Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

Similar documents
Minutes Matter CALL FOR ASSISTANCE. I rest easier knowing that Edwards devices are installed throughout the Assisted Living Center that I manage.

CM800 Emergency Call System

SELECT-A-HORN/STROBE SERIES

SECTION (16140) - WIRING DEVICES

RESTROOM CONTROL KITS

TrueAlert Multi-Candela Notification Appliances

Model A1600 Series Annunciator

SECTION NURSE CALL SYSTEM

s Notification Appliances

SECTION HEALTHCARE COMMUNICATION AND MONITORING SYSTEM (NURSE CALL)

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

DISTRIBUTION PANEL BOARDS; NEW CONSTRUCTION. Subpart 1. Circuit index. All circuits in light and power

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

TrueAlert Notification Appliances

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

CX-WC SERIES RESTROOM CONTROL KITS ELECTRIFIED LOCKS, RELAYS & TIMERS BARRIER FREE RESTROOM CONTROL FEATURES DESCRIPTION APPLICATION

Field Configurable Horns and Strobes

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

CX-WC SERIES RESTROOM CONTROL KITS ELECTRIFIED LOCKS, RELAYS & TIMERS BARRIER FREE RESTROOM CONTROL FEATURES DESCRIPTION APPLICATION

Tek-ENTRY Vandal-Resistant Apartment Entry Systems

Temperature, Mechanical

Field Configurable Horns and Strobes

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

TrueAlert Multi-Candela Notification Appliances

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

Hi-Tech, Low Cost Stanley Solutions. Product Brochure

Addressable Fire Alarm Control Panel

POWER SOURCES MODEL NO. DESCRIPTION PRICE

ISOLATED POWER ACCESSORIES

ARCHITECTS & ENGINEERS SPECIFICATIONS ACS INTERCOM BUILDING ENTRY SYSTEM VERSION 6.0 AUGUST 1999

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

Conformity Approvals Rated insulation voltage Ui

Tek-ENTRY Apartment Entry Systems

Potter Wall Mount Select-A-Strobe

Electronic Control Pushbutton

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

BEHIND THE PANEL AML s simple, cost effective design provides many behind-panel benefits for the designer and installer/user.

Commercial and Light Industrial Fire Alarm Control Panel

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

good things in small packages

1.5 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: For nurse-call equipment to include in emergency, operation, and maintenance manuals.

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

Specification/ Data Sheet

SECTION FIRE ALARM SYSTEMS

Model A1700 Series Annunciator

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560

SIMPLEX WEATHERPROOF CONTROL PANELS

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

TrueAlert Addressable Notification Appliances

Communication Products

SECTION DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

LifeAlarm Fire Alarm Control Panels

SOUTHVIEW MEDICAL CENTER

High performance general illumination

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

SENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification

St. Vincent s Health System Page 1 of 6

LifeAlarm Fire Alarm Controls

Tek-COM Home Intercom System. Specification Sheets Submittal Package as of 8/06/2002. Website:

Signaling Lights. SLC30-IPS Series Panel Mounted Annunciators

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

SECTION AUTOMATIC TRANSFER SWITCHES

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

Tek-ENTRY Vandal-Resistant Apartment Entry Systems. Specification Sheets Submittal Package. as of 03/24/2009. Website:

L-Series, Emergency Communication Devices

NURSE CALL SYSTEM SPECIFICATION

Viking Installation Guide

A simple communication system sa medical and commercial f ields.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

INFRARED ZONE HEATING SYSTEM

Exit Switches 410 & 420 SERIES MODELS SPECIFICATIONS HOW TO ORDER 1 SPECIFY MODEL 2 SPECIFY FINISHES 3 SPECIFY OPTIONS

Wheelock RSS & RSSP Series

Genesis LED G1 Series

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

ESP TECHNOLOGIES LIMITED

PATIENT CARE Single Wardrobe, Open Single Wardrobe, Door Double Wardrobe, Open. Double Wardrobe, Doors (shown) 5232 (reversed)

Monitoring Devices 11/1

L-Series, Indoor Strobes and Horn Strobes

SUNS International LLC. Presentation

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

3099-2E. Technical Information

Beacon 110 Gas Monitor Operator s Manual

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

INFRARED ZONE HEATING SYSTEM

AL800ULADA. NAC Power Extender. Installation Guide

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

STANDARD FEATURES SPECIFICATIONS

Mar H: SUPPLEMENTAL FIRE DETECTION AND ALARM (16720-H)

