DEVELOPMENT OF THE CRYOGENIC CAPILLARY PUMPED LOOP

Similar documents
EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

TRANSIENT MODELING OF HYBRID LOOP HEAT PIPE SYSTEMS WITH MULTIPLE EVAPORATORS

This is a repository copy of Development of cryogenic loop heat pipes: A review and comparative analysis.

Experimental Investigation on the Effection of Flow Regulator in a Multiple Evaporators/Condensers Loop Heat Pipe with Plastic Porous Structure

Loop Heat Pipe Wick Fabrication via Additive Manufacturing

High Temperature Water-Titanium Heat Pipes for Spacecraft Fission Power

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

High Temperature Water Heat Pipes for Kilopower System

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Remote Helium Cooling Loops for Laboratory Applications

Sodium Heat Pipes for Spacecraft Fission Power Generation

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Diode Heat Pipes for Long-Lived Venus Landers

Operating Characteristics of Loop Heat Pipes

Variable Thermal Conductance Link for Lunar Landers and Rovers

10 K Airborne Cryocooler and

Design of Miniature Loop Heat Pipe

Heat transport capability and compensation chamber influence in loop heat pipes performance

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

15. Heat Pipes in Electronics (1)

Loop Heat Pipe Radiator Trade Study for the K Temperature Range

Ammonia and Propylene Loop Heat Pipes with Thermal Control Valves Thermal/Vacuum and Freeze/Thaw Testing

This is a repository copy of Experimental study on the supercritical startup of cryogenic loop heat pipes with redundancy design.

DEVELOPMENT OF PROPYLENE LHP FOR EUROPEAN MARS ROVER APPLICATIONS

EXPERIMENTAL STUDY OF DUAL EVAPORATOR LHP WITH TWO COMPENSATION CHAMBERS

Self-Venting Arterial Heat Pipes for Spacecraft Applications

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

DEVELOPMENT OF HEAT PIPE LOOP TECHNOLOGY FOR MILITARY VEHICLE ELECTRONICS COOLING

What is an Integrated Detector Assembly? Aron Traylor. College of Optical Sciences The University of Arizona 29 November 2010.

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

Numerical Simulation of a New Cooling System for Commercial Aircrafts

Temperature Oscillation of mlhp with Flat Evaporator

Design and Operation of a Cryogenic Nitrogen Pulsating Heat Pipe

Development of the Micro Capillary Pumped Loop for Electronic Cooling

20. Cooling Techniques for High Density Electronics (2)

Maluna Unhinged vs Yeti Tundra Thermal Performance Comparison January 2017

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

HOT or COLD. Condensation Happens. Chill Out! Boost Productivity. Keeping Up to Standard AS SEEN IN. August 2004

FORCED AIR CONVECTION THERMAL SWITCH CONCEPT FOR RESPONSIVE SPACE MISSIONS

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Thermal performances of a meter-scale cryogenic pulsating heat pipe.

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

A 2 K Active Magnetic Regenerative Refrigeration System for Remote Cooling

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

TWO-PHASE MICRO-CHANNEL HEAT SINK FOR SPACE CRAFT THERMAL CONTROL

Passive Control of a Loop Heat Pipe with Thermal Control Valve for Lunar Lander Application

RIGID DC LIQUID CHILLER

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Measurement of Reliability of Evaporator used in Vapour Compression Refrigeration System (VCRS)

Thermal Performance of a Loop Thermosyphon

Keeping COMMx. Before the U.S. Navy s TacSat-4. NRL Addresses a Hot TacSat-4 Challenge

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Heat sinks for electronic cooling applications

Thermal management architectures for rack based electronics systems. Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

Low GWP Refrigerants for Air Conditioning Applications

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Operating Characteristics of Multiple Evaporators and Multiple Condensers Loop Heat Pipe with Polytetrafluoroethylene Wicks

HVAC Water chiller selection and optimisation of operation

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Demonstration of a Two-Stage Turbo- Brayton Cryocooler for Space Applications

ABSTRACT INVESTIGATION THROUGH FLOW VISUALIZATION. Kimberly Reneè Wrenn, Doctor of Philosophy, 2004

Development of a Dilution Refrigerator for Low-Temperature Microgravity Experiments

Efficiency of Non-Azeotropic Refrigerant Cycle

The Art and Science of Being Cool

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Development of a meter-scale U-shaped Oscillating Heat Pipe for GAPS

