Simulator Intravenous Arm (Two arm and circulation pump set)

Similar documents
SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

M175 Sakamoto Suction Simulator

MIMAKI ENGINEERING CO., LTD.

Operation Manual RANGE HOOD

Combination ultrasonic and heating method of misting. Micro-computer automatically senses air humidity and start operation

Bacti-cinerator Sterilizer

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Aquamax KF Oil Evaporator. User Manual

Mitocell: Instructions for Use

EP-21F Manual Letter Folder Operation Manual

CEILING SPEAKER SYSTEMS F-2352C

Dyna-Form Air. Alternating Pressure Relief Overlay System

Soldering Station. Instruction Manual

CAUTION EXPOSED SHARP OBJECTS INSIDE. HAZARDOUS MOVING PARTS DO NOT OPERATE WITH COVER OPEN. for Block Ice

BAXTER: FACTOR VII 600 IU (Plasma Derived)

Compression therapy device & accessories Model 701A User manual

POLYMIX PX-IG 2000 Operating Instructions

OPERATING INSTRUCTIONS FUSION MODEL 610 DIGITAL DISPENSING SYSTEM

SINGLE PATIENT DIALYSIS MACHINE

CEILING SPEAKER SYSTEM F-122C INSTRUCTION MANUAL TABLE OF CONTENTS 7. REPAINTING THE SPEAKER SAFETY PRECAUTIONS... 2

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

VIVA ace Quick Operation Guide

Requests for Daily Care and Maintenance

Closomat Lima Vita installation & user guide

Instructions. Portable Absorb Phlegm. Apparatus

INTELLIGENT LEAD FREE SOLDERING STATION INSTRUCTION MANUAL V1.0 WARNING

your floor machine. As a shipper, we are unable to act upon any claim for concealed damage. You must originate any claim within 5 days of delivery.

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Dehumidifier. Instruction Manual. Model DH-320/A

Instruction Manual F KSTFD12AAG IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS. For Household Use Only

Far-infrared method Pre-Heater

FAULT FINDING. Water Gas Cassette Toilet FAULT FINDING

MODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)

OGCF2002A User Manual

Troubleshooting your BAXJECT II Needle-less Transfer device

USER MANUAL WATER DISPENSER WITH ICE MAKER

Health Frequency Therapy Device. Instruction Manual

Product waste disposal - Protection of the environment:

Dual Zone Wine Cellar

MODEL 7000 SUCTION UNIT

Soldering Station. Instruction Manual

TP500 / TP500C Heat Therapy System STANDARD (NORME) C22.2 NO 125 RISK CLASS (CATEGORIE DE RISQUES) NO 2G OPERATOR'S MANUAL PIN /98

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

USER MANUAL Model DWP-55/DWP-66

MODEL# GSI180 FRUIT DESSERT MAKER HEALTHY DESSERTS. PHOTO OF PRODUCT

FAVORIT DISHWASHER USER MANUAL

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

NR17/NR20 OWNERS MANUAL

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

CBC II Blood Collection & Reinfusion System. Installation and use in Operating Room

FTA-1 Aspirator with trap flask

Manual. Fazer DFZ-800

HX-30/40 and HX-30/40 S Glass and Dishwashers

USER S INSTRUCTION MANUAL. Save more than 50% of your room heating cost

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

INSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK

O p e r a t i n g I n s t r u c t i o n s

CEILING SPEAKER SYSTEM

CMU701/ 705 OPERATIONS & INSTRUCTION MANUAL

QTFX-LF900 Low-Level Fog Machine User Manual

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

DAIKIN ROOM AIR CONDITIONER. Operation Manual

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

Requests for Care and Maintenance

Series: MBC1-TC Mini Benchtop Temperature Controller

Instruction Manual. Please read these instructions fully before using this product. Smart Living Steam Mop. With all new design enhancements

Manual. Snow machine S-2

Countertop Refrigerator

AMBIENCE Low Air Loss Mattress Replacement System

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Operating Instructions

OPERATING MANUAL SPRAY GUN CLEANERS UG UG3000 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

Instruction Cum User Manual For EUROLITE

E S D REWORK SYSTEM 3 IN 1, I702 USER S GUIDE

COOKER HOOD. AFTER-SALES SERVICE (Including Spare Part Request)

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

The Ionzyme DFII System

BK3300/BK3300L. Intelligent Lead free Soldering Station. Instruction Manual V1.0. Warning

SAVE THESE INSTRUCTIONS

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

Service Manual DIRECTHEALTHCARESERVICES.CO.UK

Operating Instructions

Infrared Portable Space Heater

COVER MODEL# GVS415 VACUUM SEALER FOOD PRESERVER. PHOTO OF PRODUCT

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

Dr. Infrared Heater Elite Series

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

AI-215 Series Portable Ice Maker

SYSTEM Inverter Air Conditioners

OPERATION MANUAL. Air Conditioners FXAQ20PV1 FXAQ25PV1 FXAQ32PV1 FXAQ40PV1 FXAQ50PV1 FXAQ63PV1. MODELS Wall-mounted type. English. Deutsch.

