Air Resource Specialists, Inc.

Similar documents
Optec NGN-2 LED Ambient Integrating Nephelometer

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES AUTHORIZATIONS TITLE NAME SIGNATURE

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES NEPHELOMETER MAINTENANCE (IMPROVE PROTOCOL) AUTHORIZATIONS TITLE NAME SIGNATURE

OWNERS MANUAL OPERATION GUIDE

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTICAL DATA REDUCTION AND VALIDATION (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Three categories of instruments

MGC Dock User s Manual

MGC Dock User s Manual

Knight Trak II Instruction Manual

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Specifications Wavelength Range: 190 nm to 800 nm continuous

Mark 25 Ultrapure Water Conductivity Analyzer

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Power Flame Incorporated

USER GUIDE. RLH Auxiliary Fan Kit. Description. The leader in rugged fiber optic technology. ENCLOSURE TEMPERATURE CONTROL. RLH Industries, Inc.

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

HOBO U30 Remote Monitoring Systems

Spectron LSN (Life Safety Network) Suggested Specifications

Certificate: _01 / 22 March 2013

LaserFOCUS VLF-250 Engineering Specification

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

GAS MONITOR Model Model

Certificate: / 29 April 2014

Model OEM-2 INSTRUCTIONS FOR USE

NT DUAL CHANNEL DISPLAY. User Guide

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Pump-Up Controller MODEL 4062

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Specification for On-Line UPS Battery Monitoring and Data Management System

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

SECTION AUTOMATIC TRANSFER SWITCHES

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

CO 2 Laser. High Reliability and Performance

VSA Series Air Dryer. User s Guide

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

ACTIVE INFRARED BARRIER

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Pump-Down Controller MODEL 4052

HART XL High Sensitivity Smoke Detection

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Nardalert S3 TM Non-Ionizing Radiation Monitor

Added password for IP setup page : Password must be in IP format!

Series 5000 Hydrazine Analyzer Model 60002

Warranty Registration

HART XL High Sensitivity Smoke Detection

Commercial and Light Industrial Fire Alarm Control Panel

wireless. web-based. worthy of the name RACO.

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

TCR. Features: TISSUE CULTURE

Global Water Instrumentation, Inc.

AS950 PORTABLE SAMPLERS

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

TCC-34. Features: TISSUE CULTURE

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. DIGITAL CHILLING INCUBATOR MODELS MD5-600, MD5-602, AND MD5-604

METOS Compact SMS. The smooth change of a product. Gottfried Pessl

900MAX PORTABLE SAMPLERS

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

ROAM DCM Control Specification Guideline Division 16520

TPR. Features: TALL PLANT

JENCO ELECTRONICS, LTD.

Using the Model 1500 Portable Chilled Mirror Hygrometer

Advance Optima Module Magnos 17

Twin Photobeam Detectors Manual

Mercury Vapor Monitor VM-3000

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

A New Standard of Excellence

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Druck DPI 705/DPI 705 IS Series

SPC-56 SHORT PLANT.

Enclosed Scroll Air Compressor System SES 3-5 HP

Product Specifications

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

PUV, PIR and PFO Series BROCHURE

Operation Manual. Rev. E GEM-MRI. Oxygen Sampling System.

Model Q45P/R. ph/orp Monitor...

Using the DewTrak II Dew Point/ Humidity Transmitter

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

VM-3000 Mercury Vapor Monitor

Type 300 Series Electrode Stabilization Ovens

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

CERTIFICATE of Product Conformity (QAL1)

Transcription:

Air Resource Specialists, Inc. Optec NGN-2A Nephelometer Support Systems Price List July 2006 FULLY INTEGRATED OPTEC NGN-2A MONITORING AND DATA LOGGING SUPPORT SYSTEMS (costs do not include the Optec NGN-2A nephelometer) N21000 AC line-powered nephelometer support system, including: $12,140 10 support tower (N22000) Precipitation/solar radiation shield (N22010) Serial data logging and control subsystem (N23000) Manual span gas calibration system (N25030) AT/RH monitoring system (N25000) COMPONENT COSTS Mounting Systems N22000 10 support tower $700 Mounting base plate and tower assembly hardware Guy kits N22004 20 support tower $825 Mounting base plate and tower assembly hardware Guy kits N22010 Precipitation/solar radiation shield $995 N22020 Wall mounting bracket $225 Serial Data Logging and Control Subsystems N23000 Fully integrated logging and control system capable of supporting $7,600 AC or DC (solar-powered operation). Weatherproof, lockable enclosure containing: Campbell Scientific micrologger and two (2) storage modules Telephone modem Power supply (AC systems only) Power line surge protection Signal interface box with power indicator lights Thermostatically-controlled DC cooling fan External connectors to provide nephelometer power and data link, AT/RH sensor power and data link, input power, auxiliary serial and analog data output, remote communications, and auxiliary power Connector array configured to accommodate additional sensors Remote Communications N24010 Satellite data collection system with antenna Call for (several options available) current price N24020 Other options, including cellular phones and radio links available Call for current price