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

Mini Vapour Cycle System For High Density Electronic Cooling Applications

Optimizing Chemistry and Coater Settings for Faster Drying

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Multi-Evaporator Hybrid Two-Phase Loop Cooling System for Small Satellites

Variable Temperature Microprobe Systems

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency


Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Micro capillary pumped loop system for a cooling high power device

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

Concept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Owner s Manual Therma-Stor II Heat Recovery System

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

DROP-IN EVALUATION OF REFRIGERANT 1234YF IN A RESIDENTIAL INTEGRAL HEAT PUMP WATER HEATER

Global Journal of Engineering Science and Research Management

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Operation of a Two-Phase Reverse Loop Thermosyphon

Transcription:

IECEC 98 I137 33rd Intersociety Engineering Conference on Energy Conversion Colorado Springs, CO, August 2-6, 1998 DEVELOPMENT OF THE CRYOGENIC CAPILLARY PUMPED LOOP Jane Baumann Brent Cullimore Ed Kroliczek David Bugby Cullimore and Ring Technologies, Inc. Swales Aerospace (303) 971-0292 (301) 586-1263 ABSTRACT A cryogenic capillary pumped loop (CPL) has been developed, designed, fabricated and successfully demonstrated by test. Using no moving parts, the novel device is able to start from a supercritical state and cool a remote dissipation source to 80-90K. Design studies were conducted for integration requirements and component design optimization and prototype units were designed, fabricated and successfully tested with excellent results. The development included the miniaturization of CPL technology to allow heat acquisition from sources with a small footprint and direct integration to a cryocooler cold finger. Applications include the cooling of cryogenic electronics, sensors, and fuels. The technology possesses many advantages over cryogenic heat pipes including ground testability and mechanical isolation. Because of the CPLs ability to transport loads over a distance, cryocoolers can be located remotely from the detector (up to a meter away or across a gimbaled joint). In addition, it passively seeks the coldest rejection environment, allowing a single cryogenic CPL to enable switching between multiple passive cryogenic radiators. This work was performed under funding from NASA Goddard Space Flight Center. INTRODUCTION CPLs are two-phase transport devices capable of transporting heat loads over long distances with minimal temperature drop across the system. The heat is acquired through the vaporization of the working fluid in an evaporator and rejected through condensation at a remote condenser. The system is passively pumped by means of surface tension forces developed in a porous wick structure located within the evaporator. For a further understanding of the room temperature CPL technology the reader is directed to Reference 1. The development of the cryogenic CPL expanded off the extensive design, development, and test heritage of room temperature CPLs to create a loop which is capable of starting and sustaining operation at cryogenic temperatures. The extrapolation of CPL technology to cryogenic temperatures offers performance benefits which are not currently within the reach of traditional heat pipes. Specific advantages of CPL technology as it pertains to cryocooler integration include: Improved ground testability due to greater capillary pressures Improved mechanical isolation Faster diode shut down and lower reverse heat leaks Tighter control of detector temperature Ease of integration due to their flexibility Perhaps the main reason designers should consider using cryogenic CPLs is that they intrinsically seek the coldest rejection environment. CPL technology has the ability to autonomously distribute heat to various sinks, switch between multiple sinks and provide diode action to prevent reverse heat transport from a hot sink.

