Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Similar documents
F O C U S D O O R C L O S E R S

CERTIFICATE OF APPROVAL No CF 267. DORMA UK LIMITED Wilbury Way, Hitchin, Hertfordshire SG4 0AB Tel: Fax:

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 5075 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 646 EUROSPEC ARCHITECTURAL HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 392 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 5118 ASSA ABLOY LTD

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

CERTIFICATE OF APPROVAL No CF 388 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

CERTIFICATE OF APPROVAL No CF 689 BOSS DOOR CONTROLS

CERTIFICATE OF APPROVAL No CF 810 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

CERTIFICATE OF APPROVAL No CF 5516 ALLGOOD PLC

CERTIFICATE OF APPROVAL No CF 5038 FREEMAN & PARDOE T/A ARROW ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 5530 TALLERES DE ESCORIAZA S.A.U.

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD

CERTIFICATE OF APPROVAL No CF 117 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 5506 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 111 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS

CERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 5527 TALLERES DE ESCORIAZA S.A.U.

TECHNICA DORMA. Controlled. d Door Closing. Closerss. appended hereto:

CERTIFICATE OF APPROVAL No CF 145 GEZE LIMITED

CERTIFICATE OF APPROVAL No CF 5179 LORIENT POLYPRODUCTS LIMITED

CERTIFICATE OF APPROVAL No CF 418 PROMAT UK LTD

CERTIFICATE OF APPROVAL No CF 520 ASSA ABLOY LTD T/A ASSA ABLOY SECURITY DOORS

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Easy-action Door Closer DORMA TS83

CERTIFICATE OF APPROVAL No CF 136

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

HD72 Euro Profile Mortice Lockcase. The high performance lock that goes beyond the standard. ASSA ABLOY, the global leader in door opening solutions

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

Declaration of Conformity Declaration of Performance Notes

Technical Bulletin CE marking: from 1st July 2013

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

See product BS EN :2010

Panic & Emergency Exit Hardware

Panic and Emergency Exit Devices

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

25 th November Title:

Guidance Note No 19/1. CE Marking windows and doorsets

YOUR GUIDE TO UNDERSTANDING CPR

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Ironmongery Performance Specifications

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

Mechanically operated locks and locking plates

DECLARATION OF PERFORMANCE

EC-Certificate of Conformity Certificate CPD

ETICS and the EU Internal Market The European framework. G. Katsarakis European Commission, DG GROWTH Unit C-1: Clean technologies and products

Newstar Locks. NEWSTAR form and function for life. BS Range. London Fire Brigade Range

EC CERTIFICATE OF CONFORMITY 0432 CPD 0018

CI/SfB. Xt7. Locks and latches

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

Guideline Construction Products Regulation (EU) 305/20122

CE marking of fire-resistant doors the right way!

1. Terms defined in the Construction Products Regulation (CPR)

Declaration of Performance

DECLARATION OF PERFORMANCE

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Hospitality Vertcial Market Our Ref: ABC123

Uniclass L4181 EPIC D181. CI/ SfB (31.5) X. Orbis Classic Range

Your Key to achieving C.E Marking Compliance

High Security Locking. Product Catalogue

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Commercial Vertcial Market Our Ref: ABC123

DECLARATION OF PERFORMANCE

Public and Government Buildings

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Healthcare Vertcial Market Our Ref: ABC123

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

DECLARATION OF PERFORMANCE

Orbis Commercial Range

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Orbis Commercial Range

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

EN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire

CE marking of noise barriers and foundations

London The Building Centre 26 Store Street London WC1E 7BT T: F:

Declaration of Performance

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

Implementing the Construction Products Regulation (EU) 305/2011

Transcription:

Product ID: KL.1902 Name: Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55 Centres C=N/A Follower (mm) 8 Latch Bolt N/A Mechanism Euro- Profile Forend Finish SSS Rebates available (mm) KL.1902A - 13 KL.1902B - 25 Options Radius Forend KL.1901RC Small Lockcase KL.1903

Sashlock has a cylinder to latch function where both latch and deadbolt can be withdrawn by cylinder key or thumbturn. CONFORMITY No: KL.1902 - CE AG0088 copyright 2009 KCC Architectural

