Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot. Standard Patterns " "

Similar documents
Linea 2.5. Linear Indirect LED

Linea 2.5. Linear Direct/Indirect LED

Linea 3.5. Linear Direct/Indirect LED

Grüv Flare Regressed. Recessed Linear LED

Linea 1.5. Linear Direct Wall Wash LED

Grüv Flare Regressed. Recessed Linear LED

Linea 1.5. Linear Direct/Indirect LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Fino. Asymmetric Wall Mount Indirect LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Lens Wall Wash

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Performance Chart Electrical Data

Performance Chart Electrical Data

Classix 6" 6" Round Lens Wall Wash

Etch 2' x 2' Recessed LED

Performance Chart Electrical Data

Evoke 2.9" HP. 2.9" Square Downlight

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Hornet HP. Round Glass Downlight

Hornet HP. Square Glass Downlight

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Downlight

Murro HP. 3.5" Round Surface Canopy Wall Wash

Velato. Recessed Slot Adjustable Multiples

Classix 6" 6" Round Adjustable C3M

Classix 6" 6" Round Adjustable C3

Classix 6" 6" Round Lens Downlight

Evoke Square Adjustable C3M

Evoke Square Downlight

Evoke Square Adjustable HP

Performance Chart Electrical Data

Hornet HP. Recessed 4-Light Square Multiple

Performance Chart Electrical Data

Evoke Square Adjustable HP

Hornet HP. Semi-Recessed 4-Light Square Multiple

Evoke Round Adjustable C3

Essenza. Square Downlights

Evoke Round Downlight

Essenza. Round Downlights

Classix 6" 6" Round Adjustable C3

Classix 6" 6" Round Downlight

Performance Chart Electrical Data

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

HORNET-HP-R- A14-3 3LT LED

Cylindrix III Mini. 3.5" Round Surface Canopy

RECESSED Spec Guide. up to 111 lm/w performance

VESICA LINEAR SUSPENDED VES L

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

SURFACE Spec Guide. up to 105 lm/w performance

LUX PENDANT DIRECT/INDIRECT

RECESSED T-Bar & Drywall

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

FULL BLEED APPLICATION SHOT RENDERING

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

RECESSED - WITH StepLens OPTION

LIGHT CHANNEL 45 COMPLETE FIXTURE

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

LIGHT CHANNEL TRIM 1.6

WARRANTY LED ECO PANEL.

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

NOVA CEILING WALL GRAZER WITH REMOTE POWER

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

DHL-LP-LED Low Profile LED Linear High/Low Bay

Recessed LED Wall/Slot SAE 202

OLS-DI-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL SUSPENDED LINEAR DIRECT/INDIRECT SYSTEM

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

Ordering Information: 4-ASI5-LED-WDM-35K-18K-4000L-MVOLT ASI5-LED

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Claude Indirect Wall WALL

M100 LED Direct/Indirect

LED ECO PANEL.

Truss Surface SURFACE

M60 LED Recessed Wet Location

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

3.75 Gyro Shift Multiples Single Head

DIMMING 0-10V Continuous

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

Project Name. Date. Cat. Number. Type

TROFFER RETROFIT KIT (TRK)

SDL4 LED Strip Diffused Lens

LED Lighting Product Guide. Spring A portfolio of industry-leading solutions that are changing the way we look at light.

BAS SDL8' LED Strip Diffused Lens

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

OLS-R-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL RECESSED LINEAR DIRECT SYSTEM 2" 4"

BeveLED Cylinder LBRP6 Surface

Max 4 Flush Lens RECESSED

Transcription:

