NU2 Smart Power Supply (SPS) Manual

Similar documents
RACK MONITORING SYSTEM - RAMOS Ultra

Integrated Security Solutions

User Manual. Dryer Controller M720

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

HRX Technical Manual. Version 1.2

Dryer Controller M720

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Added password for IP setup page : Password must be in IP format!

RACK MONITORING SYSTEM RAMOS Ultra

Smart Wireless Sensor

Intelligent addressable fire alarm control panel

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Fire and Gas Monitoring Panel ST7-HV

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Solution F2. Fire Alarm Control Panels one step ahead.

Halton SAFE / 7.14 user guide and installation instructions

Integrated Security Solutions

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Batt-Safe Battery String Monitoring System

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

SMS GSM Alarm Messenger

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

USER MANUAL FOR OPERATING SYSTEM

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Monitoring Solutions

16 Zone Voice Evacuation VA & PA Sound System

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

YOUR PARTNER IN FIRE & GAS DETECTION

Public Safety DAS Annunciator Panel

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

Rack Mount Series Installation Guide

M2500 Engine Controller Installation Manual

Dew point set DS 400

Central Temperature Monitoring/Control System (I IOT Cloud solution)

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Med Touch Master Alarm

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Innovative Circuit Technology Ltd.

Installation, Operating and Maintenance Manual

UNC100 Integra Manual

Hydronic & HVAC Control Systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Smart Wireless Sensor

Home center Interface Server. Technical sheet

Carbon Monoxide Transmitter

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

5000 INSTALLATION GUIDE

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

ACTIVE INFRARED BARRIER

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

Model 17A00 Expansion Enclosure

Panel Mounted Fault Annunciator Series

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

THX-DL Data Logger USER & INSTALLATION MANUAL V

Using ANM Mobile CHAPTER

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

T4000 Security Communicator

Intelligent Addressable Fire Alarm System

Natural Ventilation Controller with 24vDC drive NVC-1204

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

SP-1000X. Panic Device Power Controller Installation Guide. Rev

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Tri-Tech Medical Inc.

Bionics Instrument. Alarm Handling. Gas Alarm Systems

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

SC-F3G User Manual 1.0

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

AIS750 Series Alarm Annunciator

ECC-50/100C. Emergency Command Center

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

CODESEC FIRE ALARM SYSTEMS. security technologies

DS7400Xi Addressable Control/ Communicator

1. Functions of GPS locator ETLOC-30S 3

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Operating Instructions

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

AS950 REFRIGERATED SAMPLERS

products and services

RTD TEMPERATURE SENSING SYSTEM

Transcription:

GENERAL The Smart Power Supply (SPS) is an innovative Quad Output, field programmable power supply. Each of the four outputs can provide four Amps for a total of sixteen Amps in either 12VDC or 24VDC. Outputs are protected by Digital Circuit Breaker (DCB) that allow for automatic SPS recovery after the short/overload condition is removed. Setup and Programming is achieved locally via Bluetooth from ios or Android mobile devices or remotely over TCP IP Ethernet connection via Web Browser utilizing user friendly Graphical User Interface. SPS is an Uninterruptable Power Supply. Utilizing lead acid backup batteries maintain its outputs voltages and currents when main power interruptions occur. Microprocessor controlled; three stages battery charging schemas is used to extend battery life and provide the user with charging speed options such as slow/ normal/ fast. Priority outputs disconnect performs smart load shedding disconnect before battery is depleted below manufacturer recommended voltage threshold. Depleting battery power below the rated threshold has the potential of damaging the equipment and shortens the battery s life span. Power & backup battery connections are protected against reverse polarity and battery mismatch such as connecting a 12V battery while configuring the power supply via Bluetooth/ Web to deliver 24V. An on board graphical LCD display presents SPS voltages, currents, temperature, and humidity with an optional 2 nd LCD connector for maintenance purposes or enhanced status viewing. Two programmable relays that can trigger on multiple alert conditions and a flexible fire alarm disconnect that is selected by output channel are native as well. An on board OSDP compliant RS 485 interfaces can integrate with other OSDP compliant products including NU2 s Universal Interface Board (UIB) line of products and the Multi Door Controller (MDC) Figure 1. SPS Block Diagram [back to Top] 1 P age

