed for safety, capacity and efficiency Infrastructure must be established to ensure safe environment Re-training of technicians must be concurrent with development processes Compared to competing products, HC-290 has lower TEWI, low-to medium cost (per kw) and higher efficiency Benefits of shifting to HC 290 must be adequately highlighted to the end consumer Activities are ongoing to expand the range of products Developments include designs for greater integrated safety to further reduce the flammability risk