Support Sensors and Systems N25000 AT/RH monitoring system $1,995 AT/RH Sensor Force-aspirated radiation shield with mounting hardware N25020 Automatic span gas calibration system $4,100 30 lbs. SUVA 134a calibration gas cylinder (rated to operating temperature of 50ÿ C) (Call for heavy-duty refillable cylinder options for extreme temperature applications) Valves and pressure regulator; provides uniform gas flow at 10 psi (approx. 1.5 l/m) Gas delivery hoses Aluminum system enclosure; vented and lockable with mounting hardware System is controlled by the data logging control subsystem (N23000) N25030 Manual span gas calibration system $850 30 lbs. SUVA 134a calibration gas cylinder (to be stored in a nearby building) Pressure regulator with hoses Remote Power Systems N26000 Fully integrated solar-power system (latitude and exposure dependent) Call for (capable of up to 10 days (no sun) reserve), including: current price Solar panels (approx. $6,000) Panel mounting hardware Interconnect cabling Charge controller and enclosure Deep-cycle batteries Ventilated battery enclosure WARRANTY AND RETURN POLICY Air Resource Specialists, Inc. warranties all products to be free from defects in workmanship and materials for one (1) year from date of delivery. We will repair or replace, at our option, any defective item during this period, providing there is no evidence of misuse. Warranty items must be returned to us freight prepaid. For additional information, contact: Air Resource Specialists, Inc. 1901 Sharp Point Drive, Suite E Fort Collins, Colorado 80525 Telephone: 970-484-7941 Fax: 970-484-3423 E-mail: info@air-resource.com Web site: www.air-resource.com All prices and specifications are subject to change without notice.

NEPHELOMETER PRICE LIST Effective Date: September 29, 2006 INSTRUMENTS 88100 Model NGN-2A Open-Air Integrating Nephelometer. $10,950.00 Integrating polar nephelometer designed for ambient visibility extinction measurements. This model uses a unique integrating open-air design that allows accurate measurement of the scattering extinction coefficient of ambient air. The NGN-2A includes a light projector with bulb, clean air filter, all CMOS electronics for full instrument control and unattended operation, rain sensor, and digital and analog outputs. Requires external power supply capable of providing 13.8 VDC at 4.5 amps (connector parts are included), external data logging device, and span gas for calibration. Instrument is typically installed by suspending from above using the four built-in mounting bolts. Overhead protection is highly recommended. Easy-to-use data logging software is included (external PC with serial port is required for data logging software.) 88125 Model NGN-3A PM 2.5 Size-Cut Nephelometer. $10,950.00 Integrating polar nephelometer designed for accurate measurement of the scattering coefficient of dry air. This instrument uses a spiral sampler and heated inlet to separate out particles larger than 2.5 microns to satisfy the PM 2.5 standard. The NGN-3A instrument includes light projector with bulb, clean air filter, relative humidity sensor, all CMOS electronics for full instrument control and unattended operation. Digital and analog outputs are available as well as an integrated numeric output display. Four-button switch panel allows user selection of display output, operating parameters, and initiation of span and clean air calibrations. This instrument is designed to operate indoors. A sample inlet line draws air into the measuring chamber while an external temperature sensor measures the ambient air temperature. Requires power supply capable of providing 13.8 VDC at 7 amps (connector parts are included), data-logging device, and span gas for calibration. Easy-touse data logging software is included (external PC with serial port is required for data logging software.) 88952 LED Option for NGN-2A or NGN-3A $795.00 The halogen lamp module and chopper for either NGN-2A or NGN-3A instruments can be replaced with a Luxeon Star V Green LED. This device extends the serviceable life to approximately 100,000 hours. Since the LED is electronically chopped, there is no need for the mechanical chopper and motor. However, the optical characteristics are different compared to the halogen lamp and the scattered values will not be the same. The LED has a center wavelength at 530nm with a bandwidth of 40 nm. NEPHELOMETER ACCESSORIES 86905 10 Amp power supply in NEMA enclosure for outdoor use. $375.00 10 amp regulated power supply with 13.8 VDC output mounted in weather-tight NEMA enclosure for outside installations. Recommended for use with NGN-2A instruments mounted on towers and other exterior installations. Mount this power supply as close to instrument as possible to minimize voltage loss in the cable. Includes connection points for input AC (100-240 volts) and connector parts for installer-made cables. 88905 10 Amp regulated power supply for indoor use. $225.00 10 amp regulated power supply with 13.8 VDC output. Includes 4-pin circular connector plus 2 banana plug connectors for larger gauge cables. Recommended for use with NGN-3A instruments. Not recommended for NGN-2A exterior installations. Will take any input voltage from 100 to 240 VAC. INDOOR USE ONLY. 88901 Custom cable assembly per customer specifications. $5.00 Cost per foot. CALL WITH SPECIFIC REQUIREMENTS. 88915 Span Gas apparatus and stand. $250.00 Tabletop stand allows easy attachment of the Suva 134a gas cylinder and includes pressure regulator and gauge along with all necessary hoses and fittings to connect directly to the nephelometer span gas input. The device is designed for indoor use only. Suva 134a is available in 1 lb. containers from most automotive supply stores.

