SECTION HEATING AND AIR CONDITIONING PIPING SYSTEMS. A. Provisions of Division 01 apply to this section. 1. Chilled Water System.

Similar documents
VALVES SECTION 15100

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION STEAM CONDENSATE PUMPS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

University of Delaware

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

SECTION SECTION DESIGN REQUIREMENTS

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

TECHNICAL. Series 18. Pump Packages

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SECTION PLUMBING EQUIPMENT

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

SECTION HYDRONIC PIPING AND SPECIALTIES

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Design and Construction Standards SECTION PLUMBING EQUIPMENT

UNDP / PAPP OFFICE BUILDING RAMALLAH HVAC WORKS

B. Shop Drawings: Detail fabrication of pipe anchors, hangers, special pipe support assemblies, alignment guides, expansion joints and loops,

REFRIGERANT PIPING SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

A. This Section includes the following domestic water piping specialties:

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

SECTION PLUMBING EQUIPMENT

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

SECTION METERS AND GAGES FOR PLUMBING PIPING

REFRIGERANT PIPING

OKLAHOMA STATE UNIVERSITY - BUILDING DESIGN STANDARDS

SECTION DOMESTIC WATER PIPING SPECIALTIES

PROJ. NO SECTION REFRIGERANT PIPING

SECTION AUTOMATIC SPRINKLER PIPING

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

PROJECT NAME: DPW Idaho State University Liberal Arts Building Chiller Replacement

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

SECTION FIRE PUMP AND CONTROLS

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

SECTION STEAM CONDENSATE PUMPS

SECTION BASIC MATERIALS AND METHODS

SECTION HYDRONIC PIPING

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

Ratio Architects, Inc. Section Refrigerant Piping

4. Provide brass valve tags marked for the service. See pertinent service specification for valve type.

UNIVERSITY OF MISSOURI Building Hydronic Piping and Pump Systems 2017 Q3

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

1.1 This section applies to air handling units for HVAC Systems.

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

NATURAL GAS PIPING

A. This section includes design and performance information for fire protection and suppression systems.

WET-PIPE SPRINKLER SYSTEMS

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION REFRIGERANT PIPING

Flow Control for Fire Protection

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

SECTION FAN COIL UNITS

FIRE SUPPRESSION SPRINKLER SYSTEM

CONTENTS. A. Summary. Yale University Design Standards. Valves. Change History

SECTION HEATING BOILER FEEDWATER EQUIPMENT

SECTION STEAM CONDENSATE PUMPS

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

DOCUMENT TABLE OF CONTENTS

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 21 FIRE SUPPRESSION

SECTION METERS AND GAGES FOR HVAC PIPING

SPRINKLERS TABLE OF CONTENTS

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION DOMESTIC WATER PUMPS

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Related Sections: The following Sections contain requirements that relate to this Section.

INSTRUCTION AND REPAIR MANUAL

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Transcription:

SECTION 15180 PART 1 - GENERAL 1.01 SUMMARY A. Provisions of Division 01 apply to this section B. Section Includes: Providing complete piping systems for heating, ventilating, and air conditioning systems as indicated. Systems include but are not limited to the following: 1. Chilled Water System. 2. Condenser Water 3. Hot Water Heating System. 4. Low-pressure Steam 5. Miscellaneous Piping Required for Equipment of this Section. 6. Connections to Exterior Utilities. C. Related Sections: 1. Section 02318: Excavating, Backfilling and Compacting for Utilities. 2. Section 15010: Basic Mechanical Requirements. 3. Section 15050: Basic Mechanical Materials and Methods. 4. Section 15070: Mechanical Sound, Vibration and Seismic Control. 5. Section 15075: Mechanical Identification. 6. Section 15080: Mechanical Insulation. 7. Section 15400: Plumbing. 8. Section 15460: Water Treatment Equipment 15180-1

