WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

Similar documents
BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

Fireboxes: (NL)FB32C, (NL)FB36C, FB42C, (NL)UV32C, CGFB32C and CGFB36C Series. Stoves: CSDBN, SDVB, MSDVB MSTD, CDV, S39T and S26T Series

FIREPLACE INSTALLATION

GA3650TB Blower Accessory

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

BF5000NT BF5000 EF2604 SF2603 DF2603

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

PARTS & SERVICE MANUAL

UNVENTED (VENT-FREE) UNIVERSAL FIREBOX OWNER S OPERATION AND INSTALLATION MANUAL PFS

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

Service Manual. Model Number: DF2426 DF2550 DFG2562 BF9000. UL Part Number to

DIRECT-VENT FIREPLACE

INSTALLATION. Glass Panel Doors (select models) CAUTION

DIRECT VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL MODELS CD32M-LS AND CD32MB-LS

GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4GWSS ZDP48N6RWSS ZDP48N6DWSS

UNVENTED (VENT-FREE) PROPANE/LP GAS FIREPLACE

UNVENTED (VENT-FREE) UNIVERSAL FIREBOX OWNER S OPERATION AND INSTALLATION MANUAL

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

Service Manual. Model Number: DF2426 DF2550 DFG2562 BF9000. UL Part Number to

Service Manual. Model Number: DF2426 DF2550 DFG2562 BF9000. UL Part Number to

IMPORTANT SAFETY INFORMATION

installation and operation manual for Hunter Ceiling Fans

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

DIRECT-VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

UNVENTED (VENT-FREE) PROPANE/LP GAS FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

Installation Instructions

Service Manual 26 Self Trimming Export Fireplace with 3 Stage On/Off Remote

Installation Instructions

Table of Contents. What to Expect with. Mounting Options. Tools Needed

PARTS AND SERVICE MANUAL FOR. DIMPLEX PURIFIRE ELECTRIC STOVE Model TDS8515

PRO Series Energy Star Ceiling Fan Owner's Manual

GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4G ZDP48N6R ZDP48N6D

Tommy Bahama INDOOR/OUTDOOR 52 in. / 132 cm. CABRILLO COVE CEILING FAN

Rear Blower Installation Instructions

Installation. Leveling

INSTALLATION INSTRUCTIONS

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

IMPORTANT SAFETY INFORMATION

Service Manual 23 Compact Fireplace Model Number: DF2305

MC-UL Vacuum Cleaner. Specifications are subject to change without notice for further improvement. Order Number MAC CE

IMPORTANT SAFETY INFORMATION

Summer Breeze Heater Service Manual

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

Installation Instructions

Installation Instructions

DIRECT-VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL. NATURAL GAS TUDOR MODELs (V)T36NA SERIES. PROPANE/LP GAS TUDOR MODELs (V)T36PA SERIES

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

READ AND SAVE THESE INSTRUCTIONS XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX COPA BREEZE

DIRECT-VENT FIREPLACE

DIRECT-VENT FIREPLACE

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

ST. KITTS CEILING FAN

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

INSTALLATION INSTRUCTIONS

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

installation and operation manual for Hunter Ceiling Fans

Service Manual. Model Number: DWOP20R. UL Part Number

5GFR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5GFR52XXD

21 TRV Blower Installation Instructions

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock -

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

INSTALLATION INSTRUCTIONS

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

Owner s Guide and Installation Manual

INSTALLATION INSTRUCTIONS

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

INSTALLATION INSTRUCTIONS

HX Field Replacement Kit

8TNR56XXXD-V1 Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 8TNR56XXXD-V1

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Installation Instructions

High-Density Industrial

Food Waste Disposer Instruction Manual

BAY BRIDGE CEILING FAN

Service Manual Compact Stove

Lifetime Limited Warranty

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

Owner s Guide and Installation Manual

WARNING. Tighten strain relief screws to secure cable. Make sure screw heads are facing up when tightening conduit nut.

Commercial Stacked Dryers Metered and Nonmetered Refer to Page 3 for Model Numbers

MC-V Vacuum Cleaner. Specifications are subject to change without notice for further improvement.

