The Seven Deadly Sins of Fiber Optics By Sean Sheedy, Fiber Optic Specialist

Similar documents
The Importance of Properly Cleaning Fiber During Splicing

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Hands-On CAT 5/6 & Fiber Optic Installer

When you need perfectly clean splices & connectors. Sticklers Fiber Optic Cleaners

Basic Professional Fiber Optic Installation

Sticklers Fiber Optic Splice &

2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Sources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates


User Guide. T-25S-L (Coating Clamp) T-25U-L (Coating Clamp)

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

Be Mr. Clean! Using Fluids Other than Alcohol When Cleaning Fiber Optic Connectors. By Mike Jones, MicroCare Corp.

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Fiber Optics for Todays Industry Applications

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions

The Rise of Tier 2 Testing

Benefits of Enhanced Event Analysis in. Mark Miller

Contemporary Considerations When Precision Cleaning Fiber Optic Connections

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

The FTA-02 Fiber Arranger

MOST EFFECTIVE METHOD FOR WIPING A FIBRE

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Suits SC, ST & FC 2.5mm PC & APC polish 525+ uses. Suits HFOCs in Optitip systems and other FTTx applications

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

The True Value of Connector Inspection: New Challenges and Best Practices

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

Core Alignment All In One Fusion Splicer

Ribbon All In One Fusion Splicer

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

IMPORTANT SAFETY INSTRUCTIONS

Fiber Optic Cleaners When you need perfectly clean splices & connectors

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Here is my experience and a few things I learned about my metallic epoxy floor install purchased from

Fiber Optic Connector Cleaning and Inspection Kit Instructions

Fiber Optic Products Catalog

Dome Fiber Optic Closure SC-221

TFS-FS1 Optical Leakage Detector. Operation Manual

USERS MANUAL EasySplicer

Integrity Pest Solutions. Heat Treatment Prep List

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

Special Provision No. 683S28 December 2017

Fujikura-70S Single Fibre Fusion Splicer

V. (Versus ) Bare Floor Vacuum

Introduction. Disclaimer. Application. EasySplicer components

1/2011 V1. Puzer AINO USER MANUAL. Read this instruction before using the vacuum cleaner! Keep the instructions near the vacuum cleaner for later use!

Discover Perfectly Clean. PRODUCT CATALOG. MicroCare International

OPERATOR S MANUAL WET/DRY VACUUM PF51 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

HW-17 Record Cleaning Machine Setup and Instruction Manual

3M Crimplok + Connector 8700-UPC & APC SM SC 900 µm

THE DAVENPORT CEILING FAN INSTALLATION INSTRUCTIONS

DIY Cabinet Painting Guide

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

USERS MANUAL EasySplicer

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

Field Test Procedure for Optical Fibre Link Measurements

PRODUCT BROCHURE. Steel City 5 SQUARE boxes It s time for an upgrade

White Paper: Fiber Contamination, Cleaning and Inspection. Introduction.

THE MW-1 Cyclone RECORD CLEANING MACHINE

8 lb Lightweight Vacuum Model CK LW 13/1

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

SB Elite. Installation & Operation Manual. Residential Use Indoor/Outdoor Installation. View our installation video. Scan to view

PRO-810. Fusion Splicer. Operation Guide

FTTHARCFUSIONSPLICER AD620

10QT AND 6QT BACKPACK VACUUMS

THE NIKKO CEILING FAN INSTALLATION INSTRUCTIONS

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

Product instruction manual Easymount Wide Format Laminators

User Guide. Portable banknote counter AB300

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS

Q.: I liked our single stream recycling. It was easier and more convenient. This is a step backwards. Why?

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

MicrOTDR. Optical Fault Locator. User Manual

Hazards or unsafe practices that may result in severe personal injury or death.

LEAK DETECTION KIT. Your Leak Detection Kit should include the following items:

Operations and Safety Manual

ADVANTAGE-100H-SC EXTRACTOR

EC Electricity... Our Unseen Friend

SOLUS-500 EXTRACTOR 120V

Powerful Money Saving Ideas BROUGHT TO YOU BY TVA AND YOUR LOCAL POWER COMPANY

SB-MAX Pro Series. Residential Use Indoor/Outdoor Installation. Installation & Operation Manual

The 7 attributes of highly effective quick disconnect couplings for liquid cooling of computers and servers

Product Catalogue. External Management

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

White Paper Fiber optic connections: check and clean first, then connect!

