We Identify and S.T.O.P. Your Noise Problems

Similar documents
ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

SIGMADEK, LTD. FIRE TEST REPORT

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

Report of Surface Burning Characteristics Test on Acoustical Panel

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

FUNDERMAX GMBH FIRE TEST REPORT

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Acoustical Surfaces, Inc.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

Materials Testing by Gregory Havel

Report On Surface Burning Characteristics Determined By. PREPARED FOR: Forbo Linoleum, Inc. Hazelton, Pennsylvania TEST NUMBER T-21906

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Public Comment No. 2-NFPA [ Section No ]

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED


Public Comment No. 1-NFPA [ Section No ]

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

Indiana WX Oil Furnace Inspection Guide

Classification of Fire Performance of Wall and Ceiling Lining Materials

Fire Performance of Translucent Systems

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

GUARDIAN FIRE TESTING LABORATORIES, INC.

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

FRANCE M & F RANKING ACCORDING TO NF F

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

Southern California Gas Company Customer Programs Department

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Food Service Technology Center

Report on Public Input June 2014 NFPA 101

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Measurement of Attic Temperatures and Cooling Energy Use in Vented and Sealed Attics in Las Vegas, Nevada

Standard for tests for flammability of plastic materials for parts in devices and appliances

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio

Heat and Smoke Release of a Ceiling-Installed Speaker

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

C-01 FIRE DECKS AND BULKHEADS

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

BCTC CARPET TECHNICAL CENTRE

PRESSURE-SENSITIVE TAPE CLOSURE SYSTEMS FOR USE WITH FACTORY-MADE AIR DUCTS- STANDARDS UL 181A AND UL 181B

Smoke detection in hazardous areas:

Certificate of Compliance

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Fire Test Methods ASTM NFPA UL ISO IEC

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

ASTM E 84 Surface Burning Characteristics of "12 mm Stratificato Panel"

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

BS EN ISO : 2010

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Loudspeaker Test. Report

NFPA 285 THE BURNING QUESTION

Ceramic Fiber Heaters

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

TrueAlarm Analog Sensing

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

STR-Series Indirect-Fired Air Turnover Units

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

Transcription:

ASTM E-84 TESTING FOR MANUFACTURER, RENDERED TO: Acoustical Surfaces Inc. 123 Columbia Court North, Suite 201 Chaska, MN 55318 Noise S.T.O.P. Fabrisorb Acoustical Wall Panels TESTED: OCTOBER 3, 2002

October 30, 2002 Client: Rendered by Manufacturer for: Acoustical Surfaces Inc. 123 Columbia Court North, Suite 201 Chaska, MN 55318 Subject: Determine Surface Burning Characteristics per Twenty-Five Foot Tunnel Test Method. DISCLAIMER: This is a factual report of the results obtained from the laboratory test of sample products. The results may be applied only to the products tested and should not be construed as applicable to other similar products of the manufacturer. The report is not a recommendation or disapprobation by VTEC Laboratories Inc., of the material tested. While this report may be used for obtaining product acceptance, it may not be used in advertising. Notice: VTEC Laboratories Inc. Will not be liable for any loss or damage resulting from use of the data in this report, in excess of the invoice. This report pertains to the sample tested only. Such report shall not be interpreted to be a warranty, either expressed or implied as to the suitability or fitness of said sample for such uses or applications, as the party contracting for the report may apply such sample. 212 Manida Street Bronx, New York 10474 (718) 542-8248 Fax: (718) 542-8759 www.vteclabs.com

I. SCOPE This report contains the reference to the test method, purposes, test procedure, rounding procedures, preparation, and conditioning of specimens, descriptions of materials, test and post test observation data, and test results. II. TEST METHOD The test was conducted in accordance with, Standard Test Method for Surface Burning Characteristics of Building Materials. The 25-foot tunnel method is also described by NFPA 255 and UL 723. III. PURPOSE The purpose of the test is to determine the relative performance of the test material under standardized fire exposure. Results are given for Flame Spread and Smoke Developed Index. The values obtained from burning the test material represent a comparison with that of 1/4" inorganic reinforced cement board expressed as zero and red oak flooring expressed as 100. The flame spread results of 25-foot tunnel tests are frequently used by building code officials and regulatory agencies in the acceptance of interior finish material for various applications. The most widely accepted classification system is epitomized by the National Fire Protection Association Life Safety Code, NFPA101: Class A* 0-25 flame spread 0-450 smoke developed Class B* 26-75 flame spread 0-450 smoke developed Class C* 76-200 flame spread 0-450 smoke developed *Class A, B, and C correspond to I, II, and III, respectively, in other codes such as UBC and BOCA. This flame spread classification system is based on the premise that the higher the flame spread numbers, the greater the fire spread potential. The actual relationship between the numbers developed under this test and life safety from fire has not been adequately established.

