VicFlex TM Stainless Steel Sprinkler Fittings

Similar documents
FIRELOCK NXT AUTOMATIC VALVE SYSTEMS NOT JUST VALVES SIMPLICITY.

40.65 V36, K8.0. Dry Type Standard Spray. Horizontal Sidewall. Recessed Horizontal Sidewall

FLUSH HORIZONTAL SIDEWALL

40.60 V36, K5.6. Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent

40.60 V36, K5.6 SLEEVE AND SKIRT PLAIN BARREL

40.61 V36, K8.0 SLEEVE AND SKIRT PLAIN BARREL

FireLock NXT TM Automatic Valve Systems

FIRE-PAC SERIES 745 FIRELOCK SYSTEMS

10.85 VicFlex Sprinkler Fittings

Series 759 FireLock Alarm Check Valve

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION

Victaulic Vic-Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 10.85

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

DISCONTINUED PRODUCT

40.11 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

DISCONTINUED PRODUCT. reference publication

40.19 V34, K115 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

AESTHETIC SPRINKLERS.

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

Victaulic VicFlex Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

Specialties Quality, Durability, Reliability. FIrE ProTECTIon

STORAGE FIRE PROTECTION SPRINKLERS

Model F1FR Series Quick Response Standard Spray

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Sprinkler Guards Model C Model D

Model F3 Dry Sprinklers

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler. Product Features. Product Description

Victaulic Europe Phone: Fax:

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Model APD. Remote alarm panel for diesel motor driven fire pump. Drawing Submittal Package

Rapidrop Global Ltd. Product Range. British Manufacturer and Supplier of Fire Sprinkler and Fire Suppression Equipment.

COMMERCIAL CONSTRUCTION ENGINEERED ELECTRICAL & FASTENING SOLUTIONS COMMERCIAL APPLICATIONS

Net Safety ST3 XChem Toxic Gas Sensor

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Accuracy counts! Sensors with analog output

Microfast quick response Fusible element hsw sprinkler

microfast sr/qr extended coverage pendent sprinkler

SI 3C LP. 4" Low Profile Back Can. Speakers. n 3" (7.6 cm) full-range driver with a tuned port

quick response Sprinkler 105a October 25, 2010

Finishes Plain Brass Chrome Plated and other Finishes Available Upon Request. For cabinets and other accessories refer to separate sheet.

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

Dräger PointGard 2100 Detection of toxic gases and vapours

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

Dräger Bump Test Station Calibration and Bump Testing

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

Kitemark Certificate No. KM

TECHNICAL DATA OBSOLETE

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

Non-Storage / Special Protection / Storage Sprinklers

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

standard response dry horizontal sidewall sprinklers

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

microfast quick response Pendent sprinkler VK302 (K5.6)

Gas Station & C Store SECTION CWM Job No

standard response fusible link sidewall sprinkler VK112 (K5.6)

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

TECHNICAL DATA. Page 1 of 6

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

2. Welding Materials and Procedures shall conform to the ASME Code.

quick response horizontal sidewall sprinkler vk360 (K8.0)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

mirage standard response concealed pendent sprinkler vk492 (K5.6)

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

FF 120T FF 220T EXTRON EXCLUSIVE PATENT PENDING FLAT FIELD SPEAKER WITH TRANSFORMER SPEAKERS. See How it Works WHITE PAPER

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

Dräger Configuration and Evaluation Software

NETWORKING AND INTEGRATION

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Transcription:

V i c t a u l i c f i r e p r o t e c t i o n s y s t e m s Fast, dependable installation up to 10x faster than rigid pipe Durable performance Cost-effective maintenance and retrofit VicFlex TM Stainless Steel Sprinkler Fittings l Commercial Suspended Ceilings l Hard Ceilings l Institutional Applications l Clean Rooms l Industrial Duct Systems l Optional Factory Pre-Assembly with Sprinklers l Accessories

Commercial Drop Ceilings Institutional Applications Series AQB Braided Systems Series AQU Unbraided Systems l For suspended or hard-lid ceilings l 31 72" system lengths available l Series AQB braided system is FM Approved l Series AQU unbraided system is culus 2443 Listed l See System Accessories for 90 Elbows l One bracket design for pendent, semi-recessed and concealed sprinkler installation l See Submittal Publication 10.85 for more information Series AQI Braided Systems for Institutional Applications l For pendent or sidewall installation in block walls ranging from 3 12" in thickness l 31 72" system lengths available l Series AQI braided system is FM Approved l One-piece, patent-pending, open gate installation-ready bracket l Reducer nipples available in 5.5, 9.0 and 13.0" lengths l See Submittal Publication 10.88 for more information

