P-881 r HP KD Series DECEMBER 2015

Similar documents
LIST PRICES 1/2-6 HP "KOMPACT" CONDENSING UNITS

Apex Packaged Refrigeration System

Installation and Operations Manual

Kramersaver Air Cooled Condensing Units

Refrigeration eration System

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

ThermoSaver TM Hot Gas Defrost System

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

2018 Canadian Price List

LOW PROFILE UNIT COOLER

Condensing Unit Installation and Operating Instructions

horizontal air discharge outdoor discus condensing unit

Super-Flo Low Profile Unit Cooler

Condensing Unit Installation and Operating Instructions

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

LOW PROFILE UNIT COOLER

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Installation and Service Manual. In-Floor Warming Module external desuperheater for 3rd party air source heat pumps

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

InstructIon Manual KrEs EQuIPMEnt stands

Air-Cooled Condensing Units with Compact Screw Compressors

TL-105 COLUMN HEATER

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Horizontal Bottle Cooler Installation and Operation Manual

INSTALLATION AND OPERATING MANUAL

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

ENGINEERING SPECIFICATIONS

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

SPECTRACOOL Air Conditioner. N17 Model INSTRUCTION MANUAL. Rev. G 2015 Pentair Equipment Protection P/N

MAINTENANCE MANUAL ER ER electric reefer solutions th St., SW Byron Center, MI

O W N E R S M A N U A L

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Air Pump Up to 800 gallons

MACH N-407 Heat Pump Air-Cooled Chiller

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Compressed Air Dryer

INSTRUCTIONS! DO NOT DISCARD!

14+ SEER R-410a AIR CONDITIONERS. Aluminum Coil Series. Efficiencies up to 14+ SEER/12 EER. Nominal Sizes Ton. Capacities 16.

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Installation, Operation & Service Manual

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

OPERATION & INSTALLATION MANUAL

3-22 HP CONDENSING UNITS Technical Guide

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Operation Manual & Parts List. Slide Top Coolers Manufacture date beginning in 2009 and prior to March 27, 2017*

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

DOM MODEL SERIAL NUMBER VOLTAGE/HERTZ/PHASE

Model R060 Installation - Operation Manual

INSTALLATION INSTRUCTIONS

Installation & Operation Manual Ice Cream Freezers

INSTALLATION AND OPERATING MANUAL

Commercial High-Efficiency Condensing Units

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

M3050 Detector Operator s Manual

Panel Mounted Heat Exchangers by Dantherm, Inc.

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

INSTRUCTIONS! DO NOT DISCARD!

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS

OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING MANUAL

C13-Series Engineering Guide

MAINTENANCE MANUAL ER ER electric reefer solutions th St., SW Byron Center, MI

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

Product Specifications Warning Light Control Cabinet

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Operation Manual and Parts Directory

Installation & Maintenance Instructions

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Duct Mount. Installation Instructions

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. D 2015 Pentair Equipment Protection P/N

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

REFRIGERATED RECIRCULATORY COOLER

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

Blade Series Heat Exchanger Operation and Installation

MODELS B1PA024, 030 AND 036

Operation Manual and Parts Directory

We maintain stock in many of our most popular models for immediate shipment.

OPERATING INSTRUCTIONS

MAC N-407 Air-Cooled Chiller

Drain Cooler Water tempering device

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

The Glass Sentry line of anti-sweat heater controls is designed to conserve the electricity consumption of the heater

Transcription:

LIST PRICE SHEET P-881 r1 3-22 HP KD Series DECEMBER 2015 LIST PRICES 3-22 HP KD Series CONDENSING UNITS ALL PRODUCTS, EXCEPT SURFACE COILS AND PARTS, ARE SHIPPED F.O.B. POINT OF SHIPMENT WITH FULL FREIGHT ALLOWED ON SINGLE ORDERS WITH A NET PRICE VALUE OF $7000.00 OR MORE, WITHIN THE CONTINENTAL USA (EXCLUDING ALASKA AND HAWAII). ANY ADDITIONAL COSTS INCURRED FOR SPECIAL ROUTING AND HANDLING REQUESTS WILL BE INVOICED. PAGE DESCRIPTION 2 KD SERIES PRODUCT DESCRIPTION, NOMENCLATURE, AND LIST PRICES 3 OPTIONAL COMPONENTS 4 ELECTRIC DEFROST KIT DESCRIPTION 5 ELECTRIC DEFROST KIT LIST PRICES 6-7 BLANK NOTES PAGES BACK COVER TERMS & CONDITIONS INDEX Due to ongoing product development, specification and prices are subject to change without notice. TELEPHONE (770) 788-5800 FAX ORDER HOTLINE (770) 788-5820 Call or email us for help with replacement parts at: parts@htpgusa.com Visit us on the web at: http://kramer.htpgusa.com

