GX-20/FM-200 Fire Extinguishing System

Similar documents
KD Innovative extinguishing with Novec TM 1230 by 3M TM

FIRE SUPPRESSION SYSTEM

BOC FS125 The Fire Extinguishing Solution

CARBON DIOXIDE CO 2 Industrial fire suppression systems

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

Fire suppression systems for server rooms and data centres

Safe, Effective, Environment-friendly

CO2 COCO GAS FLOODING SYSTEM

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

Superior by Design The Kidde ADS TM FM-200 System

HART XL High Sensitivity Smoke Detection

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

HART XL High Sensitivity Smoke Detection

Welcome to Argonite fire protection from Ginge-Kerr

An Overview of Extinguishing Systems for Computer Equipment

WATER MIST CONVENTION AND EXHIBITION

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

SAFETY THE BEST FOR YOUR EQUIPMENT

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Certificate of Conformity Certificate num. Registration date Version Valid until

Creating a safer world!

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

Rick Seidel Fike Corporation Regional Sales Manager

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

ODS & SGG Alternatives for the Fire Protection Industry 2018

& Fire Extinguisher Training

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Adequate protection of enclosed facilities

SECTION FM-200 FIRE SUPPRESSION SYSTEM

HFC-227ea FIRE SUPPRESSION SYSTEM

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

SAPPHIRE. Gaseous Fire Suppression Systems. Delivering 3M Novec 1230 Fire Protection Fluid

UEE11 Electrotechnology. Training Package. UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants SAMPLE.

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

How can you minimize consequential damages in case of a fire?

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

How can I protect invaluable assets and the environment from the effects of a fire?

Responsible Care Product Stewardship for Refrigerants

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

3M Novec Fire Protection Fluid

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Hospitals and Major Medical Centers

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

CONSTANT MONITORING OF GASEOUS SYSTEMS

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

Inert Gas Fire Extinguishing System

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

3M Novec 1230 Fire Protection Fluid For Marine Applications. Created. Life. for

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Fire Protection in the Mining Industry. Garry Kwok Board Member

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

SECURITY BLANKET Foam Fire Protection Products

Fire protection for buildings

automatic FiReFighTing SYSTeMS in PainT booths

Certificate of Conformity Certificate num. Registration date Version Valid until

CONTENTS. bawa-speci, Ver Maintenance. 1. INTRODUCTION: 1.1 bawa-speci Version 01

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

FireBeta A-XT UL Approved Extinguishant Control Panel

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Global innovation in fire fighting

The Problem of Counterfeit Refrigerants

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

DETECT-A-FIRE Heat Detectors

The Science Behind Water Mist Protection of Typical Building Hazards

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

THE WORLD LEADER. in special hazard fire suppression solutions

STAT X - SPECIAL HAZARD FIRE PROTECTION

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

Pre-Engineered Fire Suppression

THE TRUE FIRE SURVIVAL CABLE

Natural refrigerants - naturally efficient

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

SPECIFICATION: ARGONITE Engineered Fire Suppression System

MONTREAL PROTOCOL ON SUBSTANCES THAT DEPLETE THE OZONE LAYER UNEP HALONS TECHNICAL OPTIONS COMMITTEE. Technical Note #1 Revision 3

Reflex fire detection and extinguishing system charged with Novec 1230 extinguishing agent. Installation, operation and maintenance instructions

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

Transcription:

GX-20/FM-200 Fire Extinguishing System Halon fire extinguishants were regarded for many years as the most effective fire suppressants for a wide range of applications. Amendments to the Montreal Protocol of 1987 focused on the manufacture of Halons, however, and their production has now ceased in recognition of their virulent destruction of the ozone layer. In addition, new European legislation requires that Halon systems within the EU must be removed by the end of 2003. As a result, recent years have seen a substantial reappraisal of approaches to fire protection. Kidde Fire Protection is at the forefront of new technologies in fire safety, offering a range of state-of-the-art fire extinguishing systems. Kidde Fire Protection offers GX-20 systems containing FM-200, a gaseous agent manufactured by Great Lakes Chemical Corporation, which has emerged as a viable alternative to the Halons on the basis of extensive trials. FM-200 is fast and effective with a low space/weight characteristic which is also environmentally-acceptable and safe for human exposure. FM-200 has been adopted by the majority of the world s fire protection companies and is the most widely used Halon replacement, with tens of thousands of systems installed across the globe. Benefits Fast and effective against a wide range of Class A, B and electrical fires Safe for occupied areas Non-corrosive and electrically nonconductive No post-discharge residue and clean-up Environmentally-acceptable 25 bar system Engineered and pre-engineered systems available Range of system release options Low installation and maintenance costs Computer design maximises effectiveness of system FMRC/LPCB approved components with ULI listed systems available on request Marine systems available

