Programmable Outlet Thermostat. User Manual. Version 1.5s. Inkbird Tech. Co., Ltd.

Similar documents
Plug-n-Play Humidity Controller. IHC-200 User Manual. Version 1.3s. Inkbird Tech. Co., Ltd.

PID Temperature Controller. ITC-100 User Manual. Version 2.0s. Inkbird Tech. Co., Ltd.

5 Parts. The Manual Is Divided Into. 1 Quick Gide to Use. Part. Part 2 Temperature Controller manual. Part 3 Programmable Temperature

WH7016E Thermostat Product Manual

Installation Manual for Hot Yoga Studio Electric Radiant Heating

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

JDDT1 - Single Stage Digital Thermostat

Installation and Operations Manual

Digital Non-Programmable

Uponor Comfort-E Thermostat Dig. Prog Set T-86 INSTALLATION AND OPERATION MANUAL

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

Installation and Operating Manual

Comfort System T-21-P Touchscreen Thermostat Installation Manual

T-32-TS Touchscreen Thermostat. Installation Manual

Refrigerated Incubator Model and Operating Instructions

Thermostats. Digital Programmable. GEAppliances.com

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Temperature-Relay TR210

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

User Manual THR870CUK Programmable Thermostat

MD-MINI Dry Bath. Instruction Manual

SC Installation, Operation & Application Guide

SAT- 3 Installation Setup Guide

INSTALLER S & OWNER S MANUAL

Model: Touch-RS. 1 Touch-RS

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

WILLHI WH1436H Digital Humidity Controller Manual (NEW VERSION)

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

PL-1 Thermostat User s Guide

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OPERATING INSTRUCTIONS

INSTALLER S & OWNER S MANUAL

SC Installation, Operation & Application Guide

Please read this manual carefully before installation and use.

Model: Available in : Sapphire Black and Glacier White. 1 Series

KM300 Carbon Monoxide Detection System Installation Manual

Model: PRT-TS / PRT-NTS

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

SC Installation, Operation & Application Guide

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Owner s Manual MODEL 8555

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

IMPORTANT SAFETY INFORMATION:

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

WARNING Important Safety Information

User Guide ems25plus. Page 1. Normal operation. Product interface

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

Analog Room Pressure Monitor RPC Series

Air Pump Up to 800 gallons

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Prime Tower. Inline Chiller. Instructions for Models #2645,2646

ELECTRONIC THERMOSTAT

WARNING Important Safety Information

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

15,000 BTU Portable Air Conditioner

WARNING Important Safety Information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

CT500 Electronic Thermostat

FRUIT RIPENING CONTROLLER USER MANUAL SZ-FR INDIA

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Installer Guide. WARNING Important Safety Information. 1 Specifications

Instruction Manual Item No.: V~, 60Hz

WARNING Important Safety Information

SC Installation, Operation & Application Guide

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

WHYNTER 11,000 BTU DUAL HOSE PORTABLE AIR CONDITIONER

13500 BTU RV Air Conditioner Installation and Operating Instructions

SC Installation, Operation & Application Guide

Model: Slimline-N. 1 Slimline Series

Instruction Manual Item No.: V~, 60Hz

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

Instruction manual. Remote control electric IR HEATER

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Portable Ceramic Space Heater

Remote Sensor Module: EB-RSM-01

Portable Space Ceramic Heater

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

GEYSERWISE INSTRUCTION MANUAL

LABORATORY ILLUMINATED FLOTATION BATH

Model 5190-F Temperature/Humidity Probe

Prime Chiller 1/10th HP Chiller

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

User Manual THR842DUK Wireless Digital Thermostat

Transcription:

Programmable Outlet Thermostat ITC-310T User Manual Version 1.5s Copyright Copyright 2016 All rights reserved. No part of this document may be reproduced without prior written permission. Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete; however, the contents of this document are subject to revision without notice. Please contact Inkbird to ensure you have the latest version of this document.

Contents 1. Overview... 3 What is ITC-310T?... 3 Main features... 3 Safety Precautions... 3 2. Specification... 4 3. Keys Instruction... 5 4. Key Operation Instruction... 6 4.1 Enquiry Set Point... 6 4.2 How to Set Parameters... 6 4.3 Setup Flow Chart... 7 5. Menu Instruction... 8 5.1: Temperature setting (TS, HD, CD)... 9 5.2 Alarm High/Low Limit Setting (AH, AL)... 10 5.3 Compressor Delay (PT)... 10 5.4 Temperature Calibration (CA)... 10 5.5 Display in Fahrenheit or Centigrade unit (CF)... 11 5.6 Time -Temperature Parameter Setting (TR, UT, STA, ST1~ST6, HT1~HT6)... 11 5.7 Cycle and Automatic Mode (MD, AT)... 11 6. Error Description... 12 Sensor fault alarm... 12 Over-temperature alarm... 12 7. Technical Assistance and Warranty... 13 7.1 Technical Assistance... 13 7.2 Warranty... 13 2

