HVS, Hydro Variable System

Similar documents
HVS, Hydro Variable System Air cooled chiller

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

YDCC / YDCH YOCC / YOCH COMPACT ICOM INSTALLATION, COMMISSIONING AND OPERATING MANUAL

YDS Variable Refrigerant Flow System. Digital Scroll Technology 3rd Generation

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

High temperature air-to-water heat pumps

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

YDCC / YDCH YOCC / YOCH condensing units ICOM

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

COLDPACK_. water cooled chillers / heat pumps and condenserless chillers

3 rd Generation of VRV. The professional solution for your professional project

Air-to-water scroll chillers

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

44,9 202,0 kw. technicalcatalogue

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

kw COOLING kw HEATING

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

HT V2 HT Split

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

CRIMSON & CRIMSON MAX

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Process glycol chillers

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SyScroll Air EVO NEW

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

HIWARM COMPACT kw

Integrated VarIable refrigerant flow ahu/pau (r410a)

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

Installation, operating and maintenance ECOLEAN - EAC/EAR

Blue Box Epsilon Echos +

SyScroll 40 to 75 Air NEW

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

kw. technicalcatalogue

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

GHE Dehumidifiers for radiant cooling systems with heat recovery

TCHE-THHE TCEE

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

LZT High efficiency air to water heat pumps with E.V.I. compressors

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Modular Air-cooled Chillers

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Air Cooled Scroll Chiller

pyxis u pyxis ua NEW rcgroupairconditioning

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Modular Air Cooled Scroll Chillers

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Heat pump systems and Chillers

ROOFTOP PACKAGED AIR CONDITIONERS

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Neosys Product catalogue

21,8 222 kw COOLING 25,2 236 kw HEATING

Transcription:

water systems HVS, Hydro Variable System Air cooled chiller / heat YDC_522H (-C) / YDC_972H (-C) / YOC_762H (-C) / YOC_1522H (-C) A complete range from 15 kw up to 72 kw R407C Remote Central Controller Features Variable capacity compressor (10% to 100%) Constant water temperature Energy savings up to 35% BMS communication Easy selection software Low ambient operation standard, no buffer tank needed Flexible in use No glycol required (split version) Integrated hydro kit (compact version) Water filter standard Options / Accessories Condenser protection grilles High static pressure fans Anticorrosion epoxy coils Sound attenuation Softstarter kit DX unit (split version) Antifreeze heater for heat Interface card for LON Bus 3 way for external heating system Anti vibration mounting Outdoor temperature sensor Valve kits Relay box for several FCU applications Fan coil load identification