a 2.5 Features a 2.5" drives your design scenario, seamlessly. Streamlined and flexible, these architectural LED pendants provide the freedom to create truly dynamic spaces. synthesis of aesthetics, performance and energy efficiency, the a family delivers on its promises. a 2.5" complements our Gruv 2.5" products Product Overview Type: Cable Suspended, Wall or Surface Direct Wattage: 5W/ft, 10W/ft (other wattages available see p2) Lumen Output: 3,873 max; 93.2 Lm/W (10W, 4ft fixture) Color Temp: 2700K, 3000K, 3500K, 4000K CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) Dimming: 0-10V, 1% dim (standard) Lutron Hi-lume 3 wire, 1% dim Lutron Hi-lume EcoSystem, 1% dim Lutron Hi-lume 2 wire (120V only) Lutron Hi-lume EcoSystem, 1% dim, fade to off Lutron Hi-lume 5 Series DLI dimming, 0.1% dim 5 Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot Delivered Lumens LPW Color Temp 5 2,053 103.2 3000K 10 3,873 93.2 3000K Data is based on 3500K-83 IES files available on website Data is based on 4' fixture with Performance Lens Runs Individual Runs: 2' - 8' (whole foot standard) Continuous Runs: vailable (whole foot standard) Custom: Made to measure available (nearest 1/8" of field dimensions). Requires approval drawings. dded cost & lead time. Electrical Data 4' 8' Wattage Per Foot System Watts mps System Watts mps 5 120V 22.3 0.18 41.9 0.35 277V 22.9 0.09 41.6 0.16 10 120V 42.1 0.35 84.2 0.70 277V 41.5 0.15 83.0 0.30 Electronic multi-volt (120V-277V), constant current LED driver Standard Patterns " " " " Wall to Ceiling Custom* Yes Yes Yes Yes Yes No Yes * Submit drawing, consult factory " " " " " " LIT-2050 10/29/18 Page 1 of 10

Ordering Information LIN2.5D-16 120/277 1 2 3 4 5 6 7 8 9 10 11 1 Model LIN2.5D-16 7 Voltage 120/277 2 3 4 5 Optics PL - performance lens (standard) DL - designer lens Mounting SW10 - through ceiling tile or gyp board, white, 10' SW20 - through ceiling tile or gyp board, white, 20' S10 - through ceiling tile or gyp board, black, 10' S20 - through ceiling tile or gyp board, black, 20' SW10T - over ceiling tee, white, 10' SW20T - over ceiling tee, white, 20' S10T - over ceiling tee, black, 10' S20T - over ceiling tee, black, 20' WM - wall mount SM - surface mount Wattage (per foot) Standard: 5-5W/ft 10-10W/ft Optional: 3-3W/ft (4' minimum length required) 4-4W/ft (4' minimum length required) 6-6W/ft 7-7W/ft 8-8W/ft 9-9W/ft Color Temp 83 CRI: 27-2700K-83 30-3000K-83 35-3500K-83 40-4000K-83 92 CRI optional, consult factory 8 9 10 Length x x (Length ) (Length ) (Length C) Length (used for) Length (used for) Length C (used for) - all patterns - all patterns - PU - IND - PR - 2 lengths - PZ - CON of 2 - CUS Configuration IND 1 - individual fixture, 2' to 8' in 1' increments CON - continuous run > than 8', specify to nearest foot CUS - custom made to measure, +/- 1/8" of customer supplied field dimensions Standard Patterns (see page 6 for details): PLL - L left, (2) straights + (1) 90 corner, leg right PLR - L right, (2) straights + (1) 90 corner, leg left PU - U shape, (3) straight lengths + (2) 90 corners PR - Rectangle, (4) straight lengths + (4) 90 corners PZ - Z shape, (3) straight lengths + (2) 90 corners Custom Patterns: PC - please provide drawings and consult factory Drivers 0-10V - 1% electronic dimming, multi-volt (120V-277V) constant current driver (standard). HILUME--DH - Lutron "" Series, 1% dim, 3-wire (Dim Hot) HILUME--ECO - Lutron "" Series, 1% dim, EcoSystem HILUME--LTE - Lutron "" Series, 1% dim, 2-wire, 120V only HILUME-H-ECO - Lutron "H" Series, 1% dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DLI - DLI Dimming 120V-277V, 0.1% dim 6 Finish HW - high reflectance matte white T - black texture ST - silver texture For other RL color, consult factory 11 Options/ccessories ENLS - Enlighted Sensor (0-10V driver only and not available on 2' & 3' lengths) EMC-PF 2 - emergency circuit requires power feed located in last fixture section (for other locations consult factory) PF 2 - Extra power feed for additional circuiting 1 - Lengths less than 4' may have restrictions based upon wattage, lengths, drivers or other options. 2 - Not available with IND (individual) configuration. The "" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your merlux representative for explanations of changes. LIT-2050 10/29/18 Page 2 of 10