KD-SERIES AIR COOLED CONDENSING UNITS 3 HP THRU 22 H.P. Standard Features (all models): Copeland Discus or Scroll Compressor Large Electrical Control Panel with Main Power Block Compressor Contactor and Control Circuit Fuses High-Low Pressure and Oil Pressure Controls Suction and Discharge Service Valves Discharge Vibrasorber NOMENCLATURE Pre-bent Heavy Wall Copper Tubing, eliminating many joints KL D 5 M 44 - E High Capacity Receiver with Isolation Valves and Pressure Relief E = 208-230/3, G = 460/3, J=575/3 High efficiency Condenser with separate Sub-cooling Circuit Heavy duty, PSC, Ball Bearing Condenser Fan Motors Compressor Head Cooling Fan (when required) Heavy gauge, raised galvanized Steel Base UL and CUL listed 44 = R-404A / 507 M = Medium Temp (-10 F to +45 F) Additional Features on KC models: H = High Temp (+10 F to +55 F) Outdoor Weatherproof Housing L = Low Temp (0 F to -40 F) Crankcase Heater 460V to 230V Control Circuit Transformer on 460V units Nominal Horsepower Suction Line Vibrasorber, Suction Filter piped to the outside of unit Liquid Line Filter/Drier and Sight Glass piped to the outside of unit D = Copeland Discus Additional Features on KL models: O = Copeland Scroll Flooded Head Pressure Control factory installed Optional Features: KC* = Outdoor models Options listed on page 3. Electric defrost kits on pages 4 & 5 KL* = Outdoor with flooded control Other Compressors available KS* = Outdoor with Saver option For R507 models, use equivalent R404A model prices KE* = Indoor models DISCUS CONDENSING UNITS REFR. NOM "KCD" Outdoor Models "KLD" Flooded "KED" Indoor Models 4 YR. COMP ECM TYPE H.P. MODEL 208/230V/3 460V/3 575V/3 MODEL 208/230V/3 460V/3 575V/3 MODEL 208/230V/3 460V/3 575V/3 WARRANTY ADDER 5 KCD5M44 $20,533 $21,802 $22,245 KLD5M44 $20,883 $22,152 $22,595 KED5M44 $18,774 $20,229 $20,672 $454 NET $461 MED. 6 KCD6M44 25,638 27,392 27,944 KLD6M44 25,988 27,742 28,294 KED6M44 20,637 22,340 22,879 550 NET 922 & 7.5 KCD7M44 26,056 27,813 28,367 KLD7M44 26,406 28,163 28,717 KED7M44 24,116 26,074 26,616 558 NET 922 HIGH 7.5 KCD8M44 29,354 31,039 31,679 KLD8M44 29,704 31,389 32,029 KED8M44 28,361 30,300 30,928 558 NET 922 TEMP. 10 KCD10M44 31,567 32,246 32,930 KLD10M44 31,917 32,596 33,280 KED10M44 30,245 31,014 31,685 721 NET 922 