1. Overview What is ITC-310T? ITC-310T is dual-relay, programmable outlet thermostat, which can auto-execute to control 6 periods times with different temperatures based on its timer function. The ITC-310T is mainly used to control temperature during fermentation process of beer and wine brewing, also widely used in home brewing, aquarium, pet breeding, hatching, barbecue, boiler temperature control, geothermal temperature control, heating pump constant temperature cycle, strain culture fermentation, seed sprouting, electric heating, electric oven, over-temperature protection and automatic temperature control system of all kinds of electrical equipment, etc. This product has Plug and Play design with dual relay, be able to connect with refrigeration and heating equipment easily to realize ideal temperature control. It s equipped with dual LED display, and offers display options of Centigrade and Fahrenheit, enabling more humanized temperature control. With large output power 1,200W (110V) /2,200W (220V), it s suitable for most applications. ITC-310T is designed with compressor delay protection for refrigeration, high and low temperature alarm, and sensor fault alarm, which makes the temperature controller more safe and reliable. Functions such as temperature calibration, separately set differential for refrigeration and heating, enable more accurate temperature control. Main features Programmable, 6 temperatures in 6 periods of time; Plug and play design, easy to use; Dual relays, heating and cooling outputs; F / C temperature display; Easy to set, PV and SV dual display windows; User calibration; Delay protection of refrigeration control; Can set high and low temperature alarms; Alarm when over-temperature and sensor error. Safety Precautions Ensure the product using within the specification. Do not touch the terminals at least while power is being supplied. Doing so may occasionally result in injury due to electric shock. Do not allow pieces of metal, wire clippings, or fine metallic shaving or filings from installation to enter the product. Doing so may occasionally result in electric shock, fire, or malfunction. 3

Do not use the product where subject to flammable or explosive gas. Otherwise, injury from explosion may occasionally occur. Never disassemble, modify or repair the product or touch any of the internal parts. Electric Shock, fire, or malfunction may occasionally occur. If the output relays are used over their life expectancy, contact fusing or burning may occasionally occur. Always consider the application conditions and use the output relays within their rated load and electrical life expectancy. 2. Specification Temperature Control Range -50~120 /-58~248 Temperature Resolution 0.1 / 0.1 Measuring Accuracy ±1 (-50 ~ 70 ) / ±1 (-58 ~ 158 ) Temperature Control Mode Timing Range Periods of Time Cycle Setting Input Voltage On/Off Control, Heating and Cooling 1~999 (min/hour/day) Max: 6 periods 1-999 times cycle, or 00 infinite cycle 100 ~240VAC, 50Hz/60Hz Current: Max.10A Control Output Voltage: 100~240V AC Power: Max.1200W(110V)/2200W(220V) Alarm Sensor Type Sensor Length Relay Output High and Low Temperature Alarm NTC Sensor(including) 2m / 6.56ft Cooling(10A,100-240VAC) Heating(10A,100-240VAC) Input Power Cable Length 1.5m ( 5ft ) Dimension Operating Ambient Temperature Storage Condition Warranty Main Body: 140x68x33mm (5.5x2.7x1.3 inch) Socket (US Version): 85x42x24mm (3.3x1.7x1.0 inch) Socket (EU Version): 135x54x40mm (5.3x2.1x1.6 inch) Socket (UK Version): 140x51x27mm (5.5x2.0x1.0 inch) -30~ 75 / -22~ 167 Temperature: -20~ 60 / -4~ 140 Humidity: 20~85% (No freeze or moisture condensation) 1 Year 4

3. Keys Instruction 1 PV: Process Value. Under running mode, display current temperature; Under setting mode, display menu code. 2 SV: Setting Value. Under running mode, display setting temperature; Under setting mode, display setting value. 3 Heating Indicator Lamp: light on, heating start working. 4 Cooling Indicator Lamp: Light on, cooling start working; Light flicker, status of compressor delay. 5 SET key: press and hold SET key for 3 seconds to enter menu for function setting, press and hold SET key for more than 3 seconds, then quit and save the settings during the setting process. 6 INCRESE key: under running mode, press INCREASE key to inquiry remaining time value; under setting mode, press INCREASE key to increase value. 5

