Active Infrared Multi Beam Sensors. R Series

Similar documents
Active Infrared Multi Beam Sensors

Long-Range Barrier Sensors

Twin Photobeam Detectors Manual

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

DUAL OPTIC. Installation manual

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Commercial Series TriTech Motion Detector. Reference Guide

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

English. Series. Installation and Use Manual

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Installation And commissioning manual. Series S Double Beam 1/16

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Movement Detector GJD 300

D-Tect 2 GJD300 Quad PIR Movement Detector

Solar Powered Wireless Photobeam Sensors

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

CONFIGURATION OF THE OPTICALS

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Commercial Series TriTech+ Motion Detector with Anti-mask

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INDEX. Installation recommendation

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Immunity. P/N: ver.b

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Warranty Registration

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

Ultrasonic Reflective Sensor

HI Industrial Utility Heater HI Soleus Air International

Extended Range DUAL TEC Motion Sensor

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

D-TECT Dual Tech. GJD360 Triple Technology External Detector

PTE0705 Electric Fence Monitor

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Long Range Radio Alarm Transmitter

PARVIS Safe and tranquil thanks to Parvis

Ultrasonic Reflective Sensor

ACL TC 200 TEMPERATURE CONTROLLER

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

Home Doorway Alert Kit

Installation Instructions

Premier External TD. Installation Manual INS352-3

RK Carbon Monoxide Transmitter Operator s Manual

Beacon 800 Gas Monitor Operator s Manual

Installation Manual Premier LCD/LCDL INS180-4

IMPORTANT SAFETY INFORMATION

Model: SFE-ST FOR YOUR SAFETY ANSI / UL INSTALLER: DO NOT DISCARD THIS MANUAL -- LEAVE FOR HOME OWNER BUILDER BOX

RK CO 2 Transmitter Operator s Manual

Description. Optex Incorporated

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

52 CEILING FAN. Owner s Manual Models #50336, 50337

Radio Frequency Do s & Don ts

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

INDEX. Installation recommendation

STRONG International FP-350 Operation and Installation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

CT-7 Series Toxic Gas Transmitter Operator s Manual

OPERATING INSTRUCTIONS

FSLIMPRO

Installation Instructions

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

PIR-100B User Manual

CO2 Sensor User and Installation Guide

INDEX. Installation recommendation

Analog Room Pressure Monitor RPC Series

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

English. Italiano. Português. Françias. Español

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

Long Range Radio Alarm Transmitter

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

KM300 Carbon Monoxide Detection System Installation Manual

D-TECT 3 IP. GJD260 IP Motion Detector

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

INFRARED MODULATED BARRIERS

Safety Photo Beam UL MONITORED DEVICE

DI601AM Outdoor PIR/AM Detector Installation Sheet

COR-20 STANDALONE MAIN TITLE GOES MODE USER GUIDE HERE

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

OWNERS MANUAL OPERATION GUIDE

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Laser Distance Sensor Type M Analog-Output

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Installation Instruction Manual ILS-S

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

INDICE. Installation recommendation

SC Installation, Operation & Application Guide

Transcription:

Active Infrared Multi Beam Sensors R Series

TECHNICAL MANUAL INDEX GENERAL SAFETY RECOMMENDATIONS 3 CONFORMITY 4 WARRANTY 4 INTRODUCTION 5 FEATURES 5 OPERATIONAL RANGE 6 SETUP TRANSMITTER (TX) 6 SETUP RECEIVER (RX) 7 INSTALLATION 7 ALIGNMENT 8 ORIENTATION 8 TAMPER PROTECTION 8 MULTI BEAM INSTALLATIONS 9 CONNECTION 9 BRACKET DESCRIPTION 10 2

GENERAL SAFETY RECOMMENDATIONS 2 Safety Warnings Read and follow the instructions - Read the installation instructions before connecting the system to its power source. Follow these guidelines to ensure general safety. In order to prevent injury, burns or electrical shock to yourself and others, follow the connection instruction plan carefully. Product Safety Do not use the product in a wet location. Never push a foreign object through an opening inside the product. Slots and openings are provided for ventilation and should never be covered. Do not place under direct sunlight or heat sources. 3

CONFORMITY The infrared barriers R series e conforms with the essential requirements set out by: 89/336/EEC Electromagnetic compatibility directive 73/23/EEC Low voltage directive modified by 93/68/EEC Low voltage directive WARRANTY These products are warranted against defective parts and workmanship for twelve months from date of purchase. If any defect appears during the warranty period return it to the place of purchase. We assume no liability for consequential or indirect damage and accept no responsibility for repairing damage to the product caused by misuse, careless handling, or where others have made repairs. Disclaimer The content of this document has been prepared to the best of our knowledge, provided as is and is subject to change without notice. Hills Industries does not guarantee technical accuracy beyond the date of publishing. For the latest information please enquire about attending one of our Hills Reliance training courses. 4