R-404A 12 KCD12M44 34,051 33,995 N/A KLD12M44 34,401 34,345 N/A KED12M44 32,694 32,637 N/A 865 NET 922 15 KCD15M44 35,673 36,702 37,445 KLD15M44 36,023 37,052 37,795 KED15M44 34,347 35,551 36,279 1,116 NET 922 5 KCD3L44 20,006 21,460 21,863 KLD3L44 20,356 21,810 22,213 KED3L44 18,868 20,634 21,057 306 NET 461 4 KCD4L44 21,987 23,850 24,313 KLD4L44 22,337 24,200 24,663 KED4L44 20,696 22,891 23,349 454 NET 461 5 KCD5L44 22,437 24,179 24,666 KLD5L44 22,787 24,529 25,016 KED5L44 21,255 23,297 23,776 454 NET 461 LOW 6 KCD6L44 24,573 26,263 26,779 KLD6L44 24,923 26,613 27,129 KED6L44 22,943 24,864 25,370 550 NET 461 TEMP. 7.5 KCD8L44 27,606 29,274 29,872 KLD8L44 27,956 29,624 30,222 KED8L44 26,273 28,183 28,770 558 NET 922 R-404A 9 KCD9L44 30,778 32,784 33,440 KLD9L44 31,128 33,134 33,790 KED9L44 28,939 31,209 31,854 721 NET 922 10 KCD10L44 33,543 34,501 35,188 KLD10L44 33,893 34,851 35,538 KED10L44 31,667 32,741 33,418 821 NET 922 12 KCD12L44 34,286 35,005 35,716 KLD12L44 34,636 35,355 36,066 KED12L44 32,259 33,081 33,780 865 NET 922 15 KCD15L44 35,873 36,632 37,409 KLD15L44 36,223 36,982 37,759 KED15L44 34,063 34,931 35,695 1,116 NET 922 22 KCD22L44 40,824 41,598 42,450 KLD22L44 41,174 41,948 42,800 KED22L44 39,555 40,428 40,885 1,382 NET 922 *REF NOM "KCO" Outdoor Models "KLO" Flooded "KEO" Indoor Models 4 YR. COMP ECM TYPE H.P. MODEL 230/3 230/1 460/3 MODEL 230/3 230/1 460/3 MODEL 230/3 230/1 460/3 WARRANTY ADDER Med. Temp R404A Low Temp R404A SCROLL CONDENSING UNITS 7.0 KCO7M44 $22,540 N/A $23,004 KLO7M44 $22,890 N/A $23,354 KEO7M44 $23,121 N/A $23,731 $550 NET 922 8.0 KCO8M44 27,695 N/A 29,330 KLO8M44 28,045 N/A 29,680 KEO8M44 27,700 N/A 29,703 550 NET 922 10.0 KCO10M44 30,971 N/A 31,708 KLO10M44 31,321 N/A 32,058 KEO10M44 30,272 N/A 31,139 558 NET 922 13.0 KCO13M44 33,107 N/A 33,307 KLO13M44 34,051 N/A 34,251 KEO13M44 33,050 N/A 34,052 558 NET 922 8.0 KCO8L44 21,149 N/A 22,455 KLO8L44 21,499 N/A 22,805 KEO8L44 20,982 N/A 22,636 721 NET 922 10.0 KCO10L44 25,823 N/A 27,363 KLO10L44 26,173 N/A 27,713 KEO10L44 26,364 N/A 28,316 865 NET 922 13.0 KCO13L44 29,537 N/A 30,314 KLO13L44 30,481 N/A 31,258 KEO13L44 29,739 N/A 30,712 1,086 NET 922 ECM Adder = Additional list price to order optional single speed ECM condenser fan motors. Not available for 460V. Page 2