7 DECREASE key: under setting mode, press DECREASE key to decrease value; 8 Heating Device Socket: for heating output. 9 Cooling Device Socket: for cooling output. 4. Key Operation Instruction 4.1 Enquiry Set Point: When controller works normally, short press key once, then displaying remaining time value; 4.2 How to Set Parameters When controller works normally, press and hold SET key to enter into the parameter setting mode, indicator lamp of SET will on, PV window displaying the first code TS of menu, while SV window displaying the related setting values. Press SET key to page down the menu then displaying the codes of menu, press or key to change the current parameter values. After setting, press and hold SET key for 3 seconds at any status to save the parameter correction and return to the normal displaying mode of temperature. During setting, if there is no operation for 10 seconds, system will quit the menu automatically and return to the mode of normal temperature displaying without saving the parameters modification. 6

4.3 Setup Flow Chart 7

5. Menu Instruction When TR=0 Symbol Code Function Setting Range(C/F) Default Setting(C/F) TS Temperature Set Value -50~120 /-50~248 25 /77 HD Heating Differential Value 0.3~15 /1~30 2.0 /3 CD Cooling Differential Value 0.3~15 /1~30 2.0 /3 AH Alarm High Limit -50~120 /-50~248 90 /200 AL Alarm Low Limit -50~120 /-50~248-40 /40 Remarks Note1 Note2 PT Compressor Delay 0~10 minutes 3 minutes Note3 CA CF Temperature Calibration Centigrade or Fahrenheit Displaying -15 ~15 /-15~15 0 /0 Note4 C Note5 TR Time Setting 0: on; 1: off 0 Note6 When TR=1, user needs to set chart 5 as bellow. Symbol Code Function Setting Range Default Setting Remarks UT Time Unit Setting D: day; H: hour M: minute D Note6 MD Cycle Mode Setting 0-999 cycle times, 00= infinite cycle 1 AT Manual or Auto Setting 0: MANUL 1: AUTO 0 Note7 STA numbers of controlling stages 1-6 stages 1 Note6 8

When setting STA=6, menus as followings: Symbol Code Function Setting Range Remarks ST1 Setting Temperature Value(-50~248 ) 25 or 77 HT1 Temperature Controlling Duration (0~999) 10 ST2 Setting Temperature Value(-50~248 ) 25 or 77 HT2 Temperature Controlling Duration (0~999) 10 ST3 Setting Temperature Value(-50~248 ) 25 or 77 HT3 Temperature Controlling Duration (0~999) 10 Note6 ST4 Setting Temperature Value(-50~248 ) 25 or 77 HT4 Temperature Controlling Duration (0~999) 10 ST5 Setting Temperature Value(-50~248 ) 25 or 77 HT5 Temperature Controlling Duration (0~999) 10 ST6 Setting Temperature Value(-50~248 ) 25 or 77 HT6 Temperature Controlling Duration (0~999) 10 5.1: Temperature setting (TS, HD, CD) When controller works normally, window displays current measuring temperature, switch working modes of cooling and heating automatically. When TR=0 When measured temperature PV TS (Temperature Set Value) + CD (Cooling Differential Value), entering into the status of cooling, cooling indicator lamp will on, cooling relay start working; when the Cooling Indicator Lamp flickering, cooling device is being in the status of compressor delay protection. When measured temperature PV TS (Temperature Set Value), cooling indicator lamp off, cooling relay stop working. When measured temperature PV TS (Temperature Set Value)-HD (Heating Differential Value), entering into the status of heating, heating indicator lamp will on, heating relay start working; when measured temperature PV TS (Temperature Set Value), heating indicator lamp off, heating relay stop working. 9

For example, set TS=25 C, CD=2 C, and HD=3 C, then when measured temperature 27 C ( TS+CD ), cooling start working, when temperature decline to 25 C(TS), stop cooling; when measured temperature 22 C (TS-HD), heating start working, when measured temperature reach to 25 C(TS), stop heating. When TR=1 TS setting value is invalid, temperature controller working based on the setting values of ST1~ ST6 and HT1~HT6. For example, when the period of time is within HT1 and while measured temperature PV ST1 (Temperature Set Value) + CD (Cooling Differential Value), cooling output working, indicator lamp of cooling will on, cooling relay start working Remark: In case the time interval between two cooling switches on is less than PT, please refer to note 3. To set periods of time operation HT1~HT6, please refer to note 6. 5.2 Alarm High/Low Limit Setting (AH, AL) When measured temperature PV AH, alarm with BI-BI-BIII sound until the temperature < AH or press any keys, then will close the buzzer. When measured temperature PV AL, alarm with BI-BI-BIII sound until the temperature >AL or press any keys, then will close the buzzer. When the buzzer alarm, output of heating or cooling will still working follow the setting. 5.3 Compressor Delay (PT) Under cooling mode, first time to power on, when measured temperature PV TS (Temperature Set Value) + CD (Cooling Differential Value), device won t start cooling immediately, but waiting for a delay time (PT). When the interval time between two refrigeration operations is longer than the delay time, device will start cooling immediately. When the interval time between two refrigeration operations is shorter than the delay time, device will start working until there is no delay time left. Delay time will be calculated right after the moment when device stop working. 5.4 Temperature Calibration (CA) When there is deviation between measured temperature and standard temperature, use temperature calibration to align the measured value and the actual value of temperature. The corrected temperature = the temperature before calibration + calibration value (positive value, 0 or negative value) 10

