CONNECTA SYSTEM The fire performance tunnel lighting and power system

Similar documents
Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

The world s most trusted cable brand

The world s most trusted cable brand

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

flexible conduit solutions for rail THE POWER IN CABLE MANAGEMENT

Products Overview. Your trusted partner in process instrumentation

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

Reinventing Ceramics

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

WORLDWIDE CABLE EXPERTS

Case study: Kartell Museum

Advanced Fire Rated Ductwork Solutions

Crossrail. Clare Hebden; September 2012

INSPIRATION INNOVATION INTEGRATION. Infrastructure Solutions

Self-Regulating Point Heating Performance Requirements

GE Security. Proven. Powerful. Integrated fire and life safety solutions.

TOMORROW S SOLUTIONS TODAY

20 20 MARKET SOLUTIONS INSPIRATION INNOVATION INTEGRATION. Industrial Solutions

THE TRUE FIRE SURVIVAL CABLE

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

fire resistance testing

Infrastructure for London. Perspective

Introduction.

NOTHING BURNS BRIGHTER THAN OUR COMMITMENT TO MEETING YOUR NEEDS.

For Heavy Duty Commercial and Industrial Environments

For your commercial needs, we offer the following services:

WKE Spelsberg. The name in maintaining electrical integrity.

BSI the UK National Standards Body: The Role of Standards

WE ARE LOWE. EST. 1977

V3 Intelligent Damper Control and Monitoring System

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

Connected Metro TRANSPORTATION MADE SEAMLESS. Unveiling the Capabilities of a Connected Metro

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock

LC3000 Level Controller Installation and Maintenance Instructions

Infrastructure and the environment

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

Open to Possibilities.

Cutting edge washing systems

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

Evolution in Emergency Lighting 7 March 2018

30 mm 180 mins RWS / HCM. 24 mm 120 mins RWS / HCM. GS Kitchen Extraction & Ventilation up to 240 mins, BS 476 pt 20 & 24

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

RELIABLE SOLUTIONS FOR ELECTRIFIED RAILWAY SYSTEMS

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

FILTRONA PLC. A leading international supplier of speciality plastic, fibre, foam and packaging products FILTRONA PLC TO BE RE-BRANDED ESSENTRA PLC

SPECIALISTS IN CONNECTING TECHNOLOGIES AND ENCLOSURES.

Brochure. Security Designed, Installed by Experts

Comprehensive solutions for greater safety and security Answers for infrastructure.

PROFILE. industrial services rental trading

Geosynthetic materials Solutions for improved ground structure. Name it. We ll do it.

Working in Partnership with our Customers.

Honeywell Video Systems Product Guide

We Are Lowe. EST. 1977

Howler Go-Link Evacuation Alarm

Barnes of Ashburton MAKERS OF KITCHENS & FINE FURNITURE

North American Cable Glands

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

DESIGN LEADERS IN CONTRACT BATHROOMS

THE COMPLETE SOLUTIONS PACKAGE

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Investor Site Visit. 29 September, 2016

Spatial and Economic Master Planning. Resilient, healthy and happy places to live, work and learn

SITE SECURITY THE SMARTER WAY TO PROTECT REMOTE AND TEMPORARY SITES, 24 HOURS A DAY.

Innovative Access Solutions CEM Systems is a leading provider of access control and fully integrated security management systems that you can rely on

Fire Safety in the Channel Tunnel

Total peace of mind. Services. Services. Total peace of mind

BUILDING INDUSTRY TUNNEL RAIL TUNNEL FIRE FIGHTING WITH HIGH PRESSURE WATER MIST

ASSA Lockcases. ASSA ABLOY, the global leader in door opening solutions

Environmental Statement Review for Infrastructure

SMOKE DETECTOR TESTERS

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

170 years of seating expertise in the UK

Goedhart air coolers. Goedhart Blast freezers (LLK.p) JUST IN TIME!!

Welcome to Brugg s world

Reference report Traffic & Transportation

The New PPE Regulation (EU) 2016/425

The Quality Connection. BETAflam Fire Resistant Safety Cables

HART XL High Sensitivity Smoke Detection

Fire Protection Systems For Railway Vehicles WE ARE ENSURING FIRE SAFETY

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

Clipsal Mining Solutions. Increasing workplace safety. Adding value to mining operations.