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

TECHNICAL INFORMATION Touchtronic Clothes Dryers

Table of Contents. What to Expect with. Mounting Options. Tools Needed

DIRECT-VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

Undercounter Refrigeration

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

DIRECT-VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL

Owner s Guide and Installation Manual

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

CEILING FAN OWNER S MANUAL

Ceiling Fan Installation Instructions

Installation Instructions

Transcription:

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS Model BK Manually led Blower Model BKT Thermostatically led Blower WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. (Check your appliance owner s manual for specific applications and additional instructions.) Parts included with this kit BK BKT Part No. Description Qty 103581-04 Blower Assembly with Speed and 6 foot Cord 1 104901-01 Wire Assembly 1 103650-01 Knob 1 103651-01 Lock Nut 1 11125 #8-1/2" Phillips Head Screw 1 101378-01 Thermodisc Switch, 100 Limit 1 104902-02 Switch Mounting Bracket 1 109892-01 Speed Bracket (Stamped Face Models) 1 109892-02 Speed Bracket ( Louver Models) 1 Tools Required Pliers Phillips Screwdriver Flat Blade Screwdriver If any of these pieces are missing or damaged, or if the installation instructions for your fireplace or stove are not included in this manual, contact the dealer where you purchased this kit or DESA Heating Products at 1-866-672-6040 for referral information.

The BK and BKT blowers utilize the same rotary squirrel cage type blower with magnetic attachment and variable speed control. The BKT also includes an additional thermostatically controlled feature for use on some direct-vent models only. The BK blower can be installed in wood burning, B-vent and vent-free model fireplaces. Both the BK and BKT blowers can be installed in directvent model fireplaces. Blowers are installed by accessing the blower compartment through the lower louver panel or, on some models, through the control access cover under the front refractory panel (see Figure 1). The lower front louver panel can be removed easily, see Removing Louver, page 3 for instructions. WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area (see Figure 2), be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury. Front Refractory Access Cover Knockout Plug Lower Louver Figure 1 - Accessing Blower Compartment (s Not Shown for Clarity) B-Vent, Wood and Vent-Free Models Duplex Electrical Outlet Figure 2 - Accessing Duplex Electrical Outlet Installed in Bottom Right Side of Firebox 2 www.desatech.com 108998-01E

Removing Louver Wood, B-Vent and Vent-Free Models For models other than direct vent, remove panel or stamped face louver by snapping out the front with a flat blade screwdriver (see Figure 1, page 2). Use caution not to scratch any surfaces. These panels can also be removed by inserting fingertips between slots and gently pulling out. DO NOT FORCE. The panels are actually held in place by means of a retention dimple embossed on the edge of the panel. To reinstall, place louver into cavity and push gently. Direct-Vent Models There are two different types of direct vent louvers: spring latch and bullet-style clip. Spring Latch: Remove louver with spring latches by simultaneously pulling both top spring latches toward the center of the appliance until they are disengaged from the locating holes. Repeat for bottom spring latches and pull louver outward (see Figure 3). To reinstall, simply reverse procedure. Bullet-Style Clip: Remove louver with bulletstyle clips by using a flat blade screwdriver and snapping louver forward. Use caution not to scratch any surfaces. These panels can also be removed by inserting fingers between slots on louver and gently pulling out. DO NOT FORCE (see Figure 4). To reinstall, align bullet-style clips with locating holes on inside of firebox and push gently. Rolled Louver Spring Latch Figure 3 - Removing Louver with Spring Latches (Direct-Vent Models) Locating Holes Louver Bullet-Style Clips Figure 4 - Removing Louver with Bullet-Style Clips (Direct-Vent Models) 108998-01E www.desatech.com 3

Model BK wire assembly Note: Speed control switches can not be installed into filigree panels. Installing a wall switch or rheostat in the wall outside of fireplace will eliminate removing bottom louver to adjust operation of blower. 1. Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 5). 2. Attach green ground wire from power cord to blower housing using screw provided (see Figure 5). Tighten screws securely with a phillips screwdriver. 3. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. Depending on your model, you may have to carefully route the blower assembly past the controls and brackets, and position the blower inside the back opening. The blower will be held in position against the back wall by the magnets incorporated onto the blower housing (see Figure 5). 4. Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green ground wire is tight. Spade Terminals Magnetic Strips Exhaust Port Model BKT wire assembly Note: The BKT blower is for application into direct-vent models only. When installing the BKT thermostatically-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed. 1. Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower assembly. Insert the phillips screw into all three pieces and tighten securely (see Figure 6). 2. Connect wire harness and power cord terminals. Connect the jumper wire to the blower motor terminal and the right side terminal of the thermal switch. Connect one wire to the left side of the thermal switch and one wire to the other remaining blower motor terminal. Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely. Power Cord Thermal Switch Bracket To Thermal Switch To Blower Motor Terminal Jumper Wire Magnetic Strips Air Flow Direction Green Ground Wire Screw Blower Installed After Lower Removed Blower Location Air Flow Direction Phillips Screw Thermal Switch Route BKT Blower Through This Area Ring Terminal on Green Wire Thermodisc Blower Location Air Flow Direction Side View Firebox Bottom Figure 5 - Blower Model BK Magnets Side View Firebox Bottom Figure 6 - Blower Model BKT Magnets 4 www.desatech.com 108998-01E

