INSTALLATION FOR THERMOSTATIC VALVES

Similar documents
SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

INSTALLTION FOR THERMOSTATIC VALVES

MINIATURE THERMOSTATIC VALVE

INSTALLATION INSTRUCTIONS

1/7 INSTALLATION INSTRUCTIONS. Rough Installation

Thermostatic Concealed Shower Valve

CORALAIS BODYSPA BATH AND SHOWER FAUCET

Thermostatic Valve and Trim

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

ARIN THERMOSTATIC SHOWER SYSTEM

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION

PL-004-SS. * Proper water pressure is required for simultaneous operations

Inta City Concealed Shower Mixing Valve CT80010CP

Installation Instructions

s y ens Av Avensys FIN EST RUS SLO RUS UAE

Avensys Avensys FIN EST SLO RUS UAE

COVER PLATE GREY PLASTIC OR OPTIONAL SOLID BRASS DIAL

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

TIMES SQUARE TWO-HANDLE THERMOSTAT

Butler Mill and Brassworks Ltd. Exposed 1/2 Thermostatic Valve Installation Instructions

Enzo Concealed Shower Mixing Valve

Installation. S Series Navigator Thermostatic Mixing Valve

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

Thermostatic shower valve with 2 way diverter, brass faceplate and handles - V51

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Elite Primer Baldor Series External Pond Pump

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Avensys Avensys FIN EST SLO RUS UAE

Installation S

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Mio Concealed Shower Mixing Valve MI40010CP

Thermostatic shower valve with 3 way control, brass faceplate and handles - V52

INSTALLATION INSTRUCTIONS

Installation S

Installation S

Deluge Concealed Shower Mixing Valve DL40010CP

Telo Shower Mixing Valve TL10016CP

Installation S

Thermostatic Shower Valves Installation Guide

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions / Warranty. PuraVida 15775XX1

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

INSTALLATION INSTRUCTIONS

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

CHAMPION PUMP OWNER S MANUAL

Installation Instructions. Hansgrohe S 15721XXX

INSTALLATION INSTRUCTIONS Thermostatic Mixing Valve

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

INSTALLATION AND INSTRUCTION MANUAL

I mpo rta n t : Please re g is t e r y ou r p rod uct onli ne at www. santecfaucet. com wi thi n 30 da ys o f pu rc h as e. S an t e c reser v e s

B.I.C.A Built-In Coffee Appliance

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

Thermostatic Deck-Mounted Bathtub Mixer Installation Guide

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

Installation Guide ASME A ANSI A117.1 CUPC / IAPMO LISTED / ADA COMPLIANT. Engineering Excellence

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

Installation Guide. Engineering Excellence. Single Handle Tub & Shower Valve Set: 4010B 4011B

SMF PUMP OWNER S MANUAL

Installation Instructions. Starck

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Installation S

INSTALLATION INSTRUCTIONS

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

16 OUTDOOR MISTING FAN

WIDESPREAD KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE

Installation, Operating and Maintenance Guide

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

INSTALLATION INSTRUCTIONS

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation, Operating and Maintenance Guide

Installation & Operating Instructions

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

Installation & Operating Guide

Installation & Service Manual

Kiko Concealed Shower Mixing Valve KK80010CP

INSTALLATION INSTRUCTIONS

Series 1140 and 1141 Temperature Regulators

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

These instructions are to be left with the user

Installation Instructions

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Model H1011.8/H1011.8HPS Water Cooler

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Mounting and Operating Instructions EB 2231 EN

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

Product Description and Measurements. Thank You. Prior To Installation Steps. Waterfall Faucet Installation

Transcription:

SS-TH1000 1/2 Thermostatic Valve SS-TH3000 3/4 Thermostatic Valve SS-TH2000 1/2 Thermostatic Valve with built in volume control SS-TH4000 3/4 Thermostatic Valve with built in volume control Features: Ability to pre-select water temperature thus conserving water Paraffin wax element maintains water temperature within ± 1.8 F Compensates for water pressure fluctuations preventing scalding Safety button at 100 F prevents accidental scalding High flow rates allow for multiple shower applications Listed by IAPMO, CSA, NSF, and other municipalities Specifications: Operating pressure is 2 PSI to 72 PSI When pressure is higher than 72 PSI a pressure reducer (fitted before the valve) is required. Temperature range is 50 F to 180 F Recommended setting is 29 PSI and 149ºF Note: Note: DO NOT USE PLUMBER S PUTTY ON ANY OF THE BRASS COMPONENTS This will cause the finish to tarnish and void the warranty. A non-corrosive Alkoxy Silicone is recommended. DURING SWEATING OF LINES DO NOT OVERHEAT CASTING Overheating may cause damage to internal mechanism and void the manufacturer s warranty as well as increase the risk of scalding. COPPER ADAPTORS MAY BE REQUIRED TO COMPLETE YOUR INSTALLATION Separate wall stops/ shut off valves/ volume controls (SS-TS100 or SS-TS150 or SS-TS200) may be needed in conjunction with this valve. A thermostatic valve s only function is to mix temperature. P a g e 1

SS-TH1000 or SS-TH3000 SS-TH2000 or SS-TH4000 Parts Checklist Carefully remove all parts from the box. The following parts should be included. Description Qty 1 Face plate 1 2 Lock Ring 2 3 Black Temperature dial 1 4 Temperature control 1 handle post 5 Volume control handle 1 post 6 Temperature control 1 dome 7 Volume control dome 1 8 Black volume dial 1 9 Volume control handle 1 (representative handle) 10 Temperature handle 1 (representative handle) 11 Temperature control set 1 screw (for some models) 12 Temperature control 1 screw (for some models) 13 Dome sleeve (raw brass) 2 15 CRT506.4 cartridge 1 16 Check and integral stop 1 17 Friction ring 1 18 Thermostatic limit stop ring 1 Valve Installation 1. Flush the lines of all dirt and debris. Failure to completely flush the lines will cause valve failure and will void the manufacturer s warranty. 2. Fit the valve on the wall without removing the plastic cover on the control spindle. Turning the control spindle will change the temperature setting which is pre-calibrated at the factory. P a g e 2