Goedhart air coolers. Goedhart Blast freezers (PLK.s) FREEZE!!

Retail solutions by Tenos. Value engineered fire safety solutions for landmark retail developments.

- CONSTRUCTION FIRE SAFETY STANDARDS

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

Gambling with your fire security?

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

Ingersoll Rand. Refrigerated Air Dryers

CMCS Ltd. Precision monitoring for the construction industry to help manage risk

Gas ventilation monitoring and control system

34% A temperature sensor overview Cut back on system costs Upgrade to the right technology. cost reduction

DELIVERING LONDON BRIDGE STATION THE DESIGN TEAM PERSPECTIVE

LC2200 Level Controller Installation and Maintenance Instructions

Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety

Fire Resistant Cables

WIRELESS CCTV. Site Security & Surveillance.

Transcription:

CONNECTA SYSTEM The fire performance tunnel lighting and power system

Linking the Future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as a primary driver in the development of communities. With this in mind, we provide major global organisations in many industries with best-inclass cable solutions, based on state-of-the-art technology. Through two renowned commercial brands - Prysmian and Draka - based in almost 100 countries, we re constantly close to our customers, enabling them to further develop the world s energy and telecoms infrastructures, and achieve sustainable, profitable growth. In our energy business, we design, produce, distribute and install cables and systems for the transmission and distribution of power at low, medium, high and extra-high voltage. In telecoms, the Group is a leading manufacturer of all types of copper and fibre cables, systems and accessories - covering voice, video and data transmission. Drawing on almost 140 years experience and continuously investing in R&D, we apply excellence, understanding and integrity to everything we do, meeting and exceeding the precise needs of our customers across all continents, at the same time shaping the evolution of our industry.

What links global expertise to the wheels of industry? High-performing cable solutions to keep the wheels of industry turning. On every continent, in applications that range from rolling stock and vehicles for high-speed trains and urban mass transit lines, to all types of rail transport infrastructure, Prysmian Group s specialist cable solutions sit at the heart of significant international projects; supporting the work of major customers, with high-performing, durable and safe technology. As the world leader in cabling, we draw on global expertise and local presence to work in close proximity with our customers, delivering products and service platforms built on easy contact, bespoke solutions and effective supply chain, meeting their specialised requirements, to help them drive the wheels of industry and achieve sustainable growth and profitability.

CONNECTA: delivering optimum power safety for tunnel environments When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have to choose products from a company you can trust. Prysmian Group is the leading supplier of fire performance cables, zero halogen power cables and building wires in the UK. With decades of in-depth experience, our vast product range has been developed and manufactured with leading edge technology and is backed by the resources of the world leader in the energy and telecom cable systems industry. The Group s expertise delivers a wide ranging product portfolio includingcommunication, low voltage and special purpose cables. In addition we have the capability to manufacture customerspecific cable types. Part of our continuing success is down to our commitment to ongoing product development through investment in innovation. We are constantly working to improve our product range to meet your specific needs. Indeed, the development of our product range forms the cornerstone of our entire operation.

Connecta, part of our market-leading Firetuf range, is one such product. Connecta has been specifically developed to provide lighting and small power applications in tunnel environments such as sockets for transformers for portable tools. In the event of a fire, Connecta maintains the integrity of the circuit even if a local device fails, allowing escape routes further up and down the line to remain illuminated. Secondary cable connection to luminaire. (length of flylead can be specified by client)

CONNECTA: simple to install, easy to maintain. At Prysmian Group, we fully understand the importance of fire performance cables. This is why we are deeply committed to a policy of ongoing product development through investment in innovation. This is not just because we want our products and range to be consistently improved, so that they are better able to satisfy your needs, but because we understand that lives are at stake and that the performance and effectiveness of our products can help prevent loss of life. Sectional view of CONNECTA socket Installation is quick and simple

