Jan05 Rev A EC

Similar documents
Two Circuit Heavy Duty Burner Connector

Jun08 Rev C

Jun08 Rev A

Mar11 Rev C

Mar11 Rev B

Jul07 Rev C

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

USB 3.0 Plug & Receptacle

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

HMN-D2 Insert Series

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

FEB. 17 Rev. A1

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Qualification Test Report LC Duplex Adapter For LC Cutouts

Cat 6 Shielded Patch cords

/Oct/2014 Rev E

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Cat 6 Unshielded Patch cords

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Apr06 Rev A

/Oct/2014 Rev B

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Jan07 Rev B

Product Specification CAT 6 UNSHIELDED PATCH CORDS

APR 17 Rev A

/Mar/2014 Rev A

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

Application Specification MAG-MATE* Poke-In Tab Terminals

SolderSleeve Insulated Electrical Termination Devices

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

JUL 18 Rev A1

Introducing Hermaphroditic Blade and Receptacle Connector

Introducing SlimSeal SSL Connector

Qualification Test Report 1/Jul/2005 Rev. A

Inverted Through Board Surface

Revisions to this application specification include: Updated document to corporate requirements Changed product types in table in Figure 6

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

SECTION ISOLATED POWER SYSTEMS

Universal Retention Modules 02 MAR 10 Rev A

Introducing Inverted SMT Thru Board Connector

Thermostat Catalog 2004

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

QUADRAX D-SUB CONNECTORS

Thermostat Catalog 2004

This instruction sheet covers the Hand Crimping Tools listed in Figure 1, which are used to crimp the terminal types listed in Figure 2.

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

TETRA-CRIMP* Hand Crimping Tool

CONTENTS AUTOMATIC TRANSFER SWITCHES

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents

Heavy Head Hand Tools , , , and AUG 15 Rev K

Introducing Low Voltage DC Grid Interconnects

Vibration tests on a TNAML Luminaire

Reasons for reissue are provided in Section 6, REVISION SUMMARY.

EIA STANDARD TP-38B EIA B. Cable Pull-Out Test Procedure for Electrical Connectors. EIA/ECA B (Revision of EIA A)

SECTION AUTOMATIC TRANSFER SWITCHES

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Single- Action Double- Action

UFGS (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Hydraulic Crimping Head, PN

SECTION GENERATOR PARALLELING CONTROLS

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

Heavy Head Hand Crimping Tools (HHHT) [ ]

Read these instructions thoroughly before crimping any terminals.

SOLARLOK Interconnection System Installation Manual

FEB 16 Rev T

SECTION AUTOMATIC TRANSFER SWITCHES

Hydraulic Crimping Head, PN 69069

7800 SERIES 22-Terminal Universal Subbase

RF one-step BNC/TNC connectors for coaxial cable termination

Introduction. Technical Features

Table of Contents. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction 3.0 TEST PROGRAM 2

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SECTION AIR COILS

7800 SERIES RM7888A Relay Module

Hydraulic Crimping Heads and

Instruction Sheet Crimping Head Cross Reference for Pneumatic Tools. 626 Pneumatic Tooling Systems. Pneumatic Tool 69015

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

INTERNATIONAL STANDARD

Product Specification Qualification Test Report

City of Duluth Festival Center 04/25

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

50A Integrated Furnace Control

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

Z-PACK TinMan 85 ohm Connector Overview

SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

Hydraulic Crimping Head, PN

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

Installation Instructions Wall Ovens

DETAIL SPECIFICATION. EXTINGUISHER, FIRE, HALOCARBON (HFC-236fa), PORTABLE, WITH MOUNTING BRACKET, FOR AVIATION USE

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Transcription:

