The POWERTANK. Range by Pedrollo Distribution PACKAGED SOLUTION FOR BOOSTING WATER

Similar documents
The POWERTANK. Range A PACKAGED SOLUTION FOR BOOSTING WATER. by Pedrollo Distribution. powertank.co.uk

Pressure Boosting Solutions

Packaged pump solutions

A HOT WATER REVOLUTION

Performance on demand

CT range. of shower, bathroom and whole house pumps

A Hot water revolution

Performance on demand. Eliminate poor mains water pressure and flow problems. with mainsboost

Offering Total Water Solutions with New Products and New Brands UK Price List ( ) October 2017 (4th issue)

EVAPORATIVE COOLER PUMPS

marine horticulture recycling

TITAN SYSTEM ENGINEERING DATA SHEET TITAN HXS

HW3 Handwash Installation and Operating Instructions

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

pump solutions Full technical data sheets are available to download: For further advice on selecting the correct pump call:

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

Cooling system. Variable ventilation

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Cooling system. Variable ventilation

Please take time to carefully read through these guidelines before using your Kamco pump.

Panamatic. Midi & Mini. Installation instructions.

Autofill Wall Mount Boilers

Installation & Operators Manual

ZIP WATER HEATING 100 ZIP INSTANTANEOUS WATER HEATERS 106 INSTANTA WATER BOILERS 107 ZIP HYDROBOIL WATER BOILERS 108 ZIP HYDROBOIL PLUS WATER BOILERS

The POWERBOOST. Range GROUP. Clean Water Booster Sets

THERMAL STORE MAINS PRESSURE SYSTEM

Thermostatic bar mixer valve with adjustable head Installation guide

The Professional s Choice

SGS Condensing High Efficiency Gas-Solar Water Heater

INSTRUCTION MANUAL AMS WATER MANAGEMENT SYSTEM (AMS-WMS 230V) INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 1 of 15

SEALED THERMAL STORE

Installation & Technical Guide. Domestic & Commercial.

Broag Pressurisation equipment

The Classeq under counter range

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

EQUIPMENT MANUAL FOR ES25 PASS THROUGH DISHWASHER

Unvented Cylinder Brochure Issue 1 - Jan Creating Excellence, Building Reputation Unvented Water Storage From The Experts...

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

For use with approved Bathstore head kits. Installation guide. Viso Digital installation instructions Page 1

Installation, Operating and Servicing Instructions

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

Please take time to carefully read through these guidelines before using your Kamco pump.

SMART SHOWERS ELITE SP P0985 READ ME THIS IS A HIGH PERFORMANCE HIGH SPECIFICATION PUMP AND HAS PRECISE INSTALLATION REQUIREMENTS

Compressed Air Products

Please take time to carefully read through these guidelines before using your Kamco pump.

CI/Sfb. (53.5) Xh. March Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks

SHOWERBOOST BATHROOMBOOST HOUSEBOOST TECHNICAL WHY BUY A PUMP? Designed to boost the performance of a single outlet, ie a shower, tap or appliance.

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Extended Range. PRESFIX Packaged Pressurisation Sets AUTOMATIC MAKE-UP UNITS FOR SEALED HEATING AND CHILLED WATER SYSTEMS.

the electric heating company ELECTRIC BOILER HANDBOOK

Jetflush 4 Instruction Manual

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

For latest prices and delivery to your door visit MyTub Ltd

Vorton 11/18/36/55 2YEAR. GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

Installation & Operators Manual

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

What to expect from your water softener

THERMAL STORE MAINS PRESSURE SYSTEM

Saturn Booster PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND KEEP THEM FOR FUTURE REFERENCE

DOMESTIC PLUMBING PRODUCTS

Homeflow Product Brochure Issue 1 - Jan Creating Excellence, Building Reputation Unvented Water Storage From The Experts...

