VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser Unique Solutions for All-Indoor HVAC Projects
Water-Cooled Chilled Water Your Choice for Limited Space Applications The VertiCool Space Saver allows installation of an air conditioning system where minimal floor space is available and where ceiling mounted or ducted units are not practical. Standard scroll compressors provide stable cooling performance and the unit can be equipped with options that tailor it to specific job requirements. An Air-Cooled condenser can be added for heat rejection when condenser water is not available. The Air-Cooled condenser does not require additional indoor floor space and can be located internally near an outside wall or externally with an optional rain hood for roof or ground-level pad mounting. A remote Air-cooled Condensing section can also be matched with the VertiCool Space Saver. By locating the compressor(s) in the condensing unit, it will run even more quietly. Small Size: BIG Performance FEATURES 2 to 15 tons Water-Cooled or Chilled Water Heavy-gauge galvinized cabinet Sloped Stainless Steel Condensate Drain Pan Front Component Access Fits through 32 doorways Thermal/Accoustic cabinet insulation Ball bearing blower motors Inherently protected motors and compressors Copper tube/aluminum fin coils Scroll compressors Draw through air flow Single point power connection TYPICAL FLOOR SPACE SAVINGS Size Conventional Space Saver % Smaller 3 Tons 8.9 square feet 3.6 square feet 60% 5 Tons 8.9 square feet 7.3 square feet 18% 8 Tons 13.8 square feet 10.7 square feet 22% 15 Tons 19.6 square feet 15.6 square feet 20% * Savings when compared to the VertiCool Classic air conditioning unit. Other systems may vary. 2
Total Installed Cost Advantages Proudly Made in the U.S.A. Avoid Requirements that Lead to Extra Expense Expensive Equipment, Rigging or Permits Equipment can be shipped in sections Fits easily through standard doors, hallways, and into elevators Minimizes the need for crane rentals, rigging crews, and municipal permits Roofcurbs or Roof Penetration Eliminates expensive curb equipment cost Reduces installation labor Eliminates possible roof water damage Field Piping, Brazing, Evacuation or Charging Factory charged and utilizes Resealable Refrigerant Fittings Reduces installation labor Faster installation and commissioning Excessive Downtime when Replacing Old Systems Sectional shipments accelerate installation Can be installed off-hours and on weekends Shipment can be made to coincide with installation schedules Equipment Damage Due to Weather All equipment is installed indoors Avoids premature replacement costs due to weather wear and/or damage Eliminates downtime due to severe storms Possibility of Theft or Vandalism Eliminates expensive repairs and replacements due to theft and vandalism Enhances building security by eliminating interruption to service Eliminates extra cost for cages and special alarms Field Testing of Installed Product Minimizes field testing as units are functionally tested prior to shipment Reduces labor and speeds installation Assures trouble-free start-ups Outdoor Servicing of Product Outdoor/premium service expense in extreme weather completely eliminated Improves reliability Eliminates roof safety issues Architectural Damage to Building Eliminates expenses for code approvals Requires no rigging holes through building walls Minimizes any type of building alteration Compromise in Performance With Built-to- Order Design Units are built to exact requirements Avoids purchase of excess capacity from standard product offerings Extensive list of configurations and options Major Ductwork or Electrical Modifications Units ordered to closely match existing duct and utility locations Major installation, labor and time savings Exterior Condensing System Eliminates rooftop and pad installation space and cost Water-Cooled and Chilled Water configurations eliminate unsightly equipment outdoors Resealable Refrigerant Fittings Most models feature Resealable Refrigerant Fittings. Unit sections can be shipped split or split in the field without losing the factory charge resulting in no field brazing and a total installed cost advantage. 3