Why CPL Versus LHP Technology Traditional western CPL technology is much more pliant to cryogenic applications than loop heat pipe (LHP) technology. An LHP (Reference 2) is a type of CPL which is characterized by the presence of thermal and hydraulic connections between the reservoir (compensation chamber) and the evaporator. This connection is typically achieved though a secondary wick between the evaporator and compensation chamber. The fact that the CPL does not have a similar connection is what allows the reservoir to be co-located with the condenser at the cryocooler. By co-locating the CPL reservoir and cryocooler and the addition of a hot reservoir to the system, fluid shuttling can be used to bring the device from room temperature to cryogenic temperatures (one of the major technical challenges of this development effort). The design attribute which provides robustness to room temperature LHPs, the connection between the compensation chamber and the evaporator, becomes the impediment which prevents their use at cryogenic temperatures. To drive an LHP below critical temperature, the compensation chamber would have to be co-located with the condenser at the cryocooler, thus requiring a capillary connection to the evaporator be carried across the transport section. This results in the same the orientation and flexibility constraints associated with cryogenic heat pipes due to the secondary wick in the compensation chamber. The second design limitation of LHPs, is the excessive design pressure a cryogenic LHP would experience at room temperatures. The presence of the hot reservoir in the cryogenic CPL minimizes this design pressure. PROGAM OVERVIEW During Phase I of this program (Reference 3), the feasibly of a cryogenic CPL was demonstrated. The design was developed through a series of thermal/fluid analyses which were performed to aid in the build of a breadboard unit and proof-ofconcept testing. A closed-cycle prototype loop was fabricated and tested in 1993 using nitrogen as the working fluid. Nitrogen was selected over oxygen as a working fluid because of superior performance in start-up, reduced reservoir sizing, and tolerance of liquid line heat leaks. Low costs and reduced concerns over safety and material compatibility are also appealing. The unit was designed for a 1 meter transport length and used an evaporator with room temperature heritage UHMW polyethylene wick. Demonstrations included start-up from a supercritical state and steady operation under powers ranging up to 7W at 90K. With this task the viability of cryogenic CPL technology was successfully established. The Phase II development (Reference 5) continued with the design and fabrication of third and fourth generation units. These designs focused on improved performance and component miniaturization for ease of integration. The Phase II development activities started with an industry search and survey to establish design criteria for the cryogenic CPL. This survey was following by a series of analytical studies which sought to optimize the design for performance, weight and mechanical envelope. Third and fourth generation units were designed and tested. The program successfully demonstrated system performance down to 1 watt at 90K with only 1.1K of subcooling required at the evaporator. CANDIDATE APPLICATION SURVEY An industry search and survey was conducted to optimize the development effort. The results of these surveys were rather surprising. In essence, it was found that existing cryocooler integration designs were limited by existing hardware options. In other words, since no prior hardware offered the functionality of CPLs, integration of CPLs into existing cryocooler systems was not as beneficial as a complete design overhaul. However, significant payoffs appeared to be possible if application engineers and CPL designers work together to develop new packaging configurations. The design goals selected resulted in technical challenges such as miniaturization and low heat loads. Extrapolation of the cryogenic CPL technology to applications with larger interfaces and larger heat loads is easily performed. Selection of Candidate Application A series of meetings was conducted with NASA/GSFC, JPL, AFRL in addition to conversations with various reviewers in industry. Based on the results, a plan was established to develop a light weight evaporator that can be used as a direct attachment for the focal plane array or at least be located inside the dewar. Ideally, the base plate on which the FPA is mounted, could be replaced by a dual CPL evaporator. The main design goals are summarized in Table1. IECEC-98-I137, August 1998 Page 2 of 8

Table 1: Cryo CPL Phase II Design Goals Attribute Goal/Requirement Nominal load 2 Watts Transport distance 0.2 meter Source temperature 80K Total temperature drop 3 to 5K Environment 10-5 Torr at 300K Maximum survival temp. 350 K integrally attached to the cryocooler cold fingers, thus eliminating thermal interfaces. This concept was defined as the baseline for the remainder of the development effort. System Integration At the completion of the Phase I study, the most probable concept for integration of the CPL into cryocooler applications was a single CPL strapping multiple cryocoolers as shown in Figure 1. This concept required multiple parallel condensers in a single CPL. This concept had significant impacts on several components of the cryogenic CPL such as the hot and cold reservoir designs, the two pass condenser layout and more significantly, the evaporator. Figure 1: Integration of Redundant Cryocoolers Even though the only known failure mechanism for cryogenic CPLs is loss of working fluid, the intolerance of the above depiction to this single fault drives the need for redundant CPLs, each with parallel condensers. Such a concept quickly becomes difficult to manage mechanically and thermally. Therefore parallel redundant CPL loops were pursued in which a dual stub-end evaporator would interface directly to the sensor or cold head and support heat acquisition for the two loops. A more mature concept is presented in Figure 2. The expected high reliability of cryogenic CPLs is exploited to accept redundant strings of CPLs and cryocoolers. The evaporators will be built into the detector chip carrier, and the condensers will be Figure 2: Current Concept; Parallel CPLs DESIGN OVERVIEW As stated prior, the cryogenic CPL is based on room temperature CPL technology. The third generation cryogenic CPL is shown in Figure 3. Modifications to the traditional loop design were required to extrapolate the technology to cryogenic temperatures. The first issue was the required start-up from a supercritical state. A traditional CPL has a single reservoir plumbed on the liquid return side of the loop. The cryogenic CPL has two reservoirs as shown in Figure 4, a cold reservoir (similar to the room temperature technology) and a larger hot reservoir. The hot reservoir is key to supercritical start-up. The hot reservoir is used in conjunction with the cold reservoir to shuttle the fluid between the two. This shuttling has the effect of chilling the evaporator mass below critical. The hot reservoir is also key in reducing the maximum operating pressure at room temperature for the cryogenic CPL. A second deviation from room temperature technology is the addition of a liquid cooled shield on the transport lines. This shield reduces the evironmental parasitics which can increase the loop temperature differential. For loops with a short transport section, the liquid cooled shield is not required. The last deviation in the development of the cryogenic CPL was the utilization of a stainless steel wick in the evaporator (room temperature technology has historically used polyethylene). IECEC-98-I137, August 1998 Page 3 of 8

