Model Combination Shower Eye/Face Wash

Similar documents
Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash

Model 7656WCC Eye/face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model 9001, Alarm

Model 9001, Alarm

Model TWBS.EW.H Tempered Water Blending System

Model 1011/1011HPS Drinking Fountain

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 9201EFE Tempered Water Blending System

Model 9201EW Tempered Water Blending System

Model TWBS.SHE Tempered Water Blending System

Model 7500EB Portable Eyewash with Heater

Model 7611 Eye/Face Wash

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model H1011.8/H1011.8HPS Water Cooler

Model 1900 Retrofit Bottle Filler

INSTALLATION & TESTING MANUAL

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Model 7603BL/7603BL240 Heated Blanket for 7603 Portable Eyewash

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

3121FR Pedestal Mounted Drinking Fountain

INSTALLATION & TESTING MANUAL

H Barrier-Free Wall Mounted Electric Drinking Fountain

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

H1011.8HPS Barrier-Free Wall Mounted Electric Drinking Fountain

H Barrier-Free Wall Mounted Electric Drinking Fountain

8317CTFP AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER Freeze Resistant

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Model 1920/1920HPS/1920W Bottle Filler

EMERGENCY DRENCH SHOWER

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

model1117l with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

Installation Instructions / Warranty

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

SPEAKMAN SPEAKMAN SPECIFICATIONS

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

TUB AND SHOWER FAUCET

Installation & Operation Manual

TUB AND SHOWER FAUCET

Installation & Operation Manual

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

ADA Compliant Wall-Mount Fountain and Bottle Filler

Installation Instructions / Warranty. Metris 31060XX XX XX1

Installation Instructions / Warranty

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

2001 Smith Eastern Corporation

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

Flat Line Spray Systems Kits

Installation Instructions / Warranty

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Installation Instructions / Warranty


Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Acrylic Claw Foot Tub

55-Gallon Dispenser Package

55-Gallon Dispenser Package

Installation Instructions / Warranty

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

TITAN FLOW CONTROL, INC.

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

Installation and Owners manual

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

Installation Instructions / Warranty. Hansgrohe Single Control Kitchen Mixers

Installation Instructions / Warranty. Starck 10111XX XX XX1

Heater Installation Kit

Installation Instructions / Warranty. PuraVida 15775XX1

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

8200 Combination Units

Installation S

Installation, Operation and Maintenance Instructions

MERIDIAN MODEL# 3793

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

Installation Instructions PP-AS20 Anti-Scale System

Desiccant Air Drying System

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation Instructions / Warranty. Massaud

Installation and Owners manual

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Desiccant Air Drying System

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

Flipside Handshower and Showerhead Installation and User Guide

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Operation, Maintenance and Installation Manual

INSTALLATION INSTRUCTIONS

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 8300.158 Combination Shower Eye/Face Wash No. 2080167(12) NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297 12/14 Model 8300.158 Page 1 of 5

LOCATION OF UNIT: The Model 8300.158 Emergency Shower should be installed in close proximity to potential accident areas. It should be clearly identified, free from obstructions and easy to access. SUPPLY LINE: The minimum recommended line size is 1-1/4 IPS with 30-90 psi (2-6 ATM) flowing pressure. Where sediment or mineral content is a problem, an inlet filter is recommended. PLUMBING CONNECTIONS: Inlet supply is female 1-1/4 IPS. Waste outlet is female 1-1/4 NPT. MAINTENANCE: In freezing conditions, wipe eye/face wash head and dust cover dry after each use to prevent unwanted ice build up. INSTALLATION PROCEDURE Refer to Installation Drawing for clarification. Check parts list to insure all required parts are included. Use pipe joint sealant PST #565 (Loctite) on all connections. STEP 1: STEP 2: STEP 3: STEP 4: STEP 5: STEP 6: STEP 7: Prepare the emergency shower foundation by using the floor flange assembly as a template. Locate the three holes for the 3/8-16 UNC x 6 anchor bolts (not supplied). They should extend 1 above the floor level. Once the concrete foundation is ready (dry), assemble the floor flange assembly to the anchor bolts; then securely fasten with 3/8-16 UNC Hex nuts and 3/8 washers (not supplied). Seal and tighten floor flange and tee making certain the waste tee is facing the proper location and the foot control holes are facing side to side. Assemble nipple (1-1/4 x 21-1/2 ) to the floor flange assembly and tighten with a pipe wrench. Assemble the eye/face wash loop assembly to the 21-1/2 nipple from step three. Connect the pipe wrench to the galvanized nipple between the two tees to avoid damage. Assemble in the following order: Attach nipple (1-1/4 x 24 ) onto the loop assembly (4). Attach (1-1/4 ) coupling to nipple. Attach nipple (1-1/4 x 24) onto the coupling. Attach tee (1-1/4 x 1-1/4 x 1 ) with ball valve onto nipple. Attach nipple (1-1/4 x 19-1/2 ) onto ball valve. Assemble the (1 ) elbow onto the horizontal nipple (1 x 19-1/2 ), and attach the showerhead onto the elbow. Assemble the sign onto the unit. Use the strap, screws, washers and nuts provided to mount the sign onto the upright. The sign should be positioned for maximum visibility. STEP 8: Before connecting the supply water line to the emergency shower, FLUSH THE LINE THOROUGHLY. 12/14 Model 8300.158 Page 2 of 5

