Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Similar documents
Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

GB162 Concentric Horizontal Vent Kit

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

Operating Instructions

User manual. Logano GC 124 II. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Intelligent cascading kit

Operating instructions

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

Bosch 80% AFUE Gas Furnace BGS80 Model

INDOOR MODEL Flow Modulated with Hydro-generated Ignition

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Do not use this vent pipe or fittings for venting incinerators of any kind.

RTG 199 HE INDOOR MODEL. RTG 199 HEN - Natural Gas RTG 199 HEX - Propane (LP Gas) Installation and Operation instructions

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation instructions

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

INSTALLATION AND SERVICE MANUAL

USER S INFORMATION MANUAL

ML180UH SERIES GAS FURNACE WARNING WARNING

INSTALLATION AND SERVICE MANUAL

USER S INFORMATION MANUAL

Greentherm 9800 SE 160/199 SEC 199

Installation instructions Logamax plus. GB162-L.B. 80 kw GB162-L.B. 100 kw. Read carefully before carrying out installation and maintenance.

WARNING FIRE OR EXPLOSION HAZARD.

Direct Vent System Required

EL195DFE SERIES GAS FURNACE WARNING

Connecting cable. Installation instructions (2018/04) US

ASX7-4-IOM-6 J

INSTALLATION AND SERVICE MANUAL

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

Operating instructions

VENTING APPLICATION GUIDE

INSTALLATION INSTRUCTIONS

EL195UH SERIES GAS FURNACE WARNING

Vent Supplement Ultra-80, -105, -155, -230 & -310

EL195UHE SERIES GAS FURNACE WARNING WARNING

INSTALLATION INSTRUCTIONS G2D93CT, G2D93CU, G2D95CT, & G2D95CU High Efficiency Multiposition Gas Furnace with System Sentry Control System WARNING

Residential Gas Water Heater with the Flame Lock Safety System Installation Instructions and Use & Care Guide

USER S INFORMATION MANUAL SLP98UHV SERIES

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

USER S INFORMATION MANUAL

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

TL-Pro 175C/199C INDOOR MODEL. TL-Pro 175/199 C - Natural Gas TL-Pro 175/199 C- Propane (LP Gas) Installation and Operation instructions

C 1050 ES - Natural Gas C 1050 ES - Liquefied Petroleum (LP) Gas

ASX7-5-IOM-3 J

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS A95DF2V, 95G2DFV Warm Air Gas Furnace / Downflow Air Discharge Direct Vent & Non-Direct Vent

Installation Instructions for use by heating contractor. Vitodens Common Venting System IMPORTANT

INSTALLATION INSTRUCTIONS

G61MPV SERIES GAS FURNACE WARNING

USER S INFORMATION MANUAL

Installation instructions for the T 9820 Gas Dryer

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

MFC Series Boiler Vent and Combustion Air Guide

EL296UHV SERIES GAS FURNACE WARNING WARNING

C 1210 ES/ESC - Natural Gas C 1210 ES/ESC - Liquefied Petroleum (LP) Gas

Installation and Service Instructions LoganoUS/CA GC 144 II

Installation Instructions and Use & Care Guide

Power-Fin 4:1 HOT WATER HEATING BOILERS DOMESTIC HOT WATER SUPPLY BOILERS 1,500,000, 1,700,000 and 2,000,000 Btu/hr MODELS

Residential Gas Water Heater with the Flame Guard Safety System Installation Instructions and Use & Care Guide (Flammable Vapor Ignition Resistant)

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4

WARNING FIRE OR EXPLOSION HAZARD.

