PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Similar documents
Global Journal of Engineering Science and Research Management

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Performance Study of Triple Concentric Pipe Heat Exchanger

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

2. HEAT EXCHANGERS MESA

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Compression of Fins pipe and simple Heat pipe Using CFD

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Mallikarjun 1, Anandkumar S Malipatil 2

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS


Solar air heater duct having triangular protrusions As roughness elements on absorber plate

American International Journal of Research in Science, Technology, Engineering & Mathematics

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Effect of Inclination Angle on the Air-Side Performance of Aluminum Parallel Flow Heat Exchangers Under Wet Conditions

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Mechanical Engineering Department Sheet (1)

Heat Transfer in Evacuated Tubular Solar Collectors

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

A-Type Heat Exchanger Simulation Using 2-D CFD for Airside Heat Transfer and Pressure Drop

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

A Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN

Performance Evaluation of Hybrid Solar Water Heating System Using Wire Screen Packed Solar Air Heater

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Design and Development of Water Cooled Condenser for Domestic Refrigerator

A Method of Heat Exchange Structure Optimization of the Cricoid Plastic Parts

Heat transfer and heating rate of food stuffs in commercial shop ovens

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

CFD and Thermal Analysis of FIN Tube Evaporator

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

Dae-Hyun Jin. 8/2018-Present Assistant Professor of Mechanical Engineering, Taylor University, USA

Slide 2 The type of coils we will be talking about today are round copper tube, flat fin coils.

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

Performance Study on A Window Type Air Conditioner Condenser Using Alternative Refrigerant R407C

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Numerical study of heat pipe application in heat recovery systems

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Performance investigation of Air-conditioning system using ejector as expansion device

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

a Heat Exchanger using FEA Tool

Effect of Placement of Footing on Stability of Slope

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Keywords: Micro channel condenser, refrigeration system, heat transfer rate, refrigerant Effect.

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Raman et al., International Journal of Advanced Engineering Technology E-ISSN

Experimentation of Heat Pipe Used In Nano-Fluids

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Transcription:

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE Ram Mohan Gupta 1, Dr. Shatyendra Singh 2 Mr. Simant Srivastava 3 1 Mechanical Engineering, Uttarakhand Technical University,India 2 Vipin Chandra Tripathi Kumaon Engineering College, Dwarahat, Almora Uttarakhand, India 3 Aryavart Institute of Technology and Management, Lucknow, Uttarpradesh, India ABSTRACT Modern era is the era of science and technology; here the things are changing very rapidly. Modern technology has advances the things. It has made the things easier and provided a comfort to humankind. The condenser is a heat-transfer device. It is used to remove heat from hot refrigerant vapor. Using some method of cooling, the condenser changes the vapor to a liquid. There are three basic methods of cooling the condenser s hot gases. Convection mode of heat transfer plays very important deciding factor for transferring heat from the condenser plate to surrounding air with the use of the some technology we can improve the performance of the heat transfer through the condenser plate. In this research work we have used methods such as tilting of the condenser tube with respect to horizontal and calculating the heat transfer rate and the amount of heat transfer increased by providing some angle of inclination from the horizontal. This study also tells about changing the position of the condenser can increase the heat transfer rate as in case of refrigerators i.e. from backward to upward. Keywords ansys, condenser, calculation, refrigeration 1. INTRODUCTION Condensers are very used in refrigeration and air-conditioning applications. For the same amount of heat transfer, the operation of air cooled condensers is more economic as compared with water cooled condensers [1]. Typically air-cooled condensers are of the round tube and fin type. To improve the performance of air-cooled condensers multiple techniques can be achieved such as enhancements on inner pipe surface, changing the tube geometry from round to flat shape and external fins. The flat tube design of condenser offers higher thermal performance and lower pressure drop than the finned-round tube heat exchangers [2]. Brazed aluminum heat exchanger is made from micro-channel flat tubes in parallel to each other which is called parallel flow heat exchanger (PFHE). As a result of its superior performance, some companies in heating, ventilating and air conditioning are considering the flat tube heat exchanger as a high efficiency alternative in order to save electricity when used in window and split type air conditioners which consume large amounts of electricity. The key advantage of the brazed aluminum design is smaller size and lower weight than finned-round tube condensers. The heat capacity of a parallel-flow heat exchanger (PFHE) is 150-200% larger than that of the conventional heat exchanger [3]. This high heat capacity of the PFHE can meet the requirements of high energy performance and energy efficient and also such type condensers are very compact for same amount of heat transfer and very light in design. Oval and flat cross-sectional tube for finned tube heat exchangers provides a higher heat transfer performance as compared to those formed with round tube geometry as mentioned by Chang et. al. [1]. The effect of tube profile change from round to flat shape on condensation has been investigated experimentally by Wilson et. al [4]. They used horizontal copper tubes were initially round with 9.52 mm outer diameter and 8.91 mm inner base diameter. The tubes were successfully flattened into an oblong shape with inside heights of 5.74, 4.15, 2.57, and 0.974 mm. Refrigerants R-134a and R-410A were investigated over a mass flux range from 75 to 400 kg/m 2. S, and quality range from approximately 10-80%. They summarized the result that for a given mass flow rate there is very less charge of refrigerant is used due to flattened tubes with the increase in the condensation heat transfer coefficient as a result of change in the profile of condenser tubes. As a result we can say that the heat transfer is mainly effected by the mass flow rate and tube pofile. The condensation of refrigerant in multi-port micro-channel extruded tubes has been investigated by many authors [5-7]. All of them concluded that the micro-channel flat tube enhance the inside heat transfer many times than conventional round one. So the present work is mainly concentrated on air side heat transfer coefficient enhancement as we know that heat transfer is mainly depends heat transfer coefficient. Volume 2, Issue 7, July 2013 Page 529