Specifications pplication Open office plan, conference rooms, corridors or any indoor space where the higher light levels of a direct ambient lighting system are required. Construction One piece extruded aluminum housing. Die-cast End Plates match fixture body finish. Die-formed, cold-rolled steel internal components are protected against rust and corrosion. Optical ll lenses are snap-in, extruded acrylic, with a maximum length of 8. merlux's proprietary acrylic lens provide excellent transmission while effectively concealing source image. PL - Performance Lens provides high efficiency with controlled lens surface brightness (standard). DL - Designer Lens provides flat even glow on lens. est when lens is in direct view. LED merlux's boards and patented connector design with brand name LEDs enables merlux fixtures to have excellent thermal management and offer a 5 year warranty. Our LED binning is within 3 Macdam ellipse. oards are configured for maximum flexibility resulting in even illumination no matter the fixture layout. LED boards are easily replaced in the field with just a Phillips screw driver. Color Temperature Options: 2700K, 3000K, 3500K, 4000K CRI: 83 typical, 92 optional - consult factory R9: 16 @ CRI 83 R9: >50 @ CRI 92 Life: 50,000+ hr., > 70% of initial lumens (L70) Electrical Wiring: Individual and "eginning of Run" (OR) fixtures are prewired with power cord. ll configurations have quick connect power harnesses for row connections. Standard Wattage: 5W/ft, 10W/ft. Optional Wattages: 3W/ft, 4W/ft, 6W/ft, 7W/ft, 8W/ft, 9W/ft. (3W & 4W have a minimum length of 4'). For other wattages consult factory. Emergency circuit via remote inverter or auxiliary emergency power supply (by others). This product complies with IEEE C62.41 for surge endurance up to 2.5KV. merlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. EMC-PF - Emergency circuit requires power feed to be located in last fixture section for continuous runs. For other locations consult factory. Not available for individual (IND) configuration. PF - Extra power feed for additional circuiting. Not available for individual (IND) configuration. Drivers 0-10V - 1% electronic dimming, multi-volt (120V-277V) constant current driver (standard). Cap leads for non-dim applications. Optional Drivers: HILUME--DH - Lutron "" Series, 1% dim, 3-wire (Dim Hot) HILUME--ECO - Lutron "" Series, 1% dim, EcoSystem HILUME--LTE - Lutron "" Series, 1% dim, 2-wire, 120V only HILUME-H-ECO - Lutron "H" Series, 1% dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DLI - DLI Dimming 120V-277V, 0.1% dim Finish ll painted surfaces are premium powder coated baked on for maximum durability and color stability. HW - High reflective matte White T - Texture ST - Silver Texture For special paint colors supply RL and/or actual paint chip for factory consultation. Configurations/Lengths IND - Individual fixtures are made of single standard lengths of 2 ft to 8 ft (in 1' increments). These are stand alone fixtures with matching End Caps, supplied with the mounting hardware. Lengths less than 4' may have restrictions based upon wattage, lengths, drivers or other options. CON - Continuous runs, > 8', specified to nearest whole foot length in 1' increments. Runs made from standard lengths have End Caps at the beginning and end of run. Runs > 60' may require second power feed. Each Housing has factory installed alignment pins. Mating fixtures are easily aligned and joined. Wiring is made fast and positive with molded quick connectors. CUS - Custom made to measure runs are made to nearest 1/8"of customer supplied field measurements or drawings. Custom lengths use the same hardware for hairline joining. PXX- Standard Patterns consist of 90º corners with standard lengths (4' to 8' in 1' increments), continuous runs or made to measure lengths. Depending upon complexity of the pattern drawings may be required from the Customer. If ordering please give overall lengths. '-'-PLL - L Left - (1) 90º Corner 2 segments. Specify overall segments: & '-'-PLR - L Right - (1) 90º Corner 2 segments. Specify overall segments: & '-'-PR - Rectangle - (4) 90º Corners joining 4 segments. Specify overall segments: & '-'-C'-PU - U shape - (2) 90º Corners joining 3 segments. Specify overall segments:,, & C '-'-C'-PZ - Z shape - (2) 90º Corners joining 3 segments. Specify overall segments:,, & C See page 6 for layouts. PC - Custom Patterns may use standard lengths, Made To Measure, 90º or other corners (some limitations). Please provide drawing and consult factory. Mounting The a 2.5 Direct is intended to be pendant, wall, or surface mounted in continuous rows. Standard or custom patterns available. LIN2.5D-16...SW10 - Direct pendant installed in center of ceiling tile or gypsum board ceiling, (standard) i.e. SW10. Or if canopy is installed on a grid Tee runner add, T i.e. SW10T Cable Suspension: Cable is stranded stainless steel wire. ll fittings are protected against rust and corrosion. Canopies are 5" x 1/4" die formed painted steel. djustment mechanism allows for infinite height adjustment. merlux recommends the required feed and non-feed suspensions based upon length and electrical options. Options include: color of canopy and power cord (black or white), length 10' or 20', and mounting condition, in center of ceiling tile and in gypsum board ceiling (standard) i.e. SW10. Or if canopy is installed on a grid Tee runner add, T i.e. SW10T LIN2.5D-16...WM - Direct Wall Mount using steel cleat bracket attached to fixture housing and wall bracket with set screws. Two bracket assemblies are used for each length under 8'. third center bracket may be recommended. J box required at feed locations.. LIN2.5D-16...SM - Direct Surface Mounted - Housing needs to be attached to solid structure above. Mounting holes are pre-drilled at factory. Some fixture disassembly and reassembly required. Mounting hardware by others. Certifications pproved to UL standards for damp locations as tested by CS Intended for indoor use only Warranty merlux's 5 year limited warranty. Please consult merlux website for details. LIT-2050 10/29/18 Page 3 of 10