HVS, Hydro Variable System Split & Compact version Technical features Compact version Models YDCC 522H-C YDCC 972H-C YDCC1732 H-C YDCC 2502 H-C YDCH 522H-C YDCH 972H-C YDCH 1732 H-C YDCH 2502 H-C Cooling capacity c/o units (1) kw 15.0 28.0 50.0 72.0 Heating capacity h/p units (1) kw 16.5 30.5 53.5 76.5 Performance Total Input Power kw 5 9 9.7 + 6.1 9.7 + 12.3 Capacity steps % 10-100 6-100 4-100 3-100 Sound pressure level at 1 m db(a) 58 59 62 63 Compressor Type Digital Scroll Digital Scroll & Scroll Digital Scroll & 2 x Scroll Digital Scroll & 3 x Scroll Quantity 1 2 3 4 Fans quantity 1 2 2 x 2 2 + 3 Air side heat Working Ambient temp. cooling/heating mode (4) -20 C~45 C / -10 C~20 C Type Plate Heat Exchanger Pump type Circulators (3 speeds) Water side Water flow nominal l/h 2 150 4 100 7 200 10 350 heat Available pressure nominal (2) kpa 81 67 67 64 Water connections inch 1 1/2 2 2 + 2 2 1/2 + 2 1/2 Water connections type Threated male Height mm 1 350 1 350 2 x 1 350 1 350 + 1 350 Dimensions Width mm 780 780 2 x 780 2 x 780 & Weight Length mm 1 330 1 500 1 500 + 1 330 1 500 + 1 980 Weight cooling only kg 310 400 435 + 285 400 + 700 Electrical supply Voltage / Phases / Frequency V/ph/hz 400 / 3 / 50+N Combinations YDCC 522H-C YDCC 972H-C YDCC 972H-C + YOCC 762H-C YDCC 972H-C + YOCC 1522H-C YDCH 522H-C YDCH 972H-C YDCH 972H-C + YOCH 762H-C YDCH 972H-C + YOCH 1522H-C Technical features Split version Models YDCC 522H YDCC 972H YDCC1732 H YDCC 2502 H YDCH 522H YDCH 972H YDCH 1732 H YDCH 2502 H Cooling capacity c/o units (1) kw 15.0 28.0 50.0 72.0 Heating capacity h/p units (1) kw 16.5 30.5 53.5 76.5 Performance Total Input Power kw 5 9 9.7 + 6.1 9.7 + 12.3 Capacity steps % 10-100 6-100 4-100 3-100 Sound pressure level at 1 m db(a) 58 59 62 63 Compressor Type Digital Scroll Digital Scroll & Scroll Digital Scroll & 2 x Scroll Digital Scroll & 3 x Scroll Quantity 1 2 3 5 Fans quantity 1 2 2 x 2 2 + 3 Air side heat Working Ambient temp. cool/heat mode (4) -20 C~45 C / -10 C~20 C Refrigerant side Refrigerant connections mm 12 / 22 16 / 28 2 x 16 / 28 16 / 28 + 22 / 42 Max refrigerant piping length m 20 Max height difference m 5 Water side Pump type Circulators (3 speeds) (Transformer Available pressure nominal (2) kpa 81 67 67 64 Box) Water connections (Threated male) inch 1 1/2 2 2 + 2 2 1/2 + 2 x 2 Dimensions H / W / L mm 1350 x 780 x 1330 1350 x 780 x 1500 1350 x 780 x 2850 1350 x 780 x 3500 & Weight Weight cooling only kg 250 325 325 + 280 325 + 550 Electrical supply Voltage / Phases / Frequency V/ph/hz 400 / 3 / 50+N Combinations YDCC 522 H YDCC 972 H YDCC 972 H + YOCC 762 H YDCC 972 H + YOCC 1522 H YDCH 522 H YDCH 972 H YDCH 972 H + YOCH 762 H YDCH 972 H + YOCH 1522 H Nominal cooling capacity based on: leaving water temperature: +7 C - Ambient air temperature: 35 C DB Nominal heating capacity based on: leaving water temperature: +40 C - Ambient air temperature: 7 C DB / 6 C WB Technical features Transformer boxes Models Cooling capacities Heating capacities (YTBH only) (1) Only for heat units (2) At nominal water flow YTBC / YTBH 522 972 1732 2502 Total capacity kw 15.0 28.0 50.0 72.0 Water flow l/h 2150 4100 7200 10350 Capacity kw 16.5 30.5 53.5 76.5 Water flow l/h 2150 4100 7200 10350 Sound pressure level at 3 m free field db(a) 35 35 40 40 Power supply V/Ph/Hz 220-240 / 1 / 50 400 / 3 / 50 Electrical characteristics Power input -nominal W 270 350 1100 1100 Running current - nominal A 1.8 2.0 3.1 3.1 Heigth mm 1000 1000 1200 1200 Dimensions Width mm 800 800 1000 1000 Depth mm 300 300 300 300 Net weight kg 80 95 150 170 Refrigerant piping connections Diameter (nominal) mm 12 / 22 16 / 28 2 x 16 / 28 3 x 16 / 28 Nominal cooling capacity based on: Leaving water temperature: +6 C Nominal heating capacity based on: Leaving water temperature: +40 C Horizontal Transformer Boxes available upon request, for more information contact to Johnson Controls. *) at nominal water flow E-COM-C0904 Manufacturer reserves the rights to change specifications out prior notice.