2 Asset protection It is a chilling statistic that of companies suffering an accidental fire event, 43% never re-open and a further 29% close within three years. Ensure that your business is adequately protected and does not yield to this fate. The environment FM-200 has a zero ozone-depletion potential and a short atmospheric lifetime. When used in a fire event, FM-200 mitigates the effects of an uncontrolled fire and at the end of the lifetime of the system, the gas can be readily recovered and recycled. Pressure Operated Control Head What is FM-200? FM-200 is a colourless, odourless gas containing only carbon, hydrogen and fluorine, thereby lacking the ozonedepleting presence of bromine atoms. Highly penetrative and achieving an homogeneous dispersion in the hazard zone, it acts on fires largely by physical means, lowering the temperature of the flame and fuel to a point at which combustion reactions cannot be sustained. There is no significant obscuration on discharge and this non-corrosive and electrically non-conductive agent causes no damage to sensitive equipment with no post-discharge clean-up required. System design The GX-20 range comprises a versatile line of cylinders, valves and related components which have been selected for use with FM-200 and have been subject to stringent testing procedures. Flexibility, quality and reliability make the Kidde Fire Protection GX-20 range the world s finest in fire safety and the equipment carries third party listing through the Factory Mutual Research Corporation and the Loss Prevention Certification Board. Systems are UL1066 compliant. Electric Control Head Electric & Cable Operated Control Head Lever Operated Control Head Lever & Pressure Operated Control Head Electric Control Head (Stackable) Safety to personnel A significant body of toxicity data has been obtained for FM-200 from over 70 studies. The US Environmental Protection Agency and the UK Halon Alternatives Group accepts the use of FM-200 in occupied spaces up to 9% concentration without mandated egress times and at up to 10.5% with mandated evacuation times. Since the agent does not act by oxygendepletion in the hazard zone, it poses no human asphyxiation threat. Both engineered and pre-engineered systems are available. The preengineered systems offer a low engineering/design cost option with defined maximum design parameters. Engineered systems offer optimum designs for the defined risks with reduced pipe sizes, unbalanced flows and common room and void protection possible.

3 GX-20 cylinders A wide range of sizes is available, offering a choice of fill capacities to meet specific requirements and ensure maximum economy in installation. Each cylinder is manufactured from high strength alloy steel The larger cylinders have an optional liquid level device for ease of contents monitoring and improved system maintenance. GX-20 valves GX-20 valves are designed for optimum system performance, reducing pipe sizes and lowering installation costs. The fast-opening valves are available in a range of sizes and are manufactured from tough, corrosion-resistant brass under stringent quality control standards. The valve design enables the Kidde worldwide network of factory-trained distributors to recharge the cylinders without the need for replacement parts. An easy-to-read gauge on the valve permits the convenient visual inspection of the cylinder pressure. GX-20 valves are actuated by one of the following means: Electric solenoid Pneumatic Local manual release at the control head Manual release at a remote pull box All related components from discharge nozzles to control heads are designed to be compatible, allowing a complete system to be configured using FMRC and LPCB approved Kidde Fire Protection equipment. System space requirements System space and weight are usually at a premium in industrial and commercial premises. FM-200 is stored as a liquid in nitrogen-pressurised containers at 25 bar, leading to minimal storage requirements comparing favourably with all other viable gaseous agents. Approvals Kidde FM-200 systems are FM listed, meet the criteria of UL1058A and carry LPCB design manual and component approval. Applications GX-20 systems are ideally suited to the protection of high value assets from both loss by fire damage and the accompanying catastrophic plant down-time. Applications include: Computer suites, EDP facilities and telecommunications hardware Control rooms such as railway signalling centres and air traffic management centres Stores and archives Heritage sites such as art galleries and museums Medical and laboratory equipment Petrochemical plant, offshore oil and gas installations, pipeline pumping stations Ship machinery spaces, rail locomotives and rolling stock Assured reliability Kidde Fire Protection systems are designed to conform to NFPA 2001 and BFPSA Code of Practice requirements. An empirically-verified windows-based computer program is used to model two-phase agent flow and ensure that the correct concentration of agent is achieved within 10 seconds throughout the protected zones as required by the NFPA Standard and BFPSA Code. Nozzles A range of custom-designed nozzles is available including 180 wall-mounted and 360 ceiling-mounted types.