INDENTATIONS AND EQUATIONS h air-side heat transfer coefficient, W/m 2 K Dh hydraulic diameter, mm Vf Air face velocity, m/ s H transverse pitch of parallel tubes. mm L Width of flat tube cross section, mm Ar Aspect ratio =H/L P β pressure drop for case of inclined flat tubes by angle β, Pa. P0 pressure drop for case of parallel flat tubes with β=0 deg. β inclination angle of flat tubes with respect to horizontal, deg. Re Reynolds number, dimensionless PFHE parallel flow heat exchanger (Aluminum Brazed heat exchanger = PFHE or serpentine flow heat exchanger) η overall performance = Kh/KP Kh Enhancement factor of h = hβ/h0 KP pressure drop increase factor= Pβ/P0 ε effectiveness (0 < ε 1) NTU number of transfer units The formulas which are used for the calculation of the different parameters are as follows. Qc = m. r ( h 3 h 2 ) = m a c pa ( T co T ci ) = ε cd Q c max MATHEMATICAL MODEL Many industrial applications and research work, such as air cooling in the coil of an air conditioner, can be modeled as two-dimensional heat flow. All parameters such as tube diameter length and thickness are first modeled on CATIA software. And such model is then imported to the ansys software which can generate the pre-generated meshes and then the studies were done on the ansys software. Then modeled as bank of tubes in cross-flow, and the air outside flow is classified as turbulent and steady. The model is used to predict the Flow and temperature fields that result from convective heat transfer. Due to symmetry of the tube bank, only a portion of the geometry was modeled in CATIA software. Domain is discretized into a finite set of control volumes or cells. General transport equations for mass, momentum and energy are applied to each cell and discretized. The governing equations are solved for studying flow field. The numerical solution was conducted to investigate the influence of inclination angle (β) and aspect ratio (Ar) on the performance of air cooled condensers. The following values which applicable to window and split air conditioning systems, are used as input data for solving the studied problem: 1. Air flow is steady, two dimensional and turbulent 2. Air face velocity (Vf) =3 3. The condenser saturation temperature of refrigerant=318 K. Hence study is based on constant wall Temperature = 318 K 4. Ambient air temperature = 300 K FIGURES AND TABLES The following configuration Is basically used for the analysis. Which is first modeled as in four cases as shown in figure. and the performance is calculated using ansys software Volume 2, Issue 7, July 2013 Page 530

As shown in above figure the configuration of condenser is used for the analysis. The following physical data was taken for the analysis of the condenser including different parameters. Figure 2. Physical dimension of the condenser Condenser configurations Values Unit Diameter of the tube 5.03 mm Distances between the tubes 27.92 mm Thickness of the tube 0.71 mm Length of the tube 469.9 mm Calculation of condenser tubes with horizontal configuration. Calculation for Forward condenser Volume 2, Issue 7, July 2013 Page 531

Calculation for Backwards tubes Calculation for Convergent divergent calculation Volume 2, Issue 7, July 2013 Page 532

