official distributor of Newson Gale Ltd.

Similar documents
Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

Earth-Rite II PLUS Static Earthing System

Newson Gale. Cen-Stat Static Grounding clamps, cables and reels. Leading the way in hazardous area static control. IECEx

Grounding & Bonding Applications

INSTRUCTION & SERVICE MANUAL

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Certificate of Compliance

Fixed Gas Detection System/Meridian CERTIFICATION

Guide for hazardous areas

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

standards: standards:

SOLUZIONI PER ATMOSFERA ESPLOSIVA

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Electrical Installations Design, Selection, Erection and Inspection

4) Intrinsic Safety Certification

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Certification Supplement Manual

INSTRUCTION MANUAL (ATEX / IECEx)

UL HAZARDOUS LOCATIONS SERVICES

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

OPTIBAR DP 7060 Supplementary Instructions

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

Operating Instructions

IECEx Certificate of Conformity

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

Inductive slot sensor

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

srra, of Conformity IECEx Gert f cate ?-ot,b

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Electrostatic Hazard Control in Process Industry using Multi Channel Earth Monitor

Operating instructions for HAWE devices

Manual Alarm Call Points

Certification Supplement Manual

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX / IECEx)

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Certification Supplement Manual

Rosemount 4500 Hygienic Pressure Transmitter. Start

INSTRUCTION MANUAL (ATEX / IECEx)

Approvals, Certificates and Conditions

Control Panels Switchgear Motors Generators Analysers Rooms/Buildings. Pressurized Enclosure. Static Pressurization. Leakage Compensation (LC)

Guide to Intrinsically Safe Portable Radios

Survey of electrical equipment installed in hazardous areas on tankers

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

INTRINSICALLY SAFE LIGHTING RANGE

DESCRIPTION. 42 mm. 125 mm

Certificate of Compliance

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Technical Data. Dimensions

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Certificate of Compliance

Hazardous Area Portable Fan Heater The Bulldog

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Annubar Flowmeter Series

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Technical Data. Dimensions

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Technical Data. Dimensions

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Technical Data. Dimensions

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Certificate of Compliance

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

PANELBOARD PROTECTION ON A GLOBAL SCALE

Integrated Solutions Low Voltage Systems

DTS Light fittings for explosive atmospheres

zonex enclosures hazardous locations

ATM Lighting sp. z o.o

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

GasAlertMicroClip X3 Specifications

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

distributing & controlling system solutions

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Hazardous Area Portable Fan Heater The Bulldog

Certificate of Compliance

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

MT5000 Guided Wave Radar Level Transmitter. State-of-the-art loop powered, 4-20 ma output guided wave radar transmitter for liquid level applications

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Overview of Hazardous Locations as They Relate to Solenoid Valves

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Temperature Measurement Transmitters for field mounting

Rosemount 2090F Hygienic Pressure Transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

ATM Lighting sp. z o.o

Dräger Flame 2500 Flame Detection

Quick Start Guide For the

Transcription:

Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container or other conductive item of plant in a complete loop made through the designated grounding point. Enquiry > Click here to submit a product related query or a request for quotation. Static dissipative GRP enclosure The indicator station houses the ground loop monitoring circuit and a bright green LED which pulses continuously when it detects that the resistance between the equipment to be grounded and the site s verified earth ground (e.g. copper tape) is 10 ohms or less. Once connected the Bond-Rite REMOTE continuously monitors the resistance of the circuit between the equipment and the verified ground point (e.g. wallmounted bus bar). The pulsing green LED provides process operators with a continuous visual reference point that enables them to monitor the ground status of equipment at risk of accumulating static electricity and discharging static sparks. The standard GRP enclosure is static dissipative and suitable for general processing environments. The stainless steel enclosure (SS 304) is designed to cater for hygienic or corrosive environment specifications. Both enclosures provide a minimum IP 65 degree of ingress protection and are suitable for both indoor and outdoor installation. The can be powered with an intrinsically safe 9V battery (included) or an external 230/115 V AC power supply which can power up to 10 individual indicator stations. The is an ideal solution for applications and installations where interlocks with the process are not possible. Typical Applications > Filling and dispensing to/from metal containers, including drums, waste drums, mixing vessels. > Grounding equipment used in mixing and blending operations. Newson Gale For over 30 years Newson Gale has been supplying the chemical and processing industry worldwide with its market leading range of static control products ensuring people and plant are protected from static related fires and explosions.

