CONDENSATE MANAGEMENT SYSTEMS

Similar documents
CONDENSATE MANAGEMENT SYSTEMS

Safe-T-Switch 13 EZ Trap 17 AquaGuard 20 Condensate Pans & Risers 29. Acid-Detector 40 Acid-Detector for POE 40 Oil-ID 40 Turbo-Kleen 41

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

HVAC-R Product Catalog

Wolff Bros. Supply, Inc. Services

Safety and Installation Instructions Model 1700

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

HIGH-EFFICIENCY FURNACES

Installation, Safety & Maintenance Manual Model 1750A/1770A

Model 1750A/ 1770A Dehumidifier Installation Instructions

R-410A. Installer s Guide WARNING: 18-GE04D2-5

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

EVAPORATIVE COOLER PUMPS

HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

LIFTAIRE II ELEVATOR AIR CONDITIONER

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

MERIT Series R-410A - Upflow / Horizontal

391 WEST WATER STREET TAUNTON, MA P: F:

WE VE MADE OUR 90% FURNACES 100% EASIER. (Our 90% furnaces now make you more efficient, too.)

Installation Instructions

Oil Heating. Low Profile Highboy Furnaces OH6, OD6, OH8 Series. Built Tough for Lifetime Comfort

Consumer Products Catalog

Installation Instructions

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Land Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2007

Rheem Ingenuity. Innovation And Then Some. New Prestige Series High Efficiency Water Heaters

Model 1820 Dehumidifier

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING


Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

Installation Instructions

Installation Instructions

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Installation Instructions

INSTALLATION INSTRUCTIONS

LEAKSTOPPER 1 Single zone water leak detection system

I/O ZONE 560/583 AND OPERATION MANUAL

CHECKFIRE 210 Detection and Actuation System

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

The most advanced Supply Box System from Oatey - the choice of plumbing professionals.

Product Catalog. Condensate Removal Ice Machine Replacement Evaporative Cooler Accessories. Engineered Products HVAC. Industrial

Flexible Heaters. of Silicone Rubber & Kapton

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Installation Instructions Owner s Manual

Gobi II. English. Condensate Pump Instruction manual Gobi II

AND WORRY-FREE PERFORMANCE

"I'm a Daikin Comfort Pro"

HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing

TECHNICAL SPECIFICATIONS

Inspection Checklist Mechanical Rough in

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

MERIT Series R-410A - Upflow / Horizontal

RHEEM 90%+ GAS FURNACES

Smart-Wall TV Kit - Installation & Operation Instructions -

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

LEAKSTOPPER RANGE Multizone water leak detection systems

The most advanced Supply Box System from Oatey - the choice of plumbing professionals.

SpeedClean. Work Smarter NEW! Innovative cleaning products for maximum HVAC system efficiency. Innovative Maintenance Tools.

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

Feel the difference! Uncompromised Comfort Unrivaled Value C US. Mark of Superior Quality SERIES

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR

GEOTHERMAL: THE SMARTER CHOICE

INSTALLATION INSTRUCTIONS

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Vertical Upflow Horizontal Left Air Handlers

Geothermal HIGH EFFICIENCY HEATING & COOLING. the logical choice for energy efficient residential heating and cooling

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

SOLID PLUS HEAT

HVAC Equipment Access Equipment Location

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

introduction Submittal Data Sheet CENTRA-GUARD POINT LEAK DETECTION

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

CONTENTS A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT 2 ELECTRICAL DATA 2 OPERATING INSTRUCTIONS 4

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

MicroRay IR-100 NEW. Inspection MicroRay IR-100

AND WORRY-FREE PERFORMANCE

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

RG7D 1-Stage Heat Series

condensate removal pumps

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Transcription:

CONDENSATE MANAGEMENT SYSTEMS

AG-1100+ Magnetic Float Switch System for Metal Secondary Drain Pans The AG-1100+ is incredibly easy to install. It can be mounted to the drain pan in 10 seconds or less. Installation does not require any pre-drilling for screws. The AG-1100+ incorporates a protective cover to keep out insulation and debris that could prevent the float from rising. Features: High Capacity 5 Amp, 24Volt AC Magnetic Float Switch Easy, Drill-Free Installation Residential and Commercial Applications Pull Up Test Knob Protective Housing Keeps Out Insulation, Pests, and Debris Normally Open 3rd Wire for Optional External Alarm, Digital Controller, or Energy Management System US Patent 7,710,283 UL 508 Approved IND. CONT. EQ. 75MF UL 508 Just pull the knob up to test. Product Code 96100 AG-1200+ Magnetic Float Switch For Metal & Plastic Secondary Drain Pans The AG-1200+ has all of the features of the 1100+ plus an innovative two-piece clamp design which allows it to be mounted to a metal secondary drain pan (without a lip) or a plastic secondary drain pan (with a lip) in 10 seconds or less, without screws or drilling. Product Code 96106 Features: High Capacity 5 Amp, 24Volt AC Magnetic Float Switch Easy, Drill-Free Installation Residential and Commercial Applications Pull Up Test Knob Protective Housing Keeps Out Insulation, Pests, and Debris Normally Open 3rd Wire for Optional External Alarm, Digital Controller, or Energy Management System US Patent 7,710,283 UL 508 Approved IND. CONT. EQ. 75MF UL 508 C-14