INTRODUCTION The R-Series are multi beam active infrared sensors, consisting of a transmitter unit that sends syncronised beams of infrared light to a receiver unit, which evaluates this stream of infrared continuously. An alarm signal is generated when either a single beam or two adjacent beams are interrupted simultaneously (depending on setup). R-Series are available in 3, 4, 6, 8 and 10 beam configurations with lengths varying from 560mm to 2000mm and offer exceptional performance and stability in both internal and external environments. They are ideal for protecting single windows, a series of windows, doors, ceilings, skylights, roller doors or anywhere where a curtain of protection would enhance the ability of early intruder detection. R-Series are simple to adjust using the multidirectional swivel bracket that allows 180 degrees of alignment. The onboard alignment buzzer and LED will simplify installations, just align the bottoms of the beams on the same plane, making sure the two e-shields are parallel with each other. Then aim the two e - shields at each other and lock in place once correct alignment has been achieved. FEATURES Durable aluminum casing, with UV treated high impact resistant PVC ends. Stock colour is white, whilst other colours are available on request. (a small surcharge and minimum order quantities will apply) Model Beams Length Width Depth Coverage External Coverage Internal R056 3 560 28 22 Selectable 5 15M Selectable 10 30M R076* 4 760 28 22 Selectable 5 15M Selectable 10 30M R112 6 1120 28 22 Selectable 5 15M Selectable 10 30M R152* 8 1520 28 22 Selectable 5 15M Selectable 10 30M R200 10 2000 28 22 Selectable 5 15M Selectable 10 30M *denotes non stock, special order beams Table 1 Length dimensions shown are with PVC end caps in place. Operating voltage: 10.5Vdc to 16Vdc Operating current: max 95mA Tripping time:100ms Relay output: NC contacts, 50V AC/DC 120mA Temperature range: -25 C to +55 C Degree of protection: IP65 5

OPERATIONAL RANGE The range depends on the alignment, reflections and environmental brightness. The TX unit offers 4 selectable range settings, 5 15M for external installations and 10 30M for internal installations. Range settings are achieved by placing links on S1 and S2 to correspond to your requirements from table 3. Caution: Excessive power can compromise the beams integrity by generating too much Infrared signal, which might cause reflections from surrounding objects, and insufficient infrared signal can produce unwanted alarms from bright light from surrounding areas. First identify the minimum level required to operate the e Shield, then step the power up to the next setting and thoroughly re-test the system. Transmitter Setup Buzzer Buzzer control Buzzer disabled Buzzer enabled JMP 2 Number of beams required to be interrupted to activate alarm Activates alarm if any beam is Interrupted Activates ONLY if 2 adjacent beams are interrupted Table 2 Transmitter Setup - Range JMP S1 JMP S2 Indoor Outdoor 10m 5m Range 16m 8m 24m 12m 30m 15m Jumpers marked S1, S2, JMP2 and Buzzer are located on the inner pcb Table 3 6

Receiver Setup JMP 1 LED Operation LED will be ON if power is present and beams are aligned LED flashes when beams are broken LED OFF if power is present and beams are aligned LED flashes when beams are broken JMP 2 Number of beams required to be interrupted to activate alarm Activates alarm if any beam is Interrupted Activates alarm ONLY if 2 adjacent beams are interrupted Jumpers marked JMP 1 and JMP2 are located on the inner pcb Table 4 INSTALLATION Remove rubber cover cap (No 1 in Figure 5) Remove cover screw (No 2 in Figure 5) Remove cover to expose terminal block (No 3 in Figure5) Knock out circular cable entry hole leading to terminal block ( X in Figure 5) Thread cable through back of base ( Y in Figure 5) and feed through cable knockouts ( X in Figure 5) Mount the Transmitter and Receiver at the same height from ground level, facing each other. Connect wires to terminal block After alignment, lock in place top and bottom of both transmitter and receiver with rotation locking screw (No 6 in Figure 5) Replace front cover and fix in place with screw Replace rubber front cover cap 7

ALIGNMENT Figure 1 ORIENTATION Direct sunlight can reduce the efficiency of the receiver and possible cause false alarms. In order to prevent such alarms orientate the receiver away from the sun. Figure 2 MULTIPLE BEAM INSTALLATIONS In multi beam installations it is necessary to alternate the Receiver and transmitter in order to avoid interferences. Figure 3 8

TAMPER PROTECTION Every unit has a tamper switch located under the covers protecting the cable terminals. If a tamper function is required, connect the terminals marked TAMP on the RX unit in series with your alarm circuit (figure xxx). If a 24Hr tamper circuit is required, enable the panels dual end of line feature and terminate accordingly. The transmitters tamper switch must be closed prior to beam alignment. CONNECTIONS Single set of beams Figure 4 9

Figure 5 7 6 10 9 1 2 11 3 4 5 X 8 Y 3a 1 Rubber cap 7 End cap 2 Cover screw 8 Base 3 Cover 9 Water proof grommet A 3a Cover (rear view) 10 Spacer plate 4 Water proof membrane 11 Water proof grommet B 5 Terminal block PCB X Cable entry knockouts 6 Rotation locking screw Y Cable feed holes 10