INSTALLATION AND SERVICE MANUAL. Hot Water Heating Boilers Domestic Hot Water Supply Boilers 399, ,000 Btu/hr Models

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

C 950 / 1050 ES C 950 / 1050 ES - Natural Gas / C 950 / 1050 ES - Liquefied Petroleum (LP) Gas

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

Service Instructions. Logamax plus GB kw/100 kw. Condensing gas boiler. For the contractor

Polypropylene (PP) Common Venting

Venting Supplement Saf-T Vent 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Hazard definitions

Installation & Operation Manual Models:

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Installation and maintenance instructions

Installation & Maintenance Instructions

INSTALLATION INSTRUCTIONS G60UH(X) Series

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Logamax plus. Notice! This manual is available in the English and French language. This manual must be retained for future reference.

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

RESIDENTIAL GAS WATER HEATERS FVIR GAS WATER HEATER (FLAMMABLE VAPOR IGNITION RESISTANT) FOR SPACE HEATING AND POTABLE WATER HEATING ONLY.

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES

Installation and Operation Instructions Manual

Owner s Manual. ama PG9MXA TWO --- STAGE CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

GOLD. Venting Supplement. Water Boiler Series 3 & 4. for 3" venting

Trinity Tft Model Numbers: Tft Version Date:

INSTALLATION INSTRUCTIONS FOR FLUE KIT

VENTING GAS APPLIANCES NFPA 54 CODE

COMBUSTION AIR SYSTEM

CHIMNEY INSTALLATION. Technical Bulletin #1

INSTALLER'S GUIDE MASONRY CHIMNEY VENT KIT WARNING: BAYVENT800B 18- CH23D2-05

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

Installation Instructions Remote Blowers

Installation and Servicing Instructions

Installation Instructions for use by heating contractor. Common Venting with Flue Vent Damper IMPORTANT

USER S INFORMATION MANUAL

Transcription:

Installation instructions Cascade Venting System for RTG 199HE Back to back Basic Set for units 1 and 2-7 736 501 253 6 720 811 762 / 238-50973-00A (2014/05)

Table of contents Table of contents 1 Key to symbols and safety instructions................... 3 1.1 Key to symbols................................. 3 1.2 Safety instructions.............................. 3 2 Accessory assembling................................. 5 2.1 Maximum and minimum permitted vent lengths..... 14 2 6 720 811 762 (2014/05)

Key to symbols and safety instructions 1 Key to symbols and safety instructions 1.1 Key to symbols Warnings The following keywords are defined and can be used in this document: NOTICE indicates a situation that could result in damage to property or equipment. CAUTION indicates a situation that could result in minor to medium injury. WARNING indicates a situation that could result in severe injury or death. DANGER indicates a situation that will result in severe injury or death. Important information Additional symbols Warnings in this document are identified by a warning triangle printed against a grey background. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken. This symbol indicates important information where there is no risk to people or property. Symbol Explanation Step in an action sequence Cross-reference to another part of the document List entry List entry (second level) Table 1 1.2 Safety instructions Read all instructions before installing. Perform the steps in the indicated sequence. Have the water heater inspected by a trained service technician at least once every year. Failure to comply with these instructions can result in severe, possibly fatal, personal injury as well as damage to property and equipment. Installation and servicing Ensure that only a licensed contractor installs or services the water heater. On hot components use only material with adequate temperature stability. Installation and commissioning In the Commonwealth of Massachusetts, the water heater must be installed by a licensed plumber. If you smell flue gas Switch off the appliance. Open windows and doors. Inform a trained and certified installer. Insufficient ventilation may cause toxic flue gas to escape. Risk of poisoning. Never close off or reduce the size of the air intake and outlet openings. The appliance must not be operated until any obstructions have been removed. Inform the system operator in writing of the problem and the associated dangers. Danger from escaping flue gases Ensure all vent pipes and chimneys are not damaged or blocked. Connect only one appliance to each vent system or chimney liner. The venting system piping must not feed into another air extraction duct. Do not route the flue system piping through or inside another air extraction duct. Combustion air Keep the combustion air free of corrosive substances (halogenated hydrocarbons that contain chlorine or fluorine compounds). Maintenance Customers are advised to: Sign a maintenance and inspection contract with an authorized contractor. Inspect and maintain the water heater as necessary and on a yearly basis. Service as needed. Use only genuine spare parts. For your safety DANGER: Fatal accidents! Carbon monoxide poisoning. Carefully plan where you install the heater. Correct combustion air supply and flue pipe installation are very important. If a gas appliance is not installed correctly, fatal accidents can result such as carbon monoxide poisoning or fire. DANGER: Carbon monoxide poisoning. Exhaust gas must be vented to outside using approved vent material. (In Canada use only ULCS636 approved material). Vent and combustion air connector piping must be sealed gas-tight to prevent flue gas spillage, carbon monoxide emissions and risk of fire, resulting in severe personal injury or death. Approved vent terminations must be used when penetrating to the outside. NOTICE: Do not obstruct the flow of combustion and ventilation air. NOTICE: The RTG 199HE and RTG 199ME are approved for the US and Canada with this common venting system as described in this manual. NOTICE: The installation must comply with national, state, and local code, and the Water Heater Installation Instructions and this Vent System Installation Manual must be followed exactly. NOTICE: Combustion air requirements The cascade system is only approved for combustion air drawn from the room, and the installation site must provide sufficient combustion air for safe and reliable operation of the entire cascade. 6 720 811 762 (2014/05) 3