NEW and IMPROVED Now with Adjustable Height Mount AG-1250E AG 1250E MULTIPURPOSE WATER SENSOR METAL/PLASTIC SECONDARY DRAIN PANS Product Code 96108 The AG-1250E multipurpose water sensor is mounted directly in a metal or plastic secondary pan, floor or wall. The AG-1250E is a high-amperage, solid state sensor with no moving parts to break down or become clogged. The low profile design makes it easy to install. Key Features PRODUCT SPECS UL 508 Approved Normally Open or Closed Voltage Rating: 24 VAC, 5 Amp Normally Open 4th Wire for Optional External Alarm, Digital Controller or Energy Management Systems Switch can be normally open or normally closed Versatile mounting options allow positioning on the unit, in a secondary pan, floor or wall 5 Amp, 24 Volts AC solid state sensor Clip on mounting base for easy cleaning and drying of sensor NEW adjustable height mount IND. CONT. EQ. 25XE UL 508 Metal Contacts Can be mounted with double sided tape, adjustable height clip or screw. Proprietary design sensors can detect as little as 1/16 of water. C-14 US Patent 8,578,770

AG-2550E INLINE WATER SENSOR FOR PRIMARY DRAIN LINE AND SECONDARY DRAIN PAN The AG 2550E electronic water sensor is designed for use on the primary drain line and is integrated with an access port for clearing and removing clog causing debris. The water sensor has no moving parts and the unique design of the insulated housing allows the application of chemicals to clean the drain without any worry of retrograde backflow into your HVAC unit. Key Features Electronic In-Line Water Sensor and Insulated Access Port for Primary Drain Lines. Unobstructed 3/4 Inch Flow-Switch does not Impede Drainage. Integrated Easy Access Port for Cleaning Out Drain Lines and Adding Chemicals. Bonus Secondary Sensor with Water Detection LED Light for secondary drain pans 2 SENSORS, ONE PRICE. Normally Open 4th Wire for Optional External Alarm, Digital Controller or Energy Management Systems. HORIZONTAL INSTALLATION VERTICAL INSTALLATION US Patent 8,154,313 & 8,578,770 Product Code 96110 E-14

AG-3125E AG 3125E ONE PRIMARY PAN CONDENSATE SENSOR The AG-3125E primary pan sensor is mounted directly in the auxiliary drain port of the primary pan. The AG-3125E is a highamperage(5amp), solid state sensor with no moving parts to break down or become clogged. Key Features Voltage Rating: 24 VAC, 5 Amp UL 508 Approved Time Delay Water Detection LED New uick Pull Adhesive Tape Available in: Single Product Code 96120 3 Pack Product Code 96121 IND. CONT. EQ. 25XE UL 508 6 Pack Product Code 96122 US Patent 8,151,580; 8,154,313; 8,561,417 & 8,578,770 E-14

AG-3150E AG-3175E Plenum Rated AG-3150E & AG-3175E Plenum Rated Primary Pan Sensors with Time Delay The AquaGuard AG-3150E/AG-3175E s primary pan sensor is mounted directly in the auxiliary drain port of the primary drain pan. The bonus secondary sensor can be installed either vertically or horizontally and features a water detection LED. For a vertical application, the bonus secondary sensor can be mounted on the side of the unit. For a horizontal application, the bonus secondary sensor can be installed directly in the metal or plastic secondary drain pan, which allows both sensors to continuously monitor any condensate overflow in both the primary and secondary drain pans two sensors in one. If any condensate overflow is detected in either drain pan, the sensor(s) will automatically shut off the system and activate an optional alarm. Patent Pending Smart Sensor Technology with Time Delay Redesigned Probe Sensor for Increased Reliability Bonus Secondary Sensor Two Sensors for the Price of One 6 Feet of Both Probe & Sensor Wire (A -31 5E Plenum Rated Probe Sensor Wire) 5 Amp, 24 Volts AC Solid State Sensor with Water Detection LED Light Switch Can Be Normally Open or Normally Closed Compact Waterproof Design Normally Open 4th Wire for Optional External Alarm, Digital Controller or Energy Management Systems (Mounted to Side of Unit) (Inside Primary Pan) IND. CONT. EQ. 25XE UL 508 (Inside Secondary Pan) Product Code 96124 (AG3150E) 96126 (AG3175E) US Patents 8,151,580; 8,154,313; 8,561,417; 8,561,417; 8,578,770 E-14

