INSTRUCTIONS MANUAL FOR MED75HD - UPRIGHT GLASS DOOR FRIDGE

Similar documents
OPERATING AND INSTRUCTIONS MANUAL: B130/10/220H VACCINE REFRIGERATOR REV.1 (WITH TEMPERATURE HOLDOVER FUNCTION)

ICS PACIFIC. Installation Instructions & User Manual. G135L Medical Refrigerator

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

PRODUCT DESCRIPTION CONTROLS

USING THE REFRIGERATOR COMPARTMENT

HOW TO OPERATE THE REFRIGERATOR COMPARTMENT

Mobile Air Conditioner Instruction Manual Model TC-N9KM

User Manual. Commercial Refrigerator And Freezer User s Manual

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 17 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 19

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Instruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.

Outdoor and Indoor Electric Refrigerator Model COAR

EVAKOOL ELITE - UPRIGHT FRIDGE FREEZERS OPERATING MANUAL

Wine Cooler CVD121V/CVD131V/CVD130/CVD120

BEFORE USING THE REFRIGERATOR PAG. 9 PROTECTING THE ENVIRONMENT PAG. 9 PRECAUTIONS AND GENERAL SUGGESTIONS PAG. 9

HOW TO USE THE FREEZER COMPARTMENT PAGE 16

15,000 BTU Portable Air Conditioner

READ AND SAVE THESE INSTRUCTIONS

Double Door - Dual Zone Wine Cooler

Glass Door Refrigerators

Ui REFRIGERATOR SPEC SHEET

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

User Manual. Refrigerator ZRG16605WA

LEC L6014W/S User Manual

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

40cm Pedestal Fan with Remote Control

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

USER GUIDE. TL6015W TL6018W 60cm Larder

Contents. For your safety About your product Installing your appliance Using your appliance Care & cleaning...

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Installation & Operating Instructions

AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

8L Evaporative Cooler

Cabinet Refrigerators/Freezers Instruction manual

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

Convection Panel Heater

TCW 2000 Ice liner refrigerator and freezer PIJ

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

V 120 SG - V 160 SG. Instructions for use

UBBU60LFA. Built-under Fridge Manual for Installation, Use and Maintenance IM UBBU60LFA_

40cm Wall Fan With Pull Cord Operation

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

Turbo Circulating Fan (DC)

G-10f/GCG-10f UPRIGHT COOLER

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

RPI Industries, Inc.

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

User Manual. Freezer ZFT11112WE

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

READ AND SAVE THESE INSTRUCTIONS

FWC860 Wine Cooler Installation, Use and Maintenance

QUALITY & PERFORMANCE - THE LASTING IMPRESSION

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

FWC153, FWC304, FWC604 & FWC624

User manual. Freezer ZFU23400WA

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

Since User Manual LBC6178 Beverage Centre LWC646 Wine Storage Built Under. lemairappliances.com.au

ODE20: 20 LITRE DEHUIMIDIFIER

fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

Installation and Operation Guide For

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Bauknecht AG, Industriestrasse 36, 5600 Lenzburg,

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

INSTALLATION & OPERATION INSTRUCTIONS

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

WHD-125FW1 //WHD-125FB1/WHD-125FSS1

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

User manual. Freezer ZFU25200WA

User manual: Stainless steel CGN range Storage Refrigerators and FGN Storage Freezers

InstructIon Manual KrEs EQuIPMEnt stands

B900/ BME900/ SKOPE Gen2: Two Door Chiller

GLASS DOOR BAR FRIDGE

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

for LABORATORY REFRIGERATOR MODEL TELR-145/ L/200L CAPACITY REVISION

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

INSTRUCTION & USER MANUAL

Instruction Manual. Chest Freezer MODEL: KI130CF2

FTM419A01W USER S MANUAL FROST FREE REFRIGERATOR

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

STORER REFRIGERATION & CATERING MANUFACTURERS LTD

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

Modular Island Grill - Refrigerator Module

2.9kW Portable Air Conditioner

FDM Series. User Manual. SKOPE Food Display Cabinet Integral models: FDM900i/1200i/1500i. Model FDM1200i