LINE 2.5" DIRECT 1/2" 1 1 /8" Power Feed Suspension Kit Feed location 3 1 /2" 2 11 /16" 3/32" Overall length of run LINE 2.5" DIRECT WLL MOUNT 6" Mounting O. C. Feed location 3 1 /2" 1/2" 2 11 /16" 3 3 /16" 3/32" Overall length of run LINE 2.5" DIRECT SURFCE MOUNT Mounting Screws by others 3" 6" from end of fixture (2 per fixture) ccess Plate w/2ko Mounting location 3 1 /2" 2 11 /16" 3/32" Overall length of run LIT-2050 10/29/18 Page 4 of 10

CLE KIT SUSPENSION OPTIONS: CEILING OR GYPSUM ORD (SW10, SW20, S10, S20) 1/4"-20 x 3/4" L Philips Flat Head Screw FEED J-ox secured to structure above by others Countersunk 1/4"-20 Gem ar Strain Relief ushing N0N-FEED 1/4"-20 rod or wire secured to structure above (by others) Cat# Length Cord/Canopy pplication SW10 10' white/white ceiling tile/gypsum SW20 20' white/white ceiling tile/gypsum S10 10' black/black ceiling tile/gypsum S20 20' black/black ceiling tile/gypsum SW10T 10' white/white ceiling tee SW20T 20' white/white ceiling tee S10T 10' black/black ceiling tee S20T 20' black/black ceiling tee 5" Canopy Power Cord 5" Canopy Two piece Cable Coupler Cable Tie (1 per foot) 1/16" Cable Gripper/Locknut (size will vary) TEE GRID OR SCREW SLOT (SW10T, SW20T, S10T, S20T) FEED Drop Ceiling J-ox (supplied) Drop Ceiling T-ar by others (for Drop Ceiling application) NON-FEED Drop Ceiling T-ar by others IDS Clip with 1/4"-20 Stud by others 5" Canopy LIT-2050 10/29/18 Page 5 of 10

OPTIONL ENLIGHTED SENSOR: merlux and Enlighted have partnered to create building environments that are safer, and smarter, than ever before. t the heart of our partnership is Enlighted's Smart Sensor, the most advanced digital sensor available today. Integrated into merlux products, the sensor seamlessly collects and communicates dense data on building security, occupancy, performance, environmental conditions, ambient light levels, temperature, and energy consumption. This intelligence provides building managers with unprecedented guidance on cost savings and site-planning efficiencies. Enlighted Sensor (ENLS) is available with 0-10V driver only. Minimum run length is 4'. Enlighted power pack is provided with ENLS option. 4 FT OR 8 FT RUNS Optional Enlighted Sensor 8 8 LINE 2.5" PTTERNS: Standard Patterns ll corners are standard 90, standard length legs. Use standard lengths: 4' min to 8' in 1 foot increments. Continuous runs must be the same length in pairs for closed configuration. Custom Patterns Please provide drawings of your configuration. Made to Measure: +/- 1/8", consult factory. PC - custom pattern, please provide drawings and consult factory 7 1 /4" 90 7 1 /4" a 2.5 Lens Mitered Lens PLL PLR Feed Feed Feed PLL - L Left, (2) straights + (1) 90 corner, leg right PLR - L Right, (2) straights + (1) 90 corner, leg left Provide overall lengths: ' & ' Nomenclature: --PLL --PLR PR - Closed Rectangle, (4) straight lengths + (4) 90 corners Provide overall lengths: ' & ' Nomenclature: --PR C C Feed Feed PU - Open U, (3) straight lengths + (2) 90 corners Provide overall lengths: ', ' & C' Nomenclature: --C-PU PZ - Open Z, (3) straight lengths + (2) 90 corners Provide overall lengths: ', ' & C' Nomenclature: --C-PZ LIT-2050 10/29/18 Page 6 of 10