Cold Reservoir Spool Transport Lines Figure 3: Photographs of the Cryogenic CPL The condenser required a three pass design to optimize the integration of the hot reservoir and the liquid cooled shield. In this system, the hot reservoir line passes over the spool to chill the fluid which is displaced from the hot reservoir during the start-up cycling before it enters the loop. The hot reservoir line is then plumbed into the midpoint (roughly) of the condenser. After the hot reservoir tee, the condenser line leaves the spool and is used to chill the liquid cooled shield shown in Figure 9. The condenser line then makes a second pass over the spool before returning to the evaporator. Figure 4: Cryogenic CPL Schematic Overview of the Start-up Process Evaporator The start-up process for the cryogenic CPL is unique in that the system must be brought below critical before the loop can be started. This process requires fluid shuttling between the hot and cold reservoirs. The cold reservoir and condenser spool are both heat sunk to the cold head of a cryocooler. The cold reservoir also has a heater on it. Initally as the cyrocooler cold head temperature drops, the cold reservoir and condenser are chilled. As the system pressure stabilizes and the cold reservoir reaches the desired operational temperature, the cold reservoir heater is enabled (referred to as a cold reservoir cycle). The heating of the cold reservoir expels cold fluid from the reservoir through the evaporator to the hot reservoir. This flow through the evaporator results in chilling of the evaporator and attached mass. The cold reservoir heater is then disabled after a few minutes. As the vapor in the cold reservoir recondenses, it pulls fluid from the hot reservoir through the evaporator and back into the cold reservoir. These cycles are repeated ( fluid shuttling ) until the evaporator temperature drops to saturation. At this point, a load can be applied to the evaporator to start the loop. Design Analyses Several models were developed for the steady state and transient design sizing using SINDA/FLUINT, the NASA-standard heat transfer and fluid flow analyzer for thermal control. These included detailed models of the evaporator case, steady state sizing of the hot and cold reservoirs and transient filling of the hot reservoir, and line sizing along with many others. The reservoir sizing analysis predicted the minimum cold and hot reservoir volumes required for the CPL based on system volumes and a sizing criteria. After calculating the minimum reservoir volumes required for a specific maximum design pressure, the analyses then predicted oversizing of both the cold and the hot reservoir for enhanced start-up. In the design of the fourth generation unit, the hot reservoir was oversized to bring the maximum design pressure to 2 MPa. Based on a minimum cold reservoir, the hot reservoir sizing based on design pressure is summarized in Figure 5. Predictions for oversizing both reservoirs are summarized in Figure 6. Transient Simulations The start-up transient thermal hydraulic model developed during Phase I was correlated to third generation test data. This model simulates the cyclic two-phase quenching during the chill down and startup of the cryogenic CPL. The SinapsPlus graphical depiction of the fluid network 1 is shown in Figure 7. The model was developed to account for cryocooler efficiency, temperature varying conductivities and specific heats, full-range fluid descriptions built into 1 SinapsPlus, developed by C&R Technologies, provides a complete graphical environment to SINDA/FLUINT for preand post-processing and interactive model debugging. IECEC-98-I137, August 1998 Page 4 of 8