IDEAL FOR COMMERCIAL PACKAGE UNITS, METAL/PLASTIC SECONDARY DRAIN PANS & PRIMARY PAN WITH TIME DELAY The AquaGuard AG-3180E micro-electronic condensate sensor is mounted directly in the primary drain pan. The bonus secondary sensor features water detection LED and easily installs in the metal or plastic secondary drain pan. Both sensors continuously monitor any condensate overflow in the primary and secondary drain pans and automatically shut off the system and activate an alarm if any overflow is detected. Key Features Micro Pan Sensor Plus Bonus Secondary Sensor with Water Detection LED Meets International Building Codes & Primary Pan Code Requirements Now with Time Delay: Up to 60 Seconds On 6 Feet of Both Plenum Rated Probe and Sensor Wire 5 Amp, 24 VAC Solid State Sensor with Patent Pending Smart SensorTechnology Switch Can Be Normally Open or Normally Closed Normally Open 4th Wire for Optional External Alarm, Digital Controller or Energy Management Systems UL 508 Approved IND. CONT. EQ. 25XE UL 508 Product Code 96128 International Mechanical Code 30.2.3.1: On downflow units and all other coils that do not have a secondary drain or provisions to install a secondary or auxiliary drain pan, a water-level monitoring device shall be installed inside the primary drain pan. This device shall shut off the equipment served in the event that the primary drain becomes restricted. Devices installed in the drain line shall not be permitted. E-14 US Patent 7,744,395; 8,151,580; 8,151,621; 8,154,313; 8,169,314; 8,561,417; 8,578,770

AG-3575E AG-3575E COMPLETE ALL-IN-ONE CONDENSATE MANAGEMENT SYSTEM The AquaGuard AG-3575E is the all-in-one solution for a complete and professional HVAC installation. Given the multiple installation options, the AG-3575E is the perfect solution for commercial or self-contained package units, primary pans and metal or plastic secondary drain pans. The AG-3575E includes 3 sensors: Inline electronic water sensor for Primary Drain line Primary pan sensor (Clip-on or Probe) Secondary drain pan sensor Key Features High amperage rating: 5 AMPS, 24VAC 3 Sensors: Primary drain line sensor, Primary pan sensor, Secondary pan sensor Meets both International Building codes and Primary pan code requirements Total of 18 ft of plenum-rated control and sensor wire Bright water detection LED Indicator light for easy diagnostic PVC fittings that allow for vertical/horizontal installation UL 508 Listed AG-2550E IND. CONT. EQ. 25XE UL 508 AG-3176 Mounting Clips Can Be Adjusted for Depth of Pan Water Detection LED Light Proprietary design sensors can detect as little as 1/16 of water. Can be mounted with double sided tape or screw. US Patent 8,154,313 & 8,578,770 Product Code 96130 E-14

AG-4200E AG-4200E PRIMARY PAN SENSOR New Electronic Multipurpose Condensate Overflow Sensor We ve combined the proven water sensing technology of the AG-1250E with our industry leading Goliath and Titan drain pan line to deliver the ultimate condensate management system. The AG-4200E is the complete condensate management system for Goliath, Goliath Furnace, Goliath Value Series nd Titan Drain Pans. Includes Vibration Isolators Product Code 96143 US Patent 8,578,770; 8,317,169 Key Features 3/4 PVC threaded male pipe adapter 24 VAC, 5 Amp 1/4 inch Trigger Depth Smart Sensor Technology Time Delay: Up to 60 Seconds n Controls ormally pen or ormally Closed 6 of Standard Control Wire Compact Waterproof Design Water Detection LED 4th Wire for Alarm UL 508 Approved E-14

AG-4250E AG-4250E PRIMARY and SECONDARY PAN CONDENSATE SENSOR We ve combined the proven water sensing technology of the AG-3150E with our industry leading drain pans to deliver the ultimate condensate management system. Providing the security of TWO sensors and the durability of our drain pans. The AG-4250E is the complete condensate management system for Goliath, Goliath Furnace, Goliath Value, and Titan Flexible Series Secondary Drain Pans. Includes Vibration Isolators Key Features 2 Sensors - Primary and Secondary Pans 24 VAC, 5 Amp 1/4 inch Trigger Depth Smart Sensor Technology (Patent Pending) Time Delay: Up to 60 Seconds n Controls ormally pen or ormally Closed 6 of Probe Wire 6 of Standard Control Wire Compact Waterproof Design Bonus Secondary Sensor Water Detection LED 4th Wire for Alarm UL 508 Approved Product Code 96148 US Patent 8,578,770; 8,317,169 E-14