3. Connect the hot water supply to the left inlet of the valve (HOT marked with RED paint) and cold supply to the right inlet (COLD marked with BLUE paint). 4. Use the plastic mud guard template (part of the package) to position the valve in the wall. This is done by checking the label on the outer template for the minimum/ maximum settings which is 1 ½ to 2 1/8 from the center of the valve inlets to the finished wall. 5. Connect the outlet pipe(s). Install tile stops/ volume controls between the thermostatic valve and each device to be operated. See diagram 4 for sample installations. Ensure bottom outlet is plugged if not being used. NOTE: Water temperature from bottom outlet will be slightly colder than water temperature from top outlet. Trim Installation 1. Screw Temperature Control Dome (6) and Volume Control Dome (7) onto valve. Volume Control Dome (7) is for valves with built-in volume controls (SS-TH2000 and SS-TH4000) and does not apply to valves with separate volume controls. Please note that the Temperature Control Dome (6) has a larger opening than the Volume Control Dome (7). 2. Secure the Thermostatic Face Plate (1) onto the valve by sliding over the Temperature Control Dome (6) and Volume Control Dome (7) 3. Screw Dome Sleeve (13) onto Temperature Control Dome (6) and Volume Control Dome (7). 4. Lock the Thermostatic Face Plate (1) securely against the wall using the Thermostatic Face Plate Lock Ring (2). 5. Ensure Temperature Limit Stop ring (18) is installed with red dot at 12 o clock position, and thermostatic handle is installed with push button at 12 o clock position. Note: If thermostatic handle is a lever handle, make sure Friction Ring (17) is installed first by sliding over the valve. Temperature Setting The delivered temperature of the valve varies depending on the temperature of the supplied hot water. The valve is factory set at a supplied temperature of 149ºF under balanced pressures. Depending on your preferred hot water temperature setting, it may be necessary to adjust the calibrations of the valve. The limit override button is preset at 100ºF and can be adjusted as described below. 1. Select 100ºF on the control handle. 2. Without turning the handle, remove the handle by unscrewing the screw and pulling off (screw may be concealed and/or fastened with set screws). 3. Use a thermometer to check the delivered temperature on one of the outlets. 4. Adjust water temperature to 100ºF by hand turning the cartridge stem slowly left or right. 5. Ensure that the temperature stop-ring in installed with red dot at 12 o clock position. P a g e 3

6. Push the handle back on the valve with the push button at the 12 o clock position. Removal and Maintenance of Cartridge This thermostatic valve has screens to prevent dirt and unwanted particles from damaging the valve. Clogged screens can cause reduced flow and inefficient temperature mixture by the valve. You can easily clean the screens by following the instructions below. 1. Unscrew the two screws on the cover faceplate and remove the plate. 2. Shut off the water inlets by tightening the two screws at the two check stop valves. 3. Remove the handle by unscrewing the screw and pulling off (screw may be concealed and/or fastened with set screws). 4. Pull off the temperature stop-ring. 5. Unscrew the cartridge with a 24 mm wrench or other adjustable wrench in a counter-clockwise position and gently pull it out. 6. Clean the screens and rinse with water. If necessary, soak in a 50/50 mix of white vinegar/ water or a de-scaling agent until all dirt is dissolved. Grease the o-rings with a silicone based grease and wipe the housing with a wet cloth before reassembling. 7. Reassemble the valve by reversing these instructions. Make sure the indentation on the shroud, the red dot on the temperature limit-ring, and push button on the handle are all in the aligned in the 12 o clock position. Note: To prevent the handle from accumulating mineral build up, which can cause the handle to lock up, the handle must be turned on an occasional basis. Troubleshooting Malfunction Cause Remedy Cannot regulate temperature Dirt in check valves Hot and cold water do not mix Water supply reversed Valve installed upside down Lack of water pressure at one of the inlets Blocked shower head Reverse hot and cold supply lines Reverse valve Correct water pressure at source Remove shower head and clean debris. If necessary, soak in a 50/50 mix of white vinegar/ water or a de-scaling P a g e 4

Water not hot enough / Water too hot Temperature selected on handle is different than actual water temperature Debris in check valves Valve not properly calibrated Water heater setting incorrect Debris in check valves Valve not properly calibrated agent until all dirt is dissolved. Calibrate valve following instructions on previous page Adjust water heater temperature setting Calibrate valve following instructions on previous page Uneven hot & cold water pressure Check and adjust water pressure for both hot & cold supply lines Handle does not turn Mineral build up Remove and clean cartridge following instructions above Low water pressure Low water pressure Check and adjust water pressure at source Leaking shower head Valve body too deep into wall Debris in cartridge Debris in check valves Blocked shower head Fault cartridge in wall stop/ volume control The measured rough in or finished wall surface is incorrect Remove and clean cartridge following instructions above Remove shower head and clean debris. If necessary, soak in a 50/50 mix of white vinegar/ water or a de-scaling agent until all dirt is dissolved. Repair or replace cartridge in wall stop/ volume control Install the proper extension kit: SS-EXT40 for ½ and ¾ valves (need to specify finish) SS-EXT50 for ½ and ¾ valves with built in wall stop/ volume control (need to specify finish) P a g e 5

P a g e 6