FLUINT, and tank compliances are specified for smoother hydraulic response during transient simulations. The model also accounts for partial priming of the evaporator wick. This was achieved by using two parallel capillary pump devices in FLUINT, one representing the primed portion of the wick, the second representing the deprimed portion of the wick. This allows vapor to trickle back into the liquid core when partially primed. Additional logic was defined to evaluate the state of prime and then adjusts heat transfer coefficients within the evaporator and back conduction through the wick accordingly. A chill down transient from the correlated model is shown in Figure 8. This correlated data corresponds to the test data in Figure 10 herein. copper saddle which provided the one inch square sensor mounting surface. Figure 7: SinapsPlus Depiction of Fluid Network Figure 5: Minimum Hot Reservoir Volume Figure8: Correlated Start-Up Prediction Figure 6: Reservoir Oversizing DESIGN AND TEST Third and fourth generation units were fabricated and tested. The evaporator for both of these units was 1.5 inches long and 0.5 inch diameter with an active length of one inch. The body was fabricated from 316 stainless steel with a 2.6 micron stainless steel wick. The liquid line was plumbed as a bayonet to enhance core flushing during start-up and to increase vapor bubble tolerance. The evaporator was attached to a The condenser was fabricated from 0.065 inch outer diameter stainless tubing coiled on a spool fabricated from 7074-141 copper. Grooves where machined on the outer surface of the spool to accommodate the condenser lines. The spool is designed to attach directly to a cold head. The cold reservoir was fabricated from 316 stainless steel. The body is 1.62 inches long with an outer diameter of 1.185 inches and a wall thickness of 0.03 inch. The reservoir had an internal volume for expulsion of 16.26 cc and a total volume of 20.8 cc. The internal wick was machined from UHMW polyethylene. A reservoir heater was attached to the exterior of the body. The reservoir was thermally strapped to the cold head to provide the necessary cold bias required to enable positive heater control. The unit was gold plated to minimize parasitic heating from the environment during cool down and IECEC-98-I137, August 1998 Page 5 of 8

operation. Figure 9 shows the unit 2 with the liquid cooled shield in place and the gold plating. Figure 10: Chill Down Profile of CCPL Figure 9: CPL With Liquid Cooled Shield Summary of Test Results The results of the third generation test program were very positive. For this phase of testing, the unit was attached to an LN2 chilled plate in lieu of a cryocooler and placed in a ambient temperature vacuum chamber. The chamber was pumped down to <10-3 torr. The hot reservoir was located outside of the chamber. As shown in Figure 10, only two cold reservoir cycles were required to bring the evaporator and reservoir below 100K. A successful start-up was demonstrated at 90K with a 1.0 watt heat load and 1.1K of subcooling at the evaporator as shown at time=19:40 in Figure 11. The evaporator power was cycled up to 3 watts and back down to 0.5 watt. Additional tests were performed to further assess low power start-up and the parasitic heating. Figure 12 depicts the temperature profile with only parasitic loading. Five reservoir cycles were performed. Three were required to bring the system below critical temperature and the evaporator to the saturation temperature. Two additional cycles were performed for assurance. After the fifth cycle, 1 watt was applied to the cold reservoir. At approximately 16:12, the evaporator was at saturation with slight super heating of the liquid inlet. The sudden drop in the inlet temperature indicates a start-up on parasitic loading. At this point oscillations commence. These occillations are an indication of pumping on parasitic loading with insufficient flowrate to clear the vapor line. 2 Unit shown is actually the flight unit for the CRYOTSU demonstration. It is shown in lieu of the fourth generation unit due to photo quality of the fourth generation unit. Figure 11: Low Power Start-Up of CCPL Figure 12: Operation on Parasitic Loading The ability of the system to self-start under parasitic loads was an unexpected bonus. The system was expected to reach a theoretical stall speed when the load dropped below the minimum required to sustain operation. Repeated reservoir cycling would have been necessary to bring the system below critical after a stall. With the ability to operate on parasitic loading, the system remains at temperature. Only a single short reservoir cycle is required to clear the vapor in the evaporator core prior to application of the sensor load. The final test assessed low power start-up and the ability to continue low power operation over an extended time period. The system was started with a 1 watt load to the evaporator. The system operated IECEC-98-I137, August 1998 Page 6 of 8