Page 1 of 1 EC CERTIFICATE OF CONFORMITY Number: 1121 - CPD AG0091 In compliance with Directive 89/106/EEC of the Council of European Communities of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products (Construction Products Directive - CPD), amended by the Directive 93/68/EEC of the Council of European Communities of 22 July 1993, it is confirmed that the following products are subject to factory production control procedures and are submitted by the manufacturer to further testing of samples taken at the factory in accordance with a prescribed test plan. The stated Notified Certification Body has performed the initial type-testing for the relevant characteristics of the product, has conducted the initial inspection of the factory and the factory production control, and is responsible for the continuous surveillance, assessment and approval of the factory production control. construction product : KL1902 Deadlock placed on the market by: Company: KCC Door Hardware and Security Solutions Limited Address: Unit 67 Western Parkway Business Park, Ballymount, Dublin 12 product classification: 3 X 5 1* 0 F 3 B C 0 0 intended use: For use on fire / smoke compartmentation doors particular conditions applicable: available with round or square forends, finishes satin, polished & polished brass This document certifies that all the provisions concerning the attestation of conformity and product performance described in Annex ZA of the product standard EN 12209:2003 were applied and that the product fulfils all the prescribed requirements. Notified Certification Body: Warrington Certification Ltd EC Reference Number: 1121 This certificate was first issued on 11/12/07 and revised on 09/01/08 and remains valid as long as the conditions laid down in the harmonised technical specification above, or the product design, or the manufacturing conditions in the factory, or the FPC itself are not modified significantly. Manager Warrington Certification Ltd. References: Mechanical test evidence: 145831 Fire test evidence: 144028 Factory references: J/011 Classification report: N/a * The referenced reports detail the precise field of application for fire/smoke door use

CERTIFICATE OF APPROVAL No CF 5234 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Unit 1 Westgate Business Park, Ballymount, Dublin 24, Ireland Tel: 00 353 1 4567 421 Have been assessed against the requirements of the Technical Schedule(s) denoted below and are approved for use subject to the conditions appended hereto: CERTIFIED PRODUCT FOCUS CONTRACT LOCKS TECHNICAL SCHEDULE TS23 The Contribution of Locks and Latches to The Performance of Fire Resisting Doorsets And TS 31 The Contribution Of Emergency Exit Devices, Operated By A Lever Handle Or Push Pad, To The Performance Of Fire Resisting Door Assemblies Signed and sealed for and on behalf of CERTIFIRE Sir Ken Knight Issued: 23 rd May 2014 Chairman - Management Council Valid to: 22 nd May 2019 Page 1 of 6

CERTIFICATE No CF 5234 FOCUS CONTRACT LOCKS 1. The locks and latches covered by this certificate are all steel cased. This approval relates to the following specific locks: KL1901 Sashlock KL1902 Dead lock KL1904 Bathroom Lock KL1905 Mortice Latch KL1907 Nightlatch KL1907AT Nightlatch KL1908 Escape Lock All models approved in 55mm back set with 20 mm and 24 mm width forend options. 2. This certification is designed to demonstrate compliance of the product or system specifically with Approved Document B (England and Wales), Section D of the Technical Standards (Scotland) and Technical Booklet E (N. Ireland). If compliance is required to other regulatory or guidance documents there may be additional considerations or conflict to be taken into account. 3. This approval relates to the use of the above locks/latches in contributing to the fire resistance performance of timber based doorsets and metallic based doorsets, as defined in BS EN 1634-1 or BS 476: Part 22: 1987. 4. This approval relates to their use with the following door assemblies:- Latched and unlatched, intumescent sealed door assemblies consisting of timber faced and edged leaves with timber, cellulosic or mineral cores in timber frames having a fire resistance up to 60 minutes (Code ITT). Latched and unlatched, door assemblies consisting of uninsulated or insulated metal door assemblies in metal frames with or without intumescent seals having a fire resistance up to 240 minutes (Code IMM/MM). 5. The locks are approved on the basis of: i) Initial type testing to EN 1634-1 and EN 12209/EN 179 (where relevant) ii) An appraisal against TS23 or TS31 (where relevant) iii) Certification of quality management system to ISO 9001: 2008. iv) Inspection and surveillance of factory production control v) On-going audit testing in accordance with TS23 or TS31 requirements Page 2 of 6 Signed Issued: 23 rd May 2014 Valid to: 22 nd May 2019

CERTIFICATE No CF 5234 FOCUS CONTRACT LOCKS 6. This approval is applicable only to the specified locks/latches used with door assemblies of proven fire resistance (as defined in BS EN 1634-1 or BS 476: Part 22: 1987) and, when fitted to timber based doorsets, using appropriate intumescent protection. The required protection for both 30 and 60 minute applications will be 2 mm thick intumescent sheet material around the lock case and a bedding of the same type and thickness of Interdens material behind the forend and strike plate. Failure to install the protection will invalidate this certificate. 7. Lock assemblies not incorporating a latching mechanism shall only be fitted to proven unlatched door assemblies. 8. The locks/latches should not be fitted higher than 1100 mm from the finished floor level of the surrounding floors. 9. Only the KL1908 Escape lock is approved for use as an emergency exit device by TS 31 ever Handle Or Push single leaf doorsets with the approved accessories detailed within the classifications section of this certificate. 10. The approval relates to on-going production. Product and/or its immediate packaging is name or name and mark, together with the CERTIFIRE certificate number and application where appropriate. 11. Timber doorsets shall be installed in accordance with BS 8214: 2008. Page 3 of 6 Signed Issued: 23 rd May 2014 Valid to: 22 nd May 2019