Key to symbols and safety instructions Each appliance requires 9.950 cubic feet of available combustion air, or a minimum of 1.243 square feet of space with an 8 foot ceiling to operate. If this amount of air space is not available, provisions must be taken to provide sufficient combustion air from the outside. Always install the combustion air grill to prevent foreign objects from falling into the unit. If other appliances that draw in air or exhaust air share the same space, their requirements must be taken into consideration when sizing the air supply. Always follow local codes and regulations if they are more stringent. Appliances located in unconfined spaces a) An unconfined space is one whose volume is greater than 50 cubic feet (1.42 cubic meter) per 1,000 BTU/Hr (292.81 Watts) of the combined rating of all appliances installed in the space. That would be 9.950 cubic feet (281.8 cubic meters) for the water heater alone. b) In unconfined spaces in buildings of conventional frame, masonry, or metal construction, infiltration air is normally adequate to provide air for combustion. Appliances located in confined spaces The confined space must be provided with two permanent openings, one commencing within 12 inches (304.8mm) of the top and one commencing within 12 inches (304.8mm) of the bottom of the enclosure. Each opening must have a minimum free area of one square inch per: 1,000 BTU/Hr (292.81 Watts) if all air is taken from inside the building 2,000 BTU/Hr (585.62 Watts) if all air is taken from the outside by horizontal ducts 4,000 BTU/Hr (1171.24 Watts) if all air is taken from the outside by direct openings or vertical ducts Or the confined space must be provided with one permanent opening or duct that is within 12 inches (304.8mm) of the ceiling of the enclosure. This opening must have a minimum free area of one square inch per: 3,000 BTU/Hr (878.43 Watts) if all air is taken from the outside by a direct opening or vertical duct Louvers, grills and screens have a blocking effect, when used, increase the sizes of your openings by 300% for wood louvers (as wood type will reduce the free air by 75%) and 43% for metal louvers (as metal will reduce the free air by 30%). Refer to the National Fuel Gas Code for complete information. In buildings of tight construction all air should be taken from outside. 4 6 720 811 762 (2014/05)