very steadily while the power was incremented up to 3 watts and back down to 0.5 watt. At 0.5 watts oscillations commenced designating a low power threshold between 0.5 and 1 watt. Chill Down from Supercritical The fourth generation test program was performed in an ambient temperature vacuum chamber with the condenser spool attached to the 2nd stage of a 2-stage GM cryocooler. The testing was highlighted by the unexpected chill down of the unit with no fluid shuttling (cold reservoir cycling) as depicted in Figure 13. Further investigation and analysis of cooling capacities determined that the observed behavior was a result of a low rate of flow for fluid being pulled through the evaporator into the cold reservoir in response to the slow chill down rate of the cryocooler. In previous testing the chill down from ambient to 90K was achieved in 15 minutes versus the two hours required for the cryocooler used in this test. Due to the low flow rate, the evaporator mass chills more efficiently. The unexpected chill down transient required the development of a new start-up procedure for the system. Between the third and fourth generation test programs, the start-up procedure has been bounded for a large span of chill down rates. Figure 13: Start-up of the Fourth Generation Unit Fixed Conductance Operation The fourth generation unit was design for fixed conductance 3 operation. The unit was intentionally overcharged at the start of testing. After start-up, with the unit operational, charge was bled from the system until the desired temperature profiles where acquired. At the conclusion of the bleed process the system was properly charged for fixed conductance operation at 3 Fixed conductance operation is characterized by the hard filling of the reservoir. During this mode, saturation temperature floats to balance energy. See reference 6. evaporator loads of 4 watts. In this scenario, the system demonstrated the ability to transport 4.25 watts at 90K with a 3K differential between the evaporator and the condenser. Typical response to power cycling is shown in Figure 14. Figure 14: Fixed Conductance Power Cycling In summary, the system responded better than expected for fixed conductance. It was previously believed, that a cryogenic CPL charged for fixed conductance operation would exhibit start-up difficulties due to fluid distribution in the loop during chill down. Surprisingly, the system exhibited no start-up difficulties and operated in a very robust manor throughout the power cycling. Variable Conductance Operation The system was restarted at the lower charge level to verify start-up. After start-up, the system was excersised in variable conductance mode as shown in Figure 15. At a 4 watt load, the system had an 6K temperature differential between the evaporator and the condenser. Stable operation of the CPL continued as the reservoir power was reduced to 0.1 watt at which point the loop differential had decreased to 3K. At 0.1 watt on the reservoir, the reservoir temperature dropped slightly below the saturation indicating a 0.25W minimum load is required to retain reservoir control during variable conductance mode. Subsequent power turn down on the evaporator resulted in a system deprime as expected. With a short reservoir cycle to reprime the system, the CPL was back in operation at a 1 watt evaporator load within 15 minutes. CONCLUSIONS In summary, cryogenic CPL technology has successfully been demonstrated to be capable of providing 1 to 7 watts of cooling capacity at 90K with minimal temperature differential across the loop. This new technology offers cryogenic system designers an option to locate cryocoolers remotely in IECEC-98-I137, August 1998 Page 7 of 8

addition to having unsurpassed off resistance and vibration isolation. Continuing efforts at Swales Aerospace will provide the first flight experiment 4 of the cryogenic CPL in 1998 on the CRYOTSU gas canister through funding from Phillips Laboratory and NASA GSFC. This experiment will verify the 0-g operation of the cryogenic CPL. The unit to be flown, shown in Figure 9, is identical to the fourth genertion unit described herein with the execption of more complete gold plating. This effort has demonstrated and matured cryogenic CPL technology thus opening a new, versatile and exciting integration option for the design of future cryogenic systems. Potential spin-offs from this development include the miniaturization of CPLs for room temperature applications in addition to the metal wick technology which can increase pumping capacity by an order of magnitude over existing polyethylene wicks for ammonia systems. A spin-off development funded by BMDO and Phillips Laboratory demonstrated the successful start-up from supercritical and subsequent operation of a neon unit for applications in the range of 30-40K (Reference 4). 3) Cullimore, B., Cryogenic Capillary Pumped Loop Final Report for Phase I, NASA/GSFC Contract NAS5-32415, June 1993 4) Bugby, D., Kroliczek, E., Cullimore, B., Baumann, J., Experimental Investigation of a Neon Cryogenic Capillary Pumped Loop, 32nd IECEC, No. 97272, 1997 5) Baumann, J., Cryogenic Capillary Pumped Loop Final Report for Phase II, NASA/GSFC Contract NAS5-32415, July 1997 6) Cullimore, B., Constant Conductance Mode in Capillary Pumped Loops, January 1996 7) Bugby, D., Nguyen T., Kroliczek, E., Ku, J., Swanson, T., Cullimore, B., Baumann, J., Development and Testing of a Cryogenic Capillary Pumped Loop Flight Experiment, IECEC-98-I288, August 1998. Figure 15: Variable Conductance Operation REFERENCES 1) Ku, Jentung, Overview of Capillary Pumped Loop Technology, National Heat Transfer Conference, August 1993 2) Maidanik, Vershinin, Kholodov, Dolgirev, U.S. Patent Documents, Heat Transfer Apparatus, #4515209 4 Reference 7 has a more complete discription of the flight experiment. IECEC-98-I137, August 1998 Page 8 of 8