CERTIFICATE No CF 5234 FOCUS CONTRACT LOCKS The following table shows the acceptable doorset types and fire resistance periods: Approved Door Type Class IMM MM TT ITT ITM ITC FD20 FD30 FD60 FD90 FD120 FD240 E 20 EI 20 E 30 EI 30 E 60 EI 60 E 90 EI 90 E 120 EI 120 E 240 EI 240 See CERTIFIRE Technical Schedules for designation of doorset types i.e. ITT etc. Key: - approved - Not approved Page 4 of 6 Signed Issued: 23 rd May 2014 Valid to: 22 nd May 2019

CERTIFICATE No CF 5234 FOCUS CONTRACT LOCKS Approved lock/latch models and classifications. KL1901 Sashlock - BS EN 12209: 2003 3 X 5 1 0 F 3 B C 2 0 KL1902 Dead Lock - BS EN 12209: 2003 3 X 5 1 0 F 3 B C 0 0 KL1904 Bathroom Lock - BS EN 12209: 2003 3 X 5 1 0 F - B G 2 0 KL1905 Mortice Latch- BS EN 12209: 2003 3 X 5 1 0 F - B 0 2 0 KL1907 Nightlatch - BS EN 12209: 2003 3 X 5 1 0 F - B 0 2 0 KL1907AT Nightlatch - BS EN 12209: 2003 3 X 5 1 0 F 2 B B 2 0 Page 5 of 6 Signed Issued: 23 rd May 2014 Valid to: 22 nd May 2019

CERTIFICATE No CF 5234 FOCUS CONTRACT LOCKS Approved lock/latch models and classifications (continued). KL1908 Escape Lock - BS EN 179: 1998 + A1: 2001 3 7 6 1 1 3 3 2 A The lock is certified for use on single leaf doorsets only with the following accessories: KF5312/2001 19mm Lever Furniture Further Information Further information regarding the details contained in this certificate may be obtained from KCC Architectural (Tel: 00 353 1 4567 421). Further information regarding CERTIFIRE certification and other approved products can be obtained from CERTIFIRE (Tel: 01925 646777). Page 6 of 6 Signed Issued: 23 rd May 2014 Valid to: 22 nd May 2019

Construction Products Regulation 2011 DECLARATION OF PERFORMANCE DoP NO. KCC 010 1. Unique identification code of the product type: KL1900 Series Mortice Locks BS 55mm 2. Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4) of the CPR: KL1901 Mortice Sashlock, KL1904 Mortice Bathroom Lock, KL1905 Mortice Plain Latch, KL1902, Mortice Deadlock, KL1907 Mortice Nightlatch 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: For use on fire and smoke compartmentation doors, when fitted in accordance with the manufacturer's fitting instructions. 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5): KCC Architectural, Unit 1, Westgate Business Park, Ballymount, Dublin 12, Ireland 5. Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2): N/A 6. System or systems of assessment and verification of constancy of performance of the construction product as set out in CPR, Annex V: System 1 7. In case of the declaration of performance concerning a construction product covered by a harmonised standard. EN12209: 2003 incorporating Corrigendum No 1 Notified product certification body No. 1121 performed the determination of the product type on the basis of type testing (including sampling); initial inspection of the manufacturing plant and of the factory production control and continuous surveillance; assessment and evaluation of factory production control; and issued the certificate of constancy of performance of the product. 8. European Technical Assessment: N/A 1

9. Declared Performance Essential characteristic Performance Self closing 5.4.2 Closing force Grade 5, Up to 200 kg door mass, 25 N max. closing force 5.1.2 Re latching force of Greater than 2.5 N latch bolt Essential characteristic Performance Self closing 5.3.1 Durability of latch Grade X, 200,000 test cycles, 120 N load on latch action bolt Ability to maintain the door Grade 1 in the closed position and not contribute to the spread of fire Dangerous Substances Annex ZA3 The materials in the product(s) do not contain or release any dangerous substances in excess of the maximum levels specified in existing European material standards or any national regulations Harmonised technical specification EN 12209: 2003 incorporating Corrigendum No 1 Harmonised technical specification EN 12209: 2003 incorporating Corrigendum No 1 10. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4. Signed for and on behalf of the manufacturer by: Chris Kilpatrick Managing Director Date of issue: 1 st July 2013 KCC Architectural, Unit 1, Westgate Business Park, Ballymount, Dublin 12 Ireland 2