Fan speed controller Type Saginomiya XGE

Similar documents
Fan Speed Controllers Type RGE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

M7100 Pressure Transducer

U5700 Submersible Liquid Level Pressure Transducer

M5200 Industrial Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Dual Pressure Controls

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

U5300 Industrial Pressure Transducer

ClimaSys Resistance heaters Selection guide

SMALL PRESSURE CONTROLS (DISC TYPE)

Safe Enclosure Cooling

Owner s Manual Therma-Stor II Heat Recovery System

SITESTAR CABINET DESCRIPTION

Thermostatic Expansion Valves Type TR 6

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

WATER, OIL, CONTAMINANTS: SEPARATION AND EVACUATION

U5600. Wireless Pressure Transducer SPECIFICATIONS

Sensor unit MC2 with analog output for Freon gases and refrigerants

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Thermostat KPU. Data sheet

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Thermoelectric Bath. Series HEB

Product Catalog VALVES

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

Performance Requirements for Air-Cooled Condenser

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

M5800 Pressure Transducer with Rotatable Display

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

DANFOSS OPTYMA PLUS INVERTER UNITS

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Heavy Duty Pressure Transducers Line Guide

Pressure switch KPU. Data sheet

Heavy Duty Pressure Transducers

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Thermoelectric Bath. Series HEB

OIL SEPARATORS APPLICATIONS

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

Danfoss gas detection units

GENESIS Indoor Air Conditioners

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

USER-MANUAL Tamson Cool Cube Immersion Cooler

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Room Temperature Sensors

D5100 Industrial Differential Pressure Transducer

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

M5800 Pressure Transducer with Rotatable Display

Life insurance for your electronics

Quality Enclosures. Service Excellence.

Gas cylinder scale Model GCS-1

Chargebuster Ion Gun Installation, Operation and Maintenance

AC Backward Curved Motorized Impellers

UV - flame detector dual fuel burners for intermittent burner operations

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

MSP300 Pressure Transducer

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

ExPolar Heating System

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

Snifter ATEX22 VERSION. User Manual. Distributor

USER AND MAINTENANCE MANUAL

HEB Series. Peltier-Type Thermoelectric Bath

Plug-in Base, Long Range Sensor E3B2

Illumination unit For sight glass level indicator Model LGI

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

NQ Series Portable Chillers

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

CR Series Command Relays

Retroreflective sensor with polarization filter

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

Recirculating Coolers

Check valve Types NRV and NRVH

1. TF Hermetic Reciprocating Compressor

HEB Series. Thermoelectric Bath

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

REF5-BB Undercounter Blood Bank Refrigerator

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Thermal Management Products & Accessories for Enclosures

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Table of Content

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

DESIGN & TECHNICAL MANUAL

Cabinet Cooler Systems

P266 Series Single-Phase Condenser Fan Speed Control

! WARNING. Before using product, read and understand instructions.

D5100 Industrial Differential Pressure Transducer

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

VA G 052 S

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

CHECK VALVES INSTALLATION

Installation Instructions

Transcription:

Data sheet Fan speed controller Type Saginomiya Fan speed controller stabilizes condensing pressure by changing condenser s fan speed. The controller reduces fan noise and saves energy in low ambient conditions. Widespread usage in refrigeration and air conditioning units. Extensive performance testing under different conditions and strict quality control procedures ensure trouble free operation for many years. Compact size, reduced weight and high degree of protection means that it can be mounted directly on refrigeration lines. Panel mounting also possible. Easy adjusting made by the turn of a screw situated on the top surface. Specially designed heat dissipation radiator ensures no overheating and extended lifetime. version for EC fan motors. Features Wide regulating Compact design Male or female pressure Easy and adjusting Simple and easy electrical Cut off type or Minimum speed type Fitted with an electro-magnetic suppression filter DCS (az) 208.03 DKRCC.PD.LC0.A2.02

Data sheet Fan speed controller Approvals CE in accordance to EMC directives, UL Function 00% 95% 0 Prop. 45% 35% Min. speed 230V @ 50Hz 230V @ 60Hz Output (V DC) prop. 6H0003.0 (bar / psi) Set point 6H0005.0 (bar / psi) Set point Fan speed controller keeps the condensing pressure at a steady level by regulating the speed of the AC/EC fan motors. When pressure is declining the controller decreases the output voltage changing the speed of AC/EC fan motor. The proportional is a non-adjustable pressure difference between max. and min. pressure where the regulation occurs. For min. pressure the controller can either operates with min. speed or completely cuts off the output voltage, depending on the type of the controller. saves energy and reduces noise by lowering the fan speed or cutting it off. Application example. Fan speed controller 2. Compressor 3. Evaporator 4. Expansion valve 5. Receiver 6. Condenser 6H0003.0 Fig. Typical refrigeration system using fan speed controller DCS (az) 208.03 DKRCC.PD.LC0.A2.02 2