2 Accessory assembling Fig. 1 [1] 7 736 501 148 (Ø 6") (Ø 150mm) - Condensate trap and cover [2] 7 736 501 125 (Ø 6") (Ø 150mm) - Header pipe [3] 7 736 501 110 - Condensate siphon [4] 7 736 501 141 (Ø 4") (Ø 100mm) - Elbow [5] 7 736 501 256 (Ø 4") (Ø 100mm) [6] 7 736 501 123 (Ø 4"/ 6") (Ø 100/150mm) - Reducer [7] 7 736 501 121 (Ø 4"/ 5 29 / 32 ") (Ø 100/150mm) - Check valve [8] 7 736 501 090 (Ø 4") - 9.8 " length (Ø 100mm) - 250mm length 7 736 501 143 (Ø 4") - 19.7 " length(ø 100mm) - 500mm length [9] 7 736 501 256 (Ø 4") (100mm) [10] 7 736 501 111 (Ø 3 1/2" / 6") (Ø 80/100mm) - Reducer [11] 7 736 501 257 (Ø 3 1/2") (Ø 80mm) - Clamp [12] 7 736 501 099 (3" / Ø 3 5 / 32 ") (76.2/Ø 80mm) - Extension [13] 7 736 501 101 (3") (76.2mm) - Combustion air intake grill 6 720 811 762 (2014/05) 5

Fig. 2 Fig. 4 Fig. 3 Fig. 5 6 6 720 811 762 (2014/05)

360 6 720 604 873-17.1O Fig. 6 Apply lubricant evenly all around all gaskets Fig. 8 Fig. 7 6720804520-01.1V Fig. 9 6 720 811 762 (2014/05) 7

Fig. 10 Fig. 12 Fig. 13 Fig. 11 8 6 720 811 762 (2014/05)

Fig. 14 6 720 811 762 (2014/05) 9

Fig. 15 Complete setup of the 2 unit cascade. For units 3 and 4 follow the installation instructions of the extension kit. 10 6 720 811 762 (2014/05)

Fig. 16 Vertical setup - for horizontal termination see Fig. 25 [1] 7 736 501 119 - Vertical termination [2] 7 736 501 133-80" (2000mm) - Extension 7 736 501 135-40" (1000mm) - Extension 7 736 501 137-20" (500mm) - Extension [3] 7 736 501 133-80" (2000mm) - Extension 7 736 501 135-40" (1000mm) - Extension [4] 7 736 501 113 - Wall/ceiling bracket [5] 7 736 501 129 - Support elbow 6 720 811 762 (2014/05) 11

Ø 6 1/4 (160 mm) 6720804524-06.1V Fig. 18 1 Fig. 19 6720801430-17.1V Ø 6 (150 mm) 6720804524-05.1V Fig. 17 [1] 7 736 501 095 Fig. 20 6720801430-18.1V It is recommended to consult a professional roofer to ensure a long lasting water tight seal is established. 3. 5. 4. 6720801430-19.1V Fig. 21 12 6 720 811 762 (2014/05)

1 1 Ø 6 (150 mm) Fig. 24 6 720 610 165-03.2O It is recommended to consult a professional roofer to ensure a long lasting water tight seal is established. Fig. 22 [1] 7 736 501 091 Flashing for 12/5 to 12/12 pitch (25-45 ) 7 736 501 093 Flashing for flat roof to 12/5 pitch (0-25 ) A > 15 ¾ " (400 mm) 6720804054-07.1V > 20" (500 mm) Table 2 Choose the proper vent pipe height A depending on the typical snow accumulation for the location 6720801430-21.1V Fig. 23 6 720 811 762 (2014/05) 13

2.1 Maximum and minimum permitted vent lengths Fig. 25 [1] 7 736 501 117 - Horizontal wall terminal [2] 7 736 501 116 - Wall cover plate Ø 6 (150mm) L eq TTNR 40" (1m) 7 736 501 132 45 90 Table 3 80" (2m) 7 736 501 146 NOTICE: Minimum vent length Not considering the appliance headers and the termination, a minimum 40" (1m) of horizontal run is required. NOTICE: Maximum vent length Not considering the appliance headers and up to one 90 elbow, but including the termination, the total combined horizontal and vertical vent length must not exceed 100' (30m). See table 3 for equivalent vent length of 45 and 90 elbows. 14 6 720 811 762 (2014/05)

Notes 6 720 811 762 (2014/05) 15