AG-9100 External Audible and Visual Remote Alarm The ONLY Multipurpose Remote Alarm Approved For Use With AquaGuard Condensate Management Systems The AG-9100 Audible & Visual Remote Alarm is connected directly to AquaGuard Condensate Management Systems. When activated, the AG-9100 produces an audible and visual signal. Key Features Integrated into Most Monitoring Systems (Home Alarm, Water Detection or Condensate Management System, Etc.) 12-24 VAC / 6-32 VDC Circuit, No Battery Required Loud 103db Audible Alert with On/Off Switch Bright White LED Alarm Lights Can be Conveniently Mounted to a Wall, Ceiling, or Directly to a Hot Water Tank or HVAC/R Unit with Two Screws or Included Adhesive Pad Over 250 Feet Away from a Condensate Overflow Switch Included 12 Inches of Lead Wire Product Code 96180 For use with Aquaguard Condensate Management Systems AG-1100+ AG-1200+ AG-1250E AG-2550E AG-3150E AG-3175E AG-3180E AG-3575E AG-4200 Series C-14

AG-9300SERIES AG-9300 SERIES ELECTRONIC CONDENSATE DRAIN SENSOR FOR DUCTLESS MINI-SPLIT SYSTEMS Each system continuously monitors any condensate overflow in the primary drain pan of any ductless mini-split system, and automatically shuts off the system and activates an alarm if any overflow is detected. The AG-9300 Series includes: A - 300-U: (96192) Universal Drain Sensor for Ductless Mini-Split Systems A - 300-MIT: (96194) Drain Sensor for Mitsubishi Ductless Mini-Split Systems A - 300-L : (96196) Drain Sensor for LG Ductless Mini-Split Systems A - 300-CS: (96198) Drain Sensor for Comfort Star Ductless Mini-Split Systems AG-9300 SERIES FEATURES: IND. CONT. EQ. 75MF UL 508 Universal Model is Compatible with All Major Manufacturers Ductless Mini-Split Systems Currently on the Market Additional Models Available with Exclusive Wire Harness Connectors for Mitsubishi, L and CS Meets International Building Codes Long Life Lithium Battery Included (Lasts Up To the Life of the Ductless Mini-Split Unit) Up to 20 Second Make/Break Delay with Automatic Reset uick and Easy Installation Low Battery Audible Alert UL 508 Approved Mounting Clips Adhesive Pad ICC CODE 307.2.3.4 A water-level detection device conforming to UL 508 shall be provided that will shut off the equipment served in the event that the primary drain is blocked. The device shall be installed in the primary drain line, the overflow drain line, or in the equipment- supplied drain pan, located at a point higher than the primary drain line connection and below the overflow rim of such pan. Patent Pending C-14

AG-9150E AG-9150E MULTIPURPOSE WATER SENSOR & ALARM FOR METAL / PLASTIC SECONDARY DRAIN PANS, ON FLOORS, WALLS BASEMENT INSTALLATIONS The AquaGuard AG-9150E is the ultimate condensate management system for any residential or commercial application. The AG-9150E features our awardwinning AG-1250E Multipurpose Water Sensor combined with our AG-9100 External Audible and Visual Remote Alarm. FEATURES External Audible Visual Remote Alarm with Five Bright White LED Lights 103 Decibel Audible Alert that can be mounted over 250 Feet Away Versatile Mounting Options 5 Amp, 24 Volts AC Solid State Sensor with Water Detection LED Light Innovative Mounting Base for Easy Cleaning and Drying of Sensor Switch Can Be Normally Open or Normally Closed with Automatic Reset 6 Feet of Control Wire Included Sensor Features a Compact Waterproof Design UL 508 Approved ALARM Mounts Up To 250 Ft. Away from Condensate Switch E-14 Product Code 96190 US Patent 8,578,770

AG-9150E Smart Sensor Technology with Automatic Reset The sensor features patent pending Smart Sensor Technology and includes an automatic reset. Smart Sensor Technology reduces nuisance tripping caused by moisture inside a drain pan and increases the life span of the HVAC/R compressor. The 24 VAC switch can also be set to either normally open or normally closed. Included Alarm The remote alarm has an audible and visual signal and can be installed over 250 away from the water sensor. The loud 103 decibel audible alert can be heard from over 100 feet away. Five (5) bright white LED lights flash and are visible both day and night when the alarm is activated. The alarm is equipped with an on/off switch to silence the audible alarm while keeping the visual alert active. Easy Overflow or Water Detection Upon overflow or water detection, the multipurpose water sensor s bright red LED Light will trigger and activate the remote alarm. With the alarm located in a convenient or highly visible location, there is no need to go up into an attic, on a roof, or down into a basement to check on the status of the HVAC/R unit or location. The water detection LED light and alarm makes troubleshooting and trip detection easy in both well lit and dark locations for any HVAC contractor, business or homeowner. Innovative Mounting Bracket The multipurpose water sensor features an innovative clip on mounting bracket that allows multiple installation options. The mounting bracket can be mounted directly on HVAC/R units, in a metal or plastic secondary drain pan, on floors or even on a wall and elevates the sensors eliminating false tripping. Dries Easily The innovative mounting bracket also allows water to easily reach the sensors and eliminates the need for a hard-to-dry hydrophilic pad. The sensor can also be quickly and easily removed from the bracket for easy cleaning. Compact Design The AG-9150E sensor measures less than 1.4 inches x 2.0 inches (36mm x 50mm) for complete condensate management in any tight space and includes 6 feet of control wire. Solid State Electronics The multipurpose water sensor is a dependable solid state sensor, which can be completely submerged in water and contains no moving parts that could become clogged like a mechanical float switch. High 5 Amp Capacity With a high 5 amperage capacity, the AG-9150E s multipurpose sensor s state-of-the-art electronics are surge protected from the various electrical currents that occur during compressor turn ons and turn offs. The high load capacity ensures that the switch performs again and again and is more reliable than lower Amp capacity switches, which are not designed to handle excessive loads from today s high efficiency HVAC systems. Metal Contacts Can be mounted with double sided tape, adjustable height clip or screw. Proprietary design sensors can detect as little as 1/16 of water. C-14