5.5 Display in Fahrenheit or Centigrade unit (CF) Users can select display with Fahrenheit or Centigrade temperature value according to their own habit. Default setting is display with Centigrade. For displaying with Fahrenheit, set CF to F. Attentions: when CF value changed, all the setting will be recovered to factory default setting. 5.6 Time -Temperature Parameter Setting (TR, UT, STA, ST1~ST6, HT1~HT6) TR: a parameter to check whether the function of timer works or not, TR=0, timer off; TR=1, timer on. When TR=0, there is no working of timer function and all the setting parameters after TR will not display in menu, no need to set. When TR=1, timer working, periods of time and related temperature parameters can be set according to the demand. At this time, TS (Temperature Setting Value) is invalid, temperature control according to the setting of periods of time. UT: a parameter of time unit. can be set to day, hour or minute as need. STA: a parameter of numbers of controlling stages, which can be set to max. 6 stages, each stage including a set of temperature correspond to a continuous periods of time. ST1~ST6: a parameter of temperature setting, when TR=1, the setting values of ST1~ST6 will replace TS value, as the condition parameter of temperature controlling. HT1~HT6: a parameter of continuously time, e.g. the unit of UT is hour, HT1=12, then temperature controller will control the setting value ST1 as 12 hours. For example: Control an incubator, keep the temperature 24~26 for 5 hours and 30~32 for 10 hours. Setting as followings: HD=1, CD=1, TR=1, Set UT=H, STA=2, ST1=25, HT1=5, ST2=31, HT2 =10. 5.7 Cycle and Automatic Mode (MD, AT) MD: execute times of Time-Temperature setting. 00: infinite cycle; 1~999: specific times of execution. 1 is the default setting, which means it will stop running after execute the setting values once. AT: mode of operation when power on after power off. AT=0: MANUAL, which means when power on again after power outage, temperature controller will stop working; it need to reset the parameters by entering into menu, then restart the controller and get working again. 11

AT=1: AUTO, means when power on again after power outage, the temperature controller will continue to work; at this time, the performance time of temperature controller is in accordance with natural time, and it has no concern with the power outage. For example, If set keeping 25 for four hours, keeping 30 for six hours; If there is power outagefor three hours after temperature controller keep working at 25 for two hours. At this time, the temperature controller will defaults the time 2+3=5 hours to the execution time, when it is power on again, temperature controller will execute the temperature setting at 30. 6. Error Description Sensor fault alarm: when temperature sensor being in short circuit or open loop, the controller will initiate the mode of sensor fault, and cancel all the actions. Buzzer alarm, LED displays ER. Pressing any keys can stop the alarm, and return to the normal working mode after remove the sensor fault. Over-temperature alarm: when measured temperature exceeds the measuring range (less than -50 C /-58 F or higher than 99 C/210 F), the controller will initiate over-temperature alarm mode, and cancel all the actions. Buzzer alarm, LED displays HL. Pressing any keys can stop the alarm, and return to the normal working mode when temperature returns to measuring range. 12

7. Technical Assistance and Warranty 7.1 Technical Assistance If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please write us to cs@ink-bird.com. We will reply your emails in 24 hours from Monday through Saturday. You can also visit our web site to find the answers of the common technical questions. 7.2 Warranty INKBIRD TECH. C.L. warrants this thermostat for one years from the date of purchase when operated under normal condition by the original purchaser (not transferable), against defects caused by INKBIRD s workmanship or materials. This warranty is limited to the repair or replacement, at INKBIRD s discretion, of all or part of the thermostat. The original receipt is required for warranty purposes. INKBIRD is not responsible for injury property damage or other consequential damages or damages of third parties arising directly from an actual or alleged in mater of workmanship of the product. There are no representations, warranties, or conditions, express or implied, statutory or otherwise, other than herein contained in the sale of goods act or any other statue. Contact Us Business Contact: sales@ink-bird.com Technical Support: cs@ink-bird.com Business Hours: 09:00-18:00(GMT+8) from Monday to Friday URL: 13