RADIOLOGICAL SURVEILLANCE & ALARM MANAGEMENT SYSTEMS

Similar documents
For Complete Fire and Gas Solutions

Protect your investment with Safety Manager

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions

GasGard 100 Control System

Laboratory Impex Systems Ltd

SUPREMATouch. Modular Fire & Gas Detection System

APPLICATION DATA SHEET

Advanced FireAlarm Panel 1-4Loop

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

DATAssure. Laboratory wireless alarm & monitoring system

SUPREMATouch. Modular Fire & Gas Detection System

Process Alarm Solutions

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

RAYCHEM NGC-30 COMPONENTS

REMOTELY OPERATED STENCH GAS RELEASE SYSTEM. Front Panel View Remote Activated Stench Gas Release System 240 Volt AC Supply

Safety Instrumented Systems The Smart Approach

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

/8 DIN Level Indicator

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

CCU Family of Modules

explosion protection automation global partner of the process industry

Different types of Fire Alarm System

PcVue Solutions. PcVue Solutions

MULTIFUNCTIONAL SYSTEM

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Compact Product Suite Compact HMI 6.0 Overview ABB

Substation Monitoring System

D3 Wireless temperature alarm & monitoring system family. tek-troniks

When reliability is vital. Alemite Carbon Shield TM Systems deliver

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

Proven Technology for Safety Instrumentation Systems

Trusted fault tolerant technology

APPLICATION DATA SHEET

PRODUCT REVIEW Honeywell HC900 Hybrid Vacuum Furnace Control System

Building system automation. How to use

Honeywell SLATE ICM Platform

Vykon. Security. Integrated Access Control. Web enabled security management built on the Niagara Framework

NGC-20 LOCAL CONTROL CENTRAL MONITORING

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

Fire and Gas Monitoring Panel ST7-HV

Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Functional Safety Solutions

RS485 MODBUS Module 8AI

16 Zone Voice Evacuation VA & PA Sound System

UltraSync Modular Hub

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

ACTIVE INFRARED BARRIER

PROCESS CONTROL COURSES

Touchpoint Pro Flexible Gas Control System

Access Control for. Part 3 of 4. Brought to You by. Presented by Video Security Consultants

DIPL Solutions and Services

Experion LX Direct Station Specification

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

AUTROSAFE 4 A new level in interactive fire detection systems

Leak Detection - Application Note

Reactor Protection Systems for the Replacement Research Reactor, ANSTO

SUPREMATouch Modular Fire & Gas Detection System

Industrial Strength Leak Detection

2015 Honeywell Users Group Europe, Middle East and Africa

COST-EFFECTIVE SCADA SYSTEMS

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Field Products. Experion LX. Proven DCS for a wide range of industrial applications

The Next Generation Machine Protection System

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

System 9000TS Sequence of Events Recorder

Power & Instrumentation BU

Fire alarm system EBL512 G3

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Note that the cable must be handled with great care to avoid damages to the cable during transport etc.

Panel Mounted Fault Annunciator Series

AIS750 Series Alarm Annunciator

The EN54 Part 2 & 4 Fire System

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

SAUTER EY-modulo 5. The complete building management solution.

System 9000TS Sequence of Events Recorder

Alfa Laval Touch Control

Industrial Grade Gas Detection Detecting The Difference

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

PD alarm system brings peace of mind in Malta

C-Bus Application Note. Function Rooms and Ballrooms. Overview

SAUTER EY-modulo 5. The complete building management solution

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Introduction. Introduction

TRACENET TM TN SERIES

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

DynAMo Alarm & Operations Management

Now Compa ble With. VL Touchscreen Alarm. Crafted Touchscreen Security System that Revolutionizes Your World. illi tl C

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

AUTROSAFE. An interactive fire detection system for larger vessels

HRX3000. Technical Manual

DCS-100. intelligent damper control & monitoring system

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

SOLAR POWER PLANT AUTOMATIO

Transcription:

RADIOLOGICAL SURVEILLANCE & ALARM MANAGEMENT SYSTEMS Complete Remote Monitoring Solutions Automated Alarm Processing Historical Event Tracking

O U T L I N E Corporate Overview The Remote Monitoring Specialists OMNIFLEX has been designing and manufacturing electronic products and systems for remote monitoring and control since 1965. Why Omniflex RSS? For companies that need to monitor radiation levels to meet the legal nuclear safety standards and provide protection for personnel, and who are dissatisfied with the quality of the information available for their risk management and reporting, Omniflex RSS (Radiological Surveillance System) provides REAL-TIME information on SCADA, HMI, and web based remote monitoring using Datatodesktop (D2D) solutions. Unlike DCS or manual methods of reporting Omniflex have assembled a well proven end to end solution that does not require in-house technical expertise or large capital budgets. monitoring and logging of these alarms. An investment in products that carry such a large responsibility requires confidence in our track record and the reliance of some of the world s leading nuclear industries, such as BNFL, Sellafield Ltd, Dounreay, Magnox, Westinghouse on Omniflex technologies, is sufficient testimony. Don t ask us ask our loyal customer base. www.omniflex.com your link to reliable solutions in radiological surveillance networking and abnormal alarm management History Over the last 25 years Omniflex has designed and delivered products and systems for the Nuclear Industry specialising in Alarm Annunciators, Alarm/Event Management systems, Multiplexers and Radiological surveillance systems. As part of the original British Nuclear Fuels Limited's standard ILW design standards, Omniflex was chosen to supply both radiological surveillance and alarm/event management systems. A number of interface modules have been developed for the well proven Maxiflex I/O system and Teleterm M2 product range to provide interfaces to any of the existing or new ranges of Harwell or Lab Impex Alpha, Beta and Gamma radiation monitors. The ILW design also includes the supply of an independent alarm management system, which is designed to provide real-time alarm/event monitoring. Omniflex Maxilarm, Omni 4000 and Omni 8/16C (IEC61508 SIL EMPHASIS approved) Alarm systems were chosen to provide this critical

S Y S T E M Radiological Surveillance The Maxiflex System The Maxiflex I/O system is designed to provide a cost effective and extremely flexible means of interfacing any radiation monitor to the building or site-wide SCADA system. Maxiflex is modular in design and can accommodate any type of digital or analogue signal, together with distributed intelligent communications modules. The Maxiflex intelligent radiation monitor interface modules makes it an ideal system to distribute around the building or site. Maxiflex has a very powerful communications infrastructure supporting Conet internetworking technology. A mix of communications media may be applied to suit the site including Conet/c (any grade of 2 core cable up to 10kms without the need for repeaters), Modbus, Ethernet, PSTN and Radio. This range of specially developed Radiological Monitor interfaces allow existing infrastructure to be reliably and cost effectively networked. Harwell Monitors 3230 & 3280 These Alpha/Beta monitors provide a high speed pulsed stream output using RS422 voltage levels, for which a 4 channel Maxiflex module (Model M1711A) was developed. This module will enable up to 4 monitors to be hardwired. Up to 15 of these modules can be fitted to one Maxiflex system with no limit to the number of Maxiflex systems that can be inter-connected. Lab Impex Monitors CMS 2000 These Alpha/Beta/Gamma monitors provide a RS485 network output, for which a LabImpex NIM (Network Interface Module) M1585A was developed. This module will enable up to 32 monitors to be inter-connected on the same RS485 network. Up to 15 of these modules can be fitted to one Maxiflex system with no limit to the number of Maxiflex systems that can be interconnected. Harwell Monitors AB96, G64, ICAM These Alpha/Beta/Gamma monitors provide either a high speed pulsed stream output using RS422 voltage levels for which a 4 channel Maxiflex module (Model M1711A) was developed or an RS485 network output for which a Harwell NIM (Network Interface Module) Model M1588A was developed. The Harwell NIM will enable up to 32 monitors to be inter-connected on the same RS485 network. Up to 15 of either of these modules can be fitted to one Maxiflex system with no limit to the number of Maxiflex systems that can be interconnected. Building Evacuation Logic Omniflex also provides the Maxiflex evacuation logic system which connects to the RSS network. All alarms are monitored on the entire system from both the hardwired alarms from the monitors as well as the alarms generated within the SCADA system for verification. The Maxiflex Evacuation node then drives volt free relay outputs depending on the % of standing alarms and groups to the site evacuation system to ensure that under a building radiation alert condition all personnel are safely evacuated. Other Equipment The Teleterm M2 product range now offers very cost effective distributed gateways to all the new monitors. The development of custom protocols and interfaces for third party equipment. It is likely that Omniflex has already implemented a protocol similar to your next special application, and can assist with a costeffective integrated solution.