Secondary Drain Pans TRUE T THEIR AME: Goliath Series SecondaryDrain Pans are the strongest, most rugged HVAC secondary drain pans on the market today. HANGABLE Made With Pride in the USA from our own patented blend of advanced polymer DexElar material, Goliath Series Secondary Drain Pans are engineered with superior one-piece structural strength to produce a nearly indestructible drain pan with rolled edges and no seams. Goliath Series Secondary Drain Pans provide extreme temperature durability (-40 F to 260 F), high tensile strength, crack/split/leak/rust resistance, and are self extinguishing. DexElar material is UL-94 5VA and ASTM E-84-05 rated. Each pan is strong enough to hang using only one pair of steel support struts, ensuring a quick-and-easy professional installation. They also feature a network of built-in risers, which are compatible with a wide variety of sizes of HVAC units and eliminate the need to shop around for additional risers or mounting blocks. Some Goliath pans have lower risers when space is restricted. Risers run the length of pan for better strength when hanging. Each pan has specially designed indentations for placement of hanging brackets. Goliath Series Secondary Drain Pans are compatible with our AG-4200 Condensate Management System water sensor and drain adapter as well as AG-GFR Vibration Isolators to quiet any noisy HVAC unit. (Sold separately) GOLIATH SERIES PRODUCT PAN SIZE OUTER (MAX) DIMENSION INSIDE (DRIP AREA) DIMENSION CODE # L LENGTH W WIDTH D DEPTH l length w width d depth 96200 26x56 56.625 26.5 2.75 51.0 19.5 2.0 96202 28x57 57.25 28.375 5.25 51.75 21.5 2.0 96204 28x69 69.125 28.25 4.25 66.5 26.0 2.0 96206 30x50 50.5 30.25 4.00 45.0 22.75 2.1 96208 30x62 63.0 30.375 4.25 56.875 22.75 2.1 96210 30x66 66.50 30.25 4.00 64.00 22.75 2.1 All pans meet or exceed all international building codes and come with a 10 Year Limited Warranty. US Patents 7,878,019 7,900,798 & D562,963 E-14

DRAIN PAN SELECTION CHART Secondary Pan Model Pan Size External Pan Size Max Unit Size Recommended Application Goliath Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 28x57 28.38 57.25 5.25 25.38 54.25 28x69 28.25 69.13 4.25 26.00 66.50 30x66 30.25 66.50 4.00 27.25 64.00 Goliath Low Profile Width Length Height Width Length 26x56 26.50 56.63 2.75 23.50 53.63 Goliath Value Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 30x66 30.25 66.50 4.00 27.25 64.00 When additional clearance is needed under air handler for drain. General Purpose for both furnace and air handler installation. When space is at a minimum in a garage or attic. General Purpose for both furnace and air handler installation. Titan Flexible Series Width Length Height Width Length 24x24 24.00 24.00 2.25 20.00 20.50 26x26 26.00 26.00 2.25 22.00 22.50 30x30 30.00 30.00 2.25 26.00 26.50 32x32 32.00 32.00 2.25 28.00 28.50 Titan Flexible Series Width Length Height Width Length 30x50 30.25 50.50 2.50 27.25 47.50 30x62 30.38 63.00 2.50 27.38 60.00 Flexible and durable enough to bend and fit into tight spaces. Flexible and durable enough to bend and fit into tight spaces. Goliath Furnace Series Width Length Height Width Length 30x36 30.50 37.50 3.00 27.50 34.50 For Vertical, upflow installation of furnace or air handler. Goliath Furnace Series Width Length Height Width Length 34x64 34.13 64.13 7.50 31.13 61.13 34x79 33.75 79.00 7.50 30.75 76.00 When greater clearance height is needed to accomodate piping under furnace. 2601 Spenwick Drive Houston, Texas 77055 P: 713/263-8001. 800-231-3345 F: 713/263-7577. 800-441-0051 www.rectorseal.com