HERCULES (110V) (220V) USER S MANUAL

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Stainless Steel Cup. Instructions. Lunch Cup MODEL. Replacing and purchasing consumable parts. Before contact customer service.

INSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP JDK-60, JDK-80, JDK-100, JDK-120

ELITE (110V) (220V)

Transcription:

M50B-B Simulator Intravenous Arm (Two arm and circulation pump set) Instruction Manual Contents Before You Start Features/DOs and DON'Ts Part names and functions/set includes Before Training Preparation of simulated blood Setting up the circulation pump Training Session Filling the simulated blood Function of changeover switch After Training Discharge the simulated blood Cleaning Dismantle and storage Parts Replacement Replacement of consumables Trouble Shooting P.1,2 P.3 P.4 P.5 P.6 P.7 A life-like simulator for venous blood collection and intravenous injection, this unique device accurately reproduces not only vein location, but also the circulation of human blood - including flash-back confirmation as with an actual patient. The simulator is designed for training of healthcare professionals. Please read the instruction carefully before use.do not use the system in a way other than hereinafter prescribed by the manufacturer.

Before you start Features / DOs and DON'Ts Features Life-like touch and resistance of the injection sites allows vein palpation in the same way with a real patient. Resistance of the soft tissue and veins felt through the injection needle are closely simulated. Circulation pump reproduces human circulation flow. Realistic flash-back of the fluid into the injection needle. Easy replacement of injection pads. No puncture traces of injection needle remains. Life-size arm/hand models with supporting stands. Easy to set up, one-touch connections. Quiet pump. Durable blood vessels. Leakage free and easy clean up DOs Operate the system under the designated circumstances Power input: AC 100V230V plus or minus10%, 50Hz/ 60Hz Temperature range: between 0 degrees C and 40 degrees C (no congelation) Relative humidity; between 0% to 80 % (no condensation) Follow the instruction on labels Warning label indicates there is a danger of an electric shock when the part is opened up. Opening up any lids, caps or covers with warning labels is discouraged. Never run the system while the warning-labeled lids or covers are open. Safe disposition To avoid short circuit, do not run the simulator set above a power receptacle. Handle with care The materials for the models are special compositions of soft resin. Please handle them with utmost care at all times. Storage Store the training set at room temperature, away from heat, moisture and direct sunlight. Storage under the temperature above 50 degrees C may reduce the performance quality of the simulator. DOs and DON'Ts DON'Ts Never wipe the models and pads with thinner or organic solvent. Don t mark on the models with pen or leave any printed materials in contact with their surface. Ink marks on the models won't be removable. Do not give shocks The circulation pump is a precision instrument. Strong shock or continuous vibration may cause breakages of its internal structure. Do not run the pump continuously over 2 hours. Take at least 30 minutes shutdown, turning off the power, every 2 hours.

Before you start Part names and functions/set includes Part names and functions Circulation pump Jar Jar holder Suction/ discharge tube Power switch Rotation changeover switch Tube Pump Power plug Tube Socket (black: male) Tube Socket (white: female) Set Includes Before your first use, ensure that you have all components listed below. c b e d a d a g h c b a. Arm model b. Injection pad (translucent) c. Injection pad (red) d. Supporter stand for Arm 2 2 2 2 e. Circulation pump f. Plastic jar g. Blood (coloring) powder h. Spoon 1 1 1 1