11. Please follow cleaning instructions carefully so as to avoid injury or damage. 12. Should the Fan or protection fuse fail to work properly, turn

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Instruction Manual. Model: EPA 16 Portable Airconditioner

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

Transcription:

TC900E Version 7 Version230817 INSTRUCTIONS MANUAL FOR MED75HD - UPRIGHT GLASS DOOR FRIDGE PLEASE NOTE: THE VACCINE REFRIGERATOR WILL IMMEDIATELY GO INTO A DEFROST AFTER BEING POWERED ON Thank you for choosing a Minus 40 Refrigerator. We have supplied you a premium quality product, which incorporates the latest innovations in refrigeration technology. Properly maintained, it will give you many years of reliable service. Please read the following instructions carefully as it contains important information concerning the safety, installation, operation and maintenance of your Refrigerator. SAFETY Always disconnect the appliance from the mains supply before attempting to do any maintenance or before removing the bottom grille. In case of appliance failure, disconnect it from the power supply and contact your service technician or supplier for advice. If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Any service performed on these refrigerators within the 1-year warranty period MUST be cleared and reported to the manufacturer. Failure to do this will void the standard warranty. INSTALLATION Do a visual check of the unit to check for transport damage. Immediately report any damage to the transporter & supplier of the refrigerator. Remove all wrapping and packing material. Remove stacking blocks underneath the cabinet chassis. o Be careful not to damage any of the delicate wiring or pipe-work in the compressor compartment. Position the cooler out of direct sunlight and as far away as possible from any other sources of heat. o The maximum ambient temperature in which the cabinet will function is 44 Deg C. o The cabinet may be built into a furnishing fixture, or have its back to the wall, provided that the grille is totally unobstructed. The cabinet breaths through the grill. If it is blocked up, the cooler will not operate properly and you risk damaging the compressor. Level the appliance by rotating the adjustable feet. o The cabinet must be perfectly level in order for the door(s) to function properly. The door may be refitted to have its hinges on the left hand side and its handle on the right hand side. o First make sure the cooler is not connected to the electricity supply. Remove ALL shelves, clips and products from the inside so not to damage the glass door. o Then lay the refrigerator on its back. Release the hinge-pin nuts. o Unscrew the bottom hinge plate and carefully remove the door. o Remove the top hinge pin and fit it at the other side. o Rotate the door 180 C. Refit the door hinge pins and screw the bottom hinge plate to the opposite side. o Lock the bottom hinge pin nut with about 90 C torsion on the torsion bar. o Return the cabinet to the upright position. o Do not connect the appliance to the mains supply until you have read the following information. Minus40 is ISO9001:2008 Certified MINUS 40 (PTY) Ltd, 44 Manhattan Street, Airport Industria Ext 2, Western Cape, Republic of South. Africa PO. Box 254, Eppindust 7475, Republic of South Africa Tel: +27 (0) 21 386 2290 Fax: +27 (0)21 386 2295 Email: info@minus40.co.za Web: www.minus40.co.za Minus 40 (Pty) Ltd Reg. No. 89/03489/07 - Vat Reg No: 4090105521 Minus 40 Directors: S E Davison. D N McMurray Michael Werner