TROUBLESHOOTING PROBLEM REPAIR CHECKLIST 1. No flow. 1. Check the main shut-off valve. 2. Insufficient water flow 2. Verify minimum 30 psi (2 ATM) flowing supply line pressure. 3. Insufficient water flow on eye/face wash, however, shower is sufficient. 4. Eye/face wash streams do not meet at desired eye level. 5. Insufficient water flow at the showerhead, however, eye/face wash is sufficient. 3 Probable clogging of flow control due to inadequate line flushing. Unscrew eye/face wash head and adapter. Disassemble adapter to gain access and clean rubber flow control. 4. Possible blocked flow control, see above solution. Possible non-leveled eye/face wash assembly. 5. Probable clogging of flow control inside showerhead. Unscrew showerhead off of elbow and clean rubber flow control. 6. Water does not drain properly 6. Check your drain system for debris. Check the main waste line of your building to see if it does handle the capacity required for the entire drainage system. 7. Water leaks between joints or fittings 8. Water flows from bleed valve when in closed position. 7. Tighten loose connections. If leak persists, the application of hot water will sometimes reseat improperly applied joint compound. After 30 minutes wait and retest. A persistent leak will necessitate reassembly and additional sealant. 8. Remove nut and flag. Rotate stem 180 and reassemble flag and nut. For more information about Haws products, see our website: www.hawsco.com 2014 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 12/14 Model 8300.158 Page 3 of 5

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. ITEM DESCRIPTION PART NO. 1 BOWL SP90 2 EYEWASH DUST COVERS 9095 PARTS BREAKDOWN 4 SHOWER HEAD 6 PULL ROD 7 EYEWASH HEADS 8129FC SP200 SP11FC 8 FLOOR FLANGE SP75 9 BLEED VALVE SP158B 10 STRIPE TAPE SP185 12 11 VALVE ASSEMBLY 12 VALVE ASSEMBLY SP229.158 SP260.158 13 SHOWER SIGN SP178 14 TEST TAG SP170 13 4 14 10 6 9 1 2 7 11 8 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (755) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY MODEL(S) PART NUMBER ECN: 4938 VWC 0002080167 DRAWN DATE CHKD 8300.158 SHOWER DRAWING NO. REV CLF 03/17/93 APPROVED DATE EYEWASH COMBO 11490A00 12 FV 01/08/15 SCALE: 1:8 DRAWING TYPE: PARTS BREAKDOWN SIZE: A SHEET 1 OF 1 WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER. C 2014 Haws Corporation - All Rights Reserved R HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. PAGE 4 of 5

PAGE 5 of 5 THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 30-5/8" 778mm SUPPLY 1 1/4" IPS 11" 279mm 3 SELF DRAIN VALVE Ø9" Ø229mm 82" 2083mm MINIMUM 10-3/16" 259mm SELF DRAIN VALVE AIR GAP SP158 FREEZE PROTECTION VALVE (OR OPTIONAL SP157B SCALD PROTECTION VALVE) 88-1/4" 2242mm 30 MOUNTING DETAIL 3X Ø3/8" Ø10mm Ø8" Ø203mm BC 43" 1092mm WASTE 1 1/4" IPS FLOOR LINE 6-3/4" 171mm NOTES: 1. DIMENSIONS MAY VARY BY ± 1/2 INCH [13mm]. 2. TO COMPLY WITH ANSI Z358.1-2009 FOR EMERGENCY EYEWASH OR EYE/FACE WASH AND SHOWER EQUIPMENT: - UNIT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND ACCEPTABLE PLUMBING PRACTICES. - EYEWASH OR EYE/FACE WASH SHALL BE POSITIONED WITH NOZZLES NOT LESS THEN 83.8 CM (33 IN.) AND NO GREATER THAN 114.3 CM (45 IN.) FROM SURFACE ON WHICH USER STANDS AND 15.3 CM (6 IN.) MINIMUM FROM WALL OR NEAREST OBSTRUCTION. - SHOWER SHALL BE POSITIONED SO THAT SHOWER HEAD IS NOT LESS THAN 208.3 CM (82 IN.) NOR MORE THAN 243.8 CM (96 IN.) FROM SURFACE ON WHICH USER STANDS. ECN NO. REVISED PER BY: - SHOWER SPRAY PATTERN SHALL HAVE A MINIMUM DIAMETER OF 50.8 CM (20 IN.) AT 152.4 CM (60 IN.) ABOVE SURFACE ON WHICH ECN: 4938 VWC USER STANDS, AND CENTER OF SPRAY PATTERN SHALL BE LOCATED AT LEAST 40.6 CM (16 IN.) FROM ANY OBSTRUCTION. DRAWN: DATE: CHK'D.: 3 DO NOT USE PIPE SEALANT. IF NECESSARY USE DOW CORNING 832 SEALANT PLACING 5 SMALL BEADS ON THE MALE THREADS. CH 07/91 JUST ABOVE THE FIRST THREAD. APPROVED: DATE: FV 01/08/15 C R 2014 MODEL(S) 8300.158 SHOWER EYEWASH COMBO 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (755) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM PART NUMBER DRAWING NO. SCALE: 1:18 DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 1 Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080167.D REV 09562A00 12