IV. TEST PROCEDURE NOTES The furnace was preheated to a minimum of 150 F as measured by an 18 AWG thermocouple embedded in cement 1/8" below the floor surface of the chamber, 23-1/4' from the centerline of the ignition burners. The furnace was then cooled to 105 F (±5 F) as measured by a thermocouple embedded 1/8" below the floor surface of the test chamber 13' from the fire end. Prior 10-minute tests with 1/4" inorganic reinforced cement board provided the zero reference for flame spread. Periodic 10-minute tests with unfinished select grade red oak flooring provided for the 100 reference for flame spread and smoke developed as noted in Section III. A. Flame Spread The flame spread distance is observed and recorded at least every 15 seconds or every 2 feet of progression. The peak distance is noted at the time of occurrence. The flame spread distance is plotted over time. The total area under the flame spread distance-time curve is determined; flame front recessions are ignored. The flame spread is then calculated as a function of the area under the curve relative to the standard red oak curve area. The value for flame spread classification for the tested material may be compared with that of inorganic reinforced cement board and select grade red oak flooring. B. Smoke Developed The smoke developed during the test is determined by the reduction in output of a photoelectric cell. A light beam vertically oriented across the furnace outlet duct is attenuated by the smoke passing through the duct. The output of the photoelectric cell is related to the obscuration of the light source through the duct caused by the smoke. A curve is developed by plotting photoelectric cell output against time. The value of smoke developed is derived by calculating the net area under the curve for the test material and comparing this area with the net area under the curve for unfinished select grade 23/32" red oak flooring. V. FLAME SPREAD AND SMOKE DEVELOPED ROUNDING PROCEDURES Single test calculated flame spread and smoke developed values are rounded to the nearest multiple of 5 and reported as flame spread or Smoke Developed Index. Actual test values are available upon request.

VI. PREPARATION AND CONDITIONING OF TEST SAMPLES Three or four sections are generally used in the preparation of a complete test specimen that is 20.5" wide and 24' long. Materials 8' in length may be tested by using three sections 20.5" wide. A 14" length of uncoated 16 gauge steel sheet is used to make up the remainder of the test specimen; it is placed at the fire end of the test chamber. Test specimens are conditioned at a controlled temperature of 73.4 F (±5 F) and a controlled relative humidity of 50±5 percent. VII. MATERIAL TESTED 1) Supplier: 2) Burn Number: 1 3) Average Thickness (in.): 2.029 4) Average Weight (psf): 1.20 5) Average Groove Depth: N/A. 6) Product Description: S-2000 Acoustic Wall Panels 7) Color: Light Blue 8) Surface: Face side exposed 9) Sample Selection: Supplier 10) Date of Selection: September, 2002 11) Material Description by: Supplier 12) Method of Mounting: Self Supporting on Ledges 13) Sample Conditioning (days): 16

VII. MATERIAL TESTED 1) Specimen Preheat Time (min): 2:00 2) Tunnel brick Temp. (deg. F): 104 3) Ignition Time (seconds): 11 4) Time to End of Tunnel or Flamefront Distance: 3' @ 0:15 5) Time-Distance Curve Area (min./ft.): 30.3 6) Fuel and Temperature: 4.858 a) Fuel (cu. ft./min.): b) Max. Vent end Temp (deg. F) c) Time to Max. Temp. (min.): 7) After Flaming: No

TEST RESULTS Test results calculated on the basis of the areas under the curves of flame spread distance, temperature, and smoke density versus time are provided in the table below for calibration materials and for: Acoustic Wall Panels Material Description Flame Spread Smoke Developed Index Index High Density Inorganic 0 0 Red Oak Flooring 100 100 S-2000 Acoustic Wall Panels 15 40 OBSERVATIONS: Fabric consumed exposing fiber core to 14 feet. REMARKS: Melting and dripping. Fabric melting away in advance of the flame front. No burning on the tunnel floor. CONCLUSIONS: Based on one test, the Flame Spread Index, calculated according to meets Class A (Class I) - 25 or under flame spread. Neil Schultz Executive Director Amirudin Rahim Technical Director