Multipoint. Unvented point of use hot water

Boost your water pressure. Shower, bathroom and whole house pumps

Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Installation procedure for the Wisy Rainwater system

SSA Serie. Features. Model code. Applications. Performance Curves. Operation Conditions. Materials

Installation, Operating and Servicing Instructions

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Installation Manual. Instrucciones de instalación y manual de usuario 1

6800 Design Envelope Booster. Technical overview

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

Submersible Supply Pump Packages

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

Standard Features & Accessories. Model Options

User, Installation and Servicing Instructions. Panther Static Hot Cupboards G1, G2 and G3 IS86 ECN1881

Pressurisation units & expansion vessels

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Mobile climate solutions

The Professional s Choice

INDIRECT SYSTEM FOR FROST LOCATIONS

The Classeq pass Through range

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

Cast Iron Boilers. G Series ( kW)

Where gas is not an option,

INSTALLATION INSTRUCTION

DOMESTIC & HOUSEHOLD. Designed for pumping from tanks, rivers and dams 79 l/min, 483 kpa TAPS: 8 NORMALLY $

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

UNVENTED WATER HEATERS. Water Heater Display Stand

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Powerstock Storage Tank

INTERCYL. INTERNAL EXPANSION EXCELLENCE

Installation Information User Manual

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Transcription:

The POWRTANK Range by Pedrollo istribution PAKAG SOLUTION OR OOSTING WATR

POWRTANK Increased Water Pressure & low ompact esign Quiet & Reliable ase of Installation ry Run Protection Marked Product Applications Include: omestic, ommercial, Agricultural & Industrial Need to boost your water pressure? There are many reasons for experiencing low water pressure problems including high demand, location and shared supply. The tank range is a self-contained cold water booster set specifically designed for use in domestic, commercial, agricultural & industrial applications where existing water pressure and flow is insufficient to meet demand. The range caters for multiple space and storage capacity requirements. Why do I need a tank and a pump? To increase water flow there must first be more water. If your mains supply is not meeting your requirements, then you need a break tank to store your own water supply ready for when you need it. This can then be pumped to your outlets on demand giving you a plentiful supply of water at the right pressure. Why can t I just fit a pump onto the mains? Water Authority bylaws prevent a pump being directly connected to the mains supply, so when your mains water pressure needs a boost, a break tank must be incorporated into the system. There is an exemption for pumps up to 1 ltr/min but this is not guaranteed and relies on your mains being capable of delivering this volume. To put this into context, a single shower typically requires between 9-1 ltr/min. Will it be noisy? All pumps create noise, but by incorporating an ultra-quiet running submersible pump within a tank unit, the tank range is about as quiet as you can get. Typical d of <d(a) Is it easy to install? Our all-in-one tank and pump unit is designed to remove the headache for installers. It is a packaged unit and therefore is fast and easy to install. See our Installation Guideline for step by step instructions. Where am I going to put it? The tank range has been designed to provide the end user with a variety of options in terms of water storage and usage requirements as well as availability of space. Typical installation areas include garages, plant rooms, utility rooms and kitchens. What is the difference between the fixed speed and the variable speed version? The fixed speed version has an automatic pump controller which provides the full performance of the pump on demand. The variable speed version has an intelligent pump controller that will supply a smooth flow of water to every outlet by maintaining constant pressure throughout your property, speeding up and slowing down the pump to suit demand. This ensures efficient operation of the pump leading to reduced energy usage and a smoother user experience. What size property will this supply? The tank range is scalable and additional capacity can be added for large properties or those with particularly poor incoming flow rates. We have designed the range to fit in all domestic and commercial properties (incoming flow rate and required usage must be taken into consideration). If you have a weak incoming water supply yet a high demand for water, you also have the option to link a slave tank to ensure you have enough stored water to meet demand. What if my tank runs out of water? The controller will turn off the pump if there is no water in the tank. It will automatically reset after a short delay allowing the water volume in the tank to recover. This pump protection feature ensures a long and happy life for the pump. Volumes All stated volumes are usable water volumes. If you require assistance to select the right system for your use please email us at sales@pedrollo.co.uk or call 01 100