SECONDARY DRAIN PANS Goliath Value Series Secondary Drain Pans are the affordable able solution for fixed placement, solid surface applications when hanging a secondary drain pan and HVAC unit is not necessary. essary. They are Made with Pride in the USA from our patented advanced polymer DexElar material and feature a network of built-in risers, which are compatible with a wide variety of sizes of HVAC units. Additional Goliath Value Series Secondary Drain Pans features include: Superior strength, durability and versatility when compared to other HVAC secondary drain pans made of traditional ABS plastics. Will not crack, split, or rust like a metal secondary drain pan. Can support 40% more weight than a traditional ABS plastic pan. Extreme temperature durability -20 F (-28 C) to 260 F (126.7 C) with a higher melting point and self extinguishing characteristics not found in competitors secondary drain pans. DexElar material is UL-94 5VA and ASTM E-84-05 rated - a safer material of choice than ABS plastic. Goliath Value Series Secondary Drain Pans are compatible with our AG-4200 Condensate Management System water sensor and drain adapter as well as AG-GFR Vibration Isolators to quiet any noisy HVAC unit. (Sold separately) Goliath Value Series Secondary Drain Pans are to be used only for fixed placement HVAC installations and must be supported by a solid surface and are not to be hung in any application. Goliath Value Series Secondary Drain Pans meet or exceed all international building codes and come with a 5 Year Limited Warranty. GOLIATH VALUE SERIES PRODUCT PAN SIZE OUTER (MAX) DIMENSION INSIDE (DRIP AREA) DIMENSION CODE # L LENGTH W WIDTH D DEPTH l length w width d depth 96214 30x50 56.625 30.25 4.00 45.25 22.75 2.1 96216 30x62 63.0 30.375 4.25 56.875 22.75 2.1 96218 30x66 66.50 30.25 4.00 64.00 22.75 2.1 All pans meet or exceed all international building codes and come with a 5 Year Limited Warranty. US Patents 7,878,019: 7,900,795 & D562,963 E-14

DRAIN PAN SELECTION CHART Secondary Pan Model Pan Size External Pan Size Max Unit Size Recommended Application Goliath Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 28x57 28.38 57.25 5.25 25.38 54.25 28x69 28.25 69.13 4.25 26.00 66.50 30x66 30.25 66.50 4.00 27.25 64.00 Goliath Low Profile Width Length Height Width Length 26x56 26.50 56.63 2.75 23.50 53.63 Goliath Value Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 30x66 30.25 66.50 4.00 27.25 64.00 When additional clearance is needed under air handler for drain. General Purpose for both furnace and air handler installation. When space is at a minimum in a garage or attic. General Purpose for both furnace and air handler installation. Titan Flexible Series Width Length Height Width Length 24x24 24.00 24.00 2.25 20.00 20.50 26x26 26.00 26.00 2.25 22.00 22.50 30x30 30.00 30.00 2.25 26.00 26.50 32x32 32.00 32.00 2.25 28.00 28.50 Titan Flexible Series Width Length Height Width Length 30x50 30.25 50.50 2.50 27.25 47.50 30x62 30.38 63.00 2.50 27.38 60.00 Flexible and durable enough to bend and fit into tight spaces. Flexible and durable enough to bend and fit into tight spaces. Goliath Furnace Series Width Length Height Width Length 30x36 30.50 37.50 3.00 27.50 34.50 For Vertical, upflow installation of furnace or air handler. Goliath Furnace Series Width Length Height Width Length 34x64 34.13 64.13 7.50 31.13 61.13 34x79 33.75 79.00 7.50 30.75 76.00 When greater clearance height is needed to accomodate piping under furnace. 2601 Spenwick Drive Houston, Texas 77055 P: 713/263-8001. 800-231-3345 F: 713/263-7577. 800-441-0051 www.rectorseal.com