FIXTURE DT: (Complete photometric data (.ies format) available upon request) MULTIPLYING FCTORS: (Multiplying Factor is based on 3000K-83 120V IES file on website) Wattage: 3W 4W 5W 6W 7W 8W 9W CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.63 0.82 1.0 1.17 1.34 1.50 1.64 Factor: 0.93 1.0 1.08 1.15 LINE 2.5 DIRECT PERFORMNCE LENS 5W 3000K 4FT LINE 2.5 DIRECT PERFORMNCE LENS 10W 3000K 4FT Total Watts: 20 Total Watts: 42 Total Lumens: 2,053 Total Lumens: 3,873 Source: 128 White LED's Source: 128 White LED's LTL# 1238330 LTL# 1238331 90 90 225 75 500 75 450 60 60 1000 675 45 1500 45 900 0 15 30 0 15 30 ZONL LUMEN SUMMRY 0-5 21.4 1.0 5-10 63.2 3.1 10-15 101.7 5.0 15-20 134.9 6.6 20-25 161.1 7.8 25-30 179.9 8.8 30-35 190.0 9.3 35-40 191.5 9.3 40-45 185.5 9.0 45-50 173.8 8.5 50-55 157.2 7.7 55-60 137.2 6.7 60-65 115.1 5.6 65-70 92.0 4.5 70-75 68.7 3.3 75-80 46.2 2.3 80-85 25.7 1.3 85-90 7.7 0.4 ZONL LUMEN SUMMRY 0-5 40.3 1.0 5-10 118.8 3.1 10-15 191.3 4.9 15-20 254.0 6.6 20-25 303.6 7.8 25-30 338.2 8.7 30-35 357.0 9.2 35-40 360.1 9.3 40-45 349.3 9.0 45-50 327.5 8.5 50-55 297.4 7.7 55-60 260.1 6.7 60-65 218.2 5.6 65-70 174.4 4.5 70-75 130.3 3.4 75-80 87.9 2.3 80-85 49.1 1.3 85-90 15.0 0.4 0-40 1044 50.8 0-60 1697 82.7 0-90 2053 100.0 90-180 0 0.0 0-40 1963 50.7 0-60 3198 82.6 0-90 3873 100.0 90-180 0 0.0 Efficacy (lumens/watt) = 103.2 lpw Efficacy (lumens/watt) = 93.2 lpw COEFFICIENTS OF UTILIZTION RC 80 RW 70 50 30 10 RCR (expressed as lumens delivered to the task surface) 0 2443 2443 2443 2443 1 2246 2154 2071 1997 2 2056 1896 1763 1652 3 1884 1679 1520 1393 4 1734 1499 1327 1196 5 1601 1348 1171 1041 6 1484 1221 1044 918 7 1380 1112 939 818 8 1288 1019 851 735 9 1206 939 776 666 10 1133 870 712 607 COEFFICIENTS OF UTILIZTION RC 80 RW 70 50 30 10 RCR (expressed as lumens delivered to the task surface) 0 4610 4610 4610 4610 1 4237 4062 3906 3765 2 3877 3574 3324 3114 3 3553 3165 2865 2625 4 3269 2825 2500 2252 5 3018 2541 2207 1961 6 2797 2300 1967 1728 7 2601 2096 1769 1539 8 2428 1921 1602 1383 9 2273 1770 1461 1253 10 2136 1639 1341 1143 LIT-2050 10/29/18 Page 7 of 10