Clean Rooms Duct Systems Series AQC Braided Systems for Clean Room Applications l For installations requiring the elimination of potential leaks and the preservation of room integrity l 24 72" system lengths available l Series AQC braided system is FM Approved l FM Approved with twelve of the leading industry clean room ceiling manufacturers see Submittal Publication 10.86 for full list l Each system is made to order use Victaulic Order Form SF-34 to specify unique dimensional requirements for each ceiling application l Contact Victaulic Customer Care for lead times and delivery information Series AQD Braided Systems for Industrial Duct Systems l For installations within round or square duct work to provide fire protection where combustible gasses may be present l 24 72" system lengths available l Series AQD braided system is FM Approved l FM Approved for ducts made of fiberglass-reinforced plastic (FRP) contact Victaulic for other applications l See Submittal Publication 10.87 for more information

Pre-Assembled Systems System Accessories Order Systems with Factory-Installed Sprinkler Heads Save Up To 60% Installation Time l Series AQB braided and Series AQU unbraided systems may be ordered with the sprinkler already installed and factory leak-tested l 24 72" system lengths available l Ships with 1-BEE 2 24" bracket l Includes escutcheon and protective plastic cap for sprinkler l Available with the following Victaulic FireLock Pendent Sprinklers: V2707 K5.6 Standard Response in Chrome or White V2708 K5.6 Quick Response in Chrome or White V3802 K5.6 Quick Response Concealed with Cover Plate in range of colors and finishes Optional Accessories to Speed Installation l Victaulic FireLock Style 922 Outlet T Fast, mechanical hole-cut branch-line installation See Submittal Publication 10.52 for more information l VicFlex Reducer Nipples for Series AQI institutional applications Available in 5.5, 9.0 and 13.0" lengths See Submittal Publication 10.88 for more information l VicFlex 90 Elbows for Series AQU and Series AQB installations in tight spaces Available in 4.0 and 6.0" lengths See Submittal Publication 10.85 for more information

Installation Without Hassle The patent-pending 1-BEE 2 installation-ready bracket installs up to 5x faster than any competitive bracket technology while providing easy vertical and horizontal positioning of the sprinkler and secure mounting to the ceiling grid. No tools are required to install the 1-BEE 2 bracket and it ships to the jobsite in one piece, ready to install right out of the box. The 1-BEE 2 bracket is designed to firmly grip the ceiling grid, locking the sprinkler into proper operational position. Tamper-resistant screws are available as required. The unique, adjustable open-gate center bracket saves time and money during installation by allowing for final placement of the sprinkler head and escutcheon without tools, even after the system has been pressure-tested. In some regions, the 1-BEE 2 bracket is available with an adjustable end bracket. This adjustment allows the VicFlex system to be installed on ceiling grids outside of typical 24 or 48" ceiling tile dimensions. Contact Victaulic for details and availability.

VICTAULIC GLOBAL CONTACT INFORMATION US & WORLD HEADQUARTERS P.O. Box 31 Easton, PA 18044-0031 USA 4901 Kesslersville Road Easton, PA 18040 USA 1-800-PICK-VIC (+1-800-742-5842) (within North America) +1-610-559-3300 +1-610-250-8817 (fax) pickvic@victaulic.com CANADA 123 Newkirk Road Richmond Hill, ON L4C 3G5 +1-905-884-7444 +1-905-884-9774 (fax) viccanada@victaulic.com CENTRAL AND SOUTH AMERICA P.O. Box 31 Easton, PA 18044-0031 USA 4901 Kesslersville Road Easton, PA 18040 USA +1-610-559-3300 +1-610-559-3608 (fax) vical@victaulic.com UNITED KINGDOM Units B1 & B2, SG1 Industrial Park Cockerell Close Gunnels Wood Road Stevenage Hertfordshire, SG1 2NB (UK) +44-(0)-1438-310-690 +44-(0)-1438-310-699 (fax) viceuro@victaulic.be EUROPE Prijkelstraat 36 9810 Nazareth, Belgium +32-9-381-15-00 +32-9-380-44-38 (fax) viceuro@victaulic.be MIDDLE EAST P.O. Box 17683 Unit XB 8 Jebel Ali Free Zone Dubai United Arab Emirates +971-4-883-88-70 +971-4-883-88-60 (fax) INDIA Victaulic Piping Products India Priv. Ltd. Indialand Global Industrial Park Plot 4, Hinjewadi, Phase I, Mulshi Pune 411057 (India) +91-20-67-919-300 +91-20-67-919-361 (fax) ASIA Unit 06-10, Floor 3A A Mansion 291 Fumin Road Shanghai, China 200031 +86-21-6170-1222 +86-21-6170-1221 (fax) vicap@victaulic.com Australia and New Zealand 7 Chambers Road Unit 1 Altona North, Victoria Australia 3025 1-300-PIC-VIC (+1-300-742-842) (within Australia) +61-3-9392-4000 +61-3-9392-4096 (fax) vicaust@victaulic.com www.victaulic.com www.victaulic.com/vicflex PB-407 6101 Rev. B Victaulic is a registered trademark of Victaulic Company. 2012 Victaulic Company. All rights reserved.