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Transcription:

Mounting Plate 147-10 > Momentary switch push button > Stainless steel faceplate The Edwards Cat. No. 147-10 Mounting Plate when used with the catalog series 620 Push Buttons (page 10-9) forms a convenient station that provides emergency call activation. Designed for single gang mounting. Used as a switch plate outside hotel rooms accessible to the handicapped. Supplied as part of the 7005-G5 Hotel Room Annunciator (page 14-4). 2 3/4" (79mm) " 14-8

Bedside Stations 7302 Series > 3 maintained contacts > Stainless steel face plate > "Emergency" engraved units available > 3 amps at 125V AC; 0.5 amps at 125V DC The Edwards Bedside Station provides emergency call activation. Calls are placed by pulling one of the attached 6 foot (1.83m) cords. Cords are replaceable with a standard nylon cord. Designed for either flush or surface mounting. Unit fits in a standard single-gang electrical box and plaster cover. For surface mounting, use a Wiremold surface box. All boxes must have a minimum depth of 1 3/4" (44mm). Boxes and covers not supplied. Use in private and semi-private hospital rooms. Use in emergency stations and patient bath and toilet areas, hospitals, public restrooms, and handicapped areas. 2 3/4" (70mm) 7/8" (22mm) 1 3/8" (35mm) Cat. No. 7302A 7302AE Description Double cord Double cord, face plate engraved "Emergency" 14-14

Horn/Strobe 6536-G5 The Edwards 6536-G5 Horn/Strobe is an audible/visual signaling device that may be used in a variety of system configurations including call for assistance applications. Designed for installation in a single gang 2" (51mm) x 4" (102mm) box. Use in health care facilities, public rest-rooms, and handicapped areas. Supplied as part of the 6538-G5 Call for Assistance Package (pg. 14-2) and the 7005-G5 Hotel Room Annunciator (pg. 14-4). > High intensity strobe > Neutral white color AGENCY APPROVALS > UL 1638 Listed > Horn: 82 dba at 10 feet (3.05m) > 24V 50/60 Hz or 24V DC > Current draw: 175 ma at 24V 50/ 60 Hz; 125mA at 24V DC > Strobe output: 50 cd on-axis 4 9/16" (116mm) 2 1/4" (57mm) 13/16" (20mm) 14-9

Pull Cord Station 6537 > Double pole single throw switch > Stainless steel face plate > 3 amps at 125V AC; 0.5 amps at 125V DC The Edwards 6537 pull cord station provides emergency call activation. The call may be reset at the initiating station. Cords are replaceable with a standard nylon cord. Use in health care facilities, public rest-rooms, and handicapped areas. Supplied as part of the 6538-G5 and 7008B-N5 Call for Assistance package (pages 14-2 and 14-6). 2 3/4" (70mm) 14-10

Call For Assistance Kit Meets ADA requirements 6538-G5 > Double pole single throw switch > High intensity strobe > Neutral white color > Fits single gang box AGENCY APPROVALS > Transformer and horn/strobe UL Listed > Horn/strobe UL 1638 Listed > Meets ADA requirments > Transformer primary: 120V AC; secondary: 24V AC > Horn/strobe current draw: 175 ma at 24V 50/60 Hz and 125 ma at 24V DC > Strobe output: 50 cd on-axis The Edwards 6538-G5 Call For Assistance system is designed for areas where a call-for-help or an emergency switch is required. The kit consists of a Cat. No. 6536-G5 horn/strobe for audible and visual signaling, a Cat. No. 6537 emergency pull cord station, and a Cat. No. 592 transformer. Each component may also be ordered individually. See the applicable component catalog page for a detailed description of that component. Use in health care facilities, public rest-rooms, and handicapped areas. 6536-G5 Horn/Strobe The Cat. No. 6536-G5 Horn/Strobe is designed for use in a single gang 2" (51mm) x 4" (102) box located over the door. Each unit contains an audible horn signal which generates an 82 dba sound pressure level at 10 ft. and a high intensity strobe. See page 14-9. 592 Transformer The Edwards Cat. No. 592 transformer is used to power the horn/ strobe. It is equipped with a grounding wire and is suitable for installation in both plastic and metal boxes. See page 11-2. 6537 Pull Cord Stations The Cat. No. 6537 pull cord station provides emergency call activation and reset. It has a stainless steel face plate with a DPST switch. See page 14-10. 14-2