BS EN ISO9001 FM00215 FM-200 is a trademark of Great Lakes Chemical Corporation. Kidde Fire Protection Specification subject to change without notice. E9832-327 03/03 Kidde Fire Protection UK Sales Office Head Office Thame Park Road, Thame, Oxfordshire OX9 3RT, UK. Tel: +44 (0)1844 265003. Fax: +44 (0)1844 256156. E-mail: info@kfp.co.uk Web: www.kfp.co.uk UK Sales Office Unit 12, Atley Way, North Nelson Industrial Estate, Cramlington, Northumberland NE23 1WA UK Tel: +44 (0)1670 713455. Fax: +44 (0)1670 735553 International Offices Dubai: Tel: +971 4 337 2498. Fax: +971 4 337 5088 Hong Kong: Tel: +852 2195 3688. Fax: +852 2743 7477 Singapore: Tel: +65 424 7979. Fax: +65 424 7978 Australia: Tel: +61 3 9765 3850. Fax: +61 3 9765 3800

FM-200 Fire Extinguishing Agent In response to the impending production phase-out of Halon fire extinguishants, Kidde Fire Protection can offer the GX20 System using FM-200 (Heptafluoropropane) as a replacement for Halon 1301 in applications requiring a clean, environmentally acceptable fire extinguishing agent, suitable for use in manned areas. Performance FM-200 extinguishes fires primarily by physical means. It has properties which function well with traditional Halon 1301 equipment. It is a colourless gas at standard conditions, exhibiting a boiling point of -16.4 C as compared to a boiling point of -57.8 C for Halon 1301. Through the use of properly designed equipment, FM-200 will mix well in a protected enclosure to provide a homogenous mixture in air. Since Halon 1301 is typically superpressurised to either 25 bar or 42 bar for fire suppression applications, FM-200 is super-pressurised to achieve rapid discharge into the protected environment. The liquid density of Halon 1301 at 21 C is 1.32 kg/l and for FM-200 is 1.12 kg/l. The characteristic that determines the amount of agent that can be safely stored in a given cylinder is the maximum fill density. Kidde Fire Protection advises that the maximum fill density for a cylinder of FM-200 pressurised with nitrogen to 360 psi is 1.15 g cm-3. Accordingly, the storage capacity for FM-200 is around 1.5 times that of Halon 1301, the closest of all viable replacement agents. Toxicity In determining a safe exposure level to any agent intended for use in occupied spaces, the potential of the agent to cause cardiac sensitisation should be determined. FM-200 has been evaluated for this condition via test protocols approved by the US Environmental Protection Agency, and has been cleared for use in occupied areas at the normal design concentration. Ozone Depletion Potential (ODP) As the concerns over stratospheric ozone protection have developed in recent years, it is clearly understood that any agent that is expected to be available for use in the market on a long term basis would have to offer zero ODP. Since FM-200 contains no chlorine or bromine and does not possess the properties associated with the compounds thought to damage stratospheric ozone it has an ozone depletion potential of zero. Global Warming Potential Biodegradability of chemical compounds in the environment is also a paramount concern. Long-lived