ELECTRICAL CONNECTIONS A qualified person in accordance with all local standards and regulations should carry out any electrical alterations to the appliance. The power supply should be in accordance with the electrical specifications listed on the rating plate. The rating plate can be located inside the cooler on the top right hand side. Always ensure that the electrical connection is suitably earthed. o An inadequate electrical installation can result in voltage reduction at the compressor which can cause damage to the motor. If in doubt about any of the electrical matters mentioned above, a suitably qualified electrician should be consulted. When all of the electrical requirements have been satisfied, the cooler may be plugged into the mains socket. OPERATING INSTRUCTIONS When loading the Refrigerator, always ensure that you do not block the internal air vents and always allow space for the cold air to circulate around the contents and the inside of the cooler. The Refrigerator is designed to automatically evaporate the condensate water in the compressor compartment. Before replacing the light tubes, make sure the appliance is switched off and disconnected from the mains supply. o Remove the transparent light covers by pulling outward. o Carefully pull off the electrical connections from the tube ends. o Replace with new tube with same dimensions and wattage and reconnect electrical push-on terminals. o Refit the transparent cover by hooking it back into position. o It is recommended to leave the lights switched on at all times (especially in high relative humidity areas). o It not only prolongs the lifetime of the light tubes, but also reduces risk of condensation in some areas. o From an electrical efficiency and safety point of view, we do not use electric elements to heat up any areas on our products. o Some components are specifically situated to utilize their heat transmission. CLEANING Before carrying out any cleaning: o Please ensure that the cooler has been disconnected from the electricity supply. o The refrigerator should be cleaned periodically with a non-abrasive cleaner and soft cloth. o Do not use any detergents or abrasive powders. o A damp cloth may be used provided that all surfaces are polished dry afterwards. PLEASE READ AND FOLLOW THE INSTRUCTIONS FOR CLEANING YOUR CONDENSER ON LAST PAGE PLEASE FILL IN: VACCINE REFRIGERATOR CONDENSER CLEANING SCHEDULE. MAINTENANCE Before carrying out any maintenance or repair work, please ensure that the cooler has been disconnected from the mains supply. To maintain maximum operating efficiency and to prolong the life of your cooler, the condenser must be cleaned regularly (at least every 2 months). In dusty environments, cleaning should be done more frequently. IN THE EVENT OF NOT USING THE COOLER FOR EXTENDED PERIODS o Disconnect from the power supply. o Remove all the products from the storage compartment. o Thoroughly clean the cabinet inside and out. o Leave the door(s) slightly open so that air can circulate freely. Page 2

TROUBLE SHOOTING COOLER NOT COOLING Note: some models have only one evaporator fan motor. Symptom Fridge does not run and the controller and the fans does not work and the lights are off. Fridge does not run, but the controller is on. Fridge is not cold enough Fridge is too cold Fridge is noisy Check Make sure the unit is plugged in Check for a tripped circuit breaker Check the temperature setting on the controller Clean the condenser coils Unplug the unit, wait two hours and plug it in. If you hear it running, a problem is causing the compressor to overheat Check if the evaporator fan is running Listen if the compressor ever runs. If not the compressor might be faulty. Check the temperature setting Assure that there is enough room for air flow in the fridge. Check if the evaporator coil is iced-up, and if it is, put the unit in a manual defrost as noted under MANUAL DEFROST. Check for air flow restrictions in front and at the back of the grille. Clean the condenser coils Check the door seal Check the temperature setting Hissing and popping is normal. Check that the fridge is level Check the drain pan Check the condenser fan (1) Check the evaporator fan (2) Fridge runs continuously Clean the condenser coils (1) Check the door seals IN THE EVENT OF A BREAKDOWN Disconnect the cooler from the power supply. Contact your supplier for advice. TEMPERATURE CONTROL Minus40 vaccine refrigerators regulates air temperature to control the product (vaccine) temperature. The running temperature of the refrigerators is factory pre-set at a range between 2 C to 8 C air temperature. It is factory pre-set with a built-in defrost sequence of 10 minutes every 3 Hours to remove ice build-up from the evaporator coil. During these defrost cycles air temperature can exceed 8 C for a short time, but product temperature will remain in the safe vaccine temperature range between 2 C to 8 C. FOR FRIDGE TEMPERATURE MONITORING ADVICE PLEASE SEE THE LINK BELOW: http://www.minus40.co.za/wp-content/uploads/2016/11/fridge-temperature-monitoring-advice.pdf SET POINT: 3 C Page 3

Minus 40 Vaccine refrigerator Condenser cleaning schedule 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Clean the condenser ( Radiator) with a vacuum cleaner or soft brush. Check the condenser monthly If there is dirt of fluff on the condenser clean as above Mark the chart above with a cross on the DAYS that the condenser is cleaned Page 4

Page 5