9. Section 15600: Refrigeration Equipment. 10. Section 15900: HVAC Instrumentation and Controls. 1.02 QUALITY ASSURANCE A. Refer to Sections 15050 and 15010. 1.03 SUBMITTALS A. Provide submittals in accordance with Division 01 and Section 15010. B. Manufacturer's Data: Comply with requirements of Section 15050. 1.04 PRODUCT HANDLING A. Comply with requirements of Section 15050. 1.05 COORDINATION A. Coordinate related and adjacent activities in accordance with Section 01100. PART 2 - PRODUCTS 2.01 MATERIALS, EQUIPMENT AND METHODS A. L.P. Steam Systems (Above Ground Piping): 1. Pipe: Schedule 40 seamless black steel, ASTM A 53B, type S. Pipes and fittings shall be properly marked with schedule No., ASTM No. manufacturer, etc. in accordance with ASTM requirements. 2. Fittings: 3. Joints: a. 2 inches and smaller: 150-lb. standard weight, black, malleable iron, threaded. Material conforms to ASTM A 47; threads, ASA B 2.1 malleable iron, threaded; refer to Section 15050. b. 2-1/2 inches and larger: Standard weight, seamless steel; welding fittings and flanges ASTM A 234 and ASA B 16.9 for fittings and ASTM A 181 or A 105 for flanges. 15180-2

a. Threaded: Refer to Section 15050 for pipe joints and connections. b. Welded: Refer to Section 15050 for welded pipe joints. 4. Unions on Piping 2 Inches Diameter and Smaller: 150 lb. malleable iron, ground joint pattern, brass to iron seat, FS W-26-531 or ASTM A 47, grade 32510, black. 5. Flanges on Piping 2-1/2 Inches Diameter and Larger: a. 150 lb. forged steel, weld neck or slip-on, ASTM A 181 and ANSI B 16.5. Furnish flat faced flanges against equipment with flat faced flanges. b. Flange gaskets: Mineral fiber, 1/16 inch thick, equivalent to Garlock No. 900, or equal. c. Bolting materials: Carbon steel heavy hex bolts and nuts, ASTM A 307, type B. B. Chilled Water, Heating Hot Water and Condenser Water (Above Grade Piping): 1. Pipe: a. 2 inches and smaller: Standard weight, seamless copper, type L hard drawn, ASTM B 88. b. 2-1/2 inches and larger: Same as for low-pressure steam. 2. Fittings: 3. Joints: a. 2 inches and smaller: Wrought solder-type copper, in accordance with ANSI B 16.22. b. 2-1/2 inches and larger: Same as for low-pressure steam. a. 2 inches and smaller: 95 percent tin and 5 percent antimony solder with non-acid flux type flux, ASTM B32, grade 95TA. b. 2-1/2 inches and larger: Same as for Low-pressure Steam. 15180-3

4. Unions: a. 2 inches and smaller Wrought solder type, copper to copper; except furnish dielectric unions where copper connects to steel. b. 2-1/2 inches and larger: Same as low-pressure steam. C. Valves: Chilled Water and Condenser Water. 1. Gate Valves, 2 Inches and Smaller: Class 125, body and bonnet ASTM B 62. Cast bronze composition. Threaded or soldered ends. Solid disc, copper-silicon alloy stem, brass packing gland. Threaded ends: Stockham B- 100 (RS) or B103 (NRS), Crane 428 or 438. Hammond IB 640 (RS) or IB 645 (NRS). Soldered ends: Stockham B104 (NRS), B108 (RS), Milwaukee 11.5 (NRS) or 149 (RS). 2. Gate Valves, 2-1/2 Inches and Larger: Class 125 iron body, bronze mounted, ASTM A 126, class B cast iron, flanged ends with Teflon impregnated packing and 2-piece packing glass. Stockham OSY RS NRS G-623 G612 Crane 465 1/2 461 Powell 1793 1787 Hammond IR1140 IR 1138 3. Butterfly Valves: Centerline series A, 150 psi tight shut-off, ASTM A 126. a. Body: Wafer type, iron. b. Disc: Cadmium-plated ductile, iron for chilled water (bronze, or aluminum bronze for condenser water). c. Stem: Solid one-piece, 304 or 316 or 410 stainless steel. d. Seat and O-rings: EPDM O-ring. e. Upper and lower stem bearings: Bronze or reinforced Teflon. f. Operators: 15180-4