HVS, Hydro Variable System Split & Compact version Compatibility table / Codes System 15 kw 28 kw 50 kw 72 kw Cooling only models YDCC 522 H (-C) YDCC 972 H (-C) YDCC 1732 H (-C) YDCC 2502 H (-C) Heat models YDCH 522 H (-C) YDCH 972 H (-C) YDCH 1732 H (-C) YDCH 2502 H (-C) Transformer boxes (only for split version) Cooling only models YTBC 522 H-V YTBC 97 2H-V YTBC 1732 H-V YTBC 2502 H-V Heat models YTBH 522 H-V YTBH 972 H-V YTBH 1732 H-V YTBH 2502 H-V Options (factory fitted) Quantity depends on combination selected. See above table in Combinations. Models YDCC 522 H (-C) YDCC 972 H (-C) YOCC 762 H (-C) YOCC 1522 H (-C) YDCH 522 H (-C) YDCH 972 H (-C) YOCH 762 H (-C) YOCH 1522 H (-C) DX Cooling only units (only split model) DX-KIT-CO DX-KIT-CO-S DX-KIT-CO-L DX Heat units (only split model) DX-KIT-HP DX-KIT-HP-S DX-KIT-HP-L Condenser grid CG CGS-1 CGL-1 CGS-1 Contact YORK High static pressure fans HPF HPF-522 HPF-972 HPF-762 HPF-1522 Anticorrosion Epoxy coils ACF-1 l l l l Sound attenuation CSI CSI-522 CSI-972 CSI-762 CSI-1522 Softstarter kit SSK SSK-522 SSK-972 SSK-762 SSK-1522 Water filter WF-1 Standard (in the transformer box for split model, in the unit for compact model) Antifreeze heater for heat and internal piping AFH-1 l l l l Fan coil load identification * LI-1 l l With YDC_ unit With YDC_ unit * The compressor is inactive when all fan coils are switched off. Operation starts again when at least one fan coil is switched on. ATTENTION! Not applicable for fan coil units a coil sensor! Accessories (supplied loose) Remote central controller (mandatory) * l With YDC_ unit With YDC_ unit Interface card for LON Bus LP-NET-102-000 l With YDC_ unit With YDC_ unit 3 way for external heating system EH 32 15-28 kw EH 40 50-72 kw Anti vibration mounting AVM-1 l l l l Outdoor temperature sensor OTS-1 l l With YDC_ unit With YDC_ unit * It is mandatory to have one central controller for HVS unit ** For automatic mode change heat only Accessories for Fan coil units (supplied loose) compatible HVS only - Valve kits not available any more (havent been ordered frequently!) Valve kit diameter 3/8 VK10-1 l Valve kit diameter 1/2 VK15-1 l Valve kit diameter 3/4 VK20-1 l Valve kit diameter 1 VK25-1 l Valve kit diameter 1 1/2 VK40-1 l * Valve kit is assembled and composed of an on/off thermal actuator, 3-way, shut off and balancing Relay box for up to 4 FCU RB4-1 l Relay box for up to 8 FCU RB8-1 l Recommended combinations Cooling capacity YDC_522 YDC_972 YOC_762 YOC_1522 Transformer Box 15 1 1 x YTB 522 28 1 1 x YTB 972 50 1 1 1 x YTB 1732 72 1 2 1 x YTB 2502 72 1 1 1 x YTB 2502 87 1 1 2 1 x YTB 522 + 1 x YTB 2502 87 1 1 1 1 x YTB 522 + 1 x YTB 2502 100 2 2 2 x YTB 1732 122 2 3 1 x YTB 1732 + 1 x YTB 2502 122 2 1 1 1 x YTB 1732 + 1 x YTB 2502 144 2 4 2 x YTB 2502 144 2 2 2 x YTB 2502 159 1 2 4 1 x YTB 522 + 2 x YTB 2502 159 1 2 2 1 x YTB 522 + 2 x YTB 2502 172 3 4 1 x YTB 972 + 2 x YTB 2502 172 3 2 1 x YTB 972 + 2 x YTB 2502 194 3 5 1 x YTB 1732 + 2 x YTB 2502 194 3 1 2 1 x YTB 1732 + 2 x YTB 2502 216 3 6 3 x YTB 2502 216 3 3 3 x YTB 2502

Digital Scroll Compressor Modulation chamber Bleed hole Lift piston assembly Solenoid Spring The Digital Scroll Compressor uses a simple and effective method to modulate the capacity of an AC, giving unparalleled performance in the modulation field. To modulate the capacity the Digital Scroll operates in two stages, the loaded state in which the compressor works as a normal Scroll compressor at full capacity and mass flow, and the unloaded state, where there is not capacity and mass flow. During the unloaded state there is a separation between the scrolls. Once the scrolls separate, any gas passing through is no longer compressed. Changing the cycle time ( Loaded state time and Unloaded state time) determines the capacity modulation of the compressor. System Diagram Compact version The HVS-system is available as a COMPACT version. This version is particularly designed for process cooling applications for very low brine-temperatures (down to -5 C) but is also applicable for standard AC applications. The HVS-COMPACT serie contains all hydronic components which normally are located in the transformer box. The hydronic components are installed between the two coils (see picture) therefore the COMPACT version provides the same dimensions as the condensing unit of the SPLIT version does. Water connections on the rear side of the unit (see picture). Water piping max. distance app. 150 m* Capacity controlled chiller max. 150 m Fan coil unit (or any other kind of water coil) Leaving water temperature down to -5 C possible * Max. possible length depends on fan coil unit pressure drops and requested water flow rate.