OPTION H.P. OUTDOOR OUTDOOR INDOOR NUMBER RANGE "KC" "KL" or "KS" "KE" BKR-2 3-6 $367 $367 $367 MAIN CIRCUIT BREAKER - In lieu of power block BKR-3 7-10 550 550 550 BKR-4 12-22 792 792 792 DEFROST OPTIONS All All SEE PAGE 4 & 5 CRANKCASE HEATER CCH-2 3-6 STD STD 297 CCH-3 7-22 STD STD 356 LIQUID LINE COMPONENTS LK-4 3-8 582 Filter drier, sightglass/moisture indicator & piping LK-5 9-10 STD STD 784 $467 List Add for Replaceable Core Liquid Filter Drier LK-6 12-22 984 SUCTION LINE COMPONENTS SK-5 3-8 792 Vibrasorber, filter and piping SK-6 9-10 STD STD 1,175 $451 List Add for Replaceable Core Suction Filter SK-7 12-22 1,625 SUCTION LINE ACCUMULATOR ASK-4 3-8 754 754 754 (KE units must add suction line kit.) ASK-5 9-10 1,109 1,109 1,109 ASK-6 12-22 2,318 2,318 2,318 OS-1 3-6 1,285 1,285 1,285 OIL SEPARATOR OS-2 7-10 1,369 1,369 1,369 OS-3 12-22 1,609 1,609 1,609 FAN CYCLE CONTROL - 230V FC-2 6-22 398 398 398 FAN CYCLE CONTROL - 460V FC-4 6-22 433 433 433 Not avail. on 3 thru 6L44, L22 LOW AMBIENT FLOODED CONTROL FLD-F 3-22 944 STD 944 OVERSIZED RECIEVER - upright 96 lbs. (Std for 15H/M and 22L) OSR-3 2 Fan K-Series ONLY 1,245 1,245 1,245 OVERSIZED RECIEVER - upright 108 lbs. OSR-4 15 H/M and 22L ONLY 709 709 709 HEATED AND INSULATED RECEIVER HIR 3-22 746 746 746 SPRING LOADED RELIEF VALVE RV 3-22 287 287 287 FLEXIBLE CONTROL HOSES FLX 3-22 274 274 274 STAINLESS STEEL BRAIDED HOSES SSH 3-22 356 356 356 ELECTRONIC OIL PRESSURE CONTROL SOPC 3-22 782 782 782 UNL-1 1,714 1,714 1,714 COMPRESSOR UNLOADING UNL-2* All 1,995 1,995 1,995 PUMPDOWN SWITCH PDS 3-22 311 311 311 TWO-TIERED STACKING OPTION - 1 FAN 11639400 All 3,152 3,152 3,152 TWO-TIERED STACKING OPTION - 2 FAN 11639600 All 5,057 5,057 5,057 CURRENT SENSING RELAY CSR All 710 710 710 OH-1 3-6 2,144 OUTDOOR HOUSING OH-2 7-10 STD STD 2,588 OH-3 12-22 3,236 CRANKASE PRESSURE REGULATOR (Mounted) 3-5 388 388 388 6-9 561 561 561 10-15 1,587 1,587 1,587 22 2,530 2,530 2,530 OPTION NO. HP 230V 460V THROUGH THE DOOR NFD-2 3-10 1,492 1,734 NON-FUSED DISCONNECT SWITCH NFD-3 12-22 1,668 1,940 EXTERNAL FUSED DISCONNECT SHIPPED LOOSE ONLY! LIQUID LINE SOLENOID OPTIONS OPTION H.P. OUTDOOR OUTDOOR INDOOR NUMBER RANGE "KC" "KL" or "KS" "KE" EFDL-2 (230V) 3-6 $867 $867 $867 EFDL-3 (230V) 7-10 1,020 1,020 1,020 EFDL-4 (230V) 12-22 2,032 2,032 2,032 EFDL-2 (460V) 3-6 1,047 1,047 1,047 EFDL-3 (460V) 7-10 1,204 1,204 1,204 EFDL-4 (460V) 12-22 2,231 2,231 2,231 LLS-1 3 270 270 270 LLS-2 4-8 302 302 302 LLS-3 9-10 437 437 437 LLS-4 12-15 540 540 540 LLS-5 22 689 689 689 MECHANICAL ROOM THERMOSTAT (A19AAA) 204464001 5-15 274 274 274 ELECTRONIC ROOM THERMOSTAT (A419ABC-1C) 204464206 5-15 353 353 353 SEE 1/4 thru 3 TONS 320 320 320 EXPANSION VALVE (LOOSE) BALANCED PORT UNIT 4 thru 9 TONS 409 409 409 COOLER 10 thru 30 TONS 712 712 712 TXV 1/4 thru 3 TONS 362 362 362 EXPANSION VALVE (MTD.) BALANCED PORT SELECTION 4 thru 9 TONS 638 638 638 CHART 10 thru 30 TONS 1,054 1,054 1,054 SNOWGUARDS / HAIL GUARDS OPTIONS * Available only on 3D and 4D Discus compressors SHIPPED LOOSE FOR FIELD INSTALLATION FACTORY INSTALLED OPTIONS CPR VALVE MOUNTED FIELD INSTALLED OPTIONS 1 FAN 897 897 N/A 2 FAN SMALL 1,226 1,226 N/A 2 FAN TALL 1,374 1,374 N/A Page 3