Benefits Fire performance cables for critical safety systems. At Prysmian Group we know that the safety of occupants and passengers in mass transit systems, especially road and rail tunnels, is of paramount importance. One factor that can play a key role in making these environments safer is the appropriate use of fire performance cables for critical safety systems. In the event of a tunnel fire and smoke filled environment, it is vital that the emergency lighting remains secure, to ensure that escape routes are clearly illuminated. Moreover, the correct selection and installation of these vital safety cables ensures that, in the event of an emergency, systems can continue to function and people will have time to evacuate safely, as well as helping the emergency services to operate effectively. Easy to install Another significant benefit of Connecta is the ease in which it can be installed and maintained. With project deadlines becoming tighter and tighter, Connecta offers both time and cost-saving benefits to a variety of applications. With all of the lighting or power joints manufactured in a clean factory environment, rather than in-situ on site, installation times can be reduced by up to 70%. This can assist in meeting or bringing forward project milestones or deadlines. In addition, with the jointing pre-manufactured, the need for highly skilled electrical installers can be reduced, as the system can be installed by semiskilled labour, again offering a cost-saving benefit. Optimum fire safety performance The technical resources of Prysmian Group have combined to deliver a system that offers optimum fire safety performance in tunnels. Connecta is manufactured with high quality injection moulded zero halogen, low smoke (OHLS ) components and features a moulded female socket and shrouded male plug with an optional integral fuse and coupling nut. It is available in both fire resistant OHLS and Standard OHLS designs with a primary cable of: 2.5 mm 2 to 50.0 mm 2, in 3, 4 or 5 core variations, with a wiring loom length of approximately 700 metres.* The inter socket distance and loom length required is entirely at the discretion of the client, to suit the bespoke nature of the project. This ensures the system is ideally suited to a wide variety of tunnel environments for the provision of emergency lighting and 3 phase power supplies for applications such as portable power tools working from transformers. CONNECTA: components pre-assembly View of joint retaining coupling nut CONNECTA: fully assembled *Dependant on cable size and number of sockets

Easy to maintain Each coupling system is specifically designed and manufactured to meet the clients needs with preset lengths between each moulded socket outlet unique to each installation. Secondary outputs are then taken from the primary cable via moulded plugs to prewired individual luminaires. The flyleads are generally supplied to the client s chosen luminaire manufacturer for wiring prior to sending the lighting on to site. Therefore not only is Connecta easy to install but because of its modular design, maintenance is also simple. Zero halogen, low smoke system Each Connecta is phase identified and circuit integrity meets the requirements of BS6387 Categories C, W and Z. Ingress protection meets IP 67 standards. As part of the Firetuf range of fire performance cables, Connecta also benefits from being a zero halogen, low smoke (OHLS ) system. Size 60 Size 70 Size 85 DIAMETER (mm) 60 70 85 LENGTH (mm) 148 234 174 WEIGHT (kg) 1.5 2 2.2

Project Contractor Client Application Length of Cable No. of CONNECTA's Changi Airport Extension AMEC Singapore MRT Rail Tunnel Lighting 7 km 220 North Eastern Line AMEC Singapore MRT Rail Tunnel Lighting 32 km 3400 HS1 (previously CTRL) EMCOR rail RLE (Rail Link Engineering) Rail Tunnel Lighting 97 km 4800 Dublin Port Tunnel Mercury Engineering Dublin Port Authority Rail Tunnel Lighting 14.7 km 1620 Piccadilly Line extension (Heathrow Terminal 5) Balfour Beatty Rail Tubelines (LU) Rail Tunnel Lighting 12.6 km 710 Heathrow Express extension (Heathrow Terminal 5) Balfour Beatty Rail Projects Network Rail Rail Tunnel Lighting 11.6 km 715 Airside Road Tunnels (Heathrow Terminal 5) Crown House Engineering BAA Rail Tunnel Lighting 4.3 km 1180 Waterloo and City Line Giffen Group Metronet Rail (LU) Rail Tunnel Lighting 4.5 km 610 Waterloo and City Line Giffen Group Metronet Rail (LU) Rail Tunnel Power 4.4 km 87 Brisbane Inner Northern Busway Tunnel Stowe Austrailia Queensland Transport Rail Tunnel Lighting 2.8 km 510 Holmesdale Tunnel (M25) Costain Highways Agency Rail Tunnel Lighting 15.7 km 1095 Trawsfynydd Nuclear Power Station Decommissioning Crown House Engineering Magnox Restricted Access Emergency Lighting 2 km 270 Dockland Light Railway Woolwich Arsenal Extension Colas Rail TFL Rail Tunnel Lighting 9 km 711 Bell Common Tunnel (M25) Costain Highways Agency Rail Tunnel Lighting 12.7 km 1608 Woodhead Cable Tunnel AMCO National Grid HV Cable Tunnel Lighting 5 km 264 Cuilfail Tunnel (A27) VVB East Sussex Road Tunnel Lighting 3 km 147 Hindhead Tunnel (A3) Hatfield Tunnel (A1M) Balfour Beatty Engineering Services Balfour Beatty Engineering Services Highways Agency Road Tunnel Lighting 17.8 km 1198 Highways Agency Road Tunnel Lighting 21 km 2028 Severn Tunnel (Sudbrook pumping station) Channel Tunnel- repairs to fire damaged section Network Rail Network Rail Tunnel Lighting 0.8 km 107 OpteorMaintenance Eurotunnel Tunnel Lighting 2 km 210 Blackwall Tunnel VVB Enginering Road Tunnel Lighting 7.7 km 618