2 Technical specification HALON 1301 FM-200 Chemical Formula CF 3 Br C 3 F 7 H Ozone Depletion Potential 16 0 Molecular Weight 148.9 170.03 Boiling Point -57.8 C -16.4 C Critical Temperature 67.0 C 102.0 C Extinguishing Concentration,Heptane Cup 3.5% 5.8% Burner (% by volume) Inerting Concentration (Explosion Sphere, 4% 8% 70 joules ignition energy) - Methane Vapour Pressure at 21 C 214 psia 68.8 psia Acute Toxicity (LC50-4hr) 800,000 ppm >800,000 ppm Heat Feedback Fuel Volatilisation Heat Dissipation Air Entrainment compounds are thought to pose greater risks of contributing to global warming. Determination of the atmospheric lifetime of FM-200, indicates a lifetime of only 31 to 42 years. This lifetime has been considered as acceptable for fire extinguishing compounds by the US Environmental Protection Agency's Significant New Applications Programme (SNAP). Compatibility FM-200 is a very stable compound and in the absence of excessive moisture is not expected to react with common construction materials such as metals and polymers. Tests show that elastomers such as some EPDM materials and nitrile compounds perform well with FM-200. How FM-200 works In order for a fire to be sustained, the three components fuel, oxygen and heat, must be present in sufficient quantities, and at sufficient levels. If one of the three elements is removed the fire will be suppressed. The theory of combustion Fire is the physical manifestation of a series of high heat-releasing chemical reactions between fuel and oygen. While a proportion of the heat is dissipated to the surroundings, sufficient heat must be returned to the fuel in order for it to vaporise and continue the combustion process. Physically-acting extinguishing agents act by absorbing heat and disturbing this dynamic energy balance. Introduction of sufficient agent into the fire gases reduces the flame temperature to a limiting value below which flame propagation cannot occur. In figure 1 overleaf, the minimum extinguishing concentration (using the n-heptane cup burner test) of various agents is plotted against their heat capacity. FE-13, FM-200, and PFC-410 have progressively higher heat capacities*, consequently their required extinguishing concentrations become progressively lower. Agent Extinguishing Concentration FE-13 13.0% FM-200 5.8% PFC-410 5.5% Halon 1301 3.0%

3 Halon 1301 is a more efficient extinguishant despite having poorer heat absorbing qualities than FM-200. Figure 1: Extinguishing concentration v heat capacity This is because in addition to the heat absorption effect, the bromine in Halon 1301 catalyses removal (through recombination) of the flame propagating radicals and so suppresses the fire by chemical means. 100 ext. concn. (vol%) Ar, Ne FE-13 N 2 CO 2 FM-200 It is the bromine in Halon 1301 which causes depletion of the Ozone Layer and has led to Halons being phased out under the Montreal Protocol. 10 PFC-410 Although PFC-410 is slightly more efficient than FM-200, it has a higher global warming potential and is therefore preferred for special applications only. FM-200 works by physical action, the molecules absorb heat so that the temperature of the flame falls to a point below which it cannot propagate, and the fire is extinguished. The oxygen depleting effect is minimal as only small quantities of the gas are used. Inerting gases The inerting gases, such as nitrogen, argon and carbon dioxide, are very poor heat absorbers (refer to figure 1) and high concentrations are needed to suppress fires. Consequently the oxygen concentration in an atmosphere becomes severely depleted, typically around 12%. 1 10 100 1000 heat capacity (J/mol/K) Halons Halon 1301 Atmospheres where the oxygen level is below 16% are considered a potential health hazard. Carbon dioxide is also toxic at concentrations above about 8%. * Heat capacity is the amount of heat energy absorbed by a unit of a compound in raising its temperature by 1 C. Normally it is quoted per g of compound or, as in Figure 1, for a fixed number of molecules (ie per g mol). inerts PFCs HFCs HCFCs heat capacities at 298k heptane cup burner data

BS EN ISO9001 FM00215 FM-200 is a trademark of Great Lakes Chemical Corporation. Kidde Fire Protection Specification subject to change without notice. E9832-008 03/03 Kidde Fire Protection UK Sales Office Head Office Thame Park Road, Thame, Oxfordshire OX9 3RT, UK. Tel: +44 (0)1844 265003. Fax: +44 (0)1844 256156. E-mail: info@kfp.co.uk Web: www.kfp.co.uk UK Sales Office Unit 12, Atley Way, North Nelson Industrial Estate, Cramlington, Northumberland NE23 1WA UK Tel: +44 (0)1670 713455. Fax: +44 (0)1670 735553 International Offices Dubai: Tel: +971 4 337 2498. Fax: +971 4 337 5088 Hong Kong: Tel: +852 2195 3688. Fax: +852 2743 7477 Singapore: Tel: +65 424 7979. Fax: +65 424 7978 Australia: Tel: +61 3 9765 3850. Fax: +61 3 9765 3800