HARDWARE DESCRIPTION Figure 2. SPS Top View & I/O description 1a Outputs 1 & 2, 4A ea, Digital Circuit Breaker 1b Outputs 3 & 4, 4A ea, Digital Circuit Breaker 2 DC power in 33VDC/350W 3 Battery connector, 12V; 24V 4 Dry contacts, form C for 2 relays, programmable functionality 5 OSDP compliant, RS 485 communication port 6 4 programmable, Supervised Inputs 7 Fire alarm IN/OUT connector 8 Optional, Data and Communication Web Communication Module 9 Fire alarm output s selector; SPS as Standalone/Web selector 10 Intentionally left blank 11 Multi page graphical display 12 Optional, 2 nd Display port 13 USB Charging port 14 Factory use 15 Microprocessor and Bluetooth antenna 16 External Temperature probes 17 Optional port for 2 external temperature probes 18 Hand gesture, display manager [back to Top] 2 P age

SPS Inputs and Outputs NU2 Smart Power Supply (SPS) Manual 1. Output channels (1a & 1b): Four output channels on board driven by two 8A regulators. Each regulator drives a pair of output. Each pair has the same output voltage. Output voltage can be configured between 8V and 25V in increments of 0.1 volt. Configuration can be done locally via Bluetooth devices (ios or Android) or remotely via Web applications. Output channels are protected against short/overload condition with an automatically resettable Digital Circuit Breaker (DCB). The fuse will automatically restore power after the short/overload condition is corrected. The maximum output current is 4A per individual channel. If maximum current is exceeded for a pair of joined outputs, then, load shading will commence as follows: Figure 3. Optional DCC Data Controller, Database repository and Network connection. When the sum of the load current of Channel 1/2 (regulator A) or 3/4 (regulator B) exceeds 6.0A and below 8.0A, stable power will continue to be provided for 2 minutes and the local buzzer will sound. If the overload condition is not corrected within the 2 minutes window, then, output 2 or 4 (even channels) will be disabled for a duration of one minute. This step is repeated until the regulator s combined load is reduced to 6.0A or under. (See image #3 below). When the sum of load current of Channel 1/2 or 3/4 exceeds 8.0A, Output 2 and 4 respectively will be disabled immediately for 1 min. This sequence is repeated until the regulator s load is reduced to under 8.0A. (See image #3 below). [back to Top] 3 P age

Figure 3. Load shading flowchart 2. DC Input Connector: 33V +/ 1V @ 350W for 24VDC output. If all four outputs are configured for just 12V, then, input voltage range can be extended to 17VDC ~ 34VDC. 3. Backup Battery connector: 24V or 12V Lead Acid battery, featuring three stages of intelligent charging adjusted according to the battery s manufacturer s specifications. The SPS provides information about the battery s state of charge and battery health. Battery protection is provided for conditions such as: a. Reversed polarity b. Battery mismatched to programmed output voltage [12V inserted for 24V selection or 24V inserted for 12V selection] Real time battery voltage and charging current is shown on the graphical display providing a major advantage of not having to manually measure values. [back to Top] 4 P age