Owner s Manual PS-200

English as a Second Language Podcast ESL Podcast 331 Washing Clothes

SOLUS-310R EXTRACTOR

TT3000 and TT5000 Series

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

Owner s Manual PS-50. Document Number: Revision: Draft

Operating Instructions

Screw Compressors ESM Fixed Speed & VS Variable Speed

SWEATMISER ANTI-SWEAT HEATER CONTROLLER. Table of Contents

More heat energy means more of what type of energy? Does the mass change? So, what must change? What is the same in both containers?

ATCO How a Cooling Unit Works

Transcription:

The Seven Deadly Sins of Fiber Optics By Sean Sheedy, Fiber Optic Specialist First published in Outside Plant Magazine, October 2015 Does anybody in this totally digital, selfie-taking, Facebook-posting world remember the Seven Deadly Sins? Originally based on the Book of Proverbs, the Seven Deadly Sins were codified in the Middle Ages as the bad behaviors that guaranteed sinners were going to spend eternity on the wrong side of the Pearly Gates. People actually worried about the Seven Deadly Sins. The logic was stern and inflexible: Hell exists; people who sin go there; there is no escape. It was a perfect quid pro quo, entirely under the control of the individual. Your fate was in your hands. But here s a modern headline for you: when it comes to fiber optics, there really are Seven Deadly Sins. The fate of your network really is in your hands. Not the hands of an unknown network designer, or production operator at the 595 John Downey Drive, New Britain CT 06051 USA Tel: 860.827.0626 Fax: 860.827.8105 In North America, dial: 800.638.0125 On the Web: www.microcare.com The terms Sticklers and MicroCare and the Sticklers logo are registered trademarks of MicroCare Corp.

Seven Deadly Sins of Fiber Optics Page 2 of 9 cable system maker or in the hands of the equipment manufacturers who built your network gear; your hands. These aren't theoretical debates. After decades of splicing, connectorizing, testing, trouble-shooting, consulting, training and designing fiber optic systems, I personally can assure you there are real, hands-on decisions made every day that degrade the performance of fiber networks. Let's take a look: Sin # 1 Not Cleaning Before Splicing Before splicing, after you have exposed the fibers it s very important to clean them before cleaving. Cleaning the fiber ahead of time removes any remaining debris from the stripping process plus any other contaminants that may exist on the fiber. Please notice the importance of cleaning before cleaving. There is nothing cleaner than the end-face of a newly-cleaved fiber. Fiber never should be cleaned after cleaving. If you do, the fiber end-face will be contaminated. This will cause extra work for the fusion splicer in the pre-burn phase, shorten the lifespan of the units electrodes, degrade the mechanical strength of the splice in the form non-linear splices with bubbles, and cause excess signal losses. For cleaning bare fiber, it's strongly recommend operators use a fastevaporating, nonflammable precision cleaning fluid. While isopropyl alcohol (IPA) is commonly used, it is both hygroscopic and flammable. IPA is easily contaminated because it bonds with water molecules in air. Splicing technicians

Seven Deadly Sins of Fiber Optics Page 3 of 9 should seek out cleaning fluids that have been engineered specifically for cleaning splices. The best products are in sealed, nonrefillable containers that prevent cross-contamination and spills. Look for nonflammable cleaning fluids that evaporate quickly, leave no residues and do not contain water. Sin #2 Use the Wrong Cutting Tools Cable prep has long been considered an entry-level step, but it is far from that. This step determines how everything else plays out from physical connectivity to performance issues. Get it right, your network will be golden. Get it wrong well, that s why these sins are called deadly! The vast majority of experienced fiber techs are comfortable with hook or straight blade utility knives for cable prep. It s the tool they were brought up on. They know the proper pressure to apply when ringing fiber. They don t cut too deeply to avoid damaging the fiber. Using these tools requires skill, training and practice. It s the 21 st century. Today there is a wide selection of safe and highly effective hand tools that do not use open blades. The latest tool designs use protected blades with improved ergonomics including adjustable tension grips and the ability to ring-and-strip the cable all in one swipe This next generation of tools are engineered to improve operational safety while protecting the fiber in cable. So dump the knives and exposed blade tools and use the modern cutting tools that work for you, minimizing training and enhancing safety. These include fiber stripping tools, ring tools, hand scribes, snips and any other tools your specialty requires. While we re on the subject of hand tools: you need to clean them as well as the fiber. An annoying issue for technicians is breaking fibers during splicing prep; it effects fiber length and splice tray management. One way to limit fiber