Flexible Series Secondary Drain Pans Used when space requirements are tight, the Titan Flexible Series Secondary Drain Pans are more flexible and durable than fabricated metal or plastic pans. Created from our patented blend of advanced polymer DexElar material will not rust, crack, split or leak like a traditional fabricated metal secondary drain pan. DexElar material is UL-94 5VA and ASTM E-84-05 rated and provides extreme temperature durability (-40 F to 260 F), high tensile strength and is self extinguishing. Titan pans are manufactured with rolled edges and no seams for superior one-piece structural strength and flexibility. They are also specifically designed and engineered to be completely compatible with our Goliath Furnace Series Furnace Risers to create e a complete and professional HVAC installation. Made with Pride in the USA, Titan Flexible Series Secondary Drain Pans are compatible with our AG-4200 Condensate Management System water sensor and drain adapter. (Sold separately) PRODUCT PAN SIZE OUTER (MAX) DIMENSION INSIDE (DRIP AREA) DIMENSION CODE # L LENGTH W WIDTH D DEPTH l length w width d depth 96230 24x24 24.0 24.0 2.25 20.0 20.5 2.25 96232 26x26 26.0 26.0 2.25 22.0 22.5 2.25 96234 30x30 30.0 30.0 2.25 26.0 26.5 2.25 96236 32x32 32.0 32.0 2.25 28.0 28.5 2.25 96238 30x50* 50.5 30.25 2.5 45.0 22.75 2.5 96240 30x62* 63.0 30.375 2.5 56.875 22.75 2.5 * when properly configured with approved steel supports and pressure treated 4 x 4 s. All Titan Flexible Series Secondary Drain Pans meet or exceed all international building codes and come with a 3 Year Limited Warranty. US Patent 7,878,019. E-14

DRAIN PAN SELECTION CHART Secondary Pan Model Pan Size External Pan Size Max Unit Size Recommended Application Goliath Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 28x57 28.38 57.25 5.25 25.38 54.25 28x69 28.25 69.13 4.25 26.00 66.50 30x66 30.25 66.50 4.00 27.25 64.00 Goliath Low Profile Width Length Height Width Length 26x56 26.50 56.63 2.75 23.50 53.63 Goliath Value Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 30x66 30.25 66.50 4.00 27.25 64.00 When additional clearance is needed under air handler for drain. General Purpose for both furnace and air handler installation. When space is at a minimum in a garage or attic. General Purpose for both furnace and air handler installation. Titan Flexible Series Width Length Height Width Length 24x24 24.00 24.00 2.25 20.00 20.50 26x26 26.00 26.00 2.25 22.00 22.50 30x30 30.00 30.00 2.25 26.00 26.50 32x32 32.00 32.00 2.25 28.00 28.50 Titan Flexible Series Width Length Height Width Length 30x50 30.25 50.50 2.50 27.25 47.50 30x62 30.38 63.00 2.50 27.38 60.00 Flexible and durable enough to bend and fit into tight spaces. Flexible and durable enough to bend and fit into tight spaces. Goliath Furnace Series Width Length Height Width Length 30x36 30.50 37.50 3.00 27.50 34.50 For Vertical, upflow installation of furnace or air handler. Goliath Furnace Series Width Length Height Width Length 34x64 34.13 64.13 7.50 31.13 61.13 34x79 33.75 79.00 7.50 30.75 76.00 When greater clearance height is needed to accomodate piping under furnace. 2601 Spenwick Drive Houston, Texas 77055 P: 713/263-8001. 800-231-3345 F: 713/263-7577. 800-441-0051 www.rectorseal.com

Furnace Series Secondary Drain Pans Goliath Furnace Series Secondary Drain Pans offer all the same benefits and features of our Goliath Series Secondary Drain Pans and are specifically designed for the unique clearance ce needs of furnace installations and piping requirements. With 7 of clearance, Goliath Furnace pans offer the necessary clearances for any piping that needs to run below a furnace unit especially with condensing furnace installations. Piping is accessible from either side. Made With Pride in the USA from our own patented blend of advanced polymer DexElar material. They are engineered with superior one-piece structural strength to produce a nearly indestructible furnace pan with rolled edges and no seams. Each pan provides extreme temperature durability (-40 F to 260 F), high tensile strength, crack/split/leak/rust resistance, and are self extinguishing. DexElar material is UL-94 5VA and ASTM E-84-05 rated. Goliath Furnace Series Secondary Drain Pans is compatible with our AG-4200 Condensate Management System water sensor and drain adapter as well as AG-GFR Vibration Isolators to quiet the operation of any noisy furnace unit. (Sold separately) All pans meet or exceed all international building codes and come with a 10 Year Limited Warranty. US Patents 7,637,387; 7,673,646; 7,878,019; & D562,963 GOLIATH FURNACE SERIES PRODUCT PAN SIZE OUTER (MAX) DIMENSION INSIDE (DRIP AREA) DIMENSION CODE # L LENGTH W WIDTH D DEPTH l length w width d depth 96220 30x36* 37.5 30.5 3.00 30.75 23.0 2.375 96222 34x64 64.125 34.125 7.50 59.0 26.75 2.1 96224 34x79 79.0 33.75 7.50 73.5 26.5 2.1 *The Goliath Furnace 30 x 36 x 3.00 pan is designed exclusively for vertical, up flow applications. E-14

