Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

Similar documents
RangerNET Network Ready Constant Monitor Model CM2815

Ohm Metrics. Instruction Manual. Model CM400 Series. Continuous Workstation Monitors

A2CM2 Dual Wire Continuous Resistance Monitor

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower

FLT93 Installation, Operation and Troubleshooting Guide

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Bench Top Ionizer Installation, Operation and Maintenance

Alarm Tone Generator Model AG17

NT DUAL CHANNEL DISPLAY. User Guide

Beacon 800 Gas Monitor Operator s Manual

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

STEP-HEAR Activator (SH-220)

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Installation Manual COPYRIGHT NOTICE

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

LED LAMP: To turn on the LED Lamp, press the LIGHT BUTTON located on the front. Press again to turn off.

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Comfort Series Instant Hot Water System

Chargebuster Ion Gun Installation, Operation and Maintenance

LMA LINE MONITOR ALERT USER S MANUAL

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

Freeze Alarm. General Description VD-6300-MCS / VD-6301-MCS. Applications. Features. Specifications. Dimensions

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Universal Clamp Meter

CA5000 Liquid CO 2 Freezer Backup System

STATUS ALARM HISTORY ALARM RESET

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Remote Sensor Module: EB-RSM-01

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

KT-100 Door Controller

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Critical Environment Ionizing Blower. Model 5810i. User s Manual

Chargebuster Ion Gun Installation, Operation and Maintenance

Long Range Radio Alarm Transmitter

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

Mark 25 Ultrapure Water Conductivity Analyzer

WARNING Important Safety Information

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Pump-Up Controller MODEL 4062

EVO192 v3.0 Fire and Burglary What s New

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Voice Dialer Temperature & Power Loss Monitor VD-5100-TM / VD-5101-TM

Pump-Down Controller MODEL 4052

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

CO2 Sensor User and Installation Guide

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

WARNING Important Safety Information

WARNING Important Safety Information

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

Long Range Radio Alarm Transmitter

INSTALLATION INSTRUCTIONS

VX SERIES Wireless Thermostat with Occupancy Sensor

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Protocol Station Remote Alarm

RAM3 Remote Alarm Module

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Advantium 16 System Monitor

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

169MHz Telecare Devices Sensor Controller

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Delta P Plus Control

6502B RF Distribution

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

User's Guide. Pinless Moisture Meter. Model MO257

JENCO ELECTRONICS, LTD.

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

RK Combustible Gas Transmitter Operator s Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Installer Guide. WARNING Important Safety Information. 1 Specifications

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

Document No

User Guide. for the Beacon ProActTM 200 System

Carbon Monoxide Monitor and Retrofit Carbon Monoxide Monitor Kit W-2808/37027

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

RK Transmitter Technical Notice

D2E Duct Smoke Detector

Transcription:

O u t s t a n d i n g A l t e r n a t i v e s i n S t a t i c C o n t r o l T r a n s f o r m i n g T e c h n o l o g i e s, L L C Ohm Metrics Continuous Workstation Monitors Model CM1600 Instruction Manual

Contents 1 Description CM1600 1 Features 1 2 Operation Wrist Strap Indications 2 Mat Indications 3 GND monitor Indications 3 3 Installation Installation Instructions 3 Installation Diagram 4 Maintenance 5 4 Specifications 6 6 Service and Warranty 6

Ohm Metrics Resistance Monitor: CM1600 The Ohm Metrics' CM1600 Series dual conductor workstation monitor provides continuous monitoring of resistance for two wrist straps, two mats and two auxiliary grounds. The status are displayed using tricolor LED s on the front panel of the monitor and abnormal levels trigger an alarm to inform operators on the line. Utilizing lowvoltage, resistive loop technology, and dual conductor ground products, the CM1600 is an extremely sensitive and reliable ground monitoring for use in highly critical areas. Features: Monitors two wrist straps, two mats and two auxiliary grounds. Ultra-Low voltage for highly critical areas. Uses Dual Conductor Wrist Straps 3-color LED to indicate status of operator wrist-strap: HIGH, LOW, SAFE Normal voltage when wearing wrist-strap is 100mV. Open wrist-strap: 0.9V. Maximum mat voltage: 900mV Maximum machine voltage and current (Hard Grounding): 50mV, 0.2mA Human body voltage filtration 1

Operation The CM1600 monitors the grounding functions of two wrist straps, two workstation grounds and two auxiliary grounds and alerts users when levels are out of the set range. Alerts If any parameters exceed the preset high limits, the corresponding LED on the front panel of the monitor will change color from green (OK) to red (high warning) to indicate the abnormal situation. If the resistance is below preset low limit, the LED color will be yellow (low warning). An audible alarm will sound, in addition to the corresponding LED indicator when the resistance is in an abnormal state. For instant differentiation, a single beep will sound if the abnormal situation occurs on Station 1 whereas a double beep sound for Station 2. (LED indicators illustration of CM2800 front panel.) OP 1 and OP 2 - Grounding resistance of operators MAT1 and MAT2 - Grounding resistance of work surfaces G1 and G2 - Auxiliary Grounds 1. Operator Grounding The operator is grounded when the dual conductor wrist strap is plugged in to the jack labeled OP of the grey remote. The corresponding LED label OP will be GREEN if levels are normal. If the any of these parameters exceed preset high limits, the corresponding LED will turn RED and alarm will sound. If the resistance of the wrist strap is below preset low limit, the LED will turn YELLOW and alarm. If the wrist strap is not plugged into the remote terminal jack, the LED s of both OP will be off to indicate the stand-by mode. Factory set resistance limit is 1.8 megohm. 2

