Main switch current K: with main switch (optional)

Similar documents
Integrated Solutions Low Voltage Systems

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Specialty Products SPECIALTY PRODUCTS. Description. Camera Housing. VCB series Video Camera Housings 548. Specialty Products

ATEX certificate. Item Model Product Ex-mark/ Date of issue Remark LCIE certificate. Ⅱ2 G Ex dⅡc T6 Gb Ⅱ2 G Ex eqⅡc Gb

OPTA-PERIPH 8 Av. de Bretteville Neuilly - France 33(0) Fax : 33(0) Document: IM By PB Date: 18/11/2005

Manual for QX0201 Push Button

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Fan Heaters Type VLEx

Manual Power relay SR853

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

IECEx Certificate of Conformity

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Operating Manual Distribution box

new new Industrial plugs and sockets

Annubar Flowmeter Series

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Explosion-proof Immersion Heater Type D-8660

Exp, pressurized systems

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Dual certification! Air handling units for potentially explosive atmospheres

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

IECEx Certificate of Conformity

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

IECEx Certificate of Conformity

Survey of electrical equipment installed in hazardous areas on tankers

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Explosion Protected Panelboards D2Z Series

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Cable Glands DB Series: Drain, Breather Valves and Unions

Dust Explosion Protection Consistent with North American Practice

Rosemount 752 Fieldbus Remote Indicator

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

CF1 ProVector Explosion-Proof Heaters

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

Easy installation Certified for zones 1 and 21 High IP degree of protection

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Description. Applications

VSD AND SS DRIVING ATEX MOTORS February 2014

Certificate of Compliance

Certification Supplement Manual

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

Comfort. Description. Applications

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Explosion Proof Combination Signal db (A) / 5 Joule

Hazardous Area Portable Fan Heater The Bulldog

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

PANELBOARD PROTECTION ON A GLOBAL SCALE

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

INSTRUCTION MANUAL (ATEX / IECEx)

Snifter ATEX22 VERSION. User Manual. Distributor

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

INSTRUCTION MANUAL (ATEX / IECEx)

IECEx Certificate of Conformity

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

Technical Data. Dimensions

High bay LED lighting fixture

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Hazardous Area Portable Fan Heater The Bulldog

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

Electrical Installations Design, Selection, Erection and Inspection

Hazardous Area Zirconia Oxygen Systems

Vortex Enclosure Coolers A/C ATEX

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Flameproof Manual Call Points Series MCP

CR 027 PTC Fan Heater W

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Installation Guide SmartRadar FlexLine

Guide for hazardous areas

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

Multipoint temperature sensor

Stego accessories for cabinets

Electrostatic Hazard Control in Process Industry using Multi Channel Earth Monitor

OPTIBAR DP 7060 Supplementary Instructions

Technical Data. Dimensions

GENERAL SPECIFICATION ELECTRICAL

Transcription:

Control Boxes, Boxes and Other Components BXM(D)81 Series Explosion-proof Illumination (Power) Boxes (Ex d IIB) Explosion protection to -CENELEC -IEC Can be used in Zone 1 and Zone 2 in Zone 21 and Zone 22 Flameproof enclosure (Ex d IIB) Main switch and distribution switch are operated with external handle. Internal termination is finished. Weidumuller SAK EN series terminals are supplied. Entries plugged. Cable glands on request (see P7/17~25). Special requirements on request. Catalogue number logic BX M(D) 81- / / / Main switch current K: with main switch (optional) current number Design No. M: illumination D: power Explosion-proof distribution boxes Zones 1&2; 21&22 /10

Explosion-proof Boxes BXM81 Series Explosion-proof Illumination Boxes (Ex d IIB) Technical data Explosion-proof illumination distribution boxes Explosion protection Gas explosion protection Dust explosion protection Certificates For gas explosion protection For dust explosion protection Conformity to standards General power supply circuit current Exposed fastener Enclosure material Enclosure color Built-in components Main switch switch Terminal Indicator Degree of protection Ambient temperature Cable entries Cable gland(optional) Entry direction Mounting II 2G Ex d IIB T Ex td A21 IP5 T85 BXM81- / / LCIE 10 ATEX PCEC (China) PCEC (China) EN 0079-0:200; EN 0079-1:2004 IEC 0079-0:2004; IEC 0079-1:200; IEC 1241-0:2004; IEC 1241-1:2004 Rated voltage: max. 415V AC 50/0Hz; Rated current: max. 100A 1A, 2A, 4A, A, 10A, 1A,20A, 25A, 2A Stainless steel Copper-free aluminium; powder coated external surface Grey Mini circuit breaker (MCB) or moulded case circuit breaker (MCCB) Note: electrical leakage protection on request Mini circuit breaker (MCB) Note: electrical leakage protection on request Weidmuller SAK EN series Red, green, yellow IP5-20 55 Standard M x 1.5 plug (see the selection table on P/10) DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25. Bottom Surface type (standard) Pedestal type (optional) Electric schematic diagram Circuit 1 Circuit 2 Circuit Circuit N BXM81 Series explosion-proof illumination distribution boxes /11