TECHNICAL INFORMATION Additional Cat. No. 6537 pull cord switch (purchased separately) org Electrical box for 6537 KEY: Audible alarm symbol Strobe symbol 6537 Pull Cord Switch Electrical box for 6537 592 Transformer org 6536-G5 Horn/Strobe wht To 120V AC power source 120V 60 Hz 24V 20VA Electrical box for 6536-G5 Horn/ Strobe red org/wht Connecting Cat. No. 6538-G5 Call for Assistance Kit 2 1/4" (57mm) 13/16" (20mm) 2 3/4" (70mm) 4 9/16" (116mm) Cat. No. 6536-G5 Cat. No. 6537 2 1/2"" (64mm) 2 1/4" (57mm) 2 1/8" (54mm) 1 1/8" (29mm) 2" (50mm) Cat. No. 592 Transformer 14-3

Hotel Room Annunciator Kit Audible and Visual Signals 7005-G5 > High intensity strobe > Neutral white color > Fits single gang box AGENCY APPROVALS > Transformer UL Listedand horn/ strobe UL Listed > Horn/strobe UL 1638 Listed > Transformer primary: 120V AC; secondary: 24V AC > Horn/strobe current draw: 175 ma at 24V 50/60 Hz; 125 ma at 24V DC > Strobe output: 50 cd on-axis The Edwards 7005-G5 Hotel Room Annunciator is for use in hotel rooms and other areas designed to accommodate those with audible, visual, or physical impairments. The kit consists of a Cat. No. 6536-G5 horn/strobe for audible and visual signaling, a Cat. No. 620 push button, a Cat. No 147-10 mounting plate, and a Cat. No. 592 transformer. Each component may also be ordered individually. See the applicable component catalog page for a detailed description of that component. Use in hotels, health care facilities, public rest-rooms, and handicapped areas. 6536-G5 Horn/Strobe The Cat. No. 6536-G5 Horn/Strobe is designed for use in a single gang 2" (51mm) x 4" (102) box located over doors. Each unit contains an audible horn signal which generates an 82 dba sound pressure level at 10 ft. and a high intensity candela strobe. See page 14-9. 592 Transformer The Edwards Cat. No. 592 transformer is used to power the horn/ strobe. It is equipped with a grounding wire and is suitable for installation in both plastic and metal boxes. See page 11-2. 620 Push Button The Cat. No. 620 push button station provides call activation when installed in the 147-10 mounting plate (page 14-9). The plate has a stainless steel face. The switch is momentary. See page 10-9. 14-4

TECHNICAL INFORMATION Additional Cat. No. 620 and 147-10 purchased separately Cat. No. 147-10 mounting plate with 620 push button Electrical box for 620 and 147-10 Electrical box for 620 and 147-10 KEY: Audible alarm symbol Strobe symbol 592 Transformer 6536-G5 Horn/Strobe To 120V AC power source 120V 60 Hz 24V210VA Electrical box for 6536-G5 Horn/ Strobe Connecting Cat. No. 7005-G5 Hotel Room Annunciator 2 1/4" (57mm) 13/16" (20mm) 2 3/4" (70mm) 4 9/16" (116mm) Cat. No. 6536-G5 Cat. No. 147-10 w/ 620 Pushbutton 2 1/2"" (64mm) 2 1/4" (57mm) 2 1/8" (54mm) 1 1/8" (29mm) 2" (50mm) Cat. No. 592 Transformer 14-5

Buzzer/Strobe 7007B-N5 The Edwards 7007B-N5 Buzzer/Strobe is an audible/visual signaling device that may be used in a variety of system configurations including call for assistance applications. Designed for installation in a single gang 2" (51mm) x 4" (102mm) box. Use in health care facilities, public rest-rooms, and handicapped areas. Supplied as part of the 7008B-N5 120 Volt Call for Assistance Kit (page 14-6). > High intensity strobe > Neutral white color AGENCY APPROVALS > UL Listed > Horn: 82 dba at 10 feet (3.05m) > Strobe: 150 candela > 120V AC > Current draw: 115 ma 4 9/16" (116mm) 2" (51mm) 13/16" (20mm) 14-11