Since the CM1600 is designed with a Ultra-Low Voltage circuit, the measurement voltage of the grounding resistance of the operator body can be as low as 0.2V. Therefore, when the low resistance of the wrist strap is measured, it may be affected by the small Battery Effect existed between the contact of the human body skin and the wrist-strap metal stud. To avoid this, the low resistance measurement is disabled by default. If this measurement is turned on and the value is affected, you can reverse the direction of the wrist strap stud to resolve the influence. If the cable connecting to a wrist strap remote is unplugged or severed at either end, the monitor s audible alarm will sound, and the corresponding OP LED will turn red. Note: Each remote has two jacks labeled OP and AUX. The OP jack is monitored and AUX jack is not, but provides a grounding path for one more wrist strap. The status of AUX will not affect OP. 2. ESD Mat The CM1600 can monitor the ground resistance of two dissipative surfaces. When the resistance is within acceptable limits, the LED labeled MAT will be GREEN. If it exceeds preset high limits, the LED will change to RED and an alarm will sound. Factory limits are set at 100 meg ohm. Installation Before you install your device, check for the items below: 1 - CM1600 workstation monitor 2 - Remote Jacks 1 - Power Supply 2 - Telephone Cables 3 - Grounding Cables: FM1515, FM1515CM, FM1515NR Please carefully read the following instructions before proceeding with product installation. 3

1. Mount the monitor with Velcro in a location where alarm indicators will be visible and alarm will be audible to operator. 2. Install remote wrist strap terminals in a convenient location for operators to plug in wrist straps. 5. Plug the cable from the left remote to the OP1 port and the cable from the right remote to the OP2 port on the back of monitor. 6. Connect the bare end of the FM1515CM wire to the terminal on the back of the monitor labeled ESD GND and connect to GROUND. See wiring diagram. Mat Set Up: If no grounded ESD mats are to be monitored, connect a wire from both M1 and M2 terminals to the GND terminal on the back of the monitor and skip steps 8 and 9. 8. Connect the FM1515NR cord from the first grounded Mat to the terminal on the back of the monitor labeled M1. 9. Repeat step 8 with an additional FM1515NR if an additional mat is to be grounded. If not, connect a wire from M2 to GND to disable alarm function. Note: The work surface mats have to be connected to the CM1600 with zero Ohm wire. Using a wire with a 1M resistor may cause alarm. The FM1515NR is the provided zero Ohm cord and more can be purchased from Transforming Technologies. 10. AUX Ground Set Up: The CM1600 can monitor two additional grounded objects. Connect the item to the CM1600 with a zero Ohm wire and connect the item to ground with a One Ohm wire. 11. Disable one or both AUX Grounds by connecting a wire from the G1 or G2 port to the GND terminal. 12. Plug power supply into the PWR connector on the back of the monitor and into the power line. 4

Wiring Diagram Calibration and Periodic Testing The CM1600 never needs calibration. You can verify proper operation of the monitor by periodically testing the monitor with a resistance limit comparator box CM2015PV. Every CM1600 unit is calibrated at factory to meet the following criteria: Operator Resistance: ±10% Operator voltage: ±10%, or within 3 counts at 2V or less Mat resistance: ±10% Tool resistance: ±10%, or within 3 counts at 5Ω or less If you need to calibrate the operator resistance of your CM1600 unit, please contact Transforming Technologies Accessories The CM1600 comes with a line of optional accessories: 1. CM-Relay: Relay for external alarm 2. CM2800D: Digital display - shows real time results 3. CP3000: Parking Station for dual wire wrist straps 4. CYCLOPS Operator Presence Sensors 5

CM1600 Series Monitor Specifications Wrist Strap Low Resistance Alarm Limit: 1.8 megohm. Wrist Strap High Resistance Alarm Limit: 35 meg ohm. Mat (soft ground) Resistance Alarm Limit: 100 meg ohm. Typical Operator Voltage at 10M: Imposed Voltage on Body: max 0.1V (100mV) at standard version; can be preset at factory to max 0.025V (25mV) or max 0.8V (800mV) per customer request Max Mat Voltage (open circuit): 0.2V (200mV) Max Mat Voltage (alarm at 100M): 0.15V (150mV) Max Tool Voltage (open circuit): 0.01V (10mV) Max Tool Voltage (alarm at 10 Ohm): 0.4mV DC Power Supply: 7-15 VDC, 100mA. AC Input: 100-240 VAC, 1A. Temperature limits: 50 F (10 C) to 122 F (50 C) Adjustments: No serviceable components; see periodic verification tools Service and Warranty Transforming Technologies, LLC provides a limited warranty for the CM1600 series. All new products are guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Liability is limited to servicing (after evaluating, repairing or replacing) any product returned to Transforming Technologies. The company does not warrant damage due to misuse, neglect, alteration or accident. In no event shall Transforming Technologies be liable for collateral or consequential damages. NOTE: Wrist strap remotes terminal boxes are subject to mechanical wearing and considered to be consumable items. They have separate warranty of 6 months. T r a n s f o r m i n g T e c h n o l o g i e s, L L C 3719 King Rd. Phone: 419-841-9552 Fax: 419-841-3241 E-mail: info@transforming-technologies.com