7 POWRTANK ompact tank ompact: 1ltr The tank ompact has been specifically designed for smaller properties with low water pressure and flow and where space is at a premium i.e. apartments, cottages, townhouses. itting into the space of a standard kitchen unit, the tank ompact is a similar size to a washing machine so can be hidden away behind a cupboard door. The electronic controller automatically starts and stops the pump when a drop in pressure is sensed i.e. a tap is opened and closed. Key eatures Integral overflow weir Minimal installation required ry run protection with auto restart (time delay) 1ltr ompact ixed Speed 90mm 0mm 1ltr ompact Variable Speed onnection Size ½ SP 7mm 1 1mm 77 mm 80mm 80 77mm 1 ½ rain Off 1ltr ompact ixed Speed Option Variable Speed Option supply 0 volt, 0Hz 0 volt, 0Hz ontroller Presflo 1. supplied with ltr pressure vessel Steadypres M/T 07 supplied with ltr pressure vessel urrent Input. amp amp Mains able mtr x 1mm core fitted with amp fuse main plug mtr x 1mm core fitted with amp fuse main plug Tank Weight mpty 7 kg kg Tank Weight ull 1ltr = 1 kg plus weight of empty tank 1ltr = 1 kg plus weight of empty tank Access over Ø 190mm 18mm kw HP Q I/min 0 10 0 0 0 0 0 70 80 ixed Speed 0. 0.7 H Metres 0 8 0 18 11. Variable Speed 0. 0.7 H Metres 8..8 0. 7.. 9

POWRTANK Slimline tank Slimline: 00ltr & 00ltr The tank Slimline range can fit through a standard doorway. This makes it very convenient for new or existing properties as it can be easily fitted under a stairs, in a garage, or in a utility room. The slimline range is ideal for - bedroom houses, with poor water pressure and flow and where floor space is limited. It is electronically controlled through a flow switch unit which starts and stops the pump automatically when a tap is opened and closed. Key eatures Protective lid enclosure as standard ry run protection with auto restart (time delay) 00ltr Slimline ixed Speed 00ltr Slimline Variable Speed 00ltr Slimline ixed Speed 00ltr Slimline Variable Speed 180mm onnection Size 1190mm 870mm 10mm ½ SP rain Off 1" SP 8mm 00ltr Slimline 8mm 00ltr Slimline ixed Speed Option Variable Speed Option supply 0 volt, 0Hz 0 volt, 0Hz ontroller Presflo Multi with integral litre pressure vessel Steadypres M/T 07 supplied with 8ltr pressure vessel urrent Input. amp amp Mains able mtr x 1mm core fitted with amp fuse main plug mtr x 1mm core fitted with amp fuse main plug Tank Weight mpty 00ltr = kg 00ltr = 9kg 00ltr = kg 00ltr = kg Tank Weight ull 1ltr = 1 kg plus weight of empty tank 1ltr = 1 kg plus weight of empty tank Access over Ø 8mm 8mm A Q I/min 0 10 0 0 0 0 0 70 80 ixed Speed 0. 0.7 H Metres 0 8 0 18 11. Variable Speed 0.7 1 H Metres 1 9 7 0 9 1