Call For Assistance Kit Meets ADA requirements 7008B-N5 > 120V AC > Double pole single throw switch > High intensity strobe > Neutral white color > Fits single gang box AGENCY APPROVALS > UL Listed > Meets ADA requirements > Buzzer/strobe current draw: 115 ma > Strobe: 150 candela The Edwards 7008B-N5 120 volt Call For Assistance system is designed for areas where a call-for-help device is required. The kit consists of a Cat. No. 7007B-N5 buzzer/strobe for audible and visual signaling and a Cat. No. 6537 emergency pull cord station for activation. Each component may also be ordered individually. See the applicable component catalog page for a detailed description of that component. Use in health care facilities, public rest-rooms, and handicapped areas. 7007B-N5 Buzzer/Strobe The Cat. No. 7007B-N5 buzzer/strobe is designed for installation in a single gang 2" (51mm) x 4" (102mm) box located over doors. Each unit contains an audible signal which generates an 82 dba sound pressure level at 10 ft. and a high intensity 150 candela strobe. The unit draws 115 ma. See page 14-11. 6537 Pull Cord Station The Cat. No. 6537 pull cord station provides emergency call activation and reset. It has a stainless steel face plate with a DPST switch. See page 14-10. 14-6

TECHNICAL INFORMATION Additional Cat. No. 6537 pull cord switch purchased separately Electrical box for 6537 Audible alarm symbol KEY: Strobe symbol 6537 Pull cord switch Electrical box for 6537 7007B-N5 Buzzer/Strobe To 120V AC power source Electrical box for 7007B-N5 Buzzer/ Strobe Connecting Cat. No. 7008B-N5 Call for Assistance Kit 2 1/4" (57mm) 13/16" (20mm) 2 3/4" (70mm) 4 9/16" (116mm) Cat. No. 7007B-N5 Cat. No. 6537 14-7

Nurse Call Annunciators Audible and Visual Signals 7035 > 4 Bull's-eye lamps > Provides both visual and audible signals > Brushed stainless steel finish > 24V AC (Use Cat. No. 599 transformer purchased separately. See page 11-2) The Edwards 7035 Nurse Call Annunciator provides an unmistakable indication when a patient or resident calls. The bull's-eye lamps are illuminated and an internal buzzer sounds when external contacts are actuated. The silencing switch on the front of the unit is used to silence the buzzer. When the switch is in the off position, buzzer operation is prevented. The annunciator may be relamped, without tools, from the front of the unit. For flush mounting, use a standard 3 gang box (not supplied); for surface mounting, use a Wire Mold box (not supplied). For small audio/visual call and alarm systems. For use in hospital nurse stations, medical offices, corridors, and treatment rooms. 6 3/8" (162mm) 3/8" (10mm) 1 3/4" (42mm) Silencing Switch 14-12

Nurse Call Annunciators Audible and Visual Signals ADA/HOSPITAL SIGNALING DEVICES 7042 The Edwards 7042 Nurse Call Annunciator provides easy to read indications. Partitioned lamp and socket assemblies prevent crosslighting of the translucent indicator windows. Each window is individually back lighted. A gentle tone buzzer, with a silencing switch, provides an audible indication. When the switch is in the off position, buzzer operation is prevented. Flush or surface mount units for large audio/visual call and alarm systems. For use at hospital nurse stations and other centralized locations. Wall box is sold separately. > 12, 24 and 50 window sizes > Provides both visual and audible signals > Gray enamel finish with hinged door > 24V AC (Use Cat. No. 88-50 or 88-100 transformers. See page 11-5) W A 1/4" (6mm) 3" (76mm) H B Silencing Switch Surface Wall Box Arrangements Dimensions Cat. No. Wall Box Indications Down Across Size No. W H A B 7042-12 Flush - P-029566 12 4 3 1 13 1/2" 12 1/4" 11 1/2" 10 1/4" Surface - P-047701-0111 (343 mm) (311 mm) (292 mm) (260 mm) 7042-24 Flush - P-029568 24 8 3 2 16 1/2" 16 1/2" 1 1 Surface - P-047701-0112 (419 mm) (419 mm) (368 mm) 368 mm) 7042-50 Flush - P-029570 50 10 5 3 19 1/2" 20 1/2" 17 1/2" 18 1/2" Surface - P-047701-0113 (495 mm) (521 mm) (445 mm) (470 mm) 14-13