DRAIN PAN SELECTION CHART Secondary Pan Model Pan Size External Pan Size Max Unit Size Recommended Application Goliath Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 28x57 28.38 57.25 5.25 25.38 54.25 28x69 28.25 69.13 4.25 26.00 66.50 30x66 30.25 66.50 4.00 27.25 64.00 Goliath Low Profile Width Length Height Width Length 26x56 26.50 56.63 2.75 23.50 53.63 Goliath Value Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 30x66 30.25 66.50 4.00 27.25 64.00 When additional clearance is needed under air handler for drain. General Purpose for both furnace and air handler installation. When space is at a minimum in a garage or attic. General Purpose for both furnace and air handler installation. Titan Flexible Series Width Length Height Width Length 24x24 24.00 24.00 2.25 20.00 20.50 26x26 26.00 26.00 2.25 22.00 22.50 30x30 30.00 30.00 2.25 26.00 26.50 32x32 32.00 32.00 2.25 28.00 28.50 Titan Flexible Series Width Length Height Width Length 30x50 30.25 50.50 2.50 27.25 47.50 30x62 30.38 63.00 2.50 27.38 60.00 Flexible and durable enough to bend and fit into tight spaces. Flexible and durable enough to bend and fit into tight spaces. Goliath Furnace Series Width Length Height Width Length 30x36 30.50 37.50 3.00 27.50 34.50 For Vertical, upflow installation of furnace or air handler. Goliath Furnace Series Width Length Height Width Length 34x64 34.13 64.13 7.50 31.13 61.13 34x79 33.75 79.00 7.50 30.75 76.00 When greater clearance height is needed to accomodate piping under furnace. 2601 Spenwick Drive Houston, Texas 77055 P: 713/263-8001. 800-231-3345 F: 713/263-7577. 800-441-0051 www.rectorseal.com

Goliath Furnace Risers (GFR) are the perfect solution for any furnace installation. GFRs raise furnaces providing the necessary clearance to accommodate piping and p-traps. Available in three sizes, GFR 28x6, GFR 23x4 and GFR 23x7 to accommodate a variety of furnace installation needs. Installation is quick and easy, the GFRs are made to fit either lengthwise or width wise in our Titan pans or fabricated metal pans. DexElar material is UL-94 5VA and ASTM E-84 Class C compliant and 10X stronger than competing metal risers. Goliath Furnace Riser shown with Titan Secondary Drain Pan Key Features Constructed of DexElar, the same durable material as oliath and Titan HVAC secondary drain pans. Will not rust or crack and provide 10x the strength as metal risers. Compatible with our Titan secondary drain pans, metal pans or can be used as a standalone. Available vibration isolators quiet noisy furnace units. GOLIATH FURNACE RISERS PRODUCT MODEL OUTER (MAX) DIMENSION CODE # L LENGTH W WIDTH D DEPTH 96254 GFR 28x6 28.5 7.5 6.0 96250 GFR 23x4 22.5 5.75 3.625 96252 GFR 23x7 22.5 5.75 6.50 All Goliath Furnace Risers meet or exceed all international building codes and come with a 3 Year Limited Warranty. US Patent 8,220,768. E-14

DRAIN PAN SELECTION CHART Secondary Pan Model Pan Size External Pan Size Max Unit Size Recommended Application Goliath Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 28x57 28.38 57.25 5.25 25.38 54.25 28x69 28.25 69.13 4.25 26.00 66.50 30x66 30.25 66.50 4.00 27.25 64.00 Goliath Low Profile Width Length Height Width Length 26x56 26.50 56.63 2.75 23.50 53.63 Goliath Value Series Width Length Height Width Length 30x50 30.25 50.50 4.00 27.25 47.50 30x62 30.38 63.00 4.25 27.38 60.00 30x66 30.25 66.50 4.00 27.25 64.00 When additional clearance is needed under air handler for drain. General Purpose for both furnace and air handler installation. When space is at a minimum in a garage or attic. General Purpose for both furnace and air handler installation. Titan Flexible Series Width Length Height Width Length 24x24 24.00 24.00 2.25 20.00 20.50 26x26 26.00 26.00 2.25 22.00 22.50 30x30 30.00 30.00 2.25 26.00 26.50 32x32 32.00 32.00 2.25 28.00 28.50 Titan Flexible Series Width Length Height Width Length 30x50 30.25 50.50 2.50 27.25 47.50 30x62 30.38 63.00 2.50 27.38 60.00 Flexible and durable enough to bend and fit into tight spaces. Flexible and durable enough to bend and fit into tight spaces. Goliath Furnace Series Width Length Height Width Length 30x36 30.50 37.50 3.00 27.50 34.50 For Vertical, upflow installation of furnace or air handler. Goliath Furnace Series Width Length Height Width Length 34x64 34.13 64.13 7.50 31.13 61.13 34x79 33.75 79.00 7.50 30.75 76.00 When greater clearance height is needed to accomodate piping under furnace. 2601 Spenwick Drive Houston, Texas 77055 P: 713/263-8001. 800-231-3345 F: 713/263-7577. 800-441-0051 www.rectorseal.com