POWRTANK Utility tank Utility: 00ltr, 70ltr The tank Utility pumping range is designed for domestic and light commercial use where there is low mains water pressure and where pressure fluctuates. It is electronically controlled through a flow switch unit which starts and stops the pump automatically when a tap is opened and closed. The Utility range is designed for areas where the floor space is not restricted. This range caters for a wider variation of tank options to suit a wider range of applications. Key eatures Protective lid enclosure as standard ry run protection with auto restart (time delay) 00ltr Utility ixed Speed 00ltr Utility Variable Speed 70ltr Utility ixed Speed 70ltr Utility Variable Speed 11mm 17mm 19mm 10mm onnection Size ½ SP rain Off 1" SP 70mm 00ltr Utility 70mm 70ltr Utility ixed Speed Option A Variable Speed Option supply 0 volt, 0Hz 0 volt, 0Hz ontroller Presflo Multi with integral litre pressure vessel Steadypres M/T 07 supplied with 8ltr pressure vessel urrent Input. amp amp Mains able mtr x 1mm core fitted with amp fuse main plug mtr x 1mm core fitted with amp fuse main plug Tank Weight mpty 00ltr = kg 70ltr = 9kg 00ltr = 0kg 70ltr = kg Tank Weight ull 1ltr = 1 kg plus weight of empty tank 1ltr = 1 kg plus weight of empty tank Access over Ø 8mm 8mm Project esigner ate arbery Pl lonakilty nterprise Park, lonakilt company ARRY PLASTIS PT SW /08/01 Title ST Rev. No: Rev. at arbery P All Use, xhibition or opying of rawing xp Plast Q I/min 0 10 0 0 0 0 0 70 80 ixed Speed 0. 0.7 H Metres 0 8 0 18 11. Variable Speed 0.7 1 H Metres 1 9 7 0 9 1

POWRTANK Utility tank Utility: 0ltr & 1000ltr The tank Utility pumping range is designed for commercial use on a larger scale where there is low mains water pressure and where pressure fluctuates. It is electronically controlled through a flow switch unit which starts and stops the pump automatically when a tap is opened and closed. The Utility range is designed for areas where the floor space is not restricted. This range caters for a wider variation of tank options to suit a wider range of applications. Key eatures ry run protection with auto restart (time delay) 0ltr Utility ixed Speed 0ltr Utility Variable Speed 1000ltr Utility ixed Speed 1000ltr Utility Variable Speed mm 108mm onnection Size 1mm ½ SP 1" SP 9mm 108mm 188mm rain Off 0ltr Utility 1000ltr Utility ixed Speed Option Variable Speed Option supply 0 volt, 0Hz 0 volt, 0Hz ontroller Presflo Multi with integral litre pressure vessel Steadypres M/T 07 supplied with 8ltr pressure vessel urrent Input. amp amp Mains able mtr x 1mm core fitted with amp fuse main plug mtr x 1mm core fitted with amp fuse main plug Tank Weight mpty 0ltr = kg 1000ltr = 7kg 0ltr = 0kg 1000ltr = 80kg Tank Weight ull 1ltr = 1 kg plus weight of empty tank 1ltr = 1 kg plus weight of empty tank Access over Ø 8mm 8mm Q I/min 0 10 0 0 0 0 0 70 80 ixed Speed 0. 0.7 H Metres 0 8 0 18 11. Variable Speed 0.7 1 H Metres 1 9 7 0 9 1

POWRTANK Rectangular tank Rectangular: 70ltr The tank Rectangular range is designed for houses and apartments where there is low mains water pressure and where pressure fluctuates. It is electronically controlled through a flow switch unit which starts and stops the pump automatically when a tap is opened and closed. The tank Rectangular 70ltr tank is designed for areas where height restrictions and access are an issue. Key eatures ry run protection with auto restart (time delay) 70ltr Rectangular ixed Speed 7mm 171mm onnection rain Off Size ½ SP 1" SP mm mm 70ltr Rectangular supply ontroller urrent Input Mains able Tank Weight mpty Tank Weight ull Access over Ø ixed Speed Option 0 volt, 0Hz Presflo Multi with integral litre pressure vessel. amp mtr x 1mm core fitted with amp fuse main plug kg 1ltr = 1 kg plus weight of empty tank 190mm Q I/min 0 10 0 0 0 0 0 70 80 ixed Speed 0. 0.7 H Metres 0 8 0 18 11. 7