(1) Valves 6 inches and smaller: Victaulic No. 700 with lever handle. (2) Valves 8 inches and larger: Victaulic No. 701 manual gear operator and disc position indicator. g. Manufacturers: Milwaukee, Centerline, Stockham, Crane, or DeZurik. 4. Globe Valves 2 Inches and Smaller: Shall be of class 125, body and bonnet of ASTM B 62 cast bronze composition, threaded or solder ends, copper silicon alloy stem, brass packing gland, Teflon-impregnated packing, and malleable handwheel. Threaded (Teflon Disc) Stockham B-BT (Bronze Disc) Solder (Teflon Disc) Stockham B-14T (Bronze Disc) Stockham B-16 Stockham B-17 Crane 108 Crane 1310 Powell 650 Powell 1823 Hammond IB 440 Hammond IB 418 5. Globe Valves 2-1/2 Inches and Larger: Shall be class 125 iron body, bronze mounted with body and bonnet conforming to ASTM A 126, class B cast iron, flanged ends, with Teflon-impregnated packing and 2 piece packing gland assembly. Stockham G-512 (Bronze disc) Stockham G-514T (Teflon disc) Bronze Disc. Comp. Disc. Crane 351 359 Powell 241 301 Hammond IR 116 6. Plug Valves, 2 Inches and Smaller: Rockwell No. 114, lubricated plug type, 200 lb., water operating gage pressure iron body and plug, regular pattern, threaded, with indicating arc. Walworth, Homestead, or WKM. 7. Plug Valves, 2-1/2 Inches and Larger: Rockwell No. 115 and No. 165, lubricated plug type, 200 lb. water operating gage. Iron body and plug, 15180-5

regular pattern, flanged, with indicating arc. Walworth, Homestead, or WKM. 8. Check Valves, 2 Inches and Smaller: Shall be of class 125, threaded or solder ends, body and caps shall be of ASTM B 62 cast bronze composition, swing type disc. Threaded Solder Stockham B319 Stockham B-309 Hammond IB 904 Hammond IB 912 Crane 37 Crane 1707S Powell 578 Powell 1825 Class 150 valves meeting above Specifications may be furnished where pressure requires: Stockham B321, threaded. 9. Check Valves, 2-1/2 Inches and Larger: Shall be iron body, bronze mounted with body and cap conforming to ASTM A 126, class B, cast iron, flanged ends, swing type disc. Hamond IR 1124 Stockham G-931 Crane 373 Powell 559 10. Alternative Check Valves, 2-1/2 Inches and Larger: Shall be class 125/250, iron body, bronze mounted, wafer check valves, with ends designed for flanged type connection, aluminum bronze disc, EPDM seats, 316 stainless steel torsion spring, and hinge pin. Stockham WG-971 Center Line CLC Mission K12 HMP 15180-6

Marlin A125 HZDSF 11. Non-Slam Check Valves (Pump Discharge): Miller No. 162, with semisteel body, bronze trim, top and bottom center guide, stainless steel spring and 125 lb flanged ends. Williams, Hager or Muessco. 12. Air Vents: Crane No. 712 or No. 744, manual type, of size for proper venting. Install at high points of systems. D. Valves: Hot Water Heating and Low-pressure Steam System. 1. Gate Valves, 2 Inches and Smaller: Shall be of class 150 with body and union bonnet of ASTM B 62 cast bronze composition, threaded or solder ends, solid disc, copper-silicon stem, brass packing gland, Teflonimpregnated packing, and malleable handwheel. Threaded Solder Stockham B-120 (RS) Stockham B-124 Stockham B-130 (RS) Hammond IB 629 Hammond IB 648 Crane 431-UB Powell 2714 2. Ball Valves, 2 Inches and Smaller: Shall be 600 psi CWP, have cast brass bodies, replaceable reinforced Teflon seats, conventional port, blowout proof stems, chrome plated brass ball, and threaded or solder ends with extended solder cups. Threaded Stockham S-216-BR-RT Crane 9302 Solder Stockham S-216-BR-RS Crane 2192 H Worcester 4112 RT --- Jamesbury 11 1100TT --- Apollo 70-100 Apollo 70-200 15180-7