( EP ) For process applications that require grounding for more than 6 hours per day, the EP (EP = Externally Powered) utilises 230V AC or 115 V AC mains supply / line power to power the monitoring circuit of each indicator station. The external power supply can be located in both the hazardous (Zone 2/22 Div.2) and non hazardous areas, with the indicator stations mounted in the zoned / HAZLOC area (Zone 0 / Div.1) or lower. When used in conjunction with the Newson Gale Universal power supply, up to 10 indicator stations can be powered simultaneously. This enables users to actively monitor up to 10 items of plant equipment at risk of electrostatic charging (e.g. drums) independently of each other. An additional advantage of this configuration is that the external power supply itself can be installed within the hazardous area. For more detailed information please refer to the / and ccsaus technical specification pages. Stainless steel enclosure. Features and Benefits > Highly visible LED housed in wall mounted enclosure ensures operators know when a low resistance connection is achieved with potentially charged equipment. > Tungsten carbide teeth bite through product deposit build up, rust & drum coatings to ensure proper bonding connections are made. > 10 ohms loop resistance monitoring compliant with international Recommended Practice*. > Indicator station mounted stowage pin provides operators with location to return the grounding clamp when the operation is finished. > Stainless steel clamps designed to withstand use in tough chemical processing and industrial environments. Ideal for multiple drum filling applications *IEC 60079-32, Explosive atmospheres: electrostatic hazards, guidance. *NFPA 77, Recommended Practice on Static Electricity. The Bond Rite REMOTE forms part of the Bond Rite range of Static Grounding and Bonding Equipment available from Newson Gale.

(GRP) Technical Specification [GRP] - Battery Powered and Mains Powered Ingress Protection IP 65 Ambient Temperature Range 40 C to +60 C Operational Ground Resistance Nominally 10 Ohm Pulsing LED O6mm Indicator Lamp LED: 1 green (Ground / Earth connection healthy) Battery Supply option Power Supply option 9 V Lithium Manganese Battery (supplied with unit) Newson Gale Universal Power Supply Enclosure Material Glass Reinforced Plastic (carbon loaded) Hazardous Area Certi cation 12 x 7 (mm) Slot Quick Connect (x1) Europe / International: Ex ia IIC T4 Ga (Gas & Vapour). Ex ta IIIC T135ºC Da (Combustible Dusts). SIR 09.0023X certifying body: SIRA. II 1 GD Ex ia IIC T4 Ga Ex ta IIIC T135ºC Da Sira 092158X Notified Body: SIRA. North America: NEC 500 / CEC (Class & Division) Intrinsically safe equipment Exia for use in: Class I, Div. 1, Groups A, B, C, D. Class II, Div. 1, Groups E, F, G. Class III, Div. 1. Ta = 40 C to +60 C. Ta = 40 F to +140 F Control Drawing: BRR Q 11185 ccsaus OSHA recognised NRTL: CSA. NEC 505 & 506 (Class & Zoning) Class I, Zone 0, AEx ia IIC T4 Ga (Gas & Vapour). Class II, Zone 20, AEx iad 20 T135ºC, (Combustible Dusts). Stowage Pin 1 x M20 gland entry for Externally Powered version 95mm CEC Section 18 (Class & Zoning) Class I, Zone 0 Ex ia IIC T4 Ga DIP A20, IP66, T135ºC

( Stainless Steel ) Technical Specification [Stainless Steel] - Battery Powered and Mains Powered Ingress Protection IP 65 Ambient Temperature Range 40 C to +60 C Operational Ground Resistance Nominally 10 Ohm Resistance Indicator Lamp LED: 1 green (Ground / Earth connection healthy) 96mm O10mm Pulsing LED Battery Supply option 9 V Lithium Manganese Battery (supplied with unit) Power Supply option Newson Gale Universal Power Supply Enclosure Material Stainless Steel (SS 304) 176mm 150mm Hazardous Area Certi cation 150mm Europe / International: Ex ia IIC T4 Ga (Gas & Vapour). Ex ta IIIC T135ºC Da (Combustible Dusts). SIR 09.0023X certifying body: SIRA. II 1 GD Ex ia IIC T4 Ga Ex ta IIIC T135ºC Da Sira 092158X Notified Body: SIRA. North America: NEC 500 / CEC (Class & Division) Intrinsically safe equipment Exia for use in: Class I, Div. 1, Groups A, B, C, D. Class II, Div. 1, Groups E, F, G. Class III, Div. 1. Ta = 40 C to +60 C. Ta = 40 F to +140 F Control Drawing: BRR Q 11185 ccsaus OSHA recognised NRTL: CSA. NEC 505 & 506 (Class & Zoning) Class I, Zone 0, AEx ia IIC T4 Ga (Gas & Vapour). Class II, Zone 20, AEx iad 20 T135ºC, (Combustible Dusts). 1 x M20 gland entry for Externally Powered version CEC Section 18 (Class & Zoning) Class I, Zone 0 Ex ia IIC T4 Ga DIP A20, IP66, T135ºC Stowage Pin for Grounding Clamp 81mm