S Y S T E M Alarm & Event Management Independent Alarms In many instances (such as the BNFL ILW design) there is a requirement for an independent realtime Alarm management system. The Maxiflex system is designed to take in the hardwired High and Trip Alarms from each monitor. These alarms can be individually timestamped by the Maxilarm alarm handling module s real-time clock at source, and the alarms displayed to the operators on Omniflex' Omni 4000 PC based alarm handling package. These systems are widely used across many Nuclear sites. Omniflex range of independent alarm systems such as the Omni 8/16C range, can also be integrated to provide independent backup for critical alarms, ensuring the appropriate levels of safety in the system can be achieved. These systems have now been successfully individually assessed for use in IEC61508 SIL applications through the EMPHASIS program. Time Stamp at source In large distributed systems, it can take a finite time for alarms and events occurring on a site to propagate to the SCADA system. In wide area applications, this time can be significant. A common practice is to time stamp these events at the SCADA system. This can cause loss of valuable resolution in establishing the order of events on a site. The Maxiflex system can timestamp alarms at source, and pass these events with their original time stamp to the SCADA for logging. This allows the resolution of alarm occurrences to be kept in the order of milliseconds.

S Y S T E M The Total Solution SCADA Omniflex Engineers have vast experience in the design and configuration of SCADA systems and have successfully implemented systems using most of the world leading brands of SCADA software. OPC Servers and other open industry standard interfaces are available for integrating the Maxiflex system to wide range of third party Supervisory Systems. SCADA solutions are designed to provide a complete building or site-wide overview of every monitor. This enables an operator to keep an overview of the entire system, but to quickly zoom through the individual buildings and rooms down to individual monitors, all from the central control point. Web Browser Monitoring The future monitoring requirements of many of these sites, buildings and facilities can now benefit from the ability to be able to do this from a web browser on any PC using Omniflex s D2D (Datatodesktop) service providing the capability to monitor the data from anywhere very cost effectively. Sytem Integration Omniflex can provide you the complete solution including PC Servers, workstations, printers, network servers as well as project management, design and build of all node panels, configuration, testing, commissioning, and ongoing maintenance. References We are proud of the projects in this specialised area that we have successfully completed. Ask us for a reference list.

A R C H I T E C T U R E Radiological Surveillance& Protection Systems

A R C H I T E C T U R E Alarm & Event Management

B E N E F I T S The Total Solution Integrate Radiation monitors from different manufacturers Integrate existing radiation monitors into SCADA or Web based monitoring solutions regardless of age Future proof modular design (e.g. Future Radnet support) Take full advantage of the extensive Maxiflex and Teleterm M2 capabilities: High Isolation Analogue and Digital Monitoring Optional IEC61131 PLC Control Real-time alarm/event management Low cost CONET networking up to 10km on twisted pairs Inter-networking for wider area solutions Integrated datalogging and multiplexing Web based monitoring capability Solutions by Design Harwell, Icam, Lab Impex, CMS2000, ifix Intouch, Factorylink, Panorama and Radnet are the registered trademarks of their respective owners. Available in soft copy as BRRadR08.pdf Omniflex Pty Ltd 2012