CU-02 with Senaco Plus

Similar documents
Instruction Manual December 2001 ENACOCU02

Instruction Manual August sitrans CU 02

Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Instruction Manual April sitrans AS 100

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Quick Start Manual July pointek CLS100

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

Analog Room Pressure Monitor RPC Series

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

multiranger 100 / 200

POINTEK CLS 200 OINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Functional Safety Manual June pointek CLS500/LC500

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Oxygen (O2) Single-Point Gas Detection System

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

LC2200 Level Controller Installation and Maintenance Instructions

EXTINGUISHING AGENT RELEASE MODULE

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Product Manual SZ1145

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

Combustible Gas Detection and Control System

Process Alarm Module RTA 421

Carbon Monoxide Transmitter

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Product Manual SZ1144

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Two-Channel Gas Controller

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Software Version 2.01 LEVEL MONITOR MODEL 220

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

MO n : 12JMC rév A

Greentrol Automation, Inc.

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

POINTEK CLS 300 OINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

D3000. Installation & Setup Guide

CTT8 TEMPERATURE MONITOR DEVICE

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

B-40/B-41 Modulating Temperature Controller

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Pioneer-R16 Gas Monitor Operator s Manual

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

vibration switch

Operator: Save these instructions for future use!

Oakton TEMP 9500 Advanced Multiparameter Controller

Beacon 800 Gas Monitor Operator s Manual

C-Bus Four Channel General Input Unit Installation Instructions

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Multi-Gas-Controller MGC2

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

MTRA-FSP Level Control Relay. Installation & Operation Manual

CT500 Electronic Thermostat

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

UDC100 Universal Digital Controller Specifications

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

PRODUCT CONFORMITY CERTIFICATE

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

I/A Series 716C 1/16 DIN Temperature Controller

INSTALLATION INSTRUCTIONS

Operations Manual. Motion Detector Module Model ZS10

UNC100 Integra Manual

Duct and Rough Service Carbon Monoxide Sensor

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

QD-ENG-68 Controller for Thermoelectric Thermal Management

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

DTA. Motor thermistor relay. Benefits. Description

CMD420 / CMD421 Series

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

PROGRAMMABLE 7-DAY RF THERMOSTAT

Transcription:

CU-02 with Senaco Plus Instruction Manual PL-509 July 2001 U-02 SENACO 33455090 Rev. 1.1

Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc. 2000. All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc. 1954 Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 Email: techpubs@milltronics.com For the library of SMPI instruction manuals, visit our Web site: www.milltronics.com Siemens Milltronics Process Instruments Inc. 2001

ABOUT THE SENACO CU 02 CU-02 is to be used only in the manner outlined in this instruction manual. The Senaco Control Unit, CU 02, provides relay and analog outputs for interfacing a Senaco Sensor into a process. The CU 02 input device may be any one of the family of Senaco Sensors used for monitoring stress wave activity. If using one of the intrinsically safe I.S. Sensors, the use of approved barriers is required. FEATURES LCD display 2 SPDT (form C) relays 4-20 ma output, isolated programmable start up delay programmable alarm delay SPECIFICATIONS Power:» see nameplate for voltage configuration (100/115/200/230 V ac ±15%, 50/60 Hz, 10 VA) Environmental:» location:» indoor» altitude:» 2000 m max» ambient temperature:» 20 to 50 C ( 4 to 122 F)» relative humidity:» 80% for temperatures up to 31 C» installation category:» II» pollution degree:» 2 Input: Display: Relay: Analog Output:» Senaco Sensor» liquid crystal» three 9 mm (0.35") digits» multisegment graphic for operation status» 2 alarm/control relays» 1 form C SPDT contact per relay, rated 5 A at 250 V ac non inductive» isolated 4-20 ma» 750 Ω load max Enclosure:» 55 mm W x 75 mm H x 110 mm D (2.2" W x 3" H x 4.4" D)» polycarbonate» mounting: - DIN rail (DIN 46277 or DIN EN50022) - wall / panel mount Approval: Weight:» CE *, FM, CSA NRTL/C» 550 g (18 oz) * EMC preformance available upon request. PL-509 3

INSTALLATION Installation shall only be performed by qualified personnel and in accordance with local governing regulations. This product is susceptible to electrostatic shock. Follow proper grounding procedures. The unit must be mounted inside a suitable and fully enclosed rack or panel. MOUNTING DIMENSIONS 110 mm (4.4") 75 mm (3") 61 mm (2.4") 55 mm (2.2") PANEL MOUNTING 38 mm (1.5") 4.5 x 5.75 mm (1.8" x 0.2") mounting slot (2 places) 38 mm (1.5") 61 mm (2.4") drill and tap for 4 mm (#8) screw, (2 places) PL-509 4

