ACP10 & ACP50 Security Systems

Similar documents
Security Alarm Systems

EC-P Zone Intruder Alarm System

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

The complete wirefree security alarm solution

Gen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS. Domestic applications

P Zone Expandable Hybrid Security System

MKTCTBLEFURTINC R001. Catalogue nd Edition

DS7400Xi Addressable Control/ Communicator

Excel-EN Conventional Fire Control Panel

Polycarbonate External Sounder & Strobe Unit

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

SI120 Guarto Easy I. Alarm system. Fire & Security Products

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

High-End Wireless Security

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Product Guide. Exclusively for Professional Installers. Designed and Manufactured in the United Kingdom

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Solution F2. Fire Alarm Control Panels one step ahead.

Integrated Security Solutions

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

System 800 Addressable Fire Detection & Alarm System

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Wireless security products

Addressable Fire Alarm Control Panel

>WIRELESS> ALARM SYSTEM CR200

OJD ITB No Attachment E Duress Alarm Equipment Specifications

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

VISTA 48DLCT HONEYWELL SECURITY

Installation Manual Premier 412/816/832. Issue 10

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

INTRUDER ALARM SOLUTIONS PRODUCT LIST 2012

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control/Communicator Installation Manual

SENTROL ZX400/ZX410. Security System Control. Programming

Integrated Security Solutions

Product Guide International Edition

GARDTEC 580. Installation Instructions

IC60 Sintony 60 Intrusion Control Panel

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

User Guide. Contents. About this guide. i-on Style Security System

THIS GUIDE SUPPORTS MATRIX 424 & 832 CONTROL PANELS

TrueAlarm Fire Alarm Controls

Flair 500 Series Annunciators

Watchguard WGAP864 User Manual

Proudly Designed and Manufactured in New Zealand. By Arrowhead Alarm Products Ltd

2200 and 2200L ALARM CONTROL SYSTEMS

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PERMACONN PM1030 Includes DI300. Installation Manual

INTELLIGENT FIRE ALARM CONTROL PANEL

security timeless design innovative products inspired technology

LS800S Intruder Alarm System. Engineering Manual

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

The leading manufacturer of award-winning security products

EasyLoader AV-2005 & AV-2008

Solutions that make the world a safer place. Product Guide

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

WIRELESS CONTROLS & DETECTORS

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Introduction. When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator instructions guide (Part No. Y6055).

Intelligent addressable fire alarm control panel

NX-148 LCD CODE PAD TABLE OF CONTENTS

IDS X-Series Installer Manual H Issued July 2013

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Contents. Glossary

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

CC408. Quick Reference Guide Solution 880

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Series. NX-4-EUR Control Panel. Installation manual

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Solution 880 Operators Manual. Issue 1.00

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

ID50series. intelligent fire alarm panels

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

M800, M800iD Plus, M1000 and M3000. User's Guide

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

PCX 46 App Programming Reference

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions


CC488. Quick Reference Guide Solution Ultima 880

LifeAlarm Fire Alarm Control Panels

English. Italiano. Português. Françias. Español

Installation Instructions

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

intelligent fire alarm ID60series panels

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

Security Solutions. Alarm & CCTV Systems. Core System Range

Installation Manual RINS1211-4

System Overview. PC4020 v3.3

DYGIZONE GJD910 Lighting Controller & Enunciator

Transcription:

ACP10 & ACP50 Security Systems

System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel is an advanced intruder alarm system with 10 on-board zones and on-board multi format communicator. The system is ideally suited to domestic installations. For larger application the ACP50 can be expanded to 50 zones using the 10 zone expansion modules (AEX10). The system supports 5 partitions that can be used for multi-area and multi-tenant applications. The ACP50 also supports a 4 channel speech dialler and voice prompts which can be recorded via a touch tone telephone or by using the AlcoUDL software. Both systems support either LCD or LED remote keypads. Other features include: 10 programmable on-board zones 5 programmable outputs (1Amp rated) On-board communicator/modem Local or remote upload/download Advanced system diagnostics 1.5 Amp switched mode power supply Two communication ports for accessories etc Loudspeaker output Selectable battery charging rate Real time clock Two-wire smoke detector support Flash upgradable