Proudly Made in the U.S.A. Ideal for Open Office Locations The small footprint and low profile of the VertiCool Space Saver blends nicely into any office environment and the cabinet is finished in a pleasing powder coated finish that won t easily scratch or fade. Balanced blowers, vibration-isolated compressors and acoustic insulation provide quiet operation. Flexible Cabinet Design for Free-Blow or Ducted Operation Free-Blow Operation Ducted Operation 4
Proudly Made in the U.S.A. OPTIONS Durable and attractive powder coat finish Discharge plenum with bi-directional grille Head pressure regulating valves (2- or 3-way, 150 or 350 psig) Double wall construction (perforated or solid) Hot gas bypass Drain pan overflow switch Return air grille External filter rack Upgraded blower motors for ducted applications Hot water or steam coils Water side economizer Wall mounted thermostats (Programmable or Non-Programmable) APPLICATIONS Retail Spaces Offices Schools Restaurants Historical Buildings Industrial Complexes Remote or Isolated Areas Add-on Spot Cooling Electrical Equipment Rooms Limited Access Areas 5
Water-Cooled Chilled Water Configurations Technical Data Size (Tons) No. of Circuits CFM Dimensional Data Performance Data Nominal Tons Dimensions (Inches) Water Connection A B C D Pipe Size 2 60 16 32 14 7/8 3 60 16 32 14 7/8 4 68 22 48 14 1-1/8 5 68 22 48 14 1-1/8 7 68 22 48 14 1-1/8 8 78 24 64 14 1-3/8 10 78 24 64 14 1-3/8 12 78 30 75 14 1-5/8 15 78 30 75 14 1-5/8 2 & 3 Ton 4-7 Ton 8 & 10 Ton 12 & 15 Ton Max. ESP Capacity 6 Approx. GPM Motor HP ESP (in. H20) 5 4 Total BTUH Sensible BTUH Weight (lbs.) 2 1 800 1 27,270 18,480 6 1/2 435 3 1 1200 1 38,560 25,940 9 ¾ 435 4 1 1600 1 54,370 39,280 12 ¾ 550 5 1 2000 1 46,900 48,000 15 1 600 6 1 2400 1 82,000 59,500 18 1.5 650 7 1 2800 1 90,660 66,940 24 2 700 8 2 3200 1 110,580 79,900 24 1.5 1150 10 2 4000 1 135,450 97,680 30 2 1200 12 2 4800 1 167,850 124,390 36 2 1250 15 2 6000 1 214,600 156,250 45 3 1300 (1) Refer to Technical Data for specific performance values and for chilled water performance. (2) Performance based on 80 F db / 67 F wb entering air temperature. Water entering at 85 F with a 10 rise with 3 GPM/ton. (3) Approximate weight does not include any options. (4) Max. ESP will require alternate motor/drive package and may be affected by what options are included. (5) Standard motor horsepower. Refer to Technical Data for motor upgrade options. (6) Water-Cooled performance 6
Proudly Made in the U.S.A. PFIZER The Challenge Case Study KALAMAZOO, M Maximizing floor space inside a pharmacy lab was one part of the challenge. The second part was an A/C system that could be steam cleaned in place. The Solution Our vertical SpaceSaver at 24" deep was a perfect fit. Using all stainless steel 14-4136 cabinet coil castings for this chilled water unit with hot water for reheat United CoolAir delivered in less than 9 weeks. Fitted with stainless steel return air grills and plenum the units fit into the room. GE Other Notable Clients Tufts University Huntington Data Center AT&T Vale Mine University of Penn Cathedral Visit www.unitedcoolair.com or call the factory at 717-843-4311 for more information 7
Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons Portable Cooling and Heating Units 3-30 Tons Authorized Distributor: C13-Series Horizontal 2-10 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, 12-90 Tons C-Series Horizontal 1-15 Tons Special Configuration Engineered to Order Alpha Aire 100 500 CFM OmegaAir Horizontal and Vertical 100% Outside Air 150 3000 CFM LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462 email: uca@unitedcoolair.com web: www.unitedcoolair.com Copyright by United CoolAir Corporation 2017. All rights reserved. Manufacturer reserves the right to make changes without notice. 20.3-SB (0917)