Data sheet Fan speed controller Technical data Performance (EN 60770) Max. current 3A*) Min. current 0.2A Enclosure Max. working pressure Supply frequency IP65 47 bar / 68 psi 50 / 60 Hz Operating ambient temp. -20 55 C / -4 3 F Fluid temperature -20 70 C / -4 58 F Power supply Max. voltage output 200 240 V AC 7/6-20UNF female (with depressor pin) and male 95% of supply voltage for 50 Hz 45% of supply voltage for 50 Hz Cut off / Min. speed 35% of supply voltage for 60 Hz *) NOTE: can also be used for 4A rated fans provided the ambient temperature does not exceed 40 C / 04 F. Please contact regarding the maximum ambient temperature limits at ratings between 3A and 4A Input voltage 0 V DC Output 0 to 0 V DC Rated current ma Enclosure IP65 Max. working pressure 47 bar / 68 psi Ambient temperature -20 55 C / -4 3 F Fluid temperature -20 70 C / -4 58 F 7 6-20UNF female flare with depressor pin Ordering Mode SI Units Code ) -2C R22, R34a, 8 8 8 4.5 3.5 8 Cut-off Female 06H344-4C 9 0 25 6 4 25 Cut-off Female 06H340-4CB 9 0 25 6 4 25 Cut-off male 06H342-6C R40A*) 28 22 39 7 5 39 Cut-off Female 06H360-6CB R40A*) 28 22 39 7 5 39 Cut-off male 06H362-4M R22, R34a, 9 0 25 6 4 25 Min. speed Female 06H3240-4MB 9 0 25 6 4 25 Min. speed male 06H3242-6M R40A*) 28 22 39 7 5 39 Min. speed Female 06H3260 ) Code s available in Multipack. Please contact for code s available in Industrial pack. Mode US Units Code ) -2C R22, R34a, 6 6 26 65 5 26 Cut-off Female 06H344-4C 276 45 362 87 58 362 Cut-off Female 06H340-4CB 276 45 362 87 58 362 Cut-off male 06H342-6C R40A*) 406 39 566 0 27 566 Cut-off Female 06H360-6CB R40A*) 406 39 566 0 27 566 Cut-off male 06H362-4M R22, R34a, 276 45 362 87 58 362 Min. speed Female 06H3240-4MB 276 45 362 87 58 362 Min. speed male 06H3242-6M R40A*) 406 39 566 0 27 566 Min. speed Female 06H3260 ) Code s available in Multipack. Please contact for code s available in Industrial pack. DCS (az) 208.03 DKRCC.PD.LC0.A2.02 3

Data sheet Fan speed controller Ordering -2S-E R22, R34a, SI Units Code ) 8 8 8 4.5 3.5 8 Female 06H3245-4S-E 9 0 25 6 4 25 Female 06H3246-6S-E R40A*) 28 22 39 7 5 39 Female 06H3247 ) Code s available in Multipack. Please contact for code s available in Industrial pack. R22, R34a, -2S-E US Units Code ) 72 6 26 65 5 26 Female 06H3245-4S-E 276 45 362 87 58 362 Female 06H3246-6S-E R40A*) 406 39 566 0 27 566 Female 06H3247 ) Code s available in Multipack. Please contact for code s available in Industrial pack. 6H0006.0 E ective voltage (V%) Min. speed Cut o Min. Prop. Max. / Min. set point Max. set point (bar / psi) DCS (az) 208.03 DKRCC.PD.LC0.A2.02 4

Setting The easily accessible adjusting screw is situated on the top surface of. The direction to turn the screw for decrease or increase in the pressure is indicated by arrow markings next to the adjusting screw. Series 360 = turn -2-4 -6 approx. 0.8bar /.6 psi approx..5 bar / 22 psi approx. 2.5 bar / 36 psi Series 360 = turn -2SE -4SE -6SE approx. 0.8bar /.6 psi approx..5 bar / 22 psi approx. 2.5 bar / 36 psi Every turn of the adjusting screw corresponds to a specified change in the value. A punch hole on the adjusting screw helps keep track of the of turns made. Installation The is designed to be directly mounted onto the refrigeration line making the most of free space in a unit. In cases where space is even more limited, can be fixed onto a simple bracket (supplied as an accessory) and screwed to a panel. Code 06H302 -AE0 Panel mounting bracket Direct mount Panel mount Wiring and electrical Electrical of to the fan motor is simple and easy. With the use of a square quick connect plug, the is possible in 4 different directions, allowing many different machine configurations to accommodate, depending on the position of the fan motor and orientation needed for the electrical cable. For wiring, a simple diagram is embossed onto the surface and also indicated on the plug. Dimensions and weight ø66 mm / 2.59 in. Horizontal space: diameter of 66 mm / 2.59 in. Height: 90 mm / 3.54 in. (2 mm / 4.4 in. with plug fitted) Weight: 80 g / 6.35 oz 2 mm / 4.4 in. DCS (az) 208.03 DKRCC.PD.LC0.A2.02 5