3. Gate Valves, 2-1/2 Inches and Larger: Shall be class 125 iron body, bronze mounted, with body and bonnet conforming to ASTM A 126, class B, cast iron, flanged ends, with Teflon-impregnated packing and 2-piece packing gland assembly. OS & Y NRS Stockham G-623 G- 612 Hammond IR 1140 IR 1138 Crane 465 1/2 461 Powell 1793 1787 4. Globe Valves, 2 Inches and Smaller: Shall be of class 150 with body and union bonnet of ASTM B62 bronze, copper-silicon alloy stem, brass packing gland, Teflon-impregnated packing and malleable handwheel. Telflon Disc: Threaded Solder Stockham B-22 B-24 Hammond IB413T IB 423 Threaded Composition Disc: Crane 7 Powell 150 Solder S.S. Trim: Crane 14 1/2 Powell 2600 1823 Class 200 valves meeting the above requirements may be furnished where pressure requires. Stockham B-32 (Teflon disc), or equal. Stockham B-62 (stainless trim), or equal. 15180-8

Hammond IB 434. 5. Globe Valves, 2-1/2 Inches and Larger: Shall be class 125 body, bronze mounted, with body and bonnet conforming to ASTM A 126, class B, cast iron, flanged ends, with Teflon-impregnated packing and 2-piece packing gland assembly. Stockham G-512 (bronze disc). Hammond IR 116. Crane 351. Powell 241. Stockham G-514 (Teflon disc). 6. Check Valves, 2 Inches and Smaller: Shall be class 150 with body and cap of ASTM B 62 bronze composition and threaded ends. Class 150 valves shall have lift-type Buna-N disc and union caps, and are to be furnished in lines with globe valves. Stockham B 322-B Crane 27 Powell 158 For backflow prevention in lines with gate valves, Y-pattern valves with swing-type disc may be furnished. For class 150 service, threaded ends: Stockham B-321 Crane 137 For class 200 Service, threaded ends: Hammond IB 944 Crane 36 Stockham B-345 Powell 560-Y 7. Check Valves, 2-1/2 Inches and Larger: Shall be iron body, bronze mounted, with body and cap conforming to ASTM A 126, class B, cast iron, flanged ends, and swing-type disc. Crane 373 Hammond IR 1124 15180-9

Powell 559 Stockham G-931 Alternative for above listed check valves shall be class 125/250 iron body, bronze mounted, wafer check valve, with ends designed for flanged type connection, aluminum bronze disc, EPDM seats, 316 stainless steel torsion spring, and hinge pin. Center Line CLC series Hammond IR 9253 Marlin A125 HZDSF Mission K12 HMP Stockham WG-971 8. Automatic valves controlling steam to a coil in a hot water tank shall be single seated type. When these valves are installed on a gravity return system, they shall be 2-position type (i.e. completely open or completely closed). 9. Valves on steam mains in boiler rooms shall be angle globe valves and be set to hold no condensate. E. Electric Motor Operated Valves: Electric motor operated valves shall have operating motors completely immersed in oil. F. Valves, General: 1. Handles or hand wheels on valves shall be removable and, unless specified to be of loose key type, shall be securely fastened to their stems. Valve handwheels, except those on radiator valves, shall be of steel, brass, or cast iron. 2. Boiler shut-off valves and valves on steam mains installed more than 6 feet above floor, shall be furnished with chain wheels and chains to within 6 feet of floor. Chains shall be free hanging and in a position to permit operation of valve from floor. When pulleys or extensions are required to locate these chains in such a position, furnish, and install said pulleys or extensions as required to provide a satisfactory operating installation. Extensions over one foot long shall be furnished with a supported outboard bearing. 3. Furnish and install chains or wire rope with required accessories to open safety valves from boiler room floor. 4. Radiator or convector valves shall be corner or angle type with composition handles, composition renewable discs, packing gland, union nut on tailpiece, 15180-10