ELECTRIC DEFROST KIT COMPONENTS Kramer's Electric Defrost Systems provide unique features that other defrost systems lack. These energy saving features are as follows: The auxiliary switch on 3 phase systems and block-out relays on 1 phase systems prevents the defrost heaters from energizing when the compressor is in operation. This features holds the maximum amp draw to the largest single load that the system will draw, and therefore reduces the electrical service requirement to the condensing unit. On multiple evaporator systems, individual defrost contactors are used in conjunction with sequencing relays* to allow each evaporator to terminate defrost independently. This efficient method of defrost saves electricity, and reduces the potential of overheating and steaming the evaporators. In addition, the amount of heat added to the room is kept to a minimum, reducing the run time of the condensing unit. KIT NUMBER TIMER AUXILIARY SWITCH BLOCK-OUT RELAY DEFROST HEATER CONTACTOR (1) FAN CONTACTOR ED-5 1 1-15A ED-6 1 1-20A ED-7 1 1-25A ED-10 1 1-30A ED-210 1 1-30A ED-11 1 1 1-30A ED-211 1 1 1-30A ED-12 1 1 1-30A 1-25A ED-13 1 1 1-50A TIMER ED-213 1 1 1-50A Initiates the defrost cycle. Also used as over ride protection ED-14 1 1 1-50A 1-25A for defrost termination. ED-15 1 1 2-75A ED-16 1 1 2-75A 1-25A AUXILIARY SWITCH ED-17 1 1 1-15A 1-25A Mounted on the compressor contactor, it prevents the ED-18 1 1 1-20A 1-20A defrost contactor from operating whenever the compressor ED-20 1 1-30A 2 is energized. ED-21 1 1 2-15A 2 ED-22 1 1 2-15A 1-25A 2 BLOCK-OUT RELAY ED-23 1 1 2-25A 2 Serves the same function as auxiliary switch, except used ED-24 1 1 2-25A 1-25A 2 when defrost contactor is not required (single phase only). ED-25 1 1 2-50A 2 ED-26 1 1 2-50A 1-25A 2 FAN CONTACTOR ED-27 1 1 2-75A 2 Used with 460V motors or when 230V motors are wired ED-28 1 1 2-75A 1-25A 2 for 3 phase power. ED-30 1 1-30A 3 ED-31 1 1 3-10A 3 DEFROST CONTACTOR ED-32 1 1 3-10A 1-25A 3 Carries amperage load for heaters. Contactor selection is ED-33 1 1 3-15A 3 based on the maximum resistive load rating of the contactor. ED-34 1 1 3-15A 1-25A 3 ED-35 1 1 3-30A 3 SEQUENCING RELAYS ED-36 1 1 3-30A 1-25A 3 Provides interconnection of multiple unit coolers on a single ED-37 1 1 3-75A 3 system so that each unit cooler is allowed to individually ED-38 1 1 3-75A 1-40A 3 terminate defrost on temperature. * Except for ED-210, ED-211, ED-213 Heater contactor amperage is based on its resistive rating. Fan motor contactor amperage is based on its inductive rating. E D 1 2 - A 2 - FB SEQUENCIN G RELAY ELECTRIC DEFROST KIT NOMENCLATURE SUB-CIRCUIT FUSE BLOCKS (USE "XX" WHEN OPTION IS NOT ORDERED) DEFROST HEATER VOLTAGE (2 = 208-230V., 4 = 460V.) DEFROST HEATER PHASE (1 or 3) A = 1 PHASE FAN MOTORS, 1 PPHASE HEATERS B = 1 PHASE FAN MOTORS, 3 PHASE HEATERS C = 3 PHASE FAN MOTORS, 3 PHASE HEATERS DEFROST KIT IDENTIFIER EVAPORATOR QUANTITY (1, 2, or 3 per system) KIT DESIGNATOR Page 4

