Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE

Similar documents
Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

Instructions. Consumer Info-Line

Forehead Infrared Thermometer

Health & Safety Kit. Digital Bath and Room Thermometer FlexiSafe Fever Alarm Thermometer Nasal Decongester

No Touch Thermometer

Kinsa Smart Ear ThermometerTM Instructions For Use

Forehead Thermometer Instruction Manual

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

CLETEF-786. Infrared Thermometer Instruction Manual

The EZEtemp Single-Use Clinical Thermometer. A Few Simple Instructions

By cmlam at 2:33 pm, Dec 12, 2017

NON-TOUCH THERMOMETER User Manual

User Manual. Non-contact Infrared Thermometer.

DIGITAL BODY WEIGHT SCALES PS 4110

AlcoBlow. User Handbook

Connex Integrated Wall System 2.2 Software Version

CareTemp Touch Free Thermometer. Directions for use

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

100 Ft. LASER DISTANCE METER

Indoor/Outdoor Temperature Alert

BIG DISPLAY ALARM CLOCK USER MANUAL

(Place Logo from Lab here)

CLEO VERSATILITY IN VITAL SIGNS

USER MANUAL. heart rate monitor. measure your heart rate for a better, healthier you! JoinWeGo.com

I/R Thermometer Gun 12:1

GHC Thermee Non-Contact Forehead Thermometer Instruction manual V2.5

OMNI Express VS VERSATILITY IN VITAL SIGNS

Dual-Mode Infrared Thermometer Instruction Manual

HIn3550 Magnetic Field Monitor User's Manual

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

FEATURES AND SPECIFICATIONS

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Forehead Thermometer Instruction manual

INFRARED PANEL HEATER

AS 500. Instructions for Use. Version 1.0. December

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

Mats Only. Butane Cartridges Not Included. 12 Mosquito Repellent Mats Lasting 4-Hours Each TOTAL MOSQUITO 48PROTECTION

Thermometer model 02059

Visit us at

IMpORTANT SAFETy INSTRUcTIONS

CONTENTS. III. OPERATING INSTRUCTIONS... pg 7 LOADING DISPOSABLE SET (Figure 4)... pg 9. IV. INDICATORS AND ALARMS... pg 10

Material Safety Data Sheet

POLAR BREEZE Statim Technologies, LLC IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS

KEEP OUT OF REACH OF CHILDREN See side panel and insert for CAUTION additonal First Aid and Precautions MR450 ZONECHECK INDICATOR

Infrared Thermometer

Whole House Filter Model: WH-LD

Dry Bath Heating Systems

Owner s Manual. 5 year parts limited warranty. See inside for details

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

EXTERNAL CARDIAC AMBULATORY TELEMETRY

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

TRANQUILITY ADVANCED HEATING SYSTEM

WARNING Important Safety Information

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

User's Guide. Pinless Moisture Meter. Model MO257

BEVERAGE COOLER. 3.2 Cubic Feet. Before using your Beverage Cooler, please read this manual.

Digital Heat Block User Manual

Cavitator Ultrasonic Cleaner Instruction Manual

Thermometer with Probe model 00891A

Super Stubble. Model 7898U

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Read this Safety Guide first.

Operator s Manual. IP-100 Immersion Probe Cooler

WARNING Important Safety Information

62 MAX/62 MAX + Infrared Thermometer

SUPER BEARD. Model 7897U

WARNING Important Safety Information

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

MicrOTDR. Optical Fault Locator. User Manual

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

User's Guide. Pinless Moisture Meter. Model MO257

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

BODY HAIR TRIMMER MT 5531

Integra Ultrasonic Tooth Scaler

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Transcend Heated Humidifier User Manual

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Model: 1001T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

HI COD REACTOR and Test Tube Heater 2008 Series

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

3R, 3G 5R, 5G Point Laser Levels

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

Operation Guide DQR-200

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Dual Laser InfraRed (IR) Thermometer

User Manual. 40 Tower Fan MODEL: WFTR40W

USER GUIDE Heat Index Psychrometer

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

Transcription:

Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE 1

Intended Use: A digital thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with an electric signal amplification, conditioning, and display unit. Safety Information: WARNING: High, prolonged fever requires medical attention especially for young children. Please contact your physician. WARNING: Do not allow children to take their temperatures unattended. WARNING: Read the enclosed instructions carefully to ensure accurate temperature readings. Temperature readings are affected by many factors including exercise, drinking hot or cold beverages prior to taking a reading as well as technique. WARNING: Do not allow children to walk or run during temperature taking. The rigid probe could present a hazard. Oral, underarm, and rectal temperatures vary by approximately 1 F (0.5 C). WARNING: Keep battery out of children s reach. Swallowing battery could be harmful. Battery should not be recharged or placed into extreme heat as it may explode. WARNING: This product may contain a chemical known to the state of California to cause cancer, birth defects, or other reproductive harm. CAUTION: Do not take an axillary temperature through patient s clothing. Direct probe cover to skin contact is required. CAUTION: Biting the probe tip while taking a temperature may result in damage to the probe. CAUTION: Do not autoclave. Please note the cleaning procedures described in this manual. CAUTION: Do not store the unit under direct sunlight, at a high temperature, or in high humidity or dust. Performance may be degraded. CAUTION: Do not use this device close to strong electromagnetic fields such as mobile telephones or radio installations. Keep a distance from such devices when using this unit. CAUTION: IP22: Protected against solid foreign objects of 12.5 mm diameter and greater. Protected against vertically falling water drops when the device is tilted up to 15. CAUTION: Do not use the device if you it is damaged or if anything appears unusual. 2