Explosion-proof Boxes BXM81 Series Explosion-proof Illumination Boxes (Ex d IIB) Selection table of BXM81- / series explosion-proof illumination distribution boxes Description Type Main Indicator Terminal Cable entries switch number switch current number BXM81-4/ /k/ BXM81-/ /k/ BXM81-8/ /k/ BXM81-10/ /k/ BXM81-12/ /k/ BXM81-4/ BXM81-/ BXM81-8/ BXM81-10/ BXM81-12/ MCB or MCCB Current: max. 100A 4 8 10 12 4 8 10 12 MCB 1 P/2 P MCB 1 P/2 P 1A 2A 4A A 10A 1A 20A 25A 2A On request 1A 2A 4A A 10A 1A 20A 25A 2A On request x SAK5EN1N1PE 4 x SAK4EN4N4PE x SAK5EN1N1PE x SAK4ENNPE x SAK5EN1N1PE 8 x SAK4EN8N8PE x SAK5EN1N1PE 10 x SAK4EN10N10PE x SAK5EN1N1PE 12 x SAK4EN12N12PE x SAK5EN1N1PE 4 x SAK4EN4N4PE x SAK5EN1N1PE x SAK4ENNPE x SAK5EN1N1PE 8 x SAK4EN8N8PE x SAK5EN1N1PE 10 x SAK4EN10N10PE x SAK5EN1N1PE 12 x SAK4EN12N12PE 4 x M25 x 1.5 x M25 x 1.5 8 x M25 x 1.5 10 x M25 x 1.5 12 x M25 x 1.5 4 x M25 x 1.5 x M25 x 1.5 8 x M25 x 1.5 10 x M25 x 1.5 12 x M25 x 1.5 Note 1. Please specify the number and size of cable entries and sides of the enclosure to be fitted. 2. Single line drawing (SLD) shall be provided by user. Photocell, timer, AC contactor, thermal relay or others on request.. Please specify mounting type when ordering. 4. Rainproof canopy on request. /12

Explosion-proof Boxes BXD81 Series Explosion-proof Power Boxes (Ex d IIB) Technical data Explosion-proof power distribution boxes BXD81- / Explosion protection Gas explosion protection Dust explosion protection Certificates For gas explosion protection For dust explosion protection Conformity to standards General power supply circuit current Exposed fastener Enclosure material Enclosure color Built-in components Main switch switch Terminal Indicator Degree of protection Ambient temperature Cable entries Cable gland(optional) Entry direction Mounting II 2G Ex d IIB T Ex td A21 IP5 T85 LCIE 10 ATEX PCEC (China) PCEC (China) EN 0079-0:200; EN 0079-1:2004 IEC 0079-0:2004; IEC 0079-1:200; IEC 1241-0:2004; IEC 1241-1:2004 Rated voltage: max. 415V AC 50/0Hz; Rated current: max. 250A 1A, 2A, 4A, A, 10A, 1A, 20A, 25A, 2A, 40A, 50A, A Stainless steel Copper-free aluminium; powder coated external surface Grey Mini circuit breaker (MCB) or moulded case circuit breaker (MCCB) Note: electrical leakage protection on request Mini circuit breaker (MCB) Note: electrical leakage protection on request Weidmuller SAK EN series Red, green, yellow IP5-20 55 Standard M x 1.5 plug (see the selection table on P/12) DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25. Bottom Surface type (standard) Pedestal type (optional) Electric schematic diagram Circuit 1 Circuit 2 Circuit Circuit N BXD81 Series explosion-proof power distribution boxes /1

Explosion-proof Boxes BXD81 Series Explosion-proof Power Boxes (Ex d IIB) Selection table of BXD81- / series explosion-proof power distribution boxes Description Type Main Indicator Terminal Cable entries switch number switch current number BXD81-4/ /k/ BXD81-/ /k/ BXD81-8/ /k/ BXD81-10/ /k/ BXD81-12/ /k/ BXD81-4/ BXD81-/ BXD81-8/ BXD81-10/ BXD81-12/ MCB or MCCB Current: max. 250A 4 8 10 12 4 8 10 12 MCB P MCB P 1A 2A 4A A 10A 1A 20A 25A 2A 40A 50A A On request 1A 2A 4A A 10A 1A 20A 25A 2A 40A 50A A On request x SAK70/5EN1N1PE 12 x SAK10EN4N4PE x SAK70/5EN1N1PE 18 x SAK10ENNPE x SAK70/5EN1N1PE 24 x SAK10EN8N8PE x SAK70/5EN1N1PE 0 x SAK10EN10N10PE x SAK70/5EN1N1PE x SAK10EN12N12PE x SAK70/5EN1N1PE 12 x SAK10EN4N4PE x SAK70/5EN1N1PE 18 x SAK10ENNPE x SAK70/5EN1N1PE 24 x SAK10EN8N8PE x SAK70/5EN1N1PE 0 x SAK10EN10N10PE x SAK70/5EN1N1PE x SAK10EN12N12PE 4 x M25 x 1.5 x M25 x 1.5 8 x M25 x 1.5 10 x M25 x 1.5 12 x M25 x 1.5 4 x M25 x 1.5 x M25 x 1.5 8 x M25 x 1.5 10 x M25 x 1.5 12 x M25 x 1.5 Note 1. Please specify the number and size of cable entries and sides of the enclosure to be fitted. 2. Single line drawing (SLD) shall be provided by user. Photocell, timer, AC contactor, thermal relay or others on request.. Please specify mounting type when ordering. 4. Rainproof canopy on request. /14

Explosion-proof Boxes BXM81 Series Explosion-proof Illumination Boxes (Ex d IIB) Dimension drawings (all dimensions in mm) - subject to alteration BXM81-4/ /K BXM81-/ /K BXM81-8/ /K BXM81-10/ /K BXM81-12/ /K /15

Explosion-proof Boxes BXD81 Series Explosion-proof Power Boxes (Ex d IIB) Dimension drawings (all dimensions in mm) - subject to alteration BXD81-4/ /K BXD81-/ /K BXD81-8/ /K BXD81-10/ /K BXD81-12/ /K /1

Explosion-proof Boxes BXM(D)81 Series Explosion-proof Illumination (Power) Boxes (Ex d IIB) Dimension drawings (all dimensions in mm) - subject to alteration Pedestal type Surface type /17