unless otherwise specified. If exposed, they shall have a finished or plated exterior. 5. Temperature Control Valves: Refer to Section 15050. 6. Flow Control Valves: Refer to Section 15050. G. Flow Measuring Devices: Refer to Section 15050. H. Strainers: Refer to Section 15050. I. Condensate Drain Piping, from Air Handling Units: 1. Pipe: Type M tempered copper tube. 2. Fittings: Wrought copper. Refer to Section 15050. Furnish copper to threaded international pipe size adapters at threaded connections. 3. Joints: a. Soldered: 95-5 solder. b. Threaded: Pipe joint compound equivalent to WKM Key-Tite. J. Indirect Drains, Relief Valve Discharge Piping and Air Vent Discharge Piping: 1. Pipe: Type M tempered copper water tube. 2. Fittings: Wrought copper. Refer to Section 15050. Furnish copper to threaded international pipe size adapters at threaded connections. 3. Joints: a. Soldered: 95-5 solder. b. Threaded: Pipe joint compound WKM Key-Tite, or equal. K. Insulation: Refer to Section 15080. L. Pipe Anchors, Pipe Guides, Expansion and Contraction Devices: 1. Piping subject to expansion or contraction shall be fastened in a manner permitting strains to be evenly distributed and alleviated by swing joints or 15180-11

expansion loops or joints. Seismic restraints shall be installed so as not to interfere with expansion and contraction of piping. 2. Provide anchors in heating or cooling piping system, to restrain and control direction of movement for expansion or contraction in piping system. 3. Provide guides at specific locations in heating or cooling piping system in conjunction with slip or bellows type expansion joint. 4. When coils or unit housings are shock or vibration isolated, provide piping flexible metal connector not less than 10 inches long whether they are indicated on the Drawings or not. M. Flexible Metal Connectors: 1. Provide vibration elimination flexible metal connectors on chilled and hot water supply and return piping where rigidly supported pipes connects to unit housing coil attachments and units are supported by vibration isolators. 2. Schedule Numbers: a. FMC-1: Corrugated bronze metal hose with outer bronze braid in tubular sheath of woven metal wires. Connector with female copper tube ends for copper piping. Metraflex model BBS, or equal. b. FMC-2: Corrugated stainless steel metal hose with outer stainless steel braid in tubular sheath of woven metal wires. Connector with male pipe threads (NPT) for threaded piping. Metraflex model SST, or equal. c. FMC-3: Corrugated Bronze Metal Hose with outer bronze braid in tubular sheath of woven metal wires. Connector with female copper tubes ends for refrigeration piping. Metraflex model RAF, or equal. N. Refer to Sections 15050 or 15400, as applicable, for following: 1. Pipe Hangers and Supports. 2. Pipe Sleeves and Plates. 3. Pipe Flashings. 4. Relief Valves. 15180-12

5. Thermometers. 6. Pressure Gages. 7. Pressure and Temperature Test Plugs. 8. Access Panels. 9. Dielectric Fittings. 10. Expansion/Compression Tanks. 11. Condensate Traps. 2.02 EQUIPMENT A. Furnish centrifugal pumps capable of delivering rated capacity against total dynamic head as indicated on schedule and as specified for following: 1. Condenser Water Pump: a. Single stage base mounted, vertical split case, cast iron, bronze fitted construction. Pump impeller, casing bearings, capable of being serviced without disturbing piping connections. b. Impeller, enclosed type, hydraulically and dynamically balanced and keyed to shaft and secured with a suitable locknut. c. Pump shall employ a mechanical seal, with a carbon seal ring and ceramic (or tungsten carbide) seat. A shaft sleeve furnished under complete wetted area of mechanical seal. d. Bearing frame assembly of pumps fitted with oil lubricated bronze journal bearings and a hardened alloy steel shaft. e. Flexible coupling to absorb torsion vibration between pumps and motor. f. Motor: Resilient mounted, furnished with oil lubricated journal bearings. g. Pump: Factory tested, thoroughly cleaned, and painted with one coat of machinery enamel prior to shipment. A set of installation instructions to be furnished with pump at time of shipment. 15180-13