TECHNICAL MANUAL 88015 Model NGN-2A Open-Air Integrating Nephelometer Technical Manual $10.00 88025 Model NGN-3A PM 2.5 Size-Cut Nephelometer Technical Manual $10.00 FIRMWARE 88690 PIC firmware upgrade for NGN-2A. $70.00 Latest PIC firmware for the NGN-2A instruments. (Call for latest version.) 88691 PIC firmware upgrade for NGN-3A. $70.00 Latest PIC firmware for the NGN-3A instruments. (Call for latest version.) 88692 EPROM software upgrade. $70.00 Latest version for the older style OPTEC-1 single-board computer used in the original NGN-2. (EEPROM firmware final release version NEPH1071.) REPLACEMENT COMPONENTS, SUBASSEMBLIES, AND SERVICES User Serviceable Components 88600 Clean air filter canister. $175.00 We suggest an extra canister be purchased so that the filter membrane can be replaced in the lab and not up 12 feet on the tower when replacing it. 88605 Replacement membrane filters, 0.5µm 47mm dia., package of 10. $35.00 88610 Replacement quartz halogen lamp. (all lamps are tested for proper output brightness) $29.00 88620 NGN-3/3A replacement temperature probe. $125.00 88625 PM 2.5 size-cut spiral sampler device, for NGN-3/3A. $395.00 Dealer Serviceable Subassemblies (Requires Trained Technician for Installation.) 88705 Rain detector for NGN-2. $127.00 88710 Chopper motor assembly. $275.00 88715 Clean air pump assembly. $393.00 88716 Replacement diaphragm for clean air pump. $20.00 88720 Door motor with gear head. $260.00 88721 Drive gear (small) for door motor improved with 17-4 stainless $67.00 88725 Exhaust port solenoid assembly. $127.00 88730 Exhaust fan assembly. $113.00 88735 Feedback detector/temperature sensor assembly. $260.00 88740 Span gas solenoid value assembly. $127.00 88745 Feedback/temperature board, complete. $233.00 88755 Scattered light detector board, complete. $527.00 88760 Telescope assembly. $227.00 88761 Objective lens for telescope. $73.00 88695 Replacement NGN-2A or NGN-3A computer/interface board $1,867.00 88910 Chopper motor replacement. (Requires return of chopper blade and bushing) $73.00 88920 Feedback/Temperature board repair, flat repair rate. (no discount) $50.00 88930 Scattered light detector board repair, flat repair rate. (no discount) $50.00 88935 Computer/Interface board repair, flat repair rate. (no discount) $370.00

88950 Rebuild NGN-2 or NGN-3 to current instrument standards, flat rate. (no discount) $2,500.00 Older NGN-2 and NGN-3 instruments with dual board computer/interface boards are not supported for firmware upgrades or electronic/electrical upgrades. If in reasonable condition, it is suggested that these instruments have the new NGN-2A or NGN-3A single board computer/interface installed along with a major upgrade of all parts. Everything listed in the annual maintenance described below is also included. 88951 Annual Maintenance of NGN instruments, (no discount) $800.00 Service includes: repaint the optical chamber flat black, replace the pump diaphragm, replace the lamp, remove and clean the scatter light detector telescope, replace telescope objective lens if needed, adjust telescope alignment, upgrade the firmware to the current version, replace clean air filter membrane, inspect and replace door motor gears if needed, replace cooling or vent fans if needed, complete electrical/electronic inspection and repair or replace any electrical/electronic component if needed, do zero air and span gas calibration. Documents showing work done and a calibration sheet are provided with the returned equipment. We keep a log of the instrument at Optec.