Bedside Stations 7302 Series > 3 maintained contacts > Stainless steel face plate > "Emergency" engraved units available > 3 amps at 125V AC; 0.5 amps at 125V DC The Edwards Bedside Station provides emergency call activation. Calls are placed by pulling one of the attached 6 foot (1.83m) cords. Cords are replaceable with a standard nylon cord. Designed for either flush or surface mounting. Unit fits in a standard single-gang electrical box and plaster cover. For surface mounting, use a Wiremold surface box. All boxes must have a minimum depth of 1 3/4" (44mm). Boxes and covers not supplied. Use in private and semi-private hospital rooms. Use in emergency stations and patient bath and toilet areas, hospitals, public restrooms, and handicapped areas. 2 3/4" (70mm) 7/8" (22mm) 1 3/8" (35mm) Cat. No. 7302A 7302AE Description Double cord Double cord, face plate engraved "Emergency" 14-14

Wall Stations 7603 & 7613 Series 7613 shown The Edwards 7603 & 7613 Wall Station provides convenient call activation. Calls are placed by simply pushing the locking-type pushbutton on the front of the station. The 7603 has one button. The 7613 has one button and one white "call placed" lamp. When a call is made, the lamp on the front of the unit illuminates, thereby assuring the patient that the call has been properly placed. Models available with face plate engraved "Emergency." Designed for either flush or surface mounting. Unit fits in a standard single-gang electrical box and plaster cover. For surface mounting, use a Wiremold surface box. All boxes must have a minimum depth of 2 1/4" (57mm). Boxes and covers not supplied. Use for patient service and staff convenience in all ambulatory patient areas. Often used in medical facilities, lavatories, and other areas where pull cords are not required or desired. > 7603 has three maintained contacts, one momentary contact > 7613 has two maintained contacts, one momentary contact > Stainless steel faceplate > Heavy duty pushbutton > "Emergency" engraved units available > Depth in wall box: 1 7/8" (48mm) > 24V AC/DC 1 7/8" (48mm) Call Button Reset Cat. No. Description 7603B Locking type 7603E Locking type, face plate engraved "Emergency" 7613 Locking type 7613E Locking type, face plate engraved "Emergency" 14-15

PUSH BUTTONS & CONTACT DEVICES Pendant Push Button 7620 The Edwards 7620 Push Button is a low voltage pendant type button. Its shell is constructed out of shock resistant polypropylene. The pendant has a locking push feature combined with a momentary contact. The button has no exposed screws or parts and the shell revolves 360 without damage to the wiring. The button is easily reset by pressing the collar at any point. For use as a patient's call button in hospitals and institutions. > Locking push mechanism > Momentary contact > Tamper proof > Wire entrance diameter: 11/32" (9mm) > See Table OPEN LOCKED MOMENTARY LOW VOLTAGE FEED Cat. AC DC Finish Dimensions No. Type Volts Amps Amps Rim Center Length Width 7620 Locking 12 4.0 2.0 Gray Gray 3 3/8" 1 9/16" momentary 24 2.0 1.0 (86mm) (40mm) pendant 48 1.0 0.5 10-19

Corridor Dome Stations Audible and visual signals, internal buzzer 7633 Series > Available with 2 or 4 lamps > Internal buzzer > Stainless steel faceplate > White dome The Edwards 7633 Series Corridor Dome Stations are for use with nurse call systems to visually and audibly indicate the placement of room calls. Stations are available with 2 or 4 lamps; the domes are designed with barriers between the lamps to prevent visual interference of signals. The 7633 mounts in a standard double gang box with a plaster cover and a minimum depth of 1 3/4" (44mm). Boxes and plaster covers not supplied. For use above entrances to rooms equipped with a bedside call station. See 7302 Series on page 14-14. 4 9/16" (116mm) 3 5/16" (84mm) 1 1/2" (38mm) 14-16 Volts Dome Clear Lamp VA Cat. No. Description Lamps AC Color* Repl** Per Lamp 7633-2 Duty/Utility Station 1 clear, 24 White A 4.3 with buzzer and 1 red*** 7633-4 buzzer cut-off 2 clear, 24 White B 4.75 switch 2 red*** *Dome replacement - P-047047-0006 **A - 509K, G6, 24V AC Candelabra Screw; B - 313, T 3 3/4" 28V Min. Bayonet ***Red lamp replacement - 24V: P-036350-0001; 120V: P-008636-0001