h. Acceptable manufacturers: Paco, Bell and Gossett, or Wienman. 2. Chilled Water Pumps: a. Horizontal, split case, fitted same as above, or end suction similar to that indicated below. b. Frame mounted with flexible coupling on shaft. c. Manufacturers: Paco, Bell and Gossett, or Weinman. 3. Hot Water Pumps: End suction, centrifugal, vertical split case, cast iron base mounted. Paco type L, Bell and Gossett, or Weinman. 4. Boiler Feed Pump: Two-stage, bronze fitted mechanical seals, double suction, regenerative turbine type with cast iron housing. Construction shall permit disassembly of pump without disturbing suction and discharge pipe connections. Pump impeller shall be bronze, mounted on stainless steel shaft supported by ball bearing on each side of pump casing. Pump shall be directly connected with a flexible coupling to an open drip-proof motor and mounted on a common steel base. Pump shall be operated from a boiler water level controller mounted on boiler. Pump shall be Roth Series C100, Skidmore, or Aurora and Pacific. Pumps shall be electrically interlocked to 24-hour day/night operating boiler controls. 5. Vacuum Pump: a. Vacuum pump shall be the packaged duplex-type with common base and be furnished with receiving tank, 2 pumping units, alternator, accessories, and controls. Huffman HVD series, or equal. b. Receiving tank shall be cast iron and be furnished with inlet strainer, gage glass, air discharge separator, and automatic ball float operated valve. c. Pumping units shall be bronze fitted throughout and rotating parts shall be dynamically balanced. Receiving tank, pumping units and motors shall be assembled by manufacturer to form an integral unit. Unit shall be furnished with condensate and air discharge valves, vacuum relief valve, compound gage, thermometer, and companion flanges for connections. 15180-14

PART 3 - EXECUTION 3.01 PIPING INSTALLATION d. Unit shall be pre-wired and be furnished with magnetic motor starters; overload protection for motors; float switch; vacuum switch; 3-position selector switch for automatic control, control by float only, or continuous operation; and an electrical alternator to automatically transfer operating sequence of pumps. Unit shall be electrically interlocked to 24-hour day/night operating boiler controls. A. Install piping systems for chilled water, condenser water, and hot water and steam heating systems, condensate drains, and miscellaneous piping required for equipment, as indicated on Drawings and as specified in Section 15050. 3.02 WATER PUMPS A. Install water pumps as indicated on Drawings and as specified unless otherwise noted. Provide vibration isolation and flexible pipe connections as specified in Sections 15070 and 15050. B. Floor mounted pumps shall be provided with a 4 inch high concrete base. For base, refer to Section 03300: Cast-In-Place Concrete. C. Piping shall be supported from building structure to prevent any strain on pump casing. In-line pumps shall be separately supported from piping by furnishing pump manufacturer's specialized spring support kit, if available; pump shall not be rigidly supported. D. Flanged connections shall be provided on pumps with a discharge connection larger than 2 inches. Smaller sizes may be furnished with threaded connections. Except for special guided inlet fittings, inlets to suction side of pumps shall be a minimum of 10 diameters of straight pipe free from strainers, valves or fittings. On discharge side, minimum length of uninterrupted length of straight pipe shall be 5 diameters. E. Pumps, one horsepower or larger, shall be installed with required pump connections for noise and vibration isolation and not to compensate for misalignment. 3.03 AIR ELIMINATION A. Heating and chilled water piping and steam or hot water heating and/or cooling equipment shall be installed in a manner so that air will be eliminated from lines or equipment during operation. Pitch pipe lines as specified in Section 15050. 15180-15

B. Manual air valve shall be installed at each high point of chilled or hot water circulating lines, on each chilled water or hot water heating unit unless unit can vent through outlet connection. Refer to valves as specified under Section 15050. C. Approved air vent valves shall be installed with drains to nearest floor sink or outside building as indicated. 3.04 CHEMICAL POT FEEDER A. Provide a chemical pot feeder in each of chilled water and hot water systems as specified in Section 15460: Water Treatment Equipment. 3.05 CONDENSER WATER TREATMENT A. Provide condenser water treatment as specified in Section 15460: Water Treatment Equipment. 3.06 CLEANUP A. Remove rubbish, debris and waste material and legally dispose of off the Project site. 3.07 PROTECTION A. Protect the Work of this section until Substantial Completion. END OF SECTION 15180-16