FIXTURE DT: (Complete photometric data (.ies format) available upon request) MULTIPLYING FCTORS: (Multiplying Factor is based on 3000K-83 120V IES file on website) Wattage: 3W 4W 5W 6W 7W 8W 9W CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.63 0.82 1.0 1.17 1.34 1.50 1.64 Factor: 0.87 0.93 1.0 1.08 LINE 2.5 DIRECT DESIGNER LENS 5W 3500K 4FT Total Watts: 20 Total Lumens: 1,487 Source: 128 White LED's LINE 2.5 DIRECT DESIGNER LENS 10W 3500K 4FT Total Watts: 40 Total Lumens: 2,739 Source: 128 White LED's LTL# 11665872.05 LTL# 11665872.06 90 90 125 75 250 75 250 60 500 60 375 45 750 45 500 0 15 30 ZONL LUMEN SUMMRY 0-40 656 44.1 0-60 1157 77.8 0-90 1487 100.0 90-180 0 0.0 Luminaire Efficacy = 75.0 lm/w COEFFICIENTS OF UTILIZTION RC 80 RW 70 50 30 10 RCR 0 1729 1729 1729 1729 1 1572 1505 1446 1391 2 1424 1310 1215 1133 3 1296 1150 1035 942 4 1185 1019 895 799 5 1090 910 783 688 6 1006 820 693 600 7 934 744 619 530 8 870 680 558 473 9 813 624 506 426 10 763 577 463 386 Note: Values expressed as Lumens delivered to the task surface. 1000 0 15 30 ZONL LUMEN SUMMRY 0-40 1211 44.2 0-60 2133 77.9 0-90 2739 100.0 90-180 0 0.0 Luminaire Efficacy = 68.7 lm/w COEFFICIENTS OF UTILIZTION RC 80 RW 70 50 30 10 RCR 0 3185 3185 3185 3185 1 2895 2774 2664 2564 2 2624 2414 2239 2089 3 2388 2119 1908 1738 4 2184 1877 1649 1473 5 2008 1678 1444 1268 6 1854 1512 1278 1107 7 1720 1372 1142 978 8 1603 1253 1029 873 9 1499 1151 934 785 10 1406 1063 853 712 Note: Values expressed as Lumens delivered to the task surface. LIT-2050 10/29/18 Page 8 of 10

DIMMING COMPTIILITY: merlux a fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. merlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMTION ELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FCTORY --- 0-10V - DIMMING (Standard) Integrates into a variety of building management and daylighting controls 0-10V Wiring Diagram 120V or 277V* Dims down to 1% light output Requires interface to turn off power to driver Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Compatible Dimmers : Wall ox Lutron: Wattstopper: Leviton: Diva - DVSTV DF-120277 Renoir II Maestro - MS-Z101 Nova-T - NTSTV-DV Center System Lutron Grafixk Eye with GRX-TV1 Interface 0-10V Dimming Control Gray Purple White Green Driver 0-10V (-) 0-10V (+) Switched Hot V+ V- Red LUTRON HI-LUME DIMMING Integrates into Lutron EcoSystem building management 120V or 277V* Dims down to less than 5% light output May use 3-Wire or EcoSystem Control Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Compatible Dimmers : Wall ox (3-Wire Dimming) Lutron: Diva Maestro Nova-T Vareo Center System Lutron EcoSystem compatible controls HILUME--DH 3-Wire Wiring Diagram Cap unused ECOSYS wires 3-Wire Phase Dimming Control Purple Stripe Purple Orange White Green E1 E2 Driver Dimmed Hot Switched Hot HILUME--ECO, HILUME-H-ECO, HILUME-5-ECO EcoSystem Digital Control Wiring Diagram E2 E1 ECOSYS us EcoSystem Dimming Purple Stripe E1 Driver Control Purple E2 (Cap off Orange wire) Orange Dimmed Hot White Green Switched Hot V+ Red V- V+ V- Red * Driver is 277V dimmable with appropriate dimmer (by others). ll provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. The absence of a dimmer from the lists above does not imply incompatibility. Please consult factory for compatibility inquiries. LIT-2050 10/29/18 Page 9 of 10

DIMMING COMPTIILITY: merlux a fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. merlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMTION ELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FCTORY --- LUTRON HILUME--LTE DIMMING Utilizes Standard incandescent dimmers that are in wide use in installations across the US. est for retrofit applications where TRIC dimmers are installed. 120V only Dims down to less than 1% light output (most cases) Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Must meet dimmer Minimum Load Requirements per dimming manufacturer Compatible Dimmers : Wall ox (Incandescent Style, Wattage as required) Lutron: Diva Maestro Nova-T Vareo Skylark Center System Lutron "GP" Panel Lutron Grafik Eye QS Lutron HILUME--LTE Wiring Diagram TRIC Dimming Control White Green Driver V+ V- Red DLI - DLI DIMMING 120V-277V Digital control protocol allows individual fixture control DLI Wiring Diagram 120V - 277V* Dims down to 0.1% light output in most cases DLI Dimming Control Purple Purple/WT DLI us Driver V+ Red Compatible Dimmers : Wall ox Leviton CD250 Controller White Green V- Center System Dynalite Fifth Light * Driver is 277V dimmable with appropriate dimmer (by others). ll provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. The absence of a dimmer from the lists above does not imply incompatibility. Please consult factory for compatibility inquiries. LIT-2050 10/29/18 Page 10 of 10