RAIL MOUNTING Mounting Removal PL-509 5

INTERCONNECTION CONNECTION LAYOUT All field wiring must have insulation suitable for at least 250 V. Relay contact terminals are for use with equipment having no accessible live parts and wiring having insulation sutable for at least 250 V. The maximum allowable working voltage between adjacent relay contacts shall be 250 V. SYSTEM DIAGRAM Senaco CU-02 Approved I.S. Barrier Senaco Plus Sensor Senaco CU-02 Senaco Plus Sensor I.S. APPLICATIONS NON I.S. APPLICATIONS SENACO I.S. SENSOR CONNECTION approved barrier red black white shield For I.S. Sensors, the use of an approved barrier is required. Pair up or disregard one of the black wires. Refer to I.S. Sensor manual. PL-509 6

SENACO NON I.S. SENSOR CONNECTION red black shield brown white RELAY OUTPUT CONNECTION * AUTO RESET (P14 / 24 = 0) MANUAL RESET (P14 / 24 = 1) reset button All relays are certified for use in equipment where the short circuit capacity of the circuits in which they are connected is limited by fuses * having ratings not exceeding the rating of the relays. refer to Operation\ Alarm ANALOG OUTPUT CONNECTION to customer instrumentation 4-20 ma isolated output into 750 Ω max POWER CONNECTION PL-509 7 refer to nameplate for voltage requirement The equipment must be protected by a 15 A fuse or circuit breaker in the building installation. A circuit breaker or switch in the building installation, marked as the disconnect switch shall be in close proximity to the equipment and within easy reach of the operator.

OPERATION START DELAY On initial powering of the CU 02, the start delay circuit prevents the relays from going into alarm for the period of time programmed (parameter P80). DISPLAY relay 1 alarm flag relay 2 alarm flag program alphanumeric % parameter value percent reading The CU 02 normally displays the input signal level (Vsens) from the Senaco sensor in volts, or in percentage of the programmed span (P 3 P 2). The selection is made while viewing Vsens. Press: for percent for volts Damping is provided to slow the response of the display when rapid or minor fluctuations in the process or machinery operation are encountered. The greater the damping value (P86), the slower the response. RELAY The CU 02 has two onboard programmable relays (P10/20). Under normal operation, the relays are energized (N.O. contact closed). Under alarm condition, the alarm flag starts flashing immediately, indicating that the relay delay (P13/23) has started counting. If the alarm condition ceases before the relay delay expires, the flashing alarm flag is aborted. If the relay delay expires, the relay de-energizes and the contacts change state. The alarm flag ceases flashing and remains on. Upon resumption of normal operating condition, the alarm flag disappears. The relay and relay delay reset manually or automatically depending on the mode selected (P14/24). If automatic, the reset is immediate. If manual, the reset occurs upon actuation of the reset button (latch). PL-509 8

Each relay is programmable for either: high alarm: alarm condition occurs when the sensor signal level (%) is of a greater value than the high% setpoint e.g. alarm above 80% on off low alarm: alarm condition occurs when the sensor signal level (%) is of a lesser value than the low% setpoint on e.g. alarm below 20% off out of bound: alarm condition occurs when the sensor e.g. alarm beyond signal level (%) is of a greater value 20% and 80% than the high% alarm setpoint or of a lesser value than the low% alarm setpoint on off in bound: alarm condition occurs when the sensor signal level (%) is of a value between the low% and high% alarm setpoints e.g. alarm between 20% and 80% on off The individual relay functions in combination provide: high% and high-high% alarm high% and low% alarm high% and bound alarm low% and low-low% alarm low% and bound alarm bound 1 and bound 2 alarm ANALOG OUTPUT The CU 02 provides an isolated analog 4-20 ma output by calibration of the 4 and 20 ma levels to the operating span of the input signal (Vsens) from the Senaco sensor. In the case where Vsens passes the lower and upper limits of the span, low and high ma limits are factory set to nominal values of 2 and 22 ma respectively, providing indication of overrange activity. Damping is provided to slow the response of the analog output when rapid or minor fluctuations in the process or machinery operation are encountered. The greater the damping value (P85), the slower the response. SECURITY The CU 02 is factory shipped with security (P 1) disabled, allowing program access. If it is desired to deny programming access (viewing access is not restricted), security can be enabled by entering the enable code. If it is desired to regain programming access, the disable code must be entered. Refer to Security Alteration. PL-509 9