Product Specification Two Circuit Heavy Duty Burner Connector 108-1056 12Jan05 Rev A EC 0990-0059-05 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics two circuit heavy duty burner connector. This connector system provides a reliable means of connect/disconnect for range surface burner units. 1.2. Qualification When tests are performed on the subject product line, procedures specified in Figure 1 shall be used. All inspections shall be performed using the applicable inspection plan and product drawing. 1.3. Qualification Test Results Successful qualification testing on the subject product line was completed on 31Jan92. The Qualification Test Report number for this testing is 501-165. This documentation is on file at and available from Engineering Practices and Standards (EPS). 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the latest edition of the document applies. In the event of conflict between the requirements of this specification and the product drawing, the product drawing shall take precedence. In the event of conflict between the requirements of this specification and the referenced documents, this specification shall take precedence. 2.1. Tyco Electronics Documents! 109-1: General Requirements for Test Specifications! 109 Series: Test Specifications as indicated in Figure 1! 114-1028: Application Specification! 501-165: Qualification Test Report 3. REQUIREMENTS 3.1. Design and Construction Product shall be of the design, construction and physical dimensions specified on the applicable product drawing. 3.2. Material! Contact: Copper alloy, high temperature! Housing: Phenolic, black, heat resistant grade, UL 94V-0 Silicate ceramic, natural 2005 Tyco Electronics Corporation Harrisburg, PA All International Rights Reserved. * Trademark Indicates change For latest revision call AMP FAX*/Product Info number 1-800-522-6752. For Regional Customer Service, visit our website at www.tycoelectronics.com 1 of 7 LOC B

3.3. Ratings! Voltage: 300 volts AC! Current: See Figure 2 for applicable current carrying capability! Temperature: -40 to 200/C 3.4. Performance and Test Description Product is designed to meet the electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests are performed at ambient environmental conditions per Test Specification 109-1. 3.5. Test Requirements and Procedures Summary Test Description Requirement Procedure Examination of product. Meets requirements of product drawing and Application Visual, dimensional and functional per applicable quality inspection Specification 114-1028. plan. ELECTRICAL Termination resistance, dry circuit. )R 5 milliohms maximum between AMP Spec 109-6-1. initial and final readings. Subject mated contacts assembled in housing to 50 millivolts open circuit at 100 milliamperes. See Figure 3. Dielectric withstanding voltage. No breakdown or flashover. AMP Spec 109-29-1. 1600 volts AC. Test between adjacent contacts of unmated connector assemblies. Insulation resistance. 5000 megohms minimum. AMP Spec 109-28-4. Test between adjacent contacts of unmated connector assemblies. Current cycling. See Note. AMP Spec 109-51, Condition B, Test Method 2. Subject mated contacts to 3500 cycles at 125% of rated current for 15 minutes ON and 15 minutes OFF. Temperature rise vs current. Vibration, random. 30/C maximum temperature rise at specified current. MECHANICAL Discontinuities shall not be measured. See Note. Figure 1 (cont) AMP Spec 109-45-1. Measure temperature rise vs current. See Figures 4 and 3. AMP Spec 109-21-7, Test level B. Subject mated connectors to 2.22 G s rms for 2 hours in each of 3 mutually perpendicular planes. See Figure 5. Rev A 2 of 7