Model BKT wire assembly Continued 3. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 6 in order to sense temperature and properly operate. The blower will be held in position against the back wall by the magnets incorporated onto the blower housing (see Figure 6, page 4). 4. Be certain that all wire terminals are securely attached to terminals on blower motor and thermal switch, and that the screw for the thermodisc bracket and green ground wire is tight. 5. To mount speed controls, see Mounting Speed for All Direct Vent Models (below), Mounting Speed for All Models with Louvers (column 2) or Mounting Speed for All Models with Stamped Face Louvers (page 5), depending on your model. Mounting Speed Direct-Vent Models 1. Mount the speed control box by placing the plastic control shaft forward through the mounting opening on the pre-installed bracket (see Figure 7). 2. While supporting the speed control in the vertical position, secure the control shaft by pushing and turning the lock nut with pliers until it is tight against the mounting bracket. Place control knob provided on the control shaft (see Figure 7). Models with Stamped Louvers Wood, B-Vent and Vent-Free Models 1. Position speed control bracket by inserting flange of bracket between hearth pan and upper flange of louver opening, then seat bottom end of bracket onto lower flange of louver opening (see Figure 8). 2. Mount speed control box by placing plastic control shaft through bottom hole on speed control bracket. Top screw head on control box will fit inside top hole on bracket (see Figure 8). Secure speed control to bracket with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against bracket. 3. Remove knockout plug from louver panel by depressing top and bottom retaining clips (see Figure 1, page 2). 4. Place louver panel, louvers pointing up, back into framed opening. Align control shaft with rectangular opening by sliding control bracket along flange (see Figure 8). 5. Fully seat louver panel into frame opening by gently pressing along ends until all dimpled retainers have snapped in place. 6. Place control knob, provided, onto control shaft (see Figure 8). Firebox Face Bottom Front Refractory Hearth Pan Flange Speed Bracket Bottom Rear Refractory Shaft Pre-Installed Bracket (Direct-Vent Only) Shaft Lower Flange Lock Nut Speed Knob Lower Louver Knob Lock Nut Figure 8 - Attaching Speed to Firebox with Louvers Using Speed Bracket 109892-02 Figure 7 - Attaching Speed to Direct-Vent Firebox 108998-01E www.desatech.com 5

Mounting Speed Continued Models with Stamped Face Louvers (B36, VB36 Wood Burning Units) 1. Using pliers, bend two retaining tabs on speed control bracket 90 degrees to front of bracket (see Figure 9). 2. Mount speed control box by placing plastic control shaft through bottom hole on speed control bracket. Top screw head on control box will fit inside top hole on bracket (see Figure 9). Secure speed control to bracket with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against bracket. Knob Firebox Face Louver 3. Remove knockout plug from louver panel by depressing top and bottom retaining clips (see Figure 1, page 2). 4. Position speed control assembly over flange on hearth pan by sliding bracket up between the face and the flange, then down until the control shaft is aligned with the opening in the louver panel (see Figure 9). 5. Lock two retaining tabs onto lower louver by pressing down on bracket assembly while sliding control knob through rectangular opening on louver and onto the control shaft (see Figure 9). Speed Bracket with Assembly Hearth Pan Flange Shaft Retaining Tab Speed Bracket Screw Head and Top Hole on Bracket Lock Nut Retaining Tabs Shaft Figure 9 - Attaching Speed to Firebox with Stamp Faced Louvers (B36 and VB36 Models) Using Speed Bracket 109892-01 6 www.desatech.com 108998-01E

Connecting power and operating blower 1. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Also double check all wire leads and make sure wire routing is not pinched or in a precarious position. Correct accordingly. CAUTION: Never touch the blower wheel while in operation. 2. Turn on power to duplex outlet if previously turned off per the warning on page 2. 3. Plug in blower power cord to duplex outlet (see Figure 2, page 2). 4. BK Model: Turn blower on and check for operation. Turn blower off by turning knob fully counterclockwise before continuing. BKT Model: The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be adjusted by rotating the control knob. To turn off, turn knob fully counterclockwise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically. 5. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 10). 6. Replace all panels and/or brick bottom if previously removed. Wiring Diagram Decal 12" in Front of Blower Figure 10 - Location of Wiring Diagram Decal (Model May Vary From Illustration) 110/115 V.A.C. Off (BKT Model Only) Black Green White Variable Fan Switch 1 2 Black On Blue Fan Switch (N.O.) Red Blower Motor Figure 11 - Wiring Diagram 108998-01E www.desatech.com 7

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Technical Service Department 1-866-672-6040 www.desatech.com 108998 01 NOT A UPC 108998-01 Rev. E 10/05