RESULTS AND DISCUSSION In order to study the performance of the proposed cases, the obtained results are presented relative to those of parallel flat horizontal tubes at the same operating conditions. Contour lines for temperature are shown convergent divergent. Generally, it is observed from that there is a decrease in fluid temperature towards the centre between pipes in flow direction as the flow is developing. The effect of inclination angle β on the performance of flat tube air cooled condenser is illustrated in Figure. It is also observed from the figures that with the use of convergent divergent type s tubes we can enhance the heat transfer rate. With the result obtained we can predict that if we change the place of condenser in refrigerator the performance can also improve. CONCLUSION Using the proposed convergent divergent construction of condenser enhance the heat transfer coefficient. To keep the production line that manufacturing the PFHE, the proposed placement of condenser is top position in the refrigerator. This proposed heat exchanger is the strong candidate for use in industrial applications, which is named convergentdivergent flow heat exchanger. REFERENCES [1.] Y. P. Chang, R. Tsai, J. W. Hwang : Condensing Heat Transfer Characteristics of Aluminum Flat Tubes, in Applied Thermal Engineering, 1997, Vol. 17, No. 11, pp. 1055-1065 [2.] R. L. Webb, X. M. Wu : Thermal and Hydraulic Analysis of a Brazed Aluminum Evaporator, in Applied Thermal Engineering, 2002, 22: 1369-1390 [3.] K. Chung, K. S. Lee, W. S. Kim: Optimization of the Design Factors for Thermal Performance of a Parallel Flow Heat Exchanger, in Int. J. of H&M Transfer, 2002, 45: 4773-4780 [4.] M. J. Wilson, T. A. Newell, J. C. Chato, C. A. Ferreira: Refrigerant Charge,Pressure Drop, and Condensation Heat Transfer in Flattened Tubes, in Int. J. Refrigeration, 2003, 26: 442-451 [5.] J. W. Coleman, S. Garimella: Characterization of Two Phase Flow Patterns in Small Diameter Round and Rectangular Tubes, in International Journal of Heat and Mass Transfer, 1770, 31 "0888# 1758 Volume 2, Issue 7, July 2013 Page 533

[6.] E. Bari, J. Y. Noel, G. Comini, G. Cortella : Air-cooled Condensing Systems for Home and Industrial Appliances, in Applied Thermal Engineering, 2002, 25:1446-1458 [7.] H. K. Varma, C. P Gupta: Heat Transfer during Forced Convection Condensation inside Horizontal Tube, in Int. J. Refrigeration, 1995, 18:210-214 [8.] F. F. Araid, M. A. Shalaby, M. M. Awad: Convective Heat Transfer to Gas Flow in Converging Diverging Tubes, in Mansoura University Bulletin, June 1986, V, 11, No. 1 [9.] L. H. Rabie, A. A. Sultan, Y. E. Abdel Ghaffar: Convective Heat Transfer and Pressure Drop in Periodically Convergent Divergent Variable Area Annuli, 2001, IMPEC12 [10.] M. H. Kim, S. Song, C. W. Bullard: Effect of Inlet Humidity Condition on the Air Side Performance of an Inclined Brazed Aluminium Evaporator, in I. J. of Refrigeration, 2002, 25: 611-620 [11.] G. Lazza, U. Merlo: An Experimental Investigation of Heat Transfer and Friction Losses of Interrupted and Wavy Fins for Fin-and-Tube Heat Exchangers, in Int. J. Refrigeration, 2001, 24: 209-416 [12.] S. Sanitjai, R. J. Goldstein: Forced Convection Heat Transfer from a Circular Cylinder in Cross Flow to Air and Liquids, in International Journal of Heat and Mass Transfer, 2004, 47: 4795-4805 [13.] J. S. Jabardo, G. W. Manami, M. R. Lanella: Modeling and Experimental Evaluation of an Automotive Air Conditioning System with a Variable Capacity Compressor, in Int. J. of Refrigeration, 2002, 25: 1157-1172 [14.] X. M. Wu, R. L. Webb: Thermal and Hydraulic Analysis of a Brazed Aluminum Evaporator, in Applied Thermal Engineering, 2002, 22: 1369-1390 [15.] C. Y. Yang, R. L. Webb: Condensation of R-12 in Small Hydraulic Diameter Extruded Aluminum Tubes with and without Micro-Fins, in I. J. of H&M Transfer, 2005, 39:791-800 [16.] A. Bensafi, S. Borg, D. Parent: CYRANO: a Computational Model for the Detailed Design of Plate Fin-and Tube Heat Exchangers using Pure and Mixed Refrigerants, in Int. J. Refrigeration, 1997, Vol. 20, No. 3:218-228 Proceedings Papers: AUTHOR Ram Mohan Gupta Pur. M-Tech (Thermal Engineering) Uttrakhand Technical University, Dehradun Volume 2, Issue 7, July 2013 Page 534