System Diagram Split version HVS Digital is the latest generation of YORK s Air Conditioners for cooling and heating. These units use the Digital Scroll compressor technology that allows to adequate the capacity to the cooling or heating load. Thanks to this innovative technology our products reach many advantages for our customers. Energy saving up to 35% compared conventional chillers. High comfort because of the unit is capable to adjust the water outlet temperature in a ±0,5 C, thereby it is possible for the users enjoy always a comfortable ambient temperature. Absence of Electromagnetic Interference, compared a variable speed compressor, making the system easy and less sensitve. High reliability, as there is not necessary to use complicates electronic devices to get the right capacity. Not necessary to use buffer tank, thanks to the modulation control Not necessary to use glycol, as it is possible to use an intermediate transformer box as a remote evaporator. And many other advantages that you can discover by yourself using HVS units. DX piping (R407C), distance max. 20 m (i.e. total piping max. 40 m) Capacity controlled chiller Transformer box 20 m max. 150 m 5 m Max. height difference between condensing unit and transformer box: 5 m Water piping max. distance app. 150 m* (i.e. total piping length between Transformer box and furthest Fan coil unit max. 300m*) External heating system (Leaving water temperature max. 50 C) optional Fan coil unit (or any other kind of water coil) Leaving water temperature down to -5 C possible * Max. possible length depends on fan coil unit pressure drops and requested water flow rate. Split system overview HVS-Condensing unit e.g. YDCC972H HVS-Transformer Box e.g. YTB 972-V 1) Refrigerant connections 2) Water connections 3) 4) Pressure gauge 5) Safety 6) Water 7) Flow switch 8) 9) (s) 10) Air bleeding HVS-System Controller Valve Kit Indoor units: Standard Fan Coils High Wall units Cassettes Covertible consoles Blowers...

Dimensions and space requirements Transformer box YTB_522-V Transformer box YTB_972-V Ø 22 mm Ø 12 mm Water connections 1 1/2 threaded male Pressure gauge gauge Safety Ø 16 mm Water connections 2 threaded male Pressure Pressure gauge gauge Water Safety Water Air bleeding Flow switch Charge drain drain 800 1000 Casing Casing door at door at front 300 Air bleeding Magnetic Flow switch 1000 Charge drain 800 Casing Casing door at front door at front 300 Unit Water pipe connection Refrigerant tubing diameter Weight kg Unit Water pipe connection Refrigerant tubing diameter Weight kg YTB-522-V 1 1/2 threaded male 12 / 22 80 YTB-972-V 2 threaded male 16 / 28 95 Transformer box YTB_1732-V Transformer box YTB_2502-V Ø 18 mm tube mm tube Ø 18 Ø 16 mm Water connections 2 threaded male Water connections 2 threaded male connection Ø 18 mm Ø 16 mm tube Ø 16 Ø 18 mm Water connections 2 threaded male Water connections 2 1/2 threaded male connection 2x Air bleeding Pressure gauge Safety Air Air bleeding 2 2x heat Pressure gauge Safety 1200 Water s 1200 Water Magnetic Flow switch Magnetic Flow switch Charge drain 1000 Casing door at front door at front 300 Charge drain drain 1000 Casing door at front door at front 300 Unit Water pipe connection Refrigerant tubing diameter Weight kg Unit Water pipe connection Refrigerant tubing diameter Weight kg YTB-1732-V 2 threaded male 2 x 16 / 28 150 YTB-2502-V 2 1/2 threaded male 3 x 16 / 28 170

Dimensions and hydraulic connections Model YDCC / YDCH 522 (-C) Model YDCC / YDCH 972 (-C)

Dimensions and hydraulic connections Model YOCC / YOCH 762 (-C) Model YOCC / YOCH 1522 (-C)