QTY OF UNIT COOLERS DESCRIPTION ELECTRIC DEFROST PROVISIONS DEFROST KIT NUMBER LIST PRICE 1 PH. FANS 1 PH. FANS 230 V. 460 V. SUB-CIRC. LOOSE OR 1 PH. HTRS 3 PH. HTRS 3 PH. FANS 3 PH. FANS FUSE BLOCKS MOUNTED 3 PH. HTRS 3 PH. HTRS (LESS FUSES) DEFROST KITS WHEN THE EVAPORATOR FAN MOTORS ARE WIRED FOR 230/1. Up to 15 Amps Heater (w/ relay) ED5-A2-XX N/A N/A N/A $642 N/A ONE 20 Amps Heater (w/ relay) ED6-A2-XX N/A N/A N/A 642 N/A UNIT 25 Amps Heater (w/ relay) ED7-A2-XX N/A N/A N/A 642 N/A COOLER Up to 30 Amps Heater (w/ relay) ED10-A2-XX N/A N/A N/A 642 N/A PER 30 Amps - Heater (w/ contactors) N/A ED11-B2-XX N/A N/A 642 $160 SYSTEM 50 Amps - Heater ED13-A2-XX ED13-B2-XX N/A N/A 1,246 160 75 Amps Heater ED15-A2-XX ED15-B2-XX N/A N/A 1,910 195 Up to 30 Amps Heater (w/ relay) ED210-A2-XX N/A N/A N/A 642 N/A 30 Amps Heater ED211-A2-XX ED211-B2-XX N/A N/A 642 160 TWO 50 Amps Heater ED213-A2-XX ED213-B2-XX N/A N/A 1,246 195 UNIT Up to 15 Amps Heaters each (w/ relays) ED20-A2-XX N/A N/A N/A 1,779 N/A COOLERS 15 Amps Heaters each ED21-A2-XX ED21-B2-XX N/A N/A 1,779 288 PER 25 Amps Heaters each (w/ relays) ED23-A2-XX N/A N/A N/A 1,827 288 SYSTEM 25 Amps Heaters each (w/ contactors) N/A ED23-B2-XX N/A N/A 1,827 288 50 Amps Heaters each ED25-A2-XX ED25-B2-XX N/A N/A 2,050 288 75 Amps Heaters each ED27-A2-XX ED27-B2-XX N/A N/A 2,791 375 Up to 10 Amps Heaters each (w/ relays) ED30-A2-XX N/A N/A N/A 2,422 N/A THREE 16 Amps Heaters each (w/ relays) ED31-A2-XX N/A N/A N/A 2,422 355 UNIT 16 Amps Heaters each (w/ relays) ED33-A2-XX N/A N/A N/A 2,422 355 COOLERS 16 Amps Heaters each (w/ contactors) N/A ED33-B2-XX N/A N/A 2,422 355 PER 30 Amps Heaters each (w/ relays) ED35-A2-XX N/A N/A N/A 2,718 355 SYSTEM 30 Amps Heaters each (w/ contactors) N/A ED35-B2-XX N/A N/A 2,718 355 50 Amps Heaters each ED37-A2-XX ED37-B2-XX N/A N/A 3,089 422 DEFROST KITS WHEN THE EVAPORATOR FAN MOTORS ARE WIRED FOR 230/3, 460/3, OR 460/1. Up to 30 Amps Heater ED12-A4-XX ED12-BX-XX ED12-C2-XX ED12-C4-XX $1,299 $266 ONE UNIT 50 Amps Heater N/A ED14-BX-XX ED14-C2-XX ED14-C4-XX 1,519 266 COOLER 75 Amps Heater N/A N/A ED16-C2-XX ED16-C4-XX 2,089 310 15 Amps Heater ED17-A2-XX ED17-B2-XX N/A N/A 1,299 195 TWO Up to 15 Amps Heaters per Unit Cooler N/A ED22-BX-XX ED22-C2-XX ED22-C4-XX 2,184 355 UNIT 25 Amps Heaters per Unit Cooler N/A ED24-BX-XX ED24-C2-XX ED24-C4-XX 2,184 355 COOLERS 50 Amps Heaters per Unit Cooler N/A ED26-BX-XX ED26-C2-XX ED26-C4-XX 2,302 406 75 Amps Heaters per Unit Cooler N/A N/A ED28-C2-XX N/A 2,973 494 THREE Up to 10 Amps Heaters per Unit Cooler N/A ED32-BX-XX ED32-C2-XX ED32-C4-XX 2,788 472 UNIT 16 Amps Heaters per Unit Cooler N/A ED34-BX-XX ED34-C2-XX ED34-C4-XX 2,788 472 COOLERS 30 Amps Heaters per Unit Cooler N/A ED36-BX-XX ED36-C2-XX ED36-C4-XX 3,448 472 50 Amps Heaters per Unit Cooler N/A ED38-BX-XX ED38-C2-XX ED38-C4-XX 3,829 565 Replace "XX" with "FB" when ordering the sub-circuit fuse block option. For description of "ED" kit nomenclature see page 4. Sub-circuit fuse block price includes fuse blocks installed in the condensing unit, less fuses, for evaporator(s) motors and defrost heaters. Sub-circuit fusing option is not available for 1/2 to 6 HP models due to space limitations in the control panel. * Add "FB" suffix to ED kit part number when pricing sub-circuit fuse block option. Page 5