The SPS performs periodic and autonomous battery health and quality level tests. No manual action is needed. These microprocessors based tests involve forcing the battery to take over the full field load and then, using specialized algorithm, the software analyzes battery s capacity. The microprocessor monitors a variety of special conditions and sets its test environment such that no interruption to field devices occurs during the short period test. Go/no go test results are displayed to the user on the graphical display. If the battery failed the quality test, then, via user s configurations options (Bluetooth/Web), various alerts can be generated via local buzzer, activation of the auxiliary relays, and/or sending email/smnp messages. 4. Auxiliary Relay Outputs: There are 2 form C relays. Each relay has 2 outputs NC and NO that are rated at 2A. Each relay can be activated for a variety of reason(s) such as: 1) ALERT_TRIGGER_NONE 2) ALERT_TRIGGER_AC_LOSS 3) ALERT_TRIGGER_BATTERY_FAIL 4) ALERT_TRIGGER_LOW_BATT_80 5) ALERT_TRIGGER_LOW_BATT_60 6) ALERT_TRIGGER_REMOTE_CONTROLLED 7) ALERT_TRIGGER_EXCEED_CURRENT_ANY 8) ALERT_TRIGGER_EXCEED_CURRENT_OP1 9) ALERT_TRIGGER_EXCEED_CURRENT_OP2 10) ALERT_TRIGGER_EXCEED_CURRENT_OP3 11) ALERT_TRIGGER_EXCEED_CURRENT_OP4 Relays are triggered after defined time interval of 0 999 seconds which is user configured. Relays can be triggered by one or multiple events of SPS. 5. RS485 serial Interface: OSDP compliant RS 485 interfaces. The four pin connector is duplicated (in/out) to allow multiple connections with up to 48 other OSDP compliant devices that are complying with NU2 API, and control them from single GUI/UI interface point. This communication port connects multiple devices such as the UIB and MDC to create a single solution whereby all device s programming and status is shared and displayed. 6. Control Inputs: There are 4 general purpose supervised control inputs. When activated, each input can be configured to perform a different action. The list below provides the different options: 1) NONE 2) SEND_EMAIL 3) ENABLE OUTPUT1 4) ENABLE OUTPUT 2 5) ENABLE OUTPUT 3 6) ENABLE OUTPUT 4 7) DISABLE OUTPUT 1 8) DISABLE OUTPUT 2 9) DISABLE OUTPUT 3 10) DISABLE OUTPUT 4 [back to Top] 5 P age

Note 1: Dependency between a control input and an output is restricted to one dependency. Duplicate programming will be rejected, e.g. If an input is programmed to enable OUTPUT1 no other control input will be allowed to control OUTPUT1. Note 2: Control Input that controls output 2 or 4, will be disabled during 1 minute load shading explained above. 7. Fire Alarm Input and Output: Fire Alarm circuitry is expecting a Normally Closed (NC) contact from the building s fire alarm system to terminals F/A IN. The Fire Alarm OUT is a duplication of the IN status via a dry contact relay. This allows cascading multiple devices. Check local codes for compliance requirements. The Fire Alarm LED is normally green and turns red when the Fire Alarm circuit is activated. A timer is activated when Fire Alarm is activated. The time elapsed from activation is displayed on the LCD display in minutes and hours. Additional non CPU dependent features and functionalities are available via switch selection as noted at #9 below. 8. DCC Connecter: (When using the optional Data and Communications Controller module DCC). The DDC Connector is an eight conductors mini connector that supports communications via OSDP/RS 485 and 5VDC power to the DCC controller. The DCC has a built in Ethernet RJ 45 connector, to allow connection of the SPS to the customer s network/internet. DCC s program allows connection from any browser while providing the users with graphical HTML status and configuration views. [back to Top] 6 P age

Figure 4. Typical HTML view of SPS and 2 [back to Top] 7 P age

9. Fire Alarm & DCC/Stand Alone Control DIP SWITCH (SW1). DC1 DC4 when are in ON position (shift to right) will disable the corresponding 12V/24V outputs shown as OUT1 OUT4 when the Fire Alarm is activated via loss of the NC contact. <APP>24 when shift right then SPS becomes slave to the DCC. In this mode, the DCC communicate with the SPS, UIB(s) and MDC(s) and allow their connection to the site s network. Figure 5. F/A and DCC enable/disable switch selection 10. Intentionally left blank 11. LCD Display(320x240): A 320x240 pixel graphical display is provided onboard the SPS. The LCD display displays various SPS configurations and status in real time. Depending on configuration, the display alternates between several informative status screens. Unless interrupted via the hand gesture control (item #18) the display s content changes on 5 second intervals. There are various configuration and status on both Screens: [back to Top] 8 P age

SCREEN #2 Figure 6: Presents the followings: Figure 7. Header Name: The SPS name is displayed at the top header line. This header name is used to help the user identify the device s location such as 2 nd FL East Closet and for discovering the device through mobile BLE server (iphone/android/web application). Header name can be configured thorough these devices. The length of the header name is limited to 20 characters. Figure 8. Footer name: Located at the bottom of the Display. The programmable footer information can contain anything the user wishes to display such as installing company s name, service phone number etc. Footer line also displays the controller s address on the RS 485 chain. [back to Top] 9 P age