CONNECTA: tried and tested. No-one does more to ensure their products deliver optimum performance than Prysmian Group. As you would expect, Connecta has been tested to the highest possible standards and meets BS 7671, I.E.E. Wiring Regulations. Our testing and commissioning programme ensures all components are tested individually then again as a complete system with luminaires energised. trusted by specifiers and contractors throughout the world. The Connecta system has been installed in: Channel Tunnel Rail Link (CTRL), London Underground, Heathrow Terminal 5 Tunnels, Dublin Port Tunnel and the Singapore Mass Transit Network (MRT) amongst many others (see table on previous page). Fire, Fire with Water and Fire with Mechanical Shock tests are all rigorously completed by our specialists and as a result Connecta is fully approved to BS 6387: 1994 and SS299 Pt1: 1998 (Singapore Standard). Furthermore the BS 6387 category C, W and Z is the internationally recognised UK test, used to determine if a cable is capable of maintaining circuit integrity under different fire conditions, as the illustrated tests show. Connecta from Prysmian Group: tried, tested and

First characteristic numeral Brief description Degree of protection from foreign particles Definition 0 Non-protected 1 Protected against solid foreign objects of 50 mm ø and greater The object probe, sphere of 5O mm ø shall not fully penetrate 2 Protected against solid foreign objects of 12.5 mm ø and greater The object probe, sphere of 12.5 mm ø shall not fully penetrate 3 Protected against solid foreign objects of 2.5 mm ø and greater The object probe, sphere of 2.5 mm ø shall not penetrate at all 4 Protected against solid foreign objects of 1.0 mm ø and greater The object probe, sphere of 1.0 mm ø shall not penetrate at all 5 Dust-protected Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or to impair safety 6 Dust-tight No ingress of dust Second characteristic numeral Brief description Degree of protection from water Definition 0 Non-protected 1 Protected against vertically falling water drops Vertically falling drops shall have no harmful effects 2 Protected against vertically falling water drops when enclosure tilted up to 15 Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angle up to 15º on either side of the vertical 3 Protected against spraying water 4 Protected against splashing water 5 Protected against water jets 6 Protected against powerful water jets Water sprayed at an angle up to 6Oº on either side of the vertical shall have no harmful effects Water splashed against the enclosure from any direction shall have no harmful effects Water projected in jets against the enclosure from any direction shall have no harmful effects Water projected in powerful jets against the enclosure from any direction shall have no harmful effects 7 Protected against the effects of temporary immersion in water Ingress of water in quantities causing harmful effects shall not be possible when the enclosure is temporarily immersed in water under standardised conditions of pressure and time 8 Protected against the effects of continuous immersion in water Ingress of water in quantities causing harmful effects shall not be possible when the enclosure is continuously immersed in water under conditions which shall be agreed between manufacturer and user but which are more severe

Linking global expertise to the wheels of industry Prysmian Group Via Chiese 6, 20126 Milan, Italy Email: marketing.energy@prysmiangroup.com www.prysmiangroup.com