Universal Power Supply (UPS) Technical Specification Newson Gale Universal Power Supply Unit Ingress Protection IP 66 Ambient Temperature Range 40 C to +55 C Power Supply 110/120 V or 220/240 V AC, 50 60 Hz O6mm Enclosure construction Glass Reinforced Plastic (carbon loaded) Hazardous Area Certi cation Europe / International: Ex na[ia] IIC T4 Gc(Ga). Ex tb IIIC T70ºC Db IP66. Ta = 40ºC to +55ºC. SIR 09.0089 certifying body: SIRA. II 3(1) G II 2D Ex na[ia] IIC T4 Gc(Ga) Ex tb IIIC T70ºC Db IP66 Ta = 40ºC to +55ºC. Sira 092210 Notified Body: SIRA. North America: NEC 500 / CEC (Class & Division) Associated Equipment [Exia] for use in: Class I, Div. 2, Groups A, B, C, D; Class II, Div. 2, Groups E, F, G; Class III, Div. 2. Providing Intrinsically safe circuits for: Class I. Div. 1, Groups A, B, C, D; Class II, Div 1, Groups E, F, G; Class III, Div 1. When installed per Control Dwg ERUPS Q 09212 Ta = 25 C to +55 C. Ta = 13 F to +131 F OSHA recognised NRTL: CSA. NEC 505 & 506 (Class & Zoning) Class I, Zone 2 (Zone 0) AEx na [ia] IIC T4 (Gas & Vapour). Class II, Zone 22, AEx td [iad] 22 T70ºC, (Combustible Dusts). 12 x 7 (mm) Slot Bond-Rite 240V / 110V ac power supply for Zone 2, 21, 22 and Class I, II & III Div.2 locations or Non-Hazardous locations. 121mm 121mm 4 Entry Junction Box 260mm CEC Section 18 (Class & Zoning) Class I, Zone 2 (Zone 0), Ex na [ia] IIC T4 DIP A22 T70ºC Additional Certi cation EMC Tested: to EN 61000 6 2, EN 61000 6 3 to FCC Part 15 10 Entry Junction Box

Equipment Options Newson Gale supplies a range of product options that enhance the control and general safety of transfer processes and aid engineers with system installations and routine system service checks. Cable length options Equipment specifiers can order the with 2-pole Cen- Stat cable on standard spiral lengths of 3 m (10 ft.), 5 m (16 ft.) and 10 m (32 ft.) of cable. The spiral cable provides effective retractability when the clamp is not in use, ensuring the cable is neatly stowed and safely out of the way. Cen-Stat cable supplied with male and female in line Quick Connects. Universal Resistance Tester The URT is designed to provide installers and maintainers of Newson Gale Earth-Rite and Bond-Rite static grounding systems with a means of regularly testing the grounding settings for their system on a routine basis. Periodic testing with the URT verifies that the grounding system s GO/NO GO settings are working in compliance with the recommendations of: NFPA 77: Recommended Practice on Static Electricity. IEC 60079-32-1: Explosive atmospheres. Part 32-1: Electrostatic hazards, guidance. The easy to use tester consists of a pair of rotary switches that enable a competent electrical person to check the resistance level at which the grounding system should be working and conduct a PASS / FAIL test at the required setting. Universal Resistance Tester Product Code: URT. Bond-Rite products that can be tested with the URT include: > Bond-Rite CLAMP > Bond-Rite EZ >

Product Ordering Codes static dissipative GRP indicator station options Battery Powered (B) Externally Powered (EP) B EP Certification North America BRRPEB1B2 BRRPEB2A2 BRRPUB1B2 BRRPUB2A2 BRRPEP1B2 BRRPEP2A2 BRRPUP1B2 BRRPUP2A2 ER/UPS/AC H Universal Power Supply for powering Bond Rite REMOTE EP units. add H to product code in order to specify stainless steel Sunlight hood Stainless Steel indicator station options Battery Powered (B) Externally Powered (EP) B EP Certification North America BRRMEB1B2 BRRMEB2A2 BRRMUB1B2 BRRMUB2A2 BRRMEP1B2 BRRMEP2A2 BRRMUP1B2 BRRMUP2A2 ER/UPS/AC H Universal Power Supply for powering Bond Rite REMOTE EP units. add H to product code in order to specify stainless steel Sunlight hood X45-IP 120 mm / 4 7 in X90-IP 235 mm / 9 in NOTE: For a complete Bond Rite REMOTE EP installation, the power supply module (ER/UPS/AC) must be ordered with the required number of remote indicator stations. Up to 10 Bond Rite REMOTE indicator stations can be powered by a single ER/UPS/AC universal power supply. Different lengths of spiral cable available on request. Contact your local Newson Gale office, or preferred supplier, for more options. X45-IP: Designed for grounding 250 litre closed drums and smaller containers. X90-IP: Designed for grounding 250 litre drums and larger containers. Contact Us > Your enquiry will be processed rapidly via our webform enquiry service. If you would prefer to call us, or e-mail us, please use the contact details provided below. NG UK BRR 300616 R6