Corridor Dome Stations ADA/HOSPITAL SIGNALING DEVICES 7641 & 7641R Series The Edwards 7641 & 7641R Series Corridor Dome Stations are for use with nurse call systems to visually indicate the placement of room calls. Stations are available with 1, 2 or 4 lamps; the domes, available in white or red, are designed with barriers between the lamps to prevent visual interference of signals. The 7641 & 7641R mount in a standard single or double gang box with a plaster cover and a minimum depth of 1 1/2" (38mm). Boxes and plaster covers not supplied. For use above entrances to rooms equipped with a bedside call station. See 7302 Series on page 14-14. > Available with 1, 2 or 4 lamps > Stainless steel faceplate > White or red dome OPTIONS > "X-Ray In Use" replacement lenses. Order 7641-A1 for wall mount orientation. Order 7641-A2 for ceiling mount orientation. 4 9/16" (102mm) 3 5/16" (109mm) 1" (25mm) 4 9/16" (102mm) Volts Dome Clear Lamp VA Cat. No. Description AC Color* Repl** Per Lamp 7641-1G5 Corridor dome station 24 White B 4.75 7641-1N5 with 1 white lamp 120 White A 6.0 7641-2G5 Corridor dome station with 24 White B 4.75 7641-2N5 2 lamps (1 white, 1 red***) 120 White A 6.0 7641-4G5 Corridor dome station with 24 White B 4.75 4 lamps (2 white, 2 red***) 7641R-1G5 Corridor dome stations with 24 Red B 4.75 7641R-1N5 1 white lamp 120 Red A 6.0 *Dome replacement - White: P-047047-0006 Red: P-047047-0008 **A - 6S6 120V AC Candelabra Screw; B - 313, T3 3/4" 28V Min. Bayonet ***Red lamp replacement - 24V: P-036350-0001; 120V: P-008636-0001 14-17

Calling Cord Sets 7675, 7676, 7685 & 7686 The Edwards Calling Cord Sets are for use with Edwards Cat No. 7930 and 7930L bedside stations. The cord sets have either one (7675 and 7685) or two (7676 and 7686) dependable positive action buttons to insure easy placement of calls. The vinyl outer covering provides a durable insulation that will withstand frequent cleaning and hard usage without cracking or fraying. The security clamp firmly attaches to the bed sheets or pillows in a manner that will not tear or damage them. For use with nurse call bedside stations. > Pendant locking button(s) > Single cord sets (7675, 7685) > Double cord sets (7676, 7686) > 6 ft. (1.83m) cord(s) (7675, 7676) > 15 ft. (4.58m) cords (7685, 7686) > Security clamp and plug > Momentary contact Calling Cord Security Clamp 7615 This security clamp attaches firmly to the bed sheets or pillows in a manner that will not tear or damage them. This security clamp is for use with Edwards Cat. No. 7675, 7676, 7685 and 7686 calling cord sets. 14-19

Wall Stations Cat. No. 7930 Cat. No. 7930L 7930 & 7930L > Stainless steel face plate > May use either single or dual button calling cords > 24V AC (Use Cat. No. 88-50 or 88-100 transformer. See pg 11-5) > Contact rating: 2 amps The Edwards 7930 & 7930L Wall Stations provide convenient call activation. Calls are placed by activating a locking button calling cord. The 7930L has a lamp on the front of the unit which illuminates when a call is made, thereby assuring the patient that the call has been properly placed. Calls are automatically placed if the calling cord is accidentally pulled from the receptacle. Calling cord must be ordered separately. Use in medical buildings, assisted living facilities, and in private and semi-private hospital rooms. 14-18