POWRTANK Rectangular tank Rectangular: 00 & 00ltr The tank Rectangular pumping range is designed for domestic and light commercial use where there is low mains water pressure and where pressure fluctuates. It is electronically controlled through a flow switch unit which starts and stops the pump automatically when a tap is opened and closed. The Rectangular range is designed for areas where the floor space is not restricted but where height restrictions are an issue. Key eatures ry run protection with auto restart (time delay) 1 00ltr Rectangular ixed Speed mm 77mm 00ltr Rectangular Variable Speed 00ltr Rectangular ixed Speed 00ltr Rectangular Variable Speed 10mm 1190mm onnection Size ½ SP 0 710mm 710 800mm 1" SP rain Off A 00ltr Rectangular 0 00ltr Rectangular A 1 ixed Speed Option Variable Speed Option supply 0 volt, 0Hz 0 volt, 0Hz ontroller Presflo Multi with integral litre pressure vessel Steadypres M/T 07 supplied with 8ltr pressure vessel urrent Input. amp amp Mains able mtr x 1mm core fitted with amp fuse main plug mtr x 1mm core fitted with amp fuse main plug Tank Weight mpty 00ltr = kg 00ltr = 9kg 00ltr = 0kg 00ltr = kg Tank Weight ull 1ltr = 1 kg plus weight of empty tank 1ltr = 1 kg plus weight of empty tank Access over Ø 8mm 8mm Q I/min 0 10 0 0 0 0 0 70 80 ixed Speed 0. 0.7 H Metres 0 8 0 18 11. Variable Speed 0.7 1 H Metres 1 9 7 0 9 1 8

POWRTANK unded tank unded: 0ltr & 0ltr The tank unded pumping range is designed for commercial use where there is low mains water pressure and where pressure fluctuates. very tank unded tank benefits from a tank within a tank bunded construction, with the outer tank able to maintain a minimum of 110% of the volume of the inner tank. The inner tank acts as the primary storage container, whilst the outer tank acts as a fail safe in the event of a spill. It is electronically controlled through a flow switch unit which starts and stops the pump automatically when a tap is opened and closed. The unded range is designed for areas where the floor space is not restricted. Key eatures Protective lid enclosure as standard uilt-in electronic start/stop ry run protection with auto restart (time delay) 0ltr unded ixed Speed 0ltr unded Variable Speed 0ltr unded ixed Speed 0ltr unded Variable Speed 117mm onnection Size 178mm 11mm 100mm ½ SP 1"SP 7mm X X R1.0 rawing Revision rain Off 70mm 70 0ltr unded 0ltr unded company l ixed Speed Option Variable Speed Option supply 0 volt, 0Hz 0 volt, 0Hz ontroller Presflo Multi with integral litre pressure vessel Steadypres M/T 07 supplied with 8ltr pressure vessel urrent Input. amp amp Mains able mtr x 1mm core fitted with amp fuse main plug mtr x 1mm core fitted with amp fuse main plug Tank Weight mpty 0ltr = 9kg 0ltr = 9kg 0ltr =kg 0ltr = 100kg Tank Weight ull 1ltr = 1 kg plus weight of empty tank 1ltr = 1 kg plus weight of empty tank Access over Ø Internal 190mm, xternal 8mm Internal 190mm, xternal 8mm Q I/min 0 10 0 0 0 0 0 70 80 ixed Speed 0. 0.7 H Metres 0 8 0 18 11. Variable Speed 0.7 1 H Metres 1 9 7 0 9 1 9

POWRTANK AT tank AT : 10ltr The tank AT provides backflow protection for fluid category risks. Our system includes a type A air-gap and has a water volume of 10 ltrs. We supply this tank with a self priming jet pump to ensure smooth operation. The electronic controller automatically starts and stops the pump when a drop in pressure is sensed i.e. a tap is opened and closed. Key eatures Non-corrosive holding tank Integral screened overflow weir ry run protection with auto restart (time delay) Self Priming Jet Pump AT 00mm 00mm 70mm 10ltr AT ixed Speed 70mm 0mm onnection Size ¾ SP 0mm Wastepipe AT supply Pump ontroller urrent Input Mains able Tank Weight mpty Tank Weight ull Access over Ø ixed Speed Option 0 volt, 0Hz JRm1-N Presflo. amp mtr x 1mm core fitted with amp fuse main plug 1 kg 1ltr = 1 kg plus weight of empty tank N/A Q I/min 0 10 0 0 0 0 0 JRm1-N 0.7 0. H Metres 8.. 1 18. 1 1. 1 10 10