Before Training Preparation of simulated blood Setting up the circulation pump Preparation of simulated blood 1. Take blood powder with the tip of the provided small spoon. 2. Dissolve it in half a jar of water. (approx. 150cc) 3. Place the jar into the jar holder of the circulation pump. Insert the suction/discharge tubes into the simulated blood. Make sure the both tips of tubes are properly placed undersurface of the fluid. Insert PLEASE NOTE The solution is not designed for prolonged storage. Prepare new simulated blood for each session. Setting up the circulation pump Connect: Plug in and turn clockwise. Plug the tips of tubes from an arm/hand unit into the tube sockets at the side of the pump in accordance with colors. Then fix the plugs by turning them clockwise. Connection: Plug in and turn clockwise. Disconnection: Turn the plug counterclockwise and pull it out PLEASE NOTE To avoid leakage, turn off the pump before disengaging the tube connectors. Be sure to hold the plastic plug when pulling. Otherwise the tube may separate from the plug. Plug (Black) Circulation pump Plug (white) Plug (Black) Plug (white) Circulation pump Arm model Connection of plural arm model units Connect the arm models in series. Arm model 1 Arm model 2

Training Session Filling the simulated blood Function of changeover switch Filling the simulated blood 1. Turn the changeover switch to 'NORMAL'. Connect the pump to the power source and switch the power switch on. PLEASE NOTE : When a tube is folded, the fluid does not circulate properly. 3. When the simulated blood in the jar is runs low, please refill the jar. Function of changeover switch 1. Ensure that the change-over switch is set at Normal. 2. Connect the power plug to the power source and turn the power on, then let the fluid fill the tubings. 3. Start training session. Function of changeover switch NORMAL: Fluid circulates CLOCKWISE to produce negative pressure in the vessel tubes. Back Flow: Fluid circulates COUNTER-CLOCKWISE to produce positive pressure in the vessel. PLEASE NOTE Back Flow [BF] function is for flash-back confirmation procedure only. When the flash is seen, turn the change over switch back to Normal before continue. Power switch Rotation changeover switch Do not leave the pump running at [BF] mode too long while training, otherwise it may lead to shorter lifeof the puncture pad or leakage of the fluid.

After Training Discharge the simulated blood Cleaning Dismantle and Storage Discharge the simulated blood Lift 1. Discharge the simulated blood. Lift the tips of the suction/discharge tubes slowly above the surface of the fluid and run the pump. 2. When all the fluid has returns into the jar, stop the pump and discharge the fluid in the jar and fill it with clear water. 3. Set the water filled jar to the pump and run the pump with the both tube-tips under the water. Then, discharge the water by running the pump with the tube-tips above the water. 4. Discharge the water in the jar and dry the pump naturally. Cleaning 1. Wipe the models gently with dry soft cloth and wipe the pump with a wet cloth. CAUTION: Never wipe the models with thinner or organic solvent. Dismantle and Storage 1. Turn the power switch off. 2. Disconnect the tubes.

Parts replacement Replacement of Consumables Replacement of Consumables Remove the used pad Arm model 1. Hold the pad, lift and detach it gently, pulling off the vein tubes. Pull out all tubes. Install a new pad 2. Put the tubes through the openings in the arm model. Then, pulling the tubes gently, place the pad into the hollow. Be careful not to drag the pad by pulling the tubes. Hold the pad by one hand while pulling the tubes by another unit the pad gets set on place. Be careful not to fold the tubes or tack them between the pad and the model.

TROUBLE SHOOTING Quick check-up before calling the customer service. Look in this section for a description of the problem to find a possible solution. TROUBLE SHOOTING Trouble Possible causes Solution Is power plug connected? Plug to the power supply. Circulation pump doesn t run. Is the power switch turned on? Is the power at the power source? Turn it on. Throw a circuit breaker or try other power points. Is the fuse intact? Replace the fuse. Aren t the tubes folded? Lift the pad gently and straighten the tubes. Pump runs but fluid doesn t flow. One or both tips of the suction/discharge tubes are in the air. Put the tube tips in the fluid. Injection pad is worn out and bubbles are in the tube. Replace with a new pad Injection pad gets deformed. Has not any fluid or air been injected outside of the vein tube? Suck out the additional air or fluid by the syringe and dry the pad naturally. The simulated blood heavily leaks from the injection pad. Isn t the changeover switch set at BF position? Injection pad is worn out. Turn it to NORMAL position. Replace with a new pad.

URL:http://www.kyotokagaku.com e-mail:rw-kyoto@kyotokagaku.co.jp Worldwide Inquiries & Ordering Kyotokagaku Head Office and Factories: 15 Kitanekoya-cho, Fushimi-ku, Kyoto, 612-8388, JAPAN Tel: +81-75-605-2510 Fax: +81-75-605-2519 Kyotokagaku America Inc. : USA, Canada, and South America 3109 Lomita Boulevard, Torrance, CA 90505-5108, USA Tel: 1-310-325-8860 Fax: 1-310-325-8867 2016.01