PARAMETER RESET A master reset (P99) is provided to automatically reset all programming parameters to their factory values. However, if it is desired to reset an individual parameter, this can be done by entering its factory value, as given in Parameter List. SETTING UP To Access Program: press display run display program starts at parameter 1 To Select a Parameter: to scroll up or down to desired parameter To View a Parameter Value: select parameter, e.g. P 3 display parameter value, e.g. 2.50 exit PL-509 10

To Change a Parameter Value: select parameter, e.g. P 3 display parameter value, e.g. 2.50 Security Must Be Disabled! increase or decrease to the desired value. If no response, security not disabled! Must Be Pressed To Save Change! save and exit To Return to Run Display: from the parameter display, e.g. P 3 exit program and return to run display OPERATING VALUES With the Senaco Sensor and Control Unit properly mounted, connected and powered. Run the material or machinery through its range of operation. Note the following values where applicable: normal operating level abnormal operating level Vnorm = Vabn = Where applicable values are unobtainable, they can be estimated and entered while programming. PROGRAMMING Security must be disabled to set programming functions. CALIBRATION: 0-100% / 4-20 ma calibrate the 0% / 4 or 20 ma level by entering the value of Vnorm into P 2. calibrate the 100% / 20 or 4 ma level by entering the value of Vabn into P 3. The difference between P 2 and P 3 must be at least 0.2 V for full 4-20 ma span. PL-509 11

RELAYS For precise determination of alarm setpoints, view the run display in percent and run the material or machinery through its range of operation. Note the % values corresponding to the alarm points. RELAY 1 enable, P10 = 1 setpoint: for high% alarm, P11 = enter setpoint value in % P12 = 0 for low% alarm, P11 = 0 P12 = enter setpoint value in % for out of bound alarm, P11 = enter high% setpoint value in % P12 = enter low% setpoint value in % for in bound alarm, P11 = enter low% setpoint value in % P12 = enter high% setpoint value in % relay delay set (1-999 sec), P13 reset select, P14 = 0 / auto = 1 / manual RELAY 2 enable, P20 = 1 setpoint: for high% alarm, P21 = enter setpoint value in % P22 = 0 for low% alarm, P21 = 0 P22 = enter setpoint value in % for out of bound alarm, P21 = enter high% setpoint value in % P22 = enter low% setpoint value in % for in bound alarm, P21 = enter low% setpoint value in % P22 = enter high% setpoint value in % relay delay set (1-999 sec), P23 reset select, P24 = 0 / auto = 1 / manual PL-509 12

ANCILLARY FUNCTIONS DAMPING ma output damping adjust (typical value, 1-50), P85 display damping adjust (typical value, 1-50), P86 PARAMETER LIST P- 1 security, reference = 500 ƒ P- 2 0% calibration / 4 ma (Vsens = 0-7.3 V) ƒ=0.50 P- 3 100% calibration / 20 ma (Vsens = 0.2-7.5 V) ƒ=2.50 P-10 relay 1, operation: 0 = disabled ƒ 1 = enabled P-11 relay 1, high alarm setpoint (0 = disabled,1 to 100%) ƒ = 80 P-12 relay 1, low alarm setpoint (0 = disabled,1 to 100%) ƒ = 20 P-13 relay 1, delay (1 ƒ to 999 sec) P-14 relay 1, latch: 0 = auto reset ƒ 1 = manual reset P-20 relay 2, operation: 0 = disabled ƒ 1 = enabled P-21 ƒ= 70 relay 2, high alarm setpoint (0 = disabled, 1 to 100%) P-22 relay 2, low alarm setpoint (0 = disabled, 1 to 100%) ƒ = 30 P-23 relay 2, delay (1 ƒ to 999 sec) P-24 relay 2, latch: 0 = auto reset ƒ 1 = manual reset P-80 start delay (1 to 999 sec) ƒ=10 P-85 damping, ma out (1 ƒ to 999) P-86 damping, display (1 ƒ to 999) P-90 software revision number P-99 reset: 0 = normal ƒ 9 = reset ƒ factory setting accessible only if relay operation function is enabled PL-509 13

SECURITY ALTERATION To Enable Security: security disabled, programming access granted reference value enable code security enabled, programming access denied To Disable Security: security enabled, programming access denied reference value disable code security disabled, programming access granted MAINTENANCE CU-02 requires no maintenance or cleaning. PL-509 14

Siemens Milltronics Process Instruments Inc. 2001 Subject to change without prior notice *7ml19981EY01*