Seven Deadly Sins of Fiber Optics Page 4 of 9 breakage is to clean all the operator s hand tools, especially the fiber stripping tools. Wipe them down with a fast-drying solvent and a lint-free wipe to remove any oils, particulate and residues, particularly the fiber acrylate coating and tight buffer coating debris. Sin #3 Don t Calibrate Your Fusion Splicer Everybody knows they must keep the fusion splicer, the cleaving tool and the v- grooves clean, and to keep calcium build-up off the electrodes. But many experienced operators also have noticed there are occasional situations when, no matter how many times they try, they cannot get a good splice on a fiber. Some attribute this to imperfections in the glass; others reclean the electrodes. If it cannot be fixed, the customer ends up with a couple of abandoned fibers. But those field techs might be looking in the wrong place. It s important to calibrate the fusion splicer itself. Specifically, the arch power or applied drive current needs to be adjusted occasionally, to ensure the proper amount of current is being applied, so that the splices are mechanically strong and optically perfect. This is particularly true when the barometer changes dramatically or the splicing job is at a high altitude. The calibration is very simple to perform. On most units, simply load the fibers as if to perform a splice. But instead of splicing, go to maintenance menu

Seven Deadly Sins of Fiber Optics Page 5 of 9 and select arch calibration or arch burn back test. The unit will prompt the operator through any other steps and then conduct the calibration. Upon completion, it will indicate it is properly calibrated or ask the operator to re-test the system. If you haven t calibrated before, multiple re-tests may be required as the unit adjusts itself for the electrical current, atmospheric density (altitude) and humidity, all of which must be configured properly for a successful splice. Sin #4 Micro-bending the Fiber Undetectable microscopic fiber bends ( micro-bends ) are a major issue with fiber cable assemblies when securing slack loops in both premises and outside plant networks. Micro-bending the fiber causes signal degradation but the problem probably will not be detectable by visual inspection. You won t find the trouble until you grab an OTDR. What s the cause? Over-compression of the fibers. The most common cause of micro-bends is over tightening cable ties used to secure the cable racking and other securing the cable slack loops. Another source of micro-bending occurs when cables are caught in hinges of panel doors or even stepped on. Specifically for splice cases, a great option is to use the clear transport tubes that come with many splice cases. The loose buffer tube will form-fit into the clear transport tubes and create a tight seal. The clear transport tube will then be dressed into the splice case tray where it can be secured with a tie wrap. The tie wrap will slide freely on the outside of the hard plastic buffer tube. This will

Seven Deadly Sins of Fiber Optics Page 6 of 9 prevent anything from pinching as the fibers shift, avoiding countless other issues. Sin #5 Exceeding the Bend Radius All fiber cables have a minimum bend radius. Users should take care to never exceed that radius to avoid damaging the cable and the fibers inside of it. When the bend in the cable exceeds the rated minimum, the fibers within suffer a type of damage called macrobending. Macrobending occurs when cable slack loops are wound too tightly and placed in a pedestal, hand hole or vault that is too small for the cable diameter in underground OSP networks. Products like snow shoes are designed to help fiber installers avoid macrobending of their aerial slack loops. Macrobending is common occurrence when an installer mouse ears the slack loop and uses zip ties to secure to the aerial plant. Macro-bending of the fibers can also occur in the splice trays. A common scenario is when small splice trays are used in combination with 60mm splice sleeves, rather than the proper 40mm splice sleeves. The larger splice sleeves will be too close to the edge of the splice tray and will not allow for a sufficient bend radius. What effect does this have? The answer becomes obvious when you test with an OTDR. Macro-bends are often missed unless the network is tested at the 1550nm or 1625nm frequencies. Most single mode systems operate at 1310nm