Figure 9. Input Status: Below header line, shows status of all four supervised Inputs. There are four dots, one for each input s status. The dot color is blue when inputs are inactive green when input is active. Input s functionality is described above. Figure 10. Output Status: There are four distinct control lines to show each output s state. Each output line shows the Voltage and the field s load current per channel. The output text color is Gray and Voltage/current is displayed as 0.0 V and 0.0A when Channel is disabled (via BLE/Web device or any alert condition). This provides highly important information to the user at a glance. Figure 11. Current Graph: There are four current graphs, one associated with each output channel. As current increases/decreases, current bar increases/decreases and graph s color is changed based on Alert current conditions as set by ios/ Android/ Web. If current is 0 50% of alert current then graph color is Green. If current is 50 75% of alert current then graph color is Yellow. If current is 0 50% of alert current then graph color is Red. [back to Top] 10 P age

Figure 12. Battery indicator: Battery indicator is enabled when battery is connected to SPS. Indicator shows in graphical manner the battery s health in percentage. When battery voltage is below 80% then graph color is changed to Red otherwise the color is Green. Figure 13. Input Power supply: This block shows the DC input voltage in Volts and total delivered power in Watts. Figure 14. Board temperature: The enclosure s temperature is displayed on the screen. The SPS has an additional onboard temperature probe used for fan control. Two optional, external temperature probes are available. See item #17. [back to Top] 11 P age

Figure 15. Humidity: Enclosures/closet humidity is monitored and displayed in percentage. Figure 16. Display Intensity: Display s illumination s intensity can also be configured by Mobile/Web application. This is shown as a percentage adjacent to the symbol. LCD intensity cannot be configured below 10% and above 100% and it is configured in 10% steps. Figure 17. Fire Alarm Status: Monitors and displays building s fire alarm status as noted at Item #7 above. Alarm status color is Green when normal and Red when in alarm condition. When it is off then Status color is Gray. An elapse timer shows the FA fault duration is 999h:59m format. [back to Top] 12 P age

Figure 18. Fan Speed: Fan speed section displays Fan Speed in percentage. Fan is OFF if total load current is below 0.45A. Speed changes based on onboard temperature sensor as well as anticipated current draw. Every 1A increment/decrement of load current increases/decreases fan speed as well. SCREEN #2 Figure 19. Screen 2: Presents the followings when optional DCC is connected: Figure 20. IP Address: Automatic discovery displays the device s IP address and other pertinent network information. There is no need to use discovery software. Connection to the SPS and its related devices such as the UIB and MDC is achieved by using a standard internet browser. [back to Top] 13 P age

Figure 21. Relay Status: The relay status is located below the header line and indicates each relay s status. When a relay is triggered due to any programmable event, the associated square icon button s color changes to Green/blue. The relay s trigger event s reasons are displayed and alternate to show multiple events. Figure 22. Device version: Above footer name to show Device & Web app version. SPS version is always displayed but Web App version is updated when Web server is connected. 2 1b 1a 17 16 15 14 13 12 Figure 23. SPS Top View & I/O description. 11 3 4 5 18 6 7 8 9 [back to Top] 14 P age

12. Secondary LCD Connector: Optional LCD connector. When connected to a secondary LCD will present additional diagnostic information maintenance and debug purposes. 13. USB Power connector: Provides 5V@1A to power USB powered devices. 14. Programming connector: factory use 15. Bluetooth CPU: BLE processor, database, communications and display manager 16. H1: The H1 connector allows connection to two additional remote temperature sensors. The H1 sensors can be used to monitor and report room s temperature, outside temperature etc 17. Function switch SW2: Allows for multiple functions such activation of the second remote display (hold switch for 4 seconds), advancing the display s status screens (quick push) 18. Gesture Control: detects hand s left/right motion to advance the graphical display s status screens. 19. DCC Data Control Center: Optional control unit, Linux OS, allowing central and remote control on single or bulk of SPS. Graphical User Interface, TCP IP protocol, LAN and WiFi connections. [back to Top] 15 P age