POWRTANK omponents Top Multi II low rate up to 80ltr/min Head pressure up to. bar Max liquid temperature 0o consumption 0.kW NKM / - N Pump low rate up to 80ltr/min Head pressure up to. bar consumption 0.kW Top Multi-Tech (Auto) low rate up to 80ltr/min Head pressure up to. bar uilt-in electronic start/stop ry running protection consumption 0.kW NKM / - N Pump low rate up to 80ltr/min Head pressure up to bar consumption 0.7kW Presflo Multi L display unit Adjustable cut-in feature ltr surge tank ry running protection with auto restart Resin bonded electronics Pressure Vessel ltr or 8ltr Stainless steel nipple 1 10 bar working pressure WRAS approved product Presflo L display unit 1. bar cut-in pressure ry running protection with auto restart Resin bonded electronics Wall racket Support for Pressure Vessel Adjustable arm length 1 connection Steady Pres L display unit nergy efficient ry running protection xcessively frequent starts Over-current protection Slimline rip Tray Suitable for 00/00ltr Slimline range 1" overflow connection Lift handles onversion Kit for ompact 1m flexible inlet hose, 1mm Aquavend, Speedfit connection 00mm flixible outlet hose, mm Aquavend, Speedfit connection HPVO 0mm VI self sealing trap with V adapter McAlpine lexcon 0mm flexible waste pipe 90º elbow 0mm, 100mm x 0mm waste pipe UV iltration low rate up to 70ltr/min at 0mJ/cm Ultra violet disinfection Includes micron pre-filtration 1" onnections 0 WATT Slave Tanks The tank is a single pump booster set for cold water storage with capacity options ranging from 1ltr to 1000ltr. y simply adding an additional 'slave' tank, water storage capacity can be increased. ompact Slimline Utility Rectangular 1ltr tank only OT SAL O THIS RAWING 1.. NOTS ALL ITMS TO TAGG WITH PS TAG STATING; PS, RAWING No, PURHAS ORR No. OR HANRAIL TAILS S PS RAWING; PS/A-L/HANRAILING/RAILA.. RMOV ALL SHARP GS AN URRS 00ltr tank only 00ltr tank only 1 00ltr tank only 0ltr tank only 70ltr tank only 1000ltr tank only 1 70ltr tank only 00ltr tank only 00ltr tank only 1 188 1 77 80 10 180 10 19 70 8 Please note that we have a policy of continuous product development and specifications may change from those shown 1 107 11 arbery Plastics Ltd.

Other Products in the Water oosting Range Here at Pedrollo istribution we know that everybody s requirements are different and the tank may not always be the correct option. We have a range of water boosting products that ensure we have a solution whatever your situation. Water oosting for Unvented Systems (Where you already have a Tank) Our range of single pump and controllers can be fitted in any unvented system where you may already have a cold water tank, or you would like to source your own. Water oosting for Gravity ed Systems (Vented) Our range of twin pumps and controllers can be fitted onto the hot and cold feeds to ensure equal pressure throughout your property. Water oosting for Unvented Systems with Good Pressure and Low low Our accumulators are a low cost option for properties with good pressure but low flow. These fill up with pressurised water from the mains when demand is low which provides a reserve of water when you need it. espoke Solutions uilt to Order If our standard offerings don t meet your requirements we have a comprehensive range of pumps, tanks and controls which can be combined to suit your specific application. The boost Range Pedrollo istribution introduces the POWROOST range of clean water booster sets for the supply of water for domestic, commercial, agricultural, industrial and municipal markets. LOW PRO U www.power-boost.co.uk Pedrollo istribution Ltd rossfield ort rossfield Road Industrial state Lichfield WS1 RJ t: 01 100 f: 01 1900 e: sales@pedrollo.co.uk w: www.pedrollo.co.uk www.powertank.co.uk Ref 19/01/17