Remote Keypads and Expanders LED (7 Segment) Remote Keypad The LED keypad features a dual 7 segment display for displaying zone status and system fault messages. A set of dedicated system status LEDs for AC, Ready, Armed, Trouble, Bypass, Alert and Alarm are also provided. Other features include: 4-wire connection using standard 4-core alarm cable Internal sounder Backlit keyboard LCD (40 Character) Remote Keypad The LCD keypad features a 2 x 20 character blue display for showing all zone status and system fault messages. A set of dedicated system status LEDs for AC, Trouble and Alert are also provided. Other features include: 4-wire connection using standard 4-core alarm cable Internal sounder Backlit keyboard AEX10 Zone Expansion Module The AEX10 is connected to the control panel bus and provides 10 programmable zone inputs and 10 programmable outputs. Other features include: 4-wire connection using standard 4-core alarm cable Internal sounder External loudspeaker connection, with programmable volume Engineer keypad port Upload/Download AlcoUDL Upload/Download Software This Windows based software can be used to remotely or locally program and diagnose the Alco range of security systems. Features include: Simple intuitive user interface Local or remote via modem Advanced system diagnostics System audit trail Remote servicing

Specifications ACP10 ACP50 On-board zones 10 Expandable to Fixed 10 at zones 50 Zone wiring Programmable per zone Outputs 5 - fully programmable and supervised, switched -ve @1 Amp Part-Sets 3 Partitions 1 5 Number of keypads 4 6 Number of Expanders 0 4 Number of users 10 50 Event log 250 500 Power supply 1.5 Amp SMPS Standby battery 7Ah EN 50131-1 grade 2 On-board Communicator Yes Speech dialler 4 Channels 8 Channels Voice prompts 10 15 Upload/Download Remote & Local Multi-Language Support No Yes 280 x 255 x 95mm 975g LED Remote Keypad Display Dual 7 segment green LED Dedicated Status LEDs Green: Power, Ready, Armed; Yellow: Trouble, Bypass; Red: Alert, Alarm 130x102x27mm 190g LCD Remote Keypad Display 2 x 20 white characters on Blue LCD Dedicated Status LEDs Green: Power; Yellow: Trouble; Red: Alert 102x130x27mm 200g AEX10 Zone Expander Zone inputs 10 - fully programmable Outputs 10 - fully programmable, switched -ve @100mA Sounder Internal piezo and external loudspeaker connections 136 x 174 x 36mm 230g

IR100 and IR200 PIR Detectors Alcosec s state of the art IR100 and IR200 PIR detectors have been designed to comply with EN 50131-2-2 Grade 2. Featuring superior electronics and leading edge design, the IR100 and IR200 detectors are designed to satisfy both the most discerning of end users and the most demanding of installers. The IR100 detector has been designed for superior reliability and performance in cost sensitive domestic installations whereas the IR200 detector includes additional features to aid installation and give added flexibility. Features 15m Adjustable Range Temperature Compensation Digital Pulse Count Sealed Optics Adjustable Mounting Height High RF Imunity Tamper-proof Mounting Bracket * Remote LED Diable * Selectable Alarm/EOL Resistors * EN 50131-1: Grade 2, Class II EN 50131-2-2: Grade 2, Class II * IR200 Only

VS1 Vibration Sensor Alcosec s VS1 intelligent perimeter protection devices provide exceptional performance, allowing detection of intruders prior to entry of the protected area, thereby providing the ideal solution for confirmed alarm systems. Features Digital Vibration Detector Fully Adjustable Sensitivity Tri-Colour Detection LED LED Disable Input Gross Attack Indication EN 50131-1 Grade 3 Microprocessor Technology Comfort LED Indication Digital Signal Processing Selectable Latching / Non-Latching

ES100 and ES200 External Sounders Alcosec s external sounders have been designed with an exceptional array of features to meet the requirements of the most challenging installations. With genuine EN 50131-4 Grade 3, a rugged polycarbonate construction, choice of single or twin Piezo Sounders and IP65 sealed electronics, Alcosec sounders are the sounders of choice for the most discerning professional installers. Features Single & Twin* Piezo Sounders Local and Remote Test Screw*,LidandWallTamper IP65 Sealed Electronics Polycarbonate Construction Maximum Strobe Visibility 109/115db* Volume * ES200 Only Not available in the UK True EN 50131-4 Grade 3 Selectable SAB/SCB Mode Microprocessor Technolgy Low Current Mode Twin Alternating LEDs Pre-alarm Engineer Warning Engineer Hold-off Mode