Seven Deadly Sins of Fiber Optics Page 7 of 9 because this wavelength is less sensitive to bends and other issues. However, more and more applications today also are using 1550nm and 1625nm. Here is the concern: these wavelengths are more sensitive to fiber aberrations. So at the 1310nm wavelength operators may see nothing odd on the OTDR screen but at 1550nm they may see something that resembles the Grand Canyon. Avoid excessive bending and these problems fade away. Sin #6 Hang on to Those Dirty Wipes It s laudable the effort employees will make to control costs and protect the environment, but re-using lint-free wipes is a false economy. In fact, it creates a network nightmare because everything becomes cross-contaminated. I have personally seen a fiber tech in a telco central office cleaning dozens of connectors using a disgusting, alcohol-soaked rag. I am sure if the tech had an inspection scope he would have been shocked at the damage he was inflicting on his network. Lets suppose a company provides a large 9x9 inch (23x23cm) wipe for their operators. That wipe becomes contaminated when a connector is wiped across it, for sure. The wipe also picks up hand oils and dust. That s bad, but it gets worse. A quality high modulus wipe is resistant to ripping, shredding and linting; it will be unlikely to deposit debris on an end-face. But most companies buy inexpensive low modulus cellulose wipes, held together with glues. These wipes shred easily as the sharp edges of a connector rumble across the wipe. Re-using those wipes definitely will redeposit particulate onto the end-face. Wipes are not a significant consumable expense. Let s concentrate on getting the connectors really clean and avoid the expense of a repair visit. Three important tips come to mind. First, don t buy large wipes; buy the smallest

Seven Deadly Sins of Fiber Optics Page 8 of 9 possible wipes. Avoid jumbo-sized bags of wipes; select wipes in proper packaging that will keep them clean until they are used. Lastly, teach your team that any wipe, once used, must be trashed. How much is it really saving you, if you have to waste extra time troubleshooting problems? Sin #7 You Can t See If You Don t Look Every field tech and every truck should be equipped with a low-power end-face inspection scope and proper end-face cleaning supplies. Even after 25 years in the industry, it still is shocking to me to see operators trying to clean fiber end-faces by wiping them on their shirts. The same lint that is removed from the dryer cage when you wash your clothes will get on the ferrule end face when you use your clothing to clean a connector. Every major equipment manufacturer and cable system maker recommends inspecting and clean when necessary before installation. Operators do not need fancy gear to deliver a clean, quality network. A ferrule scope will cost a carrier less than two repair visits. There are convenient, awardwinning cleaning kits available that deliver great results for less than 10 per connector cleaned. It makes sense to spend a few pennies to save hundreds of dollars on avoidable service calls.

Seven Deadly Sins of Fiber Optics Page 9 of 9 Avoid the Costs of These Sins These Seven Deadly Sins have long been a problem within the fiber industry. Like sloth and gluttony, these fiber optic sins have added significant and avoidable costs, slowed otherwise fast networks and caused significant network down time. Simple process changes and a modicum of awareness can make a huge difference in the performance of modern networks. We have the necessary tools and materials to avoid these sins, but just like in the Middle Ages it s all in your hands. About the Author Sean Sheedy has worked 20+ years as a fiber optic installer, troubleshooter, system designer, emergency restoration technician inspector, project manager, sales manager, and consultant to the telecom industry, military and government agencies and OEMs. He holds 30 industry certifications and also is a F.O.A. & E.T.A. certified instructor. Mr. Sheedy developed the fiber optic installation and troubleshooting course at Edmonds Community College in Edmonds, WA and still serves as the course instructor. In 2005, Sean became a published author with the release of Network Cabling Illuminated. While he still occasionally works out in the field, today he spends most of his days as a consultant and trainer. Sean can be reached at: fospecialist@gmail.com. About Sticklers Fiber Optic Cleaners Sticklers fiber optic cleaners deliver perfectly clean ports, jumpers and splices every time. Sticklers cleaners out-perform all of the old-style cleaning choices you might have seen: alcohol pump-bottles, linty paper wipes and expensive cartridge cleaners. For an even better value, the Sticklers cleaners are available in handy toolkits, with thousands of cleanings in each kit. Sticklers products are nonhazardous, so they can be shipped hassle-free. This means you get a cleaner network at the lowest possible cost. Eliminate expensive repair calls, boost customer satisfaction and avoid costly warranty claims, all while saving money chose Sticklers cleaners. Contact: TechSupport@SticklersCleaners.com +1 800.638.0125