Physical shock. Test Description Requirement Procedure Discontinuities shall not be measured. See Note. AMP Spec 109-26-1. Subject mated connectors to 50 G's half-sine shock pulses of 1 millisecond duration. 3 shocks in each direction applied along 3 mutually perpendicular planes, 18 total shocks. See Figure 5. Mating force. 12 pounds maximum. AMP Spec 109-42, Condition A. Measure force necessary to mate connector with burner unit using free floating fixtures at rate of.25 inch per minute. Unmating force. 1.5 pounds minimum. AMP Spec 109-42, Condition A. Measure force necessary to unmate connector from burner unit at rate of.25 inch per minute. Contact insertion force. 6 pounds maximum per contact. AMP Spec 109-41. Measure force necessary to insert contact into housing. Contact retention. Contacts shall not dislodge. AMP Spec 109-30. Apply axial load of 25 pounds to contact by pulling on wire. Crimp tensile. Wire Size Crimp Tensile (AWG) (Lbs min) 18 30 16 45 14 60 AMP Spec 109-16. Determine crimp tensile at a rate of 1 inch per minute. Durability. See Note. AMP Spec 109-27, except use test tab. Mate and unmate connector assemblies for 3500 cycles at a maximum rate of 600 cycles per hour. See Figure 6. ENVIRONMENTAL Thermal shock. See Note. AMP Spec 109-22. Subject mated connectors to 25 cycles between -40 and 200/C. Humidity-temperature cycling. See Note. AMP Spec 109-23-3, Condition B. Subject mated connectors to 10 humidity-temperature cycles between 25 and 65/C at 95% RH. Temperature life. See Note. AMP Spec 109-43. Subject mated connectors to temperature life at 200/C for 500 hours. NOTE Shall meet visual requirements, show no physical damage and shall meet the requirements of additional tests as specified in the Test Sequence in Figure 2. Figure 1 (end) Rev A 3 of 7

3.6. Product Qualification and Requalification Test Sequence Test Group (a) Test or Examination 1 2 3 4 Test Sequence (b) Examination of product 1 1,9 1,8 1,5 Termination resistance, dry circuit 4,8 2,7 Dielectric withstanding voltage 3,7 Insulation resistance 2,6 Current cycling 3 Temperature rise vs current 3,8 2,4 Vibration, random 6 6(c) Physical shock 7 Mating force 3 Unmating force 9 Contact insertion force 2 Contact retention 10 Crimp tensile 11 Durability 5 Thermal shock 4 Humidity-temperature cycling 4(d) 5 Temperature life 5 NOTE (a) See paragraph 4.1.A. (b) Numbers indicate sequence in which tests are performed. (c) Discontinuities shall not be measured. Energize at 18/C level for 100% loading as determined in Test Specification 109-151. (d) Precondition samples with 10 cycles durability. Figure 2 4. QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Sample Selection Connector housings and contacts shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Test group 1 shall consist of 5 assemblies loaded with 1 contact on 18 AWG wire and 1 contact on 16 AWG wire. Test group 2 shall consist of 5 assemblies (10 contacts) on 18 AWG wire and 5 assemblies (10 contacts) on 14 AWG wire. Test group 3 shall consist of 5 assemblies (10 contacts) on 16 AWG wire. Test group 4 shall consist of 5 assemblies (10 contacts) on each wire size. B. Test Sequence Qualification inspection shall be verified by testing samples as specified in Figure 2. Rev A 4 of 7

4.2. Requalification Testing If changes significantly affecting form, fit or function are made to the product or manufacturing process, product assurance shall coordinate requalification testing, consisting of all or part of the original testing sequence as determined by development/product, quality and reliability engineering. 4.3. Acceptance Acceptance is based on verification that product meets the requirements of Figure 1. Failures attributed to equipment, test setup or operator deficiencies shall not disqualify the product. When product failure occurs, corrective action shall be taken and samples resubmitted for qualification. Testing to confirm corrective action is required before resubmittal. 4.4. Quality Conformance Inspection The applicable quality inspection plan will specify the sampling acceptable quality level to be used. Dimensional and functional requirements shall be in accordance with the applicable product drawing and this specification. 4.5. Certification This product has been recognized under the Component Recognition Program of Underwriters' Laboratories Inc., Electrical File Number E-70200 and Certified by the Canadian Standards Association, Certification Number LR-7189. Figure 3 Temperature And Resistance Measurement Points Rev A 5 of 7

Figure 4 Current Carrying Capability Figure 5 Mounting & Clamping Location For Vibration & Physical Shock Rev A 6 of 7

NOTE (a) (b) Part Number A Dimension 103836-3.0950 ±.0005 All dimensions are in inches. Material shall be steel AISI type 01 with a Rockwell hardness of C60-62 and a finish of 10 microinches. Figure 6 Durability Test Gage Rev A 7 of 7