How to take temperature: 1. Place a probe cover carefully over the tip (Figure 1). Select oral, underarm, or rectal as your measurement site based on the individual requiring a temperature measurement. Figure 1 2.Push the Multi-Function button located at the end of the thermometer. The display F will read: 188.8. This is a function check indicating the unit is working properly. The M last measured temperature will be displayed for approximately 2-seconds. Next the thermometer will read L F.(or L C). 3.The F or C symbol will flash when the unit is ready to measure temperature. Please note that the indicates a low battery. Do not expect an accurate temperature reading if this low battery indicator is present. An ERR message in the window indicates your unit is not functioning properly. 4.Depending on the measurement site, the unit will complete measurement in 40 (rectal), 60 (oral), or approximately 90 (axillary) seconds. When the F or C symbol stops flashing and the display reads a consistant temperature, the peak temperature has been reached. 5. Read and record the temperature and time for reference. The reading will automatically be stored in the memory. 6.Push the Multi-Function button to turn the unit off. This will prolong the battery life. If you do not turn the unit off, it will shut off automatically in approximately 8 40 +/-1 minutes. Oral use: (for children 4 years and older) 1.Do not drink hot or cold fluids, exercise or perform other activities that will raise or lower temperature readings when compared to your normal, average temperature. The mouth should remain closed up to 5 minutes before attempting a reading. 2.Place the probe tip well under the tongue as indicated (Figure 2). Figure 2 3

3.Instruct children not to bite down on the probe. 4.The peak temperature should be reached in approximately 60 seconds, and a beep will sound. Opening the mouth or improper placement of the probe tip could result in a longer time for a reading. Rectal use: 1.Commonly used for babies, young children or when it is difficult to take an oral or underarm temperature. 2.After placing the probe cover on the thermometer, lubricate with a water-soluble jelly or petroleum jelly. 3.Gently insert the probe tip no more than 1/2 inch or 1.3 cm into the rectum. Do not force the tip into the rectum if resistance is encountered. 4.Dispose of the used probe cover and wash the thermometer as recommended. 5.The peak temperature should be reached in approximately 40 seconds, and a beep will sound. Underarm (Axillary) use: 1.Wipe underarm with a dry towel. 2.Place probe tip in armpit and bring arm down against the body. 3.The probe should be pointing upward in the same direction as your body if possible. 4.The time required for an accurate underarm temperature may be 90 seconds or longer depending on placement of the probe and closure of the arm against the body. Operation of the F - C feature (How to change the measuring scale) From the OFF position, hold down the Multi-Function button for 5-sec. The thermometer will automatically change from F - C or C - F. Release the button. You may toggle between C + F. After 3-sec. in one scale the C or F will flash, indicating ready to measure. 4

Standards: Complies with EN 12470-3, ASTM E 1112-00, IEC 60601-1, IEC 60601-1- 2 Electromagnetic compatibility: device fulfills the stipulations of standard IEC 60601-1-2 The manufacturer recommends a calibration check every 2 years. How to care for this product: Use of probe covers is recommended to help avoid spreading germs, and to keep the thermometer clean. The thermometer should be cleaned after use even when probe covers are used. Clean the thermometer tip and probe only using isopropyl alcohol or soap and water. Store the unit in the protective case while not in use. Do not store or keep in direct sunlight, or in high temperatures. Keep battery away from children. Do not open the thermometer. Do not drop the thermometer, as this may ruin the unit. The manufacturer recommends verifying the accuracy by an authorized laboratory Parts and Assembly Probe Tip Display Window Multi-Function Button 5

Specifications Size Weight Display: Battery: Battery Life: Measurement Time: Measurement Range: Accuracy: 5 L x 3/4 W x 3/8 H (12.7cm L x 1.905cm W x.9525cm H) 0.49 oz (14 grams) LCD, Liquid Crystal Display 1.5v(LR41) Estimated 1,500 uses / 5 years Oral 60 Seconds / Rectal 40 Seconds / Axillary 90 Seconds 90.0 F to 109.9 F / 32.0 C to 43.9 C 0.2 F / 0.1 C between 96.0 F to 107.0 F / 34.0 C to 42.0 C at a room temperature of 64.4 F to 82.4 F / 18 C to 28 C +/-0.4 F/0.2 C between 90.0 F to 96.0 F/32.0 C to 34 C and 107.0 F to 109.9 F/42.0 C to 43.9 C Measurement Mode: Auto Turn Off: Memory Feature: Operating Environment: Real measurement with peak-hold method In approximately 8 40 +/-1 minutes Stores last temperature taken. 10 C to 40 C, humidity: 15 % to 95 % (noncondensing) Storage Environment Temp: -25 C to +60 C, humidity: 15 % to 95 % (noncondensing) Standard: IEC60601-1-11 WARRANTY: This Thermometer is guaranteed for a period of 24 months from date of purchase. This warranty does not cover batteries, or damage resulting from improper handling or use. Specific legal rights stipulated in your state may guide this warranty. If you have a legitimate claim under this warranty, send item(s) postage paid to Service Center, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY 11788. Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem., your return address and $2.00 to cover shipping and handling. Visit www.adctoday.com to view this instruction booklet in other languages. 6

EC REP Onbo Electronic (Shenzhen) Co., Ltd. No. 497, Ta Laneg Nan Road, Ta Laneg Street, Baoan District, Shenzhen, China Microlife AG, Espenstrasse 139, 9443 Widnau, Switzerland Distributed by: ADC 55 Commerce Drive, Hauppauge, NY 11788 Inspected in the USA Made in China tel: 631-273-9600 toll free: 1-800-232-2670 fax: 631-273-9659 www.adctoday.com email: info@adctoday.com Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use. Type BF applied part Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste. IB p/n 93-412-00 rev 4 0044 Printed in China 7