NOTES Page 6

NOTES Page 7

P-881 r1 1. Applicable Law and Terms of Sale: All orders shall be subject to the following terms and conditions notwithstanding any additional or contrary printed terms and conditions of Buyer. Such additional or contrary terms shall not bind Seller unless accepted in writing even though such terms do not materially alter the terms hereof. No oral statements, warranties, stipulations, representations or terms shall have any binding effect or be any part of the contract whatsoever. PRINCIPAL TERMS AND CONDITIONS OF SALE 2. Orders: All orders must be in writing and will be binding when our order acknowledgment is mailed. Orders are accepted subject to strikes, fires, accidents, and other causes beyond our reasonable control. Acceptance of your order is conditioned upon an agreement to hold us harmless by reason of delivery delays. Minimum order charge is $50.00. 3. Prices: Prices are subject to change without notice, and all quotations, unless otherwise specified, are binding only for immediate acceptance. Prices are based on material made to Seller's standard tolerances, unless otherwise specified. 4. Freight: All products are shipped FOB Point of Shipment. Routing and selection of carrier will be made by Seller. For special routing requests Buyer will bear all additional costs for such routing. Equipment is shipped at Buyer's risk. Buyer should examine equipment before signing transportation receipt. If equipment is received damaged or if quantity received does not match freight bill, the Buyer should require agent to so indicate on freight bill and immediately file a damage/missing claim. Our liability ceases upon delivery of equipment in good order to the freight carrier. Full freight is allowed on shipments with a net price value of $7000.00 or more, except surface coils and parts within the continental U.S.A. excluding Alaska and Hawaii. 5. Taxes: Any sales, use, excise, or similar tax payable by Seller which is or may be imposed by any taxing authority upon manufacture, sale or delivery of goods covered by any order or any increase in rate of any such tax now in force shall be added to the sales price; if not collected at the time of payment of sales price, Buyer will hold Seller harmless. 6. Limited Warranty: Seller warrants against defect in materials and workmanship in products which it manufactures for (1) year from date of installation or up to (18) eighteen months from the date of shipment, whichever event occurs first, when properly installed and operated under normal use. This guarantee does not include any labor or other charges made outside of the Seller's factory for replacement or repair of defective parts unless specifically stated in the body of the Sellers invoice. On parts not manufactured by Seller, such as motors, controls, valves and compressors we extend to the Buyer the same warranties made to us by the manufacturer. Sellers only liability under this warranty or otherwise shall be the repair or replacement (at Seller's option) of non-conforming goods or parts. Seller assumes no liability for incidental or consequential damages such as injury to person or property, or lost profits. 7. THIS GUARANTEE SUPERSEDES AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES BY LAW OR CUSTOM, EITHER EXPRESSED OR IMPLIED INCLUDING, BUT NOT LIMITED BY THIS ENUMERATION, ANY GUARANTEE AS TO QUALITY OR FITNESS FOR ANY PAR- TICULAR PURPOSE, EXCEPT AS SET FORTH ABOVE. NO PERSON, AGENT, OR DEALER IS AUTHORIZED TO GIVE ANY WARRANTIES ON BEHALF OF SELLER NOR TO ASSUME FOR SELLER ANY OTHER LIABILITY IN CONNECTION WITH ANY OF THE SELLER'S PROD- UCTS. 8. Delivery: Seller shall not be liable for any delays in or failure of delivery due to acts of God or public authority, labor disputes, accidents, fires, floods, extreme weather conditions, failure of and delays by carriers, shortages of material, delays of a supplier, and any other cause beyond Seller's control. In no event shall Seller be liable for consequential or special damages arising our of a delay in or failure of delivery. Failure to meet estimated ship dates will not be considered sufficient cause of cancellation of orders. 9. Cancellations and Returned Goods: Permission to return any part or product must be obtained from Seller. Credits for new material accepted for return will be at the original sales price or current market price, whichever is lower, less handling and restocking charges. Buyer must prepay all transportation charges. Any costs for putting material in condition for resale will be charged to the Buyer. Shipment of material returned without factory authorization or not properly tagged with Material Return Authorization Number or not freight prepaid cannot be received by Seller. Obsolete products or material made to special order are not returnable. 10. Catalog Materials and Drawings: Seller is not responsible for typographical errors or other errors of omission in Seller's catalogs or drawings. 11. Late Charge Provision: Buyer agrees to pay a late charge of 1-1/2% per month (18% per year) for any invoice or bill not paid within (30) thirty days of the date of the billing invoice. 12. Choices of law, Disputes: This agreement and the performance of the parties hereunder shall be construed in accordance with and governed by the laws of the State of Georgia and shall be deemed made in the state. Buyer irrevocably consents to the exclusive jurisdiction of the courts of Fulton County on all matters arising out of or relating to this sale and Buyer further irrevocably consents to service of process by certified mail, return receipt requested, at Buyers address set froth in the order acknowledgement. The above terms and conditions apply to all orders placed with the Seller. Buyer acknowledges having read and understood these terms and conditions and agrees to abide by them upon placement of any order with the Seller. In the event it becomes necessary to refer the account to a collection agency or to institute legal action to obtain payment of the account, Buyer agrees to pay all reasonable attorney fees and court costs incurred by such action. 3885 Crestwood Pkwy., Ste. 500 Duluth, Georgia 30096 / TEL: (770) 788-5800 FAX: (770) 788-5820 Call or email us for help with replacement parts at: parts